Comparison of two HPLC columns: An attempt to improve analysis of carbohydratedeficient. Ida Engström
|
|
- Rasmus Jonasson
- för 6 år sedan
- Visningar:
Transkript
1 Institutionen för kvinnors och barns hälsa Biomedicinska analytikerprogrammet Examensarbete 15 hp 2018 Comparison of two HPLC columns: An attempt to improve analysis of carbohydratedeficient transferrin Ida Engström Praktisk handledare: Markus Lindqvist Odutuyo Laboratoriemedicin Västernorrland, Sundsvalls sjukhus, Lasarettsvägen 21, Sundsvall Examinator: Anneli Stavreus-Evers Adress: Institutionen för Kvinnors och Barns Hälsa, Akademiska sjukhuset, Uppsala telefon: E-post:
2 ABSTRACT Carbohydrate-deficient transferrin (CDT) is a biomarker for excessive and long-running intake of alcohol. It is a form of transferrin called disialotransferrin that under normal circumstances is <2 % of total transferrin in human blood. An increase is seen when alcohol consumption exceeds 450 g per week. CDT is analyzed in serum using high performance liquid chromatography (HPLC) and UV/VIS detection. The purpose of this study was to investigate if an in routine method could be improved by switching columns. With ion exchange chromatography transferrin glycoforms are separated and quantified. The carbohydrate-deficient transferrin glycoforms have an isoelectric point between 5,7-5,9 that depends on the number of sialic acids on the molecule. With the use of a salt gradient and ph above the isoelectric point the glycoforms can be separated depending on their affinity to the stationary phase. Batches with patient and control serum was first analyzed on the routine column Source 15Q PE and then on the alternative column Reprospher 200 SAX 5µm. Student s t-test showed that the two methods results correlated but were significantly different. A Bland-Altman plot illustrated differences between the two columns. High and low control serum values from Reprospher were lower than the accepted interval. In this study Reprospher s stationary phase seemed to be affected to such an extent that stabile retention time, better resolution, and stabile values could not be achieved and because the information about the column was lacking an attempt to regenerate the column was not conducted. KEYWORDS Reprospher, liquid chromatography, ion exchange chromatography, CDT, gradient elution. 1
3 INTRODUKTION Carbohydrate deficient transferrin (CDT) är en biomarkör för hög och långvarig alkoholkonsumtion och används i utredningar av alkoholvanor. Analyten mäts i serum med high performance liquid chromatography (HPLC) och UV/VIS-detektor. CDT är en kolhydratfattig form av den järntransporterande molekylen transferrin. Transferrin är ett glykoprotein som syntetiseras främst i levern av hepatocyter (leverceller) men även i andra organ av andra celler, såsom av endotelceller i kapillärer i hjärnan och ependymalceller i plexus choroideus (hjärnventriklar) samt i bröstkörtlar vid laktation [1]. Koncentrationen av transferrin i serum ligger normalt mellan 2,0-2,5 g/l och ökar vid järnbrist, järnbristanemi och graviditet, och sjunker vid tillstånd som hemokromatos, akut inflammation och leversjukdom [1]. De kolhydratfattiga transferrinformerna är disialotransferrin, monosialotransferrin och asialotransferrin. Övriga former är trisialotransferrin, tetrasialotransferrin, pentasialotransferrin och hexasialotransferrin, varav tetrasialotransferrin är den som utgör största andelen transferrin i blodet (~80 %) [2]. Det är den procentuella andelen disialotransferrin av totalt transferrin som utgör provets CDT-värde, då det är denna form som främst ökar vid hög och långvarig alkoholkonsumtion. Mono- och asialotransferrin kan också öka [2]. Ett CDT-värde på >2 % tyder på en konsumtion av alkohol som per vecka överskrider 450 g alkohol, vilket motsvarar ett dagligt intag av en vinflaska eller 3-4 burkar starköl 1. 1 Pousette-Backlund, Christina Varför är CDT-värdet förhöjt? Transportstyrelsen. CDT-vardet-forhojt-/ (Hämtad ) 2
4 Onormala CDT-värden kan bero på ett antal orsaker: levercirros, ovanliga genetiska varianter av transferrin, alkoholmissbruk, biliär cirros, eller anorexia [3]. De små skillnader som kan ses på grund av ålder, kön, etnicitet och body mass index (BMI) är försumbara [4]. Medfödda glykolyseringsstörningar orsakar höga CDT-värden, dock är prevalensen för sådana medfödda sjukdomar låg och patienten har ofta kännedom om sjukdomen sedan barndomen [3, 4]. För patienter med levercirros eller annan leverabnormalitet försvåras eller omöjliggörs beräkningen av CDT-värdet på grund av interferenser orsakade av leverförändringarna [3, 5]. Ovanliga genetiska varianter av transferrin är ytterligare en faktor som kan komplicera beräkningen av resultatet [2]. Extra transferrinformer kan, beroende på genotyp, eventuellt försämra separationen. Den vanligaste genotypen i Europa är C1 med en prevalens på 75 % [3]. Hemolys eller höga nivåer av bilirubin kan orsaka viss störning men detta kan kringgås [2]. De olika transferrinformerna kallas för glykoformer. Dessa glykoformer innehåller kolhydratkedjor med 1-3 negativt laddade sialinsyror bundna till vardera av kedjornas avslut. Antalet negativt laddade sialinsyror och antalet bundna järn (0-2) påverkar transferrinmolekylens laddning [1]. Transferrin, som är ett protein, består av negativt och positivt laddade grupper där antalet av respektive grupp avgör proteinets nettoladdning. Eftersom antalet sialinsyror påverkar laddningen kan detta användas för att skilja formerna åt. CDT kan analyseras med en mängd olika metoder och utöver HPLC används bland annat kapillärelektrofores [6, 7]. Oavsett metod rapporteras inte resultatet i absoluta mängder eftersom mängden transferrin varierar mellan individer och påverkas av tidigare nämnda tillstånd och det medför därför svårigheter att ange ett referensintervall baserat på absoluta mängder [2]. Det mest lämpliga sättet är att ange CDT i area-% av totalt transferrin, men 3
5 metoderna kan skilja sig åt inte bara i resultat utan även i referensintervall och för att standardisera analysen har International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) föreslagit en referensmetod som tillämpar separation med på HPLC [2]. HPLC är en väletablerad vätskekromatografisk metod för att separera ämnen i ett prov och kan användas både vid kvantitativ och kvalitativ analys, men även preparativt. Vid vätskekromatografisk separation används en mobil fas, vars sammansättning kan varierar över tid, som transporterar provet genom en kolonn fylld med en stationär fas i vilken analyterna retarderas olika länge beroende på dess affinitet till den stationära fasen. Den mobila fasens uppgift är att konkurrera med den stationära fasen och eluera analyterna. Ordningen, i vilken analyterna i provet eluerar, avgörs av dess affinitet till den stationära fasen samt vad mobilfasen består av. Den genomsnittliga tid det tar för en typ av molekyl att passera kolonnen och detekteras kallas retentionstid 2. Beroende på antalet sialinsyror interagerar transferrinmolekylen olika starkt med den stationära fasen. Genom att använda jonbyteskromatografi kan de enskilda glykoformerna separeras och kvantifieras [2, 8]. Jonbyteskromatografi baseras på attraktionen mellan lösta joner i provet och den laddade stationärfasen 2. De kolhydratfattiga transferrinmolekylerna har en isoelektrisk punkt mellan 5,7-5,9, vilket betyder att vid det specifika ph-värdet är molekylens nettoladdning noll. Tetrasialotransferrin har isoelektrisk punk 5,4, vilket leder till att vid ph 5,4 är tetrasialotransferrinmolekylens nettoladdning noll. Genom att använda en mobilfas som har ph-värde över den isoelektriska punkten blir molekylen negativt laddad 3. När detta kombineras med en kolonn vars stationära fas är positivt laddad (en så kallad anjonbytare) attraheras de negativa transferrinmolekylerna elektrostatiskt till stationärfasen 2. 2 Harris, Daniel C Quantitative Chemical Analysis. 9. uppl. New York: W. H. Freeman and Company. 4
6 För att eluera analyterna kan mobilfasens ph eller jonstyrka förändras. I den här studien introduceras stegvis mobilfas med ökad jonstyrka (mobilfas som innehåller ökad mängd NaCl), där Cl-joner konkurrerar med analyterna om bindningsplatserna på stationärfasen, vilket leder till att analyterna släpper stationärfasen och elueras ut 3. Den med lägst negativ laddning/högst isoelektrisk punk elueras först. Den vanligaste stationära fasen består av sfäriska kiselpartiklar i olika storlekar med porer stora nog för analyten att penetrera. Partiklarna är bärare av kovalent bundna föreningar som analyten interagerar med. Analyter som består av stora molekyler, till exempel proteiner, analyseras bäst i kolonner vars stationära fas består av partiklar med stora porer så att molekylerna kan ta sig in i porerna och inte endast interagera på utsidan av partiklarna. Mindre partiklar ger snabbare jämvikt mellan mobilfas och stationärfas, vilket resulterar i snabbare eluering och effektivare kromatografering. Det eluerade provet åskådliggörs i en graf som visar detektorrespons som en funktion av retentionstiden. Detektion sker vanligtvis med UV/VIS spektrofotometer. Övriga detektionsformer förknippade med HPLC är till exempel fluorescens och masspektrometri 3. På Laboratoriemedicin Västernorrland analyseras S-CDT med HPLC-teknik. I skrivande stund används en kolonn med 15 µm partikelstorlek som ger en analystid på 35 min med godtagbar separation mellan topparna. Syftet med studien var att med en alternativ kolonn undersöka om den befintliga metoden kunde förbättras. Målet var att göra en tidsbesparing utan kvalitetsförsämring. Skillnader i retentionstid och upplösning för disialotransferrintoppen samt korrelationen mellan provresultaten studerades och jämfördes mellan rutinkolonnen och den alternativa kolonnen. 3 Harris, Daniel C Quantitative Chemical Analysis. 9. uppl. New York: W. H. Freeman and Company. 5
7 MATERIAL OCH METOD Kemikalier Kemikalierna som användes till mobilfaserna var 2,2-bis(hydroxymetyl)-2,2,2 nitrilotrietanol (Thermo Fisher Scientific, USA), HCl och NaCl (VWR International AB, Sverige). Till FeNTA-lösningen användes nitrilotriacetat trinatriumsalt monohydrat (Sigma- Aldrich, Sverige) och järn(iii)klorid hexahydrat (Thermo Fisher Scientific, USA). Den fettutfällande lösningen bestod av natriumdextransulfat (Pharmacia Biotech) och kalciumklorid dihydrat (VWR International AB, Sverige). Provförberedelser Från centrifugerade serumrör hälldes serum av och förbereddes enligt metodbeskrivningen på Laboratoriemedicin Västernorrland Sundsvalls sjukhus 4. Reagensen som användes bestod av lika delar fettutfällande lösning och järnmättande lösning. Den fettutfällande lösningen tillverkades enligt laboratoriets recept som baseras på det i en artikel av Helander et al. [8]. Lösningens slutliga koncentration var 10 g/l natriumdextransulfat och 0,5 mol/l kalciumklorid. För att järnmätta provet framställdes en FeNTA-lösning med slutkoncentrationen 10 mmol/l NTA och 10 mmol/l järn(iii)klorid enligt laboratoriets rutiner. Av serumet pipetterades 200 µl till ett mikrocentrifugrör varpå 80 μl reagens tillsattes. Rören inkuberades sedan i 4 o C i min innan de centrifugerades vid 3500 x g i 4 min. Därefter späddes supernatanten med ultrarent vatten med spädningsfaktor 2,5 i vialer. 4 Metodbeskrivning CDT S- HPLC Shimadzu, Laboratoriemedicin Västernorrland. 6
8 Vialerna placerades sedan i instrumentets automatinjektor. Alternativt utfördes pipetteringen med hjälp av en pipetteringsrobot och då användes mikrotiterplatta (1 ml) istället för vialer. I denna studie analyserades totalt 140 patientprov och 22 kontroller fördelade i sex batcher. Batch 1 innehöll 23 patientprov, batch 2 innehöll 38 patientprov, batch 3 bestod av 19 patientprov, batch 4 av 21 patientprov, batch 5 av 15 patientprov, och batch 6 bestod av 24 patientprov. Varje batch analyserades först med rutinkolonnen och därefter med den alternativa kolonnen. Ingen etisk prövning krävdes eftersom resultaten hanterades i instrumentets mjukvara där LID-numret inte kunde kopplas till patienten och inga provresultat med tillhörande LIDnummer presenterades i rapporten, därmed ansågs proverna avidentifierade. Låg och hög kontroll Kontrollmaterialet med lågt CDT-värde (1,031-1,323 %) var egentillverkat och bestod av serum från blodgivare. Serumet var blandat till en serumpool som frysts ner i provrör med 400 µl i vardera rör. Det höga kontrollmaterialet poolades på samma sätt men bestod av patientserum med CDT-värde >2 % (3,469-4,344 %). Innan analys genomgick kontrollerna samma provförberedelser som patientproverna. Låg och hög kontroll analyserades först och sist i alla provbatcher. Mobilfas De fyra buffertarna som användes i denna studie framställdes enligt receptet av Helander et al. [8]. Buffertarnas slutkoncentrationer var för startbuffert A 10 mmol/l Bis-Tris med ph 7.0, för eluent B och C 10 mmol/l Bis-Tris med ph 6.2 med tillsatt 0,1 mol/l NaCl i eluent 7
9 C, och för saltlösning D 2 mol/l NaCl istället för 0,5 mol/l som i receptet av Helander et al. [8]. Buffertarna tillsattes i kolonnen med flödeshastigheten 1 ml/min och enligt gradientprogrammet i tabell 1. Mobilfaserna bereddes på nytt allteftersom de tog slut i och med laboratoriets rutinanvändning. Tabell 1. Gradientprogram för separation av transferringlykoformer med high performance liquid chromatography (HPLC) med kolonnen Reprospher 200 SAX 5 µm. Här avläsas mobilfasens sammansättning vid bestämda tidpunkter. Tid (min) Startbuff. A (%) Gradient B (%) Gradient C (%) Saltlösn. D (%) , , ,8 88,2 0 13, , , , Instrument Instrumentet som användes var HPLC Shimadzu Prominence (Shimadzu Corporations, Japan) med följande delar: Solvent Delivery Unit LC-20AD, Degasser DGU-20AS, Autosampler SIL-20AC, Column Oven CTO-20AC, och UV/VIS Detector SPD-20AV. Programvaran var LC Solutions (Shimadzu Corporations, Japan). Laboratoriets rutinkolonn var Source 15Q PE (GE Healthcare Life Sciences, USA) med 15 µm partikelstorlek som användes tillsammans med ett förfilter med diametern 4,6 mm och porstorlek 0,5 µm från VICI Jour (Schweiz). Samma typ av förfilter användes vid analys med den alternativa kolonnen Reprospher 200 SAX 5 μm (Dr. Maisch GmbH, Tyskland). Reprospher 200 SAX hade ett ytterhölje av stål och var packad med kiselpartiklar. SAX står för strong anion exchange. 8
10 Regenerering av stationär fas För rutinkolonnen används ett rengöringsprogram cirka en gång i månaden för att regenerera kolonnen. En programcykel innefattar tillsättningen av 2 M NaCl, följt av vatten, följt av 1 M NaOH, följt av vatten, följt av 1 M HCl, följt av vatten, och slutligen 2 M NaCl. Lösningarna tillsattes i fem kolonnvolymer. Cykeln körs två gånger med omvänd flödesriktning och baseras på kolonnens medföljande instruktioner (Instructions AE), men med ändringen att istället för 1 M NaCl användes 2 M NaCl. För Reprospher 200 SAX 5 µm fanns inga rekommendationer för regenerering. Med kolonnen levererades varken ett kit insert eller specifikationer kring rengöring och därför utfördes inte regenerering under testets gång. Integrering av toppar Baslinjen som integrerade topparna började vid disialotransferrin, eller eventuell monosialotransferrintopp, och slutade efter hexasialotransferrin. Justeringar av baslinjen och toppintegreringen gjordes i instrumentets tillhörande programvara LC Solutions. Istället för att integrera alla toppar var för sig, som i rutinmetoden, integrerades tri-, tetra-, penta- och hexasialotransferrin utan toppseparation, som kan ses i figur 1. (se figur 1). Disialotransferrin integrerades på samma baslinje. Statistik För att undersöka ifall prover analyserade på båda kolonnerna skiljde sig åt signifikant gjordes ett tvåsidigt parat t-test. Korrelationen mellan resultaten från separationen med de två olika kolonnerna undersöktes i Excel 2013 (Microsoft, USA). En korrelationskurva konstruerades 9
11 och korrelationens signifikans fastställdes med ett t-test. Med hjälp av SigmaPlot (Systat Software Inc, USA) gjordes ett Bland-Altman-diagram. Ett medelvärde på retentionstiderna för disialotransferrintopparna i varje batch användes för att demonstrera retentionstidsförändringar mellan batcherna. Upplösning, även kallat resolution (Rs), är ett mått på hur väl två toppar är separerade från varandra och beräknades med följande formel: där Δtr är skillnaden i retentionstid mellan de två topparna och w11/2 och w21/2 är bredden av respektive toppar vid halva höjden 5. En upplösning som är högre än 1,5 innebär baslinjeseparation mellan topparna och ett värde på 1 betyder att 90 % av topparna är åtskilda 5. Ett tvåsidigt parat t-test beräknades på upplösningen för att se om kolonnerna skiljde sig åt bekräftande separationens kvalité. RESULTAT Med rutinkolonnen Source 15Q PE och den alternativa kolonnen Reprospher 200 SAX 15 µm analyserades på HPLC-instrumentet Shimadzu Prominence sex batcher som innehöll patientprov och 1-5 kontrollprov. I batch 6 analyserades låg kontroll totalt tre gånger (en i start, en i slutet och en i mitten). I övriga batcher analyserades låg och hög kontroll två gånger var, utom i batch 1 där endast hög kontroll analyserades i början. 5 Harris, Daniel C Quantitative Chemical Analysis. 9. uppl. New York: W. H. Freeman and Company. 10
12 Upplösningen beräknades för di- och trisialotransferrintoppar i höga kontroller analyserade med båda kolonner. Den genomsnittliga upplösningen var för rutinkolonnen 0,93 och för Reprospher 0,95. Ett tvåsidigt parat t-test visade att det observerade t-värdet var mindre än det kritiska t-värdet, vilket betyder att ingen signifikant skillnad kunde ses mellan kolonnernas upplösningar. Det kromatografiska utseendet för CDT-toppen och närliggande trisialotransferrintoppen i figur 1 (A, B, C) bekräftar också detta. En förändring över tid är visuellt synlig vid jämförelse mellan Reprospher batch 1 (B) och 5 (C). Figur 1. Kromatogram från rutinkolonnen (A) och kromatogram från hög kontroll i batch 1 (B) och 5 (C) analyserade med den alternativa kolonnen som visar skillnader i det kromatografiska utseendet mellan batcher. En korrelationkurva för båda kolonners CDT-värden plottades (figur 2). Beräknat t-test för signifikansen på korrelationen mellan Reprospher och laboratoriets rutinkolonn var större än det kritiska t-värdet och därmed förkastades nollhypotesen. Provresultaten från vardera kolonn var alltså signifikant korrelerade med varandra. 11
13 Reprospher 200 SAX 5 µm (CDT %) 3 2,5 2 1,5 1 0, ,5 1 1,5 2 2,5 3 3,5 Rutinkolonn (CDT %) Figur 2. Korrelationskurva för den alternativa kolonnen (Reprospher) och rutinkolonnen. Samma patientprov analyserades med båda kolonner. Korrelationkoefficienten var var 0,77. I ett parat t-test för mätserierna var det observerade t-värdet större än det kritiska t-värdet, vilket förkastade nollhypotesen. Det innebar en signifikant skillnad mellan provresultaten från analys med Reprospher och analys med rutinkolonnen. Medeldifferensen mellan de parade mätvärdena var 0,13. 12
14 Figur 3. Ett Bland-Altman-diagram med patientprov och kontroller analyserade på HPLC med rutinkolonnen och kolonnen Reprospher. Ett Bland-Altman-diagram (figur 3) gav ytterligare information angående skillnaderna och likheterna mellan metoderna. Ett tätt kluster syns vid medelvärde 1 eftersom de flesta provresultat var <2 %. 13
15 CDT-värde (%) 4,4 4,2 4 3,8 3,6 3,4 Reprospher Rutinkolonn 3, Hög kontroll Figur 4. Höga kontroller i kronologisk ordning analyserade före och efter batcher med patientprov (totalt 11 analyserade kontroller). De blå prickarna representerar resultat från Reprospher och de gröna prickarna representerar resultat från rutinkolonnen. Godkänt referensintervall för CDT-värde för höga kontroller var 3,469 4,344 % (mellan de blå horisontella linjerna). 14
16 CDT-värde (%) 1,5 1,4 1,3 1,2 1,1 1 0,9 Reprospher Rutinkolonn 0,8 0, Låg kontroll Figur 5. Totalt 11 låga kontroller i kronologisk ordning som analyserats med Reprospher (blå prickar) och rutinkolonnen (grön prickar) före och efter batcher med patientprov. Godkänt referensintervall för CDT-värde för låga kontroller var 1,031-1,323 % (mellan de blå horisontella linjerna). Figur 4 och 5 visade höga och låga kontroller analyserade med båda kolonner. Efter batch 3 låg alla kontrollvärden från Reprospher lägre än referensintervallet medan rutinkolonnens värden var inom intervallet. Hög kontroll hade som lägst ett värde på 3,16 % och låg kontroll hade 0,73 %, båda i batch 6. Retentionstiden för disialotransferrin antecknades för varje provinjektion, både för kontroller och patientprov och medelvärde beräknades för vardera batch. I batch 1 var den genomsnittliga retentionstiden 9,3 min, i batch 2 var den 9,6 min, i batch 3 9,7 min, i batch 4 beräknades genomsnittstiden till 10,2 min, i batch 5 till 10,1 min och i batch 6 var den 10,0 min. 15
17 Figur 6. Samma patientserum analyserat på HPLC med rutinkolonnen Source 15Q PE (A) och den alternativa kolonnen Reprospher 200 SAX 5 µm (B). Ett patientprov i batch 2 (se figur 6) hade en monosialotransferrintopp när analyserad med rutinkolonnen och innehöll 0,929 % monosialotransferrin och 2,497 % disialotransferrin (CDT) enligt programvarans integrering. Samma prov analyserades med Reprospher men då var monosialotransferrin inte detekterbar som en enskild topp och CDT-värdet var 2,761 %. DISKUSSION Syftet med denna studie var att undersöka om en HPLC-analys av CDT kunde förbättras genom att byta till en kolonn med mindre partikelstorlek och studera retentionstider för patientprov, upplösningar för höga kontrollprov, korrelation mellan provresultaten, och utseendet på vissa kromatogram. Ingen förändring gjordes gällande mobilfasernas sammansättning från rutinmetoden. Totalt analyserades, på båda kolonner, sex batcher med patientprov och 1-5 kontroller i varje. Analystiden kortades ner från 35 min med 16
18 kolonnen Source 15Q PE till 18 min med kolonnen Reprosphere 200 SAX 5µm. Då det tvåsidiga parade t-testet inte påvisade någon signifikant skillnad i upplösning mellan kolonnerna kan rutinkolonnen ersättas med Reprospher utan att analysen förlorar kvalitet. En korrelationskurva gjordes på provresultaten, i vilken det tycktes att en relativt tydlig korrelation fanns, varpå ett signifikanstest utfördes, som bekräftade att metoderna korrelerade. Det parade t-testet, som beräknades på mätseriernas parade provresultat, visade dock på en signifikant skillnad mellan kolonnerna. Eftersom metoderna korrelerade kan en faktor som kringgår skillnaden mellan kolonnerna användas för att likställa metodernas mätvärden så att Reprospher mäter likt rutinkolonnen, om rutinmetoden anses vara golden standard. Men i Bland-Altman-diagrammet åskådliggjordes skillnaderna ytterligare i den alternativa metodens resultat jämfört med rutinmetodens resultat (se figur 3). Här åskådliggörs hur viktigt det var att studera metodernas skillnader istället för deras likheter, eftersom båda metoder mäter samma sak. Bland-Altman-diagram används för att grafiskt visualisera olikheter och därmed visa att korrelation inte är ett bra mått för att bevisa att två metoder stämmer överens [9]. Skillnaden mellan metoderna var tydlig i och med spridningen vertikalt, både vid låga och höga värden (se figur 3), som både beror på brus och ostabila mätvärden. Vidare visade diagrammen över höga och låga kontroller (figur 4 och 5) att resultaten från Reprospher-metoden blev lägre än referensintervallet, ju fler batcher som analyserades. Det här var ett tydligt bevis på att kolonnen inte håller en godtagbar kvalitet, använd på det sättet som den användes i den här studien. Påståendet förstärks av drivande retentionstider, som kan orsakas av en mängd anledningar. Temperaturen på kolonnen, bland annat, kan orsaka förändringar i retentionstid; ökad temperatur i kolonnen ger kortare retentionstid medan sänkt 17
19 temperatur ger längre retentionstid 6, och därför används en kolonnugn för att stabilisera förhållandena. Trots att temperaturen inte studerades i den här studien var det troligt att det inte skedde kraftiga temperaturförändringar eftersom analysresultat från rutinmetoden inte uppvisade samma förändring. En kolonn avsedd för HPLC har typiskt en livslängd på injektioner 6 men i denna studie sågs förändringar betydligt tidigare (162 provinjektioner). Till en början såg kromatogrammet bra ut (se figur 1B) och disialotransferrin hade en retentionstid på 9,3 min men i de avslutande batcherna var genomsnittliga retentionstiden för batcherna över 10 min. Mer specifikt sågs initialt en ökning i retentionstid men den minskade från att som mest vara 10,4 min i batch 4 till 10,0 min i batch 6. Om topparna i kromatogrammet inte ser bra ut, till exempel är asymmetriska eller uppvisar tailing (svans i slutet av toppen), måste orsaken såklart undersökas och åtgärdas och kan bero på en felaktigt framställd mobilfas eller tilltäppning i förfiltret 7. Dessa kan uteslutas genom att blanda ny mobilfas och byta förfiltret. Efter batch 3 byttes förfiltret enligt laboratoriets rutiner. Att felaktigt framställda mobilfaser orsakade förändringen var också osannolikt då samma mobilfaser användes till analyserna med rutinkolonnen, som bedömdes vara felfria. Däremot kunde mobilfaserna och gradientprogrammet, på grund av att de inte anpassats till Reprospher, påverkat stationärfasen så pass att dess kemiska egenskaper förändrats och därför uppvisade en förlängd retentionstid och lägre värden på kontrollerna. 6 Dolan, John. W Retention Time Drift - A case study. LCGC Europe. (Hämtad ). 7 Crawford Scientific. Causes of Retention Time Drift in HPLC. Crawford Scientific. (Hämtad ). 18
20 Ett annat alternativ var att komponenter som inte tvättats bort efter provinjektionen eller som förfiltret inte stoppat packats i kolonnen och påverkat interaktionen mellan den stationära fasen och provet. Sådana föroreningar kan bättre undvikas med en förkolonn än ett förfilter 7. Den enda modifiering som gjordes till rutinmetoden inför analys med Reprospher, utöver att förkorta detektionstiden, var att förlänga ekvilibreringstiden, det vill säga tiden då saltlösning D byts ut mot startbuffert A. Här kan argumenteras att ekvilibreringstiden, även kallad jämviktstid, skulle varit längre för att försäkra att kolonnen återställts innan nästa provinjektion. En sådan faktor bör undersökas ytterligare. När liknande problem uppenbarar sig med rutinkolonnen, det vill säga förändrade retentionstider eller tailing toppar, regenereras den med det rekommenderade regenereringsprogrammet med nämnda modifieringar. Reprospher-kolonnen levererades utan rekommendationer för regenerering och kontakt med leverantören resulterade inte i mer information, så ett försök att regenerera Reprospher utfördes inte. Ett prov i batch 2 som med rutinkolonnen visade sig innehålla 0,93 % monosialotransferrin hade inte samma tydliga utseende i kromatogrammet med den alternativa kolonnen (se figur 6). Monosialotransferrin elueras för tätt inpå disialotransferrin och orsakade en dåligt avgränsad CDT-topp och eventuellt ett felaktigt resultat. Monosialotransferrin kan öka med över 30 % vid jämförelse mellan patienter med CDT <2 % och >2 %, medan asialotransferrin kan öka med över 200 %, men ökningarna är individuella [10]. I figur 1 (B) detekterades någonting efter 6,0-6,5 min. Den här toppen tycktes inte finnas i kromatogrammet från senare batch (se figur 1C). Om det var asialotransferrin eller någonting annat var svårt att säga. 19
21 En alternativ metod till vätskekromatografi är kapillärelektrofores, som till skillnad från immunokemiska analyser och i likhet med HPLC-analys visualiserar resultatet och möjliggör för upptäckten av till exempel interfererande genetiska transferrinvarianter [11, 12]. Kapillärelektrofores används främst med spektrofotometrisk detektion [12, 13] men masspektrometrisk detektion har också använts, dock med svårigheter [14]. I en artikel av Kenan et al. [15] påpekas att med kapillärelektrofores medföljer interferenser som kan göra det nödvändigt med bekräftande analys på HPLC. Utöver de vanliga problemen tycks okända interferenser påverka vissa provresultat i kapillärelektroforesisk analys men inte i de bekräftande analyserna på HPLC [15]. I en artikel av Sorio et al. [16] undersöks möjligheten att, istället för HPLC med absorptionsdetektion, använda HPLC med fluorescensdetektion genom att med en probe bestående av det metalliska grundämnet terbium märka transferringlykoformerna, separera dessa med anjonbyteskromatografi och detektera fluorescensen av vardera glykoform vid 550 nm. Intressant var att det karaktäristiska mönstret av humant transferrin bekräftade att terbium inte påverkar transferringlykoformernas laddning och vidare analys av serum från avlidna patienter visade att hemoglobin inte interfererade, vilket det vanligtvis gör vid analys av serum från avlidna patienter vid absorptionsdetektion [16]. Att CDT analyseras med flertal olika metoder eller modifieringar av metoder anses inte förvånande och det initiativ som tagits att standardisera analysen [2] är troligtvis uppskattat ur laboratoriepersonalens och forskarnas synvinkel med avseende på tillförlitlighet, jämförbarhet och effektivitet. På Laboratoriemedicin Västernorrland är sökandet efter en snabbare metod inte över i och med att denna studie nått sitt slut. Det viktigaste resultatet var den tydliga degeneringen av den alternativa kolonnen när den användes under samma förhållanden som 20
22 rutinkolonnen, som tyvärr inte kunde åtgärdas i brist på information om kolonnen. Fler försök rekommenderas utföras innan kolonnen benämns opassande för analysen men med tanke på att rutinmetoden redan liknar IFCC s rekommendationer är sannolikheten stor att metodutvecklingen som följer härefter skiljer sig från den standardisering som IFCC eftertraktar. TILLKÄNNAGIVANDE Tack till Laboratoriemedicin Västernorrland på Sundsvalls sjukhus och speciellt tack till avdelningen för Specialkemi. Personalen där har bidragit inte bara med tid och hjälp, utan också med stöd och glädje. De har samarbetat med mig och jag med dem för att göra det bästa och mesta av den här studien. Tack också till min handledare som guidat och diskuterat med mig, och tack till min skrivargrupp som gett ordentligt med bra feedback och idéer. REFERENSLISTA [1] de Jong G, van Dijk J.P, van Eijk H.G. The biology of transferrin. Clin Chim Act. 1990;190(1-2):1-46. [2] Schellenberg F, Wielders J, Anton R et al. IFCC approved HPLC reference measurement procedure for the alcohol consumption biomarker carbohydrate-deficient transferrin (CDT): Its validation and use. Clin Chim Act. 2017;465:
23 [3] Arndt T et al. Atypical serum transferrin isoform distribution in liver cirrhosis studied by HPLC, capillary electrophoresis and transferrin genotyping. Clin Chim Acta. 2008;394(1-2): [4] Bergström J. P, Helander A. Influence of alcohol use, ethnicity, age, gender, BMI and smoking on the serum transferrin glycoform pattern: Implications for use of carbohydratedeficient transferrin (CDT) as alcohol biomarker. Clin Chim Act. 2008;388(1-2): [5] Stewart SH et al. Liver disease and HPLC quantification of disialotransferrin for heavy alcohol use: a case series. Alcohol Clin Exp Res. 2010;34(11): [6] Bortolotti F et al. Fullt automated analysis of Carbohydrate-Deficient Transferrin (CDT) by using a multicapillary electrophoresis system. Clin Chim Acta. 2007;380(1-2):4-7. [7] Joneli J et al. Determination of carbohydrate-deficient transferrin in human serum by capillary zone electrophoresis: evaluation of assay performance and quality assurance over a 10-year period in the routine area. 2013;34(11): [8] Helander A, Husa A, Jeppson J.O. Improved HPLC method for carbohydrate-deficient transferrin in serum. Clin Chem. 2003;49(11): [9] Giavarina D. Understanding Bland Altman analysis. Biochem Med (Zagreb). 2015;25(2):
24 [10] Mårtensson O et al. Transferrin Isoform Distribution: Gender and Alcohol Consumption. Alcohol Clin Exp Res. 1997;21(9): [11] Helander A et al. Toward standardization of carbohydrate-deficient transferrin (CDT) measurements: II. Performance of a laboratory network running the HPLC candidate reference measurement procedure and evaluation of a candidate reference material. Clin Chem Lab Med. 2010;48(11): [12] Song B et al. Determination of carbohydrate-deficient transferrin in a Han Chinese population. BMC Biochem. 2014;15(5). [13] Crivellente F et al. Improved method for carbohydrate-deficient transferrin determination in human serum by capillary zone electrophoresis. J Chromatogr B Biomed Sci Appl. 2000;739(1): [14] Kohler et al. New insights in carbohydrate-deficient transferrin analysis with capillary electrophoresis-mass spectrometry. Forensic Sci Int. 2014;243: [15] Kenan N, Husand S, Helander A. Importance of HPLC confirmation of problematic carbohydrate-deficient transferrin (CDT) results from a multicapillary electrophoresis routine method. Clin Chim Acta. 2010;411(23-24): [16] Sorio D et al. Fluorescent adduct formation with terbium: a novel strategy for transferrin glycoform identification in human body fluids and carbohydrate-deficient transferrin HPLC method validation. Anal Bioanal Chem. 2017;409(5):
Metodverifiering av ny upparbetningsmetod för kolhydratfattigt transferrin
Fakulteten för hälso- och livsvetenskap Examensarbete Metodverifiering av ny upparbetningsmetod för kolhydratfattigt transferrin Författare: Desirée Ulin Ämne: Biomedicinsk laboratorievetenskap Nivå: Grundnivå
Ylva Hedeland Niclas Rollborn Anders Larsson. Analys av HbA1c metodjämförelse mellan några sjukhuslabb i Sverige
Ylva Hedeland Niclas Rollborn Anders Larsson Analys av HbA1c metodjämförelse mellan några sjukhuslabb i Sverige Analys av glycerat hemoglobin (HbA1c) Capillarys 3 Tera- instrumentering och metodprincip
Illustrerad noggrannhet
Illustrerad noggrannhet riktighet och precision med mål och mening Equalis Allmän klinisk kemi 15-16 november 2012 Mikaela Norman, Sjukhuskemist, Klinisk kemi, Falu Lasarett mikaela.norman@ltdalarna.se
Högupplösande vätskekromatografi (HPLC) Niklas Dahrén
Högupplösande vätskekromatografi (HPLC) Niklas Dahrén Högupplösande vätskekromatografi (HPLC) HPLC= high performance liquid chromatography eller på svenska högupplösande vätskekromatografi. HPLC är en
Kromatografimetod. Separation genom olika distribution av molekyler mellan en mobil fas och en stationär fas
Kromatografi Separation genom olika distribution av molekyler mellan en mobil fas och en stationär fas LC-Vätskekromatografi (oftast vattenbaserade system) Kolonner vanligast men andra system finns Separationsprincip
Isolering och rening av proteinet tiopurinmetyltransferas
Isolering och rening av proteinet tiopurinmetyltransferas Inledning och syfte Proteinet tiopurinmetyltransferas (TPMT) är ett humant enzym vars naturliga funktion ännu är okänd. Proteinet katalyserar överföring
4. VÄTSKEKROMATOGRAFI
LABORATION I ANALYTISK KEMI (KEGBAA, BLGAK0) 4. VÄTSKEKROMATOGRAFI Laborationen syftar till att introducera vätskekromatografi med vilken koffeinhalten i olika prover bestämms 1 Inledning HPLC-tekniken
Kromatografi. Kromatografi
Kromatografi Tekniker för att Rena Ex. inför vidare studier, terapeutisk användning etc. Fraktionera Ex. inför vidare analys, Depletion av HAPs från plasma inför 2D-gel (max-kapacitet
Upprättare: Thomas K Claesson Granskare: Annelie Strömbäck Fastställare: Lars Hansson
Upprättat datum: 2016-11-25 1(40) Division Diagnostik Revisionsnr: 8 Giltigt t.o.m.: 2017-12-14 Laboratoriemedicin Metodansvarig: Thomas K Claesson Medicinskt ansvarig: Lars O Hansson Upprättare: Thomas
Vitamin D Lc-Ms/Ms. Benny Larsson Laboratorie Medicin Skåne Klinisk Kemi Malmö
Vitamin D Lc-Ms/Ms Benny Larsson Laboratorie Medicin Skåne Klinisk Kemi Malmö 25-OH-Vitamin D3 + D2 3-epi-25-OH-Vitamin D3 + D2 1,25-di-hydroxy-Vitamin D3+D2 25-OH-Vitamin D3 + D2 3-epi-25-OH-Vitamin D3
Bestämning av fluoridhalt i tandkräm
Bestämning av fluoridhalt i tandkräm Laborationsrapport Ida Henriksson, Simon Pedersen, Carl-Johan Pålsson 2012-10-15 Analytisk Kemi, KAM010, HT 2012 Handledare Carina Olsson Institutionen för Kemi och
Gaskromatografi (GC) Niklas Dahrén
Gaskromatografi (GC) Niklas Dahrén Gaskromatografi (GC) GC= gas chromatography eller på svenska gaskromatografi. Gaskromatografi är en avancerad kemisk analysmetod som används för t.ex. gift-, drog- och
Kromatografi. Den kromatografiska processen. Fördelar med HPLC - (utförs under högt tryck ca 400 Bar) Vätskekromatografi. Olika former av LC
Kromatografi Den kromatografiska processen Separationsmetod, där komponenterna som ska separeras, fördelas mellan två faser, en stationär fas och en mobil fas. Injektion 0 min Vätskekromatografi vätska
Detektion av Borrelia burgdorferi IgG. med hjälp av ELISA
Umeå Universitet Biomedicinska analytikerprogrammet Detektion av Borrelia burgdorferi IgG med hjälp av ELISA Årskull: Laborationsrapport i immunologi termin 3 Laborationsdatum: Inlämnad: Godkänd: Handledare:
- Sänkt pris för B-PEth den bästa alkoholmarkören. - Ändrade referensintervall för barn och vuxna: P-Kreatinin P-Ferritin P-Järn P-Transferrin
Version 1.0 LABORATORIEMEDICIN Laboratorienytt Nr 2, april 2012 Innehåll: 2-4 Klinisk kemi - Sänkt pris för B-PEth den bästa alkoholmarkören - Ny och bättre metod för analys av 25-hydroxi Vitamin D i serum
Metodutvärdering I. Metodutvärdering -validering. Metodutvärdering II. Metodutvärdering III
Metodutvärdering I Metodutvärdering -validering Nya metoder utvecklas för att Förbättra noggrannhet och precision Tillåta automation Minska kostnader Arbetsmiljö Bestämning av ny analyt Metoden måste verifieras
IGFBP-3 på IDS isys (NPU28268)
2018-11-15 17 1(6) IGFBP-3 på IDS isys (NPU28268) Bakgrund, indikation och tolkning Insulinlik tillväxtfaktorbindare 3 (IGFBP-3) är ett glykoprotein som består av 264 aminosyror. Molekylvikten är ca 46
Preparation och spektroskopisk karakterisering av Myoglobin
Datum på laborationen: 2010-11-16 Handledare: Alexander Engström Preparation och spektroskopisk karakterisering av Myoglobin Namn/Laborant: Jacob Blomkvist Medlaborant: Emmi Lindgren Antonia Alfredsson
Tunga metaller / Heavy metals ICH Q3d & Farmakope. Rolf Arndt Cambrex Karlskoga
Tunga metaller / Heavy metals ICH Q3d & Farmakope Rolf Arndt Cambrex Karlskoga Tunga metaller / Heavy metals Rolf Arndt -Quality Assurance Cambrex Karlskoga - Svenska Farmakopekommitten / Working Party
Biomarkörer kan fånga tidigt riskbruk av alkohol
klinisk översikt läs mer Engelsk sammanfattning Lakartidningen.se Biomarkörer kan fånga tidigt riskbruk av alkohol Alkoholmarkörer ger svart på vitt om en persons alkoholintag över tid. Därmed kan riskbruk
TENTAMEN KEMISK MÄTTEKNIK (KD1190/1110), 2011-01-10
TENTAMEN KEMISK MÄTTEKNIK (KD1190/1110), 2011-01-10 OBS! Använd ett ark per uppgift. Skriv namn på varje ark. OBS! För varje uppgift anges maximalt antal poäng. För godkänt resultat fordras 40 poäng. En
Introduktion till laboration Biokemi 1
Introduktion till laboration Biokemi 1 Annica Blissing IFM Biochemistry Upplägg Laborationen sträcker sig över flera tillfällen Isolering, gelfiltrering, absorbansmätning och påvisande av sulfat Provberedning,
Analytisk kemi. Kap 1 sid 15-22, Kap 9 sid
Analytisk kemi Kap 1 sid 15-22, Kap 9 sid 267-271. Vetenskaplighet Vetenskapligt fastlagt ngt som är systematiskt undersökt och är öppet för granskning (transparent) Granska ngt källkritiskt utgå från
Diagnostik av subarachnoidalblödning ur laboratoriets synvinkel. Peter Ridefelt Klinisk kemi och farmakologi, Akademiska sjukhuset, Uppsala
Diagnostik av subarachnoidalblödning ur laboratoriets synvinkel Peter Ridefelt Klinisk kemi och farmakologi, Akademiska sjukhuset, Uppsala Diagnostik av subarachnoidalblödning Datortomografi Lumbalpunktion
B-HbA1c, DCA Vantage Metodbeskrivning Patientnära analysverksamhet
1(5) Metodbeskrivning Patientnära analysverksamhet HbA1c eller glykerat hemoglobin är en hemoglobinvariant som bildas då glukos i blodet långsamt binds till Hb och som återspeglar medelkoncentrationen
U-Proteinprofil ger bl.a. en uppfattning om nivå av albumin och protein HC i urinen samt huruvida tecken på Bence-Jones proteinuri föreligger.
1(5) S/U-Proteinprofil Bakgrund, indikation och tolkning S-Proteinprofil ger främst en uppfattning om akutfasreaktionen och immunglobulinmönstret hos patienten. Indikationerna är utredning av förhöjd SR,
Analys av medelvärden. Jenny Selander , plan 3, Norrbacka, ingång via den Samhällsmedicinska kliniken
Analys av medelvärden Jenny Selander jenny.selander@ki.se 524 800 29, plan 3, Norrbacka, ingång via den Samhällsmedicinska kliniken Jenny Selander, Kvant. metoder, FHV T1 december 20111 Innehåll Normalfördelningen
Analysera gifter, droger och andra ämnen med HPLC och GC. Niklas Dahrén
Analysera gifter, droger och andra ämnen med HPLC och GC Niklas Dahrén Vad står förkortningarna GC och HPLC för? GC= gas chromatography eller på svenska gaskromatografi. HPLC= high performance liquid chromatography
Kurskod: TAMS28 MATEMATISK STATISTIK Provkod: TEN1 05 June 2017, 14:00-18:00. English Version
Kurskod: TAMS28 MATEMATISK STATISTIK Provkod: TEN1 5 June 217, 14:-18: Examiner: Zhenxia Liu (Tel: 7 89528). Please answer in ENGLISH if you can. a. You are allowed to use a calculator, the formula and
Preparation av hemoglobin med hjälp av gelfiltrering
Preparation av hemoglobin med hjälp av gelfiltrering Teori Vid preparation av ett protein används en rad olika metoder för att specifikt rena fram det önskade proteinet. I vårt fall ska hemoglobin från
DNA FRÅN BLOD & KINDCELLER
EQUALIS Användarmöte, Molekylärdiagnostik 2012 Quality Hotel, Ekoxen, Linköping 7 8 november, 2012 DNA FRÅN BLOD & KINDCELLER Majid Osman, kemist, PhD Klinisk kemi, Linköping DNA stabilitet Provtagning
B-Hemoglobin, DiaSpect (NPU28309)
Klinisk kemi Sid 1(5) Bakgrund, indikation och tolkning Hemoglobinhalten i blod är direkt proportionell mot antalet erytrocyter. Alla störningar i erytropoesen leder till sänkt antal erytrocyter och därmed
Immunteknologi, en introduktion. Hur man använder antikroppar för att mäta eller detektera biologiska händelser.
Immunteknologi, en introduktion Hur man använder antikroppar för att mäta eller detektera biologiska händelser. Antikroppar genereras av b-lymphocyter, som är en del av de vita blodkropparna Varje ursprunglig
Några vanliga laboratorieanalysers referensintervall för friska gravida
2008-07-07 Några vanliga laboratorieanalysers referensintervall för friska gravida Referensintervall är viktiga när vi skall bedöma analysresultat. Vi saknar idag referensintervall för normal graviditet.
Patientmedian. Equalis allmän kemi-möte tors 15 nov Peter Ridefelt, Klinisk kemi och farmakologi, Akademiska sjukhuset
Patientmedian Equalis allmän kemi-möte tors 15 nov 2018 Peter Ridefelt, Klinisk kemi och farmakologi, Akademiska sjukhuset Graham Jones, Chemical Pathology, SydPath, St Vincent s Hospital, Sydney, Australia
Glattmuskel laboration
Glattmuskel laboration Introduktion: Syftet med laborationen är att ta reda på hur potenta alfa- antagonisterna Prazosin och Yohimbin är genom att tillsätta stigande koncentration av agonisten noradrenalin
Analysera gifter, droger och läkemedel med högupplösande vätskekromatografi (HPLC) Niklas Dahrén
Analysera gifter, droger och läkemedel med högupplösande vätskekromatografi (HPLC) Niklas Dahrén GC och HPLC GC= gas chromatography eller på svenska gaskromatografi. HPLC= high performance liquid chromatography
Lab-perspektiv på Lupusträsket. Maria Berndtsson, Karolinska Universitetslaboratoriet
Lab-perspektiv på Lupusträsket Maria Berndtsson, Karolinska Universitetslaboratoriet Bakgrund Diagnostik Komplicerande faktorer Externkontroller Framtid/förbättringar 2 Lab-perspektiv på Lupusträsket Vad
Viktigt säkerhetsmeddelande
ADVIA Centaur ADVIA Centaur XP ADVIA Centaur XPT ADVIA Centaur CP CC 19-4.A-1.OUS December 218 Enligt våra uppgifter kan ditt laboratorium ha mottagit följande produkt: Table 1. ADVIA Centaur berörd produkt
HbA1c på Architect c 8000
HbA1c på Architect c 8000 Klinisk kemi Uddevalla sjukhus Ombyggnad av Architect c8000 Ny provprob där isoleringen är kortare. Ombyggnad av Architect c8000 Ombyggnad av provprobens tvättstation med extra
Glukosdehydrogenas. Laktos och Galaktos. Enzymatisk bestämning i livsmedel
Glukosdehydrogenas Laktos och Ga. Enzymatisk bestämning i livsmedel Innehållsförteckning 1. Ändamål och Användningsområde...1 2. Princip...1 3. Reagens...1 3.1 Citratbuffert...1 3.2 NAD-Citratbuffert...2
Laboratorienytt. Innehåll:
LABORATORIEMEDICIN Laboratorienytt Nr 1, januari 2011 Innehåll: 1 Innehållsförteckning 1-2 Remisser till Laboratoriemedicin VL 2-5 Klinisk Kemi Automation B-PEth. Fosfatidyletanol i blod Patientnära bestämning
Rening, inmärkning och användning av ett målprotein
Rening, inmärkning och användning av ett målprotein Protein A / Fc co-crystal complex Protein A domain Antibody Protein A binding Protein A domain CH 3 CH 2 Deisenhofer 1981 Upplägg av labben Framtagning
Tentamen i Biomedicinsk laboratoriemetodik 2, 7 hp (kod 0800)
Tentamen i Biomedicinsk laboratoriemetodik 2, 7 hp (kod 0800) Kursens namn: BMLVA II 22,5 högskolepoäng Kurskod: BL1004 Kursansvarig: Charlotte Sahlberg Bang Datum: 14 januari -2012 Skrivtid: 240 min Totalpoäng:
MISSBRUKSDIAGNOSTIK Klinisk kemisk diagnostik HT 2016 Elisabeth Hjortswang
MISSBRUKSDIAGNOSTIK Klinisk kemisk diagnostik HT 2016 Elisabeth Hjortswang Missbruk delas upp i narkotikamissbruk och alkoholmissbruk. NARKOTIKAMISSBRUK Kommer från grekiskans narkotikos som betyder sömn,
Immunanalys VANKOMYCIN-KALIBRATORER Förklaring till symboler som används
0155185-C December, 2009 QMS VANKOMYCIN Immunanalys Denna bipacksedel till det kvantitativa mikrosfärssystemet (QMS - Quantitative Microsphere System) måste läsas noggrant före användning. Instruktionerna
Jonbyteskromatografi
Jonbyteskromatografi Den mest frekvent använda proteinreningsmetoden Bygger på laddad interaktion mellan målproteinet i lösning och en fast matris. Beroende av:! Lösningens ph! Målproteinet och kontaminanternas
Kromatografi. Kromatografi. Kromatografi. Användningsområde. Den kromatografiska processen. Typer av kromatografi. Separation.
Kromatografi Kromatografi Ämne A Ämne B eparation Identifiering Tswett, kromatografi, början 900-t artin & ynge, fördeln.krom., 940-t James & artin, GC, 950-t nyde, ber mfl, PLC, 970-t mg Kvantifiering
Kursplan för kursen Bioanalytisk HPLC, [NAKE006] engelsk titel: Bioanalytical HPLC
KURSPLAN Datum 201X-XX-XX Diarienummer U 201X/XXX Kursplan för kursen Bioanalytisk HPLC, [NAKE006] engelsk titel: Bioanalytical HPLC Kursplanen är fastställd av fakultetens nämnd för utbildning på forskarnivå
OBS! Under rubriken lärares namn på gröna omslaget ange istället skrivningsområde, ex Lösningsberedning. Totalt ska ni använda 9 gröna omslag.
BL1015, BMLV A, biomedicinsk laboratoriemetodik, 7,5hp. Prov 0101, H14. Kursansvarig: Siw Lunander Datum: 2014-11-22 Skrivtid: 4 timmar Totalpoäng: 51 p Lösningsberedning, 15 poäng Spektrofotometri, 5
Coatest SP Factor VIII 82 4086 63 Swedish revision 12/2004
AVSETT ÄNDAMÅL Kitet är avsett för fotometrisk bestämning av faktor VIII-aktivitet i plasma, antikoagulerad med citrat vid diagnostisering av FVIII-brist eller för monotorering av patienter i substitutionsterapi
Institutionen för laboratoriemedicin Bilaga 2 Biomedicinska analytikerprogrammet Analytisk Kemi och Biokemisk metodik Ht 2010, Termin 3
Institutionen för laboratoriemedicin Bilaga 2 Biomedicinska analytikerprogrammet Analytisk Kemi och Biokemisk metodik Ht 2010, Termin 3 Laborationsdatum: 17 22 november 2010 Grupp: 2 Projekt: Rening och
BRÅDSKANDE SÄKERHETSMEDDELANDE TILL MARKNADEN
2 november 2012 BRÅDSKANDE SÄKERHETSMEDDELANDE TILL MARKNADEN Upphörande, VITROS Chemistry Products HPT reagens artikelnummer: 6802214 Bäste kund Som en del av en s.k. korrigerande säkerhetsåtgärd på marknaden,
Fysisk aktivitet och hjärnan
1 Fysisk aktivitet och hjärnan Professor Ingibjörg H. Jónsdóttir Hälsan och stressmedicin, VGR Institutionen för kost och idrottsvetenskap Göteborgs Universitet Kvinnlig simultankapacitet troligen en myt
ABX Pentra Creatinine 120 CP
2010/12/09 A93A01276ASV A11A01933 27.5 ml 8 ml 400 Användningsområde: Diagnostiskt reagens för kvantitativ in vitro-bestämning av kreatinin i serum, plasma och urin med hjälp av kolorimetri. Klinisk betydelse
Hög-känslig troponin ett kliniskt perspektiv. Kai Eggers Kardiolog Kliniken Akademiska sjukhuset
Hög-känslig troponin ett kliniskt perspektiv Kai Eggers Kardiolog Kliniken Akademiska sjukhuset Schematic representation of the cardiac myofibrillar thin filament detectable after 3-9 hours Korff S, et
Tennorganiska föreningar i sediment. Christina Tina Kindeberg
The The first first slide Tennorganiska föreningar i sediment Christina Tina Kindeberg Tennorganiska föreningar Analyserade tennorganiska föreningar TBT TrPhT MBT DPhT Monobutyltenn, MBT Dibutyltenn, DBT
TENTAMEN KEMISK MÄTTEKNIK (KD1110), 2009-01-12
TENTAMEN KEMISK MÄTTEKNIK (KD1110), 2009-01-12 OBS! Använd ett ark per uppgift. Skriv namn på varje ark. OBS! För varje uppgift anges maximalt antal poäng. För godkänt resultat fordras 40 poäng. En sjugradig
Harmonisering av Fosfatidyletanol (PEth) Expertgruppen Läkemedel/Toxikologi
Harmonisering av Fosfatidyletanol (PEth) Expertgruppen Läkemedel/Toxikologi PEth 16:0 18:1 EQUALIS användarmöte för Läkemedel/Toxikologi 21-22 Mars 2013 Stockholm Harmoniseringar 1) Harmonisering av U-Kreatinins
) / (c l) -A R ) = (A L. -ε R. Δε = (ε L. Tentamen i Biomätteknik (TFKE37), 9 januari Uppgift 1 (10p)
Tentamen i Biomätteknik (TFKE37), 9 januari 2014. Uppgift 1 (10p) För akronymerna FT- IR, AUC, AFM, UV och MALDI: a) Skriv ut förkortningen! b) Föreslå för varje metod två egenskaper hos biomolekyler som
Aborter i Sverige 2008 januari juni
HÄLSA OCH SJUKDOMAR 2008:9 Aborter i Sverige 2008 januari juni Preliminär sammanställning SVERIGES OFFICIELLA STATISTIK Statistik Hälsa och Sjukdomar Aborter i Sverige 2008 januari juni Preliminär sammanställning
Kromatografi. Idag
Lärarfortbildning 2019-05-07 Marie Danielsson 08 790 97 32 marie.danielsson@vetenskapenshus.se Idag Inledning - kromatografi Extraktion av växtfärgämnen Pappers- och tunnskiktskromatografi Fika Kolonnkromatografi
Fruktosamin. Ett alternativ när HbA1c är i bekymmer. Niclas Rollborn Laboratorieingenjör, Akademiska sjukhuset
Fruktosamin Ett alternativ när HbA1c är i bekymmer Niclas Rollborn Laboratorieingenjör, Akademiska sjukhuset HbA1c - Metodik Kromatografiskt HPLC-system (MonoS, Biorad, Tosoh) Kapillärelektrofores (Capillarys)
Preanalytisk hållbarhet. Peter Ridefelt - Klinisk kemi och farmakologi, Akademiska sjukhuset
Preanalytisk hållbarhet Peter Ridefelt - Klinisk kemi och farmakologi, Akademiska sjukhuset Walter Guders sammanställningar http://www.diagnosticsample.com Stahl Clin Chem Lab Med 2005;43:210 Jensen Clin
Bättre bas för klinisk bedömning och samarbete
Per Simonsson, docent, verksamhetschef, klinisk kemi, Universitetssjukhuset MAS, Malmö; ordförande i Svensk förening för klinisk kemi och i Nordisk förening för klinisk kemi (per.simonsson@klkemi.mas.lu.se)
Viktig produktsäkerhetsinformation
2010-11-17 Viktig produktsäkerhetsinformation Access Total BhCG För användning på Access Immunoassay System Artikelnummer 33500 Access Total βhcg Lotnummer Alla Bästa Beckman Coulter Access Total βhcg
Immunometoder för serum digoxin analys
Immunometoder för serum digoxin analys Hur exakta och mätsäkra är de? Michèle Masquelier, Klinisk Pharmakologi CHEM: /DGNI Metoder Kemi Digoxin analys jämförelse 2 lab 3 metoder 6 5 4 y = 1,1318x - 0,3691
Tentamen i matematisk statistik
Sid 1 (9) i matematisk statistik Statistik och kvalitetsteknik 7,5 hp Tillåtna hjälpmedel: Miniräknare. Studenterna får behålla tentamensuppgifterna. Skrivtid: 9.00-12.00 ger maximalt 24 poäng. Betygsgränser:
Koncentrationsbestämning med hjälp av spädningsteknik och spektrofotometri
Umeå universitet Biomedicinska Analytikerprogrammet Koncentrationsbestämning med hjälp av spädningsteknik och spektrofotometri Årskull: Laborationsrapport i Grundläggande laboratorievetenskap, termin 1
Nya biomarkörer för diagnostik av tidig ovarialcancer; studier på cystvätskor och blod
Nya biomarkörer för diagnostik av tidig ovarialcancer; studier på cystvätskor och blod Karin Sundfeldt Docent Kvinnokliniken Sahlgrenska Akademin vid Göteborgs Universitet Ovarialcystor/cancer Diagnostik
Tentamen i Klinisk kemisk diagnostik 13 maj 2016 Skrivtid: 8:00-12:00
Kod:... Tentamen i Klinisk kemisk diagnostik 13 maj 2016 Skrivtid: 8:00-12:00 Personlig identifierare: Läs detta först: 1. Skriv din kod på varje blad! 2. Mobiltelefoner (tysta!), väskor och ytterkläder
Validering av kolonn för analys av alkoholer och glykoler med gaskromatografi
Validering av kolonn för analys av alkoholer och glykoler med gaskromatografi Jämförelse av två kolonner samt fortsatt validering för klinisk tillämpning Emelie Boström Examensarbete, 15 hp Biomedicinsk
Syns du, finns du? Examensarbete 15 hp kandidatnivå Medie- och kommunikationsvetenskap
Examensarbete 15 hp kandidatnivå Medie- och kommunikationsvetenskap Syns du, finns du? - En studie över användningen av SEO, PPC och sociala medier som strategiska kommunikationsverktyg i svenska företag
ACCESS Immunoassay System. HIV combo QC4 & QC5. För övervakning av Access HIV combo-analysens systemprestanda. B71124A - [SE] - 2015/01
ACCESS Immunoassay System HIV combo QC4 & QC5 B22822 För övervakning av Access HIV combo-analysens systemprestanda. - [SE] - 2015/01 Access HIV combo QC4 & QC5 Innehållsförteckning 1 Avsedd användning...
Utvärdering av IVIG behandling vid post-polio syndrom. Kristian Borg
Utvärdering av IVIG behandling vid post-polio syndrom Kristian Borg Div of Rehabilitation Medicine, Karolinska Institutet and Danderyd University Hospital Stockholm Sweden Pågående denervation som kompenseras
CHANGE WITH THE BRAIN IN MIND. Frukostseminarium 11 oktober 2018
CHANGE WITH THE BRAIN IN MIND Frukostseminarium 11 oktober 2018 EGNA FÖRÄNDRINGAR ü Fundera på ett par förändringar du drivit eller varit del av ü De som gått bra och det som gått dåligt. Vi pratar om
egfr hos barn Peter Ridefelt
egfr hos barn Peter Ridefelt Klinisk kemi och farmakologi, Akademiska sjukhuset Uppsala Inst f medicinska vetenskaper, klinisk kemi, Uppsala Universitet Referensintervall egfr formler absolut GFR Iohexol
Thermo. Shandon Cytospin Collection Fluid ELECTRON CORPORATION. Rev. 3, 09/03 P/N 238422
Shandon Cytospin Collection Fluid Thermo ELECTRON CORPORATION Anatomical Pathology USA Clinical Diagnostics 171 Industry Drive Pittsburgh, PA 15275, USA Tel: 1-800-547-7429 +1 412 788 1133 Fax: +1 412
Ökat personligt engagemang En studie om coachande förhållningssätt
Lärarutbildningen Fakulteten för lärande och samhälle Individ och samhälle Uppsats 7,5 högskolepoäng Ökat personligt engagemang En studie om coachande förhållningssätt Increased personal involvement A
Analys av D-dimer på patient med misstänkt HAMA
Analys av D-dimer på patient med misstänkt HAMA Susanne Samuelsson Legitimerad Biomedicinsk analytiker, Sektionsledare Klinisk Kemi, Koagulationslaboratoriet Sahlgrenska Universitetssjukhuset, Sahlgrenska,
CMV/EBV Molekylär diagnostik. Annika Allard Klinisk Mikrobiologi/Virologi Norrlands Universitetssjukhus
CMV/EBV Molekylär diagnostik Annika Allard Klinisk Mikrobiologi/Virologi Norrlands Universitetssjukhus De flesta CMV infektioner hos immunkompetenta individer är asymtomatiska eller ger bara en mkt mild
Sammanställning över alternativ till etidiumbromid
1 (6) Sammanställning över alternativ till etidiumbromid I nedanstående tabeller har leverantörerna VWR, Invitrogen och Sigma-Aldrich lämnat uppgifter om produkter/n de saluför som alternativ till etidiumbromid.
Validering och Verifiering: Vad är det och hur bör det utföras? Kerstin Elvin EQUALIS användarmöte 18 april 2013
Validering och Verifiering: Vad är det och hur bör det utföras? Kerstin Elvin EQUALIS användarmöte 18 april 2013 Vad är det????? Validering Engelskans validate göra giltigt, bekräfta. Validering fastställer
Att mäta och förbättra dialysvården över tid
Att mäta och förbättra dialysvården över tid Exempel från dialysenheten på Länssjukhuset Ryhov, Jönköping Dan Enell, Mark Splaine, Johan Thor 13 maj, 2013 Syften 1. Att visa hur man kan använda mätningar
Vad är värdet/faran med att operera tidigt? Sofia Strömberg Kärlkirurg Sahlgrenska Universitetssjukhuset
Vad är värdet/faran med att operera tidigt? Sofia Strömberg Kärlkirurg Sahlgrenska Universitetssjukhuset Symtomgivande Karotisstenos Naturalförloppet vid symptomgivande karotisstenos Results: There were
Analysera gifter, droger och läkemedel med gaskromatografi (GC) Niklas Dahrén
Analysera gifter, droger och läkemedel med gaskromatografi (GC) Niklas Dahrén Både GC och HPLC är vanliga analysmetoder GC= gas chromatography eller på svenska gaskromatografi. HPLC= high performance liquid
Lö sningsfö rslag till tentamen i matematisk statistik Statistik öch kvalitetsteknik 7,5 hp
Sid 1 (10) Lö sningsfö rslag till tentamen i matematisk statistik Statistik öch kvalitetsteknik 7,5 hp Uppgift 1 Betrakta nedanstående täthetsfunktion för en normalfördelad slumpvariabel X med väntevärde
S-IGF1, isys, IDS Malmö
1(7) S-IGF1, isys, IDS Malmö Bakgrund, indikation och tolkning IGF-1 är en proinsulinliknande molekyl som består av en peptidkedja om 70 aminosyror med 3 disulfidbryggor. Molekylvikten är 7 649 Da. IGF-1
KEM M06. Analytisk kemi Avancerad kurs 15 hp HT 09. Av Lars Erik Andreas Ehnbom. Föreläsare Dr. Margareta Sandahl Prof.
KEM M06 Analytisk kemi Avancerad kurs 15 hp HT 09 Av Lars Erik Andreas Ehnbom Föreläsare Dr. Margareta Sandahl Prof. Jan-Åke Jönsson Föreläsningarna delas in i ett antal delar: KF = kromatografiföreläsningar
What Is Hyper-Threading and How Does It Improve Performance
What Is Hyper-Threading and How Does It Improve Performance Ali Muthanna, Lunds Universitet, IDA2, EDT621 Abstract Hyper-Threading (HT) is Intel s version of simultaneous multi-threading (SMT). Hyper-Threading
TENTAMEN. Analytisk kemi (KD1120),
TENTAMEN Analytisk kemi (KD1120), 2009-03-12 OBS! Använd ett ark per uppgift. Skriv namn på varje ark. OBS! För varje uppgift anges maximalt antal poäng. För godkänt resultat fordras 28 poäng. En sjugradig
KOL med primärvårdsperspektiv ERS 2014. Björn Ställberg Gagnef vårdcentral
KOL med primärvårdsperspektiv ERS 2014 Björn Ställberg Gagnef vårdcentral Nationella programrådet Astma och KOL Identifierade insatsområden Nationella programrådet Astma och KOLinsatsområden för KOL Diagnostik,
Meddelande 6/2011. Från Unilabs Laboratoriemedicin Sörmland. Klinisk mikrobiologi
Datum 2011-11-0? Meddelande 6/2011 Från Unilabs Laboratoriemedicin Sörmland. Klinisk mikrobiologi Förenklad provtagning för Mycoplasma genitalium Separat rör för Mycoplasma genitalium, PCR (DNA) utgår
Separation av plasmaproteiner med elektrofores, HYDRAGEL PROTEIN(E) K20
Umeå Universitet Biomedicinska analytikerprogrammet Separation av plasmaproteiner med elektrofores, HYDRAGEL PROTEIN(E) K20 Årskull: Laborationsrapport i Klinisk laboratoriemetodik 1, termin 4 Laborationsdatum:
Tentamen i Immunteknologi 28 maj 2003, 8-13
Tentamen i Immunteknologi 28 maj 2003, 8-13 1 Varje fråga ger maximalt 5 p. 2 SKRIV NAMN OCH PERSONNUMMER PÅ ALLA SIDOR! 3 Glöm inte att lämna in KURSUTVÄRDERINGEN! Observera att i kursutvärderingen för
Statistisk undersökning och jämförelser mellan några volumetriska kärl. XXXXXXX
Statistisk undersökning och jämförelser mellan några volumetriska kärl. XXXXXXX Prov för nivå Väl Godkänd i statistik/kvalitetskontroll 1c) Gör de beräkningar som krävs för bestämning av validitet och
INTRODUKTION Intern kontroll
INTRODUKTION Intern kontroll Först en påminnelse om hur viktigt det är med dagliga interna kontroller. Med era patientnära instrument kan ni snabbt få svar på en frågeställning utan att först skicka proverna
Det kliniska värdet av små M-komponenter
Det kliniska värdet av små M-komponenter Mattias Aldrimer, överläkare Klinisk Kemi och Transfusionsmedicin Laboratoriemedicin i Dalarna Vad är en liten M-komponent? Ingen M-komponent i serum och/eller
Utvärdering av rosa glukosrören
Utvärdering av rosa glukosrören Ian Jones Kem lab Falun Rutin mätmetoder för glukos Glukosoxidas (1963) Glukos + O 2 Glukonsyra + H 2 O 2 Amperometrisk detektion Clarke elektrod (tex Yellow Spring, Blodgasinstrument)
Yttrande med anledning av Översyn av de nationella kvalitetsregistren. Guldgruvan i hälso-och sjukvården. Förslag till gemensam satsning 2011-2015
Uppsala 2011-03-14 1 (1) Socialdepartementet registrator@social.ministry.se s.hs@social.ministry.se Yttrande med anledning av Översyn av de nationella kvalitetsregistren. Guldgruvan i hälso-och sjukvården.