PNSPO! Xpectia kommunikation till OMRON PLC via Ethernet. 14 mars 2012 OMRON Corporation

Relevanta dokument
PNSPO! Tips! Xpectia kommunikation till OMRON PLC via Seriellt. 14 mars 2012 OMRON Corporation

PNSPO! CP1W-CIF mars 2012 OMRON Corporation

OMRON. PLC till PLC kommunikation (CP1L-E) Ethernet. 22 april 2014 OMRON Corporation

OMRON. Ethernet-kommunikation mellan CP1L-E och HMI. Ethernet. 22 april 2014 OMRON Corporation

PNSPO! Minneskort till CJ. 14 mars 2012 OMRON Corporation

PNSPO! Programöverföring via CP1W-ME05M. 14 mars 2012 OMRON Corporation

PNSPO! Använda NJ med NS System Memory. 14 mars 2012 OMRON Corporation

PNSPO! CF-korts hantering till NS-serien. 14 mars 2012 OMRON Corporation

PNSPO! Adressering i Omrons PLC. 14 mars 2012 OMRON Corporation

PNSPO! PLC Backup Tool. 14 mars 2012 OMRON Corporation

WAGO IO System Service Seminar. Diagnostik

PNSPO! Tips! CP1W-AD och DA. 14 mars 2012 OMRON Corporation

Detta dokument beskriver enbart konfigurering av FX3U-ENET för att programmera/monitorera via Ethernet.

Styrsystem M580. Användare tips för Modicon M580. Skapad: Rev

Utförande: I exemplet så kommer vi att utgå från att man gör laborationen i en Virtuell miljö (Virtualbox).

Kontrollsystem HACCP WEB Tool 1. Användarmanual

Topologi. Utförande: I exemplet så kommer vi att utgå från att man gör laborationen i en Virtuell miljö (Virtualbox).

Fjärruppkoppling med MRD Industriell 3G-Router KI00282A

B60 Domäncentral B60 används i system vid fler än 10 st. dörrmiljöer och/ eller VAKA-bokning.

Ethernet kommunikation med hjälp av optionskortet OPT-CI

B60 Domäncentral. Installationsanvisning Se för de senaste manualerna.

Concept V2.6. Quantum. Programmering via modem

MRD Industriell 3G-Router KI00283C

Ethernet TCP/IP. Quantum, Premium och Momentum. Modemkommunikation mellan PC och ett Ethernet TCP/IP nätverk

BIPAC-711C2 / 710C2. ADSL Modem / Router. Snabbstart Guide

*1 Alternativ lösning Serial/IP COM Port Redirector v4.8 from tacticalsoftware.com För mer info se

Paneler - VCPXX.2. Programmeringsmanual för VCP-paneler. Revision 2

Använda bärbar dator som operatörspanel

SkeKraft Bredband Installationsguide

Installation och setup av Net-controller AXCARD DS-202

Instruktion för installation av etikettskrivare 2.31

Instruktion för installation av etikettskrivare 2.27

Din guide till. Klientinstallation MS Driftservice

Quick start manual. Smart-House Rev 1.1

RUTINBESKRIVNING FÖR INSTALLATION AV KAMERA

Lathund - Konfiguration av PLC och dator

Snabbguide IP-kamera Kom igång med din kamera

Passersystem VAKA 10

ÅTVID.NET Startinstruktioner

Aktivera och använda EtherTalk för Mac OS 9.x. Om du använder EtherTalk behövs ingen IP-adress för Macintosh-datorer.

Innehåll i detta dokument

3. Steg för steg. Kör IPv6 på riktigt med FortiGate! Principen är enkel:

B60 Domäncentral. Installationsanvisning Från v.3.60.xx Se för de senaste manualerna.

Kom igång med Etikettskrivaren 1. Ladda ner följande installationsprogram Ladda ner Drivrutiner för etikettskrivare Zebra

Konfigurera Routern manuellt

Styrsystem. SoMachine TM241 / 251. Kom-igång med SoMachine projekt. Skapad: Rev

GIVETVIS. SKA DU HA INTERNET I DIN LÄGENHET! En guide till hur du installerar internet i ditt nya hem.

C64 4G-router 4G-router för VAKA fjärradministration, IP-porttelefoni och internetbokning.

Beijer Electronics AB 2000, MA00336A,

Instruktioner för Internetanslutning

VAKA 10 Passersystem Driftsättning & Snabbstart

Installationsguide / Användarmanual

Övningar - Datorkommunikation

CoDeSys 2.3.x.x Svensk installationsguide

Quick start manual. Smart-House Rev 2.0

Aktivera och använda EtherTalk för Mac OS 9.x

Ladda upp filer fra n PLC till PC

Konfigurera Routern manuellt

P400 Installationsguide programversion

BRUKSAVISNING EASY GSM

LAN Port: 4 X RJ45 10/100BASE-TX Fast Ethernet med Auto MDI/MDIX. Resetknapp: Återställer enheten till fabriks inställningar

KOM IGÅNG GUIDE e!cockpit Av Carsten Holm

Hur man ändrar från statisk till automatisk tilldelning av IP i routern.

irule Status Statusindikering i irule utan feedback från enhet. Skapat av: Pär Skärlund, Sydia Teknik AB

porta KNX gateway Välkommen till en ny dimension av säkerhet Installation-och programmeringsmanual

Effektbrytare. Compact NSX och kommunikation. Kom-igång med kommunikation till effektbrytare Compact NSX

Blackboard learning system CE

Passersystem VAKA 10

Startanvisning för Bornets Internet

Programmera Avant 5 med PC mjukvara

Manual Sportident Onlinekontroll via GPRS

Modbus. WAGO Contact SA TSS STR

Inlämningsuppgift 11e Nätvärksskrivare

Handbok för installation av programvara

GIVETVIS. SKA DU HA INTERNET I DIN LÄGENHET! En guide till hur du installerar internet i ditt nya hem.

Allmänt. Välkommen till SVENSKA VÅGs datorprogram för räknevägning på PC.

Konfigurera Xenta från Babs

Om konsolporten. Beskrivning av portarna

Macintosh EtherTalk-nätverk (MacOS 8.x/9.x/X, version 10.1)

DCS-950G SECURICAM nätverk g trådlös internetkamera med ljud.

Monitor Pro V7 SCADA. Kom-igång med kommunikation Unitelway TCP/IP

Modbus över Ethernet. WAGO Contact SA TSS STR

Snabbinstallationsguide. Interact Pro.

Larmsändare sip86. Alla inställningar konfigureras enkelt upp med Windowsprogramvaran IP- Scanner. 2 Larmsändare sip22

Ethernet-anslutning. För mer information om skrivarens Ethernet-funktion klickar du på avsnittet nedan: Ethernet-lampor. nätverkskonfigurationssida

Detta är en guide för snabbinstallation av IP kameran För fullständig programfunktion hänvisar vi till medföljande manual.

progecad NLM Användarhandledning

Win95/98 Nätverks Kompendium. av DRIFTGRUPPEN

EDS1130 IP-kamera. Snabbguide. Svenska Version 1.0

BIPAC-7402 / 7402W (Trådlös) ADSL VPN Firewall Router med 3DES-accelerator Snabbstartsguide

Styrsystem. SoMachine TM241 / 251. Kom-igång med SoMachine projekt. Skapad: Rev

Passersystem VAKA 10

5 Internet, TCP/IP och Tillämpningar

Quickstart manual. Rev SHTOOL Quickstart manual Smart-House

TOX-serien med CDC. Hur de används och programmeras. Ref: Ref:

TOX-serien med CDC. Hur de används och programmeras. Ref: 56430x Ref:

Handbok för nätverk. För säker och korrekt användning, läs igenom säkerhetsinformationen i "Handbok för kopiator" innan du använder maskinen.

ipad och VNC Viewer KI*****

Instruktioner för uppdatering av enheter med ISP

Transkript:

PNSPO! Xpectia kommunikation till OMRON PLC via Ethernet 14 mars 2012 OMRON Corporation

2/27

Läs detta innan du bläddrar vidare PNSPO! Denna bok är avsedd som ett tillägg till de ursprungliga manualerna för OMRONs produkter. Använd den som en hjälp att få kännedom om produkterna och inte som ett recept för en färdig installation. Boken uppdateras kontinuerligt - se Revision i rubriken Denna bok är gjord för att användaren inte ska gå på alla klassiska fällor. För varje produkt som nämns i boken finns det flera manualer, som alltid är vettiga att läsa, för att få full kännedom om produkten! Observera att denna bok inte är en fullständig manual! Omron ansvarar inte för eventuella fel eller brister som kan uppstå. Kunden är ansvarig för konsekvenserna av dess användning. 3/27

INNEHÅLLSFÖRTEKNING Anledningen till den här guiden... 5 Produkter som stöds i den här guiden... 5 Ethernet... 5 Ethernet/IP (tag data link kommunikation)... 5 Förutsättningar... 5 Kommunicera via PLC Link kommunikation... 5 Kommunikations flödet för PLC Link... 6 Flödesschema över PLC Link kommunikationen... 6 Kommunikations inställningar i Xpectia (Ethernet PLC Link)... 7 1. Inställning av Startupp statusen [Startupp inställning]... 7 1. IP inställningar för kommunikationen... 9 2. Utgångs inställningar i Xpectian...12 Kommunikations inställningar i PLC (Ethernet)...14 Förutsättningar...14 1. Kommunikations inställning för CJ2M-CPU3x EIP...15 2. Kommunikations inställning för CJ1x-CPUxx ETN...16 5. Kommunikations inställning för CP1W-CIF41...17 PLC exempel program...20 1. I/O i PLC...20 2. PLC program 1 (One shot trigger)...20 3. PLC program 2 (Byt scen)...22 Bilaga 1 Minnesallokering (PLC Link)...25 1. Command Area...25 2. Response Area...26 3. Output Area...27 4/27

Anledningen till den här guiden Den här guiden är ett hjälp dokument för att på ett enkelt sätt vissa hur man sätter upp kommunikation till ett OMRON PLC, via Ethernet och seriell anslutning. För mer och djupare information vänlig se original manualerna. Produkter som stöds i den här guiden Ethernet Seriens namn CPU CPU inbyggd port Gränssnitt Ethernet enhet SYSMAC_CJ2 CJ2H O CJ1W-EIP21 (Bara PLC link), CJ1W-ETN21 SYSMAC_CJ1 CJ1H, CJ1G - CJ1W-EIP21 (Bara PLC link), CJ1W-ETN21 CJ1M *Inbyggd typ CJ1W-EIP21 (Bara PLC link), CJ1W-ETN21 endast SYSMAC_CS1 CS1H,CS1D,CS1G - CS1W-EIP21 (Bara PLC link), CS1W-ETN21 CP1L - CP1W-CIF41 SYSMAC_CP1 CP1H - CP1W-CIF41 CP1E * Med options korts CP1W-CIF41 (v2.0) möjlighet SYSMAC_One NSJ *Inbyggd typ endast NSJW-ETN21 Ethernet/IP (tag data link kommunikation) Seriens namn CPU CPU inbyggd port Gränssnitt Ethernet/IP enhet SYSMAC_CJ2 CJ2M,CJ2H *Inbyggd typ endast CJ1W-EIP21 SYSMAC_CJ1 CJ1H, CJ1G - CJ1W-EIP21 CJ1M *Inbyggd typ endast CJ1W-EIP21 SYSMAC_CS1 CS1H,CS1D,CS1G - CS1W-EIP21 OBS! Vid kommunikation till en Ethernet/IP enheter, måste EDS filen som innehåller kommunikations informationen för Xpectia installeras i Network Configurator. Förutsättningar En PC-dator som har både Seriell/USB- eller Ethernet-anslutning till ett Omron PLC. Omron CX-One V3.x eller V4.x installerad och uppdaterad med CX-One Auto Update Utility. CX-One innehåller programmeringsmjukvaran CX-Programmer som är till för att konfigurera och programmera OMRONS PLCsystem. Kommunicera via PLC Link kommunikation Detta avsnitt förklarar hur du ställer in nödvändiga kommunikation specifikationer, samt användnings formatet vid användning av PLC Link för att kommunicera med externa enheter. 5/27

Kommunikations flödet för PLC Link Kommunikationen mellan PLC och Xpectia utförs med hjälp av 3 link områden: Command area, Response area och Data output area. Command area används för att skicka styrkommandon från PLC till Xpectia. Response area utför resultatet av styrkommando koden från Command area. Data output area skriver ut valda mätningsresultaten från Xpectia till PLC. Flödesschema över PLC Link kommunikationen 6/27

Kommunikations inställningar i Xpectia (Ethernet PLC Link) Innan man gör inställningar för kommunikationsspecifikationerna, ställ in Serial (Ethernet) kommunikationsmodulen till PLC link (SYSMAC CS/CJ/CP/One ), spara inställningarna och starta om systemet genom att bryta strömmen till Xpectia. När systemet har startat om, är kommunikationsinställningarna initierade. 1. Inställning av Startupp statusen [Startupp inställning] 1. På huvudskärmen trycker du [System] menyn [Controller] [Startup setting]. 2. Under fliken [Communication] ändra [Serial(Ethernet)] till [PLC link (SYSMAC CS/CJ/CP/One)]. 7/27

Kommunikations modul Serial (Ethernet) Serial (RS-232C/RS-422) Parallel Fieldbus Inställningsvärdet [Fabriksinställning] [Normal (UDP)] Normal (TCP) Normal (UDP) (Fxxx series method) PLC link (SYSMAC CS/CJ/CP/One) PLC link (Mitsubishi) [Normal] Normal(Fxxx series method) PLC link(sysmac CS/CJ/CP/One) PLC link(mitsubishi) [Standard Parallel I/O] [OFF] EtherCAT EtherNet/IP Beskrivning Specifies the communication module. Serial/Ethernet Normal/Normal (Fxxx series method): Communication is performed with external devices through Normal communication. For differences between Normal and Normal (Fxxx series method), see the following Reference. PLC Link: Communication is performed via a link area with the PLC. Parallel Standard Parallel I/O: Communication is performed via a standard parallel interface. Fieldbus: Communication is performed via EtherCAT communication and EtherNet/IP. EtherCAT is valid only when FZM1 controller is used. OBS! Ställ inte in EtherNet/IP eller EtherCAT och PLC link på samma gång. De kan inte användas samtidigt. Ställ inte in PLC link på både Serial (Ethernet) och Serial (RS-232C/422). De kan inte användas samtidigt. 3. Klicka på OK 4. Viktigt att spara ner inställningarna. 5. Starta om Xpectian genom att bryta strömmen. 8/27

1. IP inställningar för kommunikationen 1. På huvudskärmen trycker du [System] menyn [Communication] [Ethernet: PLC Link(SYSMAC CS/CJ/CP/One)]. 2. Ställ in valfri IP adress för Xpectian och för PLC. Adress setting är IP adressen för Xpectian och Input/Output setting är PLC adress. I detta Exemplet för Ethernet: Adress setting IP addres: 192.168.11.100 Subnet mask: 255.255.255.0 I detta exemplet har dessa två adresserna inte ändrats: [Default gateway: 10.5.5.110 DNS server: 10.5.5.1] Input/Output setting Output IP adress: 192.168.11.242 Input/Output port no: 9600 9/27

3. Klicka på [PLC link setting]. PLC Link fönstret öppnas. 4. Ställ in följande: I Exemplet för Ethernet: Command: CIO 1200 Response: CIO 1300 Data output: CIO 1400 Inställning Inställningsvärdet [Fabriksinställning] Beskrivning Command area Response area Data output area Area [CIO Area (CIO)] Work Area(WR) Holding Bit Area(HR) Auxiliary Bit Area(AR) DM Area (DM) EM Area(EMO) Ställ in Command området. Adress 0 to 99999 [0] Ställ in start adressen för Command området. Area [CIO Area (CIO)] Work Area(WR) Holding Bit Area(HR) Auxiliary Bit Area(AR) Ställ in Response området. DM Area (DM) EM Area(EMO) Adress 0 to 99999 [100] Ställ in start adressen för Response området. Area [CIO Area (CIO)] Work Area(WR) Holding Bit Area(HR) Auxiliary Bit Area(AR) Ställ in Data output området. DM Area (DM) EM Area(EMO) Adress 0 to 99999 [200] Ställ in start adressen för Data output området. 10/27

Output control None [Handshaking] Ange om eller inte att ge en förregling med PLC när du utför en data output. None: Data skickas oberoende av status av signalerna från PLC. GATE är alltid AV. Handshaking: Data skickas när signalen DSA[Data output request bit] kommer från PLC. Retry intervall [ms] 1000 to 999999 [10000] Ställ in kommunikationens omförsöks tidsintervall OBS! Vid första triggnings tillfället tar det en stund innan Xpectian svarar PLCet. Retry intervalls tiden + beräknings tiden av en mätning (enbart första triggnings tillfället). 5. Klicka på OK Inställningarna har bekräftats och Ethernet-fönstret stängs. 11/27

2. Utgångs inställningar i Xpectian Efter alla inställningar ovan har gjorts i Xpectian, ska applikationen skapas. Den delen är inte beskriven här. Men efter att applikationen har skapats måste man välja vilka värden man vill skicka till PLC. 1. I slutet av din applikation måste en Data Output läggas till. 2. Öppna Data Output. Här har du möjligheten till att lägga in 8 olika mätnings värde som du sedan kan skicka till PLC. 12/27

PNSPO! 3. Under fliken Output format ställs kommunikations formatet in för vilken typ av utgång som skall användas. Ethernet eller RS-232C/422. I detta exemplet är Ethernet och Floating point inställt. Informationen kommer att visas enligt följande beroende på inställningarna ovan. Ex. Xpectia Fixed point Floating point Out0:10.0000 CIO140 = 10000 CIO140 = 10.000 Out1:20.0000 CIO142 = 20000 CIO142 = 20.000 Out2:30.0000 CIO144 = 30000 CIO144 = 30.000 13/27

Kommunikations inställningar i PLC (Ethernet) Kommunikations inställningarna för CJ och CP1 serien skiljer sig lite. Men det kommer i lätta drag förklaras här hur inställningen av IP adressen går till. För mer information refereras till manualerna för respektive produkt. För mer detaljerad uppsättning av CP1 seriens Ethernet modul (CP1W-CIF41) rekommenderas tips dokumentet: Tips! CP1W-CIF41 SWE v1.10 eller högre som finns att hitta på Downloads på www.myomron.com Förutsättningar En del förkunskap om OMRONS Ethernet uppsättning. En PC-dator som har både Seriell/USB- eller Ethernet-anslutning till ett Omron PLC. Omron CX-One V3.x eller V4.x installerad och uppdaterad med CX-One Auto Update Utility. CX-One innehåller programmeringsmjukvaran CX-Programmer som är till för att konfigurera och programmera OMRONS PLCsystem. 14/27

1. Kommunikations inställning för CJ2M-CPU3x EIP 1. Starta programmerings verktyget CX-Programmer. Start\Program\OMRON\CX-One\CX-Programmer 2. Skapa ett nytt projekt med en CJ2M-CPU3x (CPU31-35 har inbyggd EthernetIP) 3. Ställ in IP adressen för CJ2M i IO Table. OBS! Sista segmentet i din IP Address kommer att bli ditt NODE nr! I detta fallet är NODE nr 242. 15/27

4. Gå Online till PLC och välj att Transfer All när du ska ladda ner information till PLC. PNSPO! 2. Kommunikations inställning för CJ1x-CPUxx ETN 1. Starta programmerings verktyget CX-Programmer. Start\Program\OMRON\CX-One\CX-Programmer 2. Skapa ett nytt projekt med en CJ1 serie PLC. 3. Gå in i IO Table, lägg till ett CJ1W-ETN21(Ethernet kommunikations kort) och ställ in IP adressen för CJ1. OBS! Sista segmentet i din IP Address kommer att bli ditt NODE nr! I detta fallet är NODE nr 242. 16/27

4. Gå Online till PLC och välj att Transfer All när du ska ladda ner information till PLC. PNSPO! 5. Kommunikations inställning för CP1W-CIF41 1. Starta programmerings verktyget CX-Programmer. Start\Program\OMRON\CX-One\CX-Programmer 2. Skapa ett nytt projekt med en CP1 serie PLC. 3. I CX-Programmer, gå till "Settings" i projektet fönstret och ändra inställningarna på den seriella porten. Ställ in porten till att köra Omron ToolBus protokollet och överföringshastighet ska vara 115,2 Kbps: 4. På CP1L/H kan också tvångs styra porten till Toolbus genom DIP-switch 4 på (höger). På CP1L/H med två options portar kan man tvångs styra port 1 till Toolbus genom DIP-switch 4 och på port 2 genom DIP-switch 5. KOMIHÅG: Att bryta strömmen till PLC:et efter förändring. 17/27

PNSPO! 5. Öppna sedan programmerings verktyget CX-Integrator genom att trycka på Tools ->Network Settings i CX- Programmer. 6. Ett nätverk nummer måste tilldelas åt serieport när CIF41 är ansluten. Tryck på Tools -> Start Routing table. Här vissas också adressen på vilken options port CIF41 hamnar i CP1L/H: 7. Ändringar av CIF41 inställningar (t.ex. IP adress) görs via en webbläsare. Öppna en webbläsare (Internet Explorer, Mozilla Firefox etc) och ange IP-adressen för CIF41 kort (standard är IP-adressen 192.168.250.1): OBS! IP måste skrivas in 192.168.250.1/e00.htm Standardlösenordet är ETHERNET. Om detta inte fungerar, kontrollera att din dator har samma IP-segment som PLC. I detta exempel måste PC ha en IP adress i området 192.168.250.X, där X även kallas för IP-pool och måste vara inom 1-255 (Ping kommandot kan också användas för att kontrollera om datorn och PLC:en ligger inom samma område). 18/27

8. För att ändra IP adress i CIF41, gå till System : Gör om IP adressen och node numret (192.168.11.242 och använd sista segmentet som NODE nr(242)) och tryck Transfer. Därefter tryck på Restart. Kommunikationen faller pga att IP adressen på PC och PLC inte längre är i samma område. Detta är allt som behövs ställas in för CIF41 i ett enkelt Ethernet nätverk. 19/27

PLC exempel program 1. I/O i PLC Om alla inställningar av PLC-Link areorna gjorts som beskrivet i detta tips dokument kommer följande bitar och ord hamna på följande adresser: X_CMD_EXE BOOL 1200.00 Command executute bit X_CMD_DSA BOOL 1201.00 Command data output request bit X_RESP_FLG BOOL 1300.00 Response completion bit X_RESP_BUSY BOOL 1300.01 Response execution in progress bit X_RESP_GATE BOOL 1301.00 Response data output completion bit X_OUTPUT_DATA_0 REAL 1400 Output data 0 X_OUTPUT_DATA_1 REAL 1402 Output data 1 X_OUTPUT_DATA_2 REAL 1404 Output data 2 X_OUTPUT_DATA_3 REAL 1406 Output data 3 X_OUTPUT_DATA_4 REAL 1408 Output data 4 X_OUTPUT_DATA_5 REAL 1410 Output data 5 X_OUTPUT_DATA_6 REAL 1412 Output data 6 X_OUTPUT_DATA_7 REAL 1414 Output data 7 För mer information angående dessa bitar och ord va vänligen se Bilaga 1 Minnesallokering 2. PLC program 1 (One shot trigger) PLC programmet som vissas i detta exemplet är samma om du kör Ethernet som Seriellt. I detta exemplet kommer XPECTIA att ta ett foto och skicka resultatet till PLC när mätningen är färdig 20/27

1. Första cykel varvet kommer inställningar skickas ner till Xpectian så att den vet att vi ska köra one shot trigger. #1010 till 1202(Command area) och #10 till 1203(Command area) = Mätning utförs 1 gång. W0.00 startar triggningen i detta exemplet (skall vara hög så länge man vill ha mätningen) 2. Här triggas mätningen 21/27

OBS! Första triggnings tillfället tar så lång tid som omförsök tidsintervallet är inställt på,+ beräknings tiden av en mätning. 3. Resultatet hämtas när mätningen har utfärdats. 4. Nu är PLC program till One shot trigning färdigt. 3. PLC program 2 (Byt scen) Vidare byggt på samma program som PLC program 1 (one shot trigger) fast nu vill vi också byta mellan scener. 22/27

1. Lägg till en ny rung, genom att höger klicka och tryck Insert Above eller Below 2. Nu vill vi när W0.00 är FRÅN och upp flanken på W0.01 kommer inställningar skickas ner till Xpectian för att berätta att vi ska byta Scen nummer. #1000 till 1202(Command area) och #0030 till 1203(Command area) = Byt Scen. Värdet i D1 flyttas till 1204 = Vilken Scen du vill köra. 3. En exekvering av Command executute bit måste göras för att få inställningarna ner i Xpectian. Vi gör detta genom att känna av ner flanken på vår byt scen bit W0.01 23/27

4. Vi lägger också till TRIGG biten (W0.00) i vårt första steg för att skicka ner till Xpectian att vi ska köra one shot trigger igen. Den lägger vi på upp flanken. För fler Command code s se manualen Z290-E1-0x sektion 7: Methods for Connecting and Communicating with External Devices 24/27

PNSPO! Bilaga 1 Minnesallokering (PLC Link) Detta avsnittet beskriver fördelningen för varje minnes område, command area, response area, och output area. (Utdrag från Xpectian manualen Z290-E1-04) 1. Command Area PLC till Xpectian. Start ord I/O 1200 25/27

2. Response Area Xpectian till PLC. Start ord I/O 1300 26/27

3. Output Area Xpectian till PLC. Start ord I/O 1400 27/27