Sida 1 (10) BYGGHANDLING GENERALKONSULT REV ANT ÄNDRINGEN AVSER SIGN DATUM FASTST A BÖVING&KINNMARK 08 14 07 35 K WSP, GÖTEBORG 031-727 25 72 M WSP, GÖTEBORG E SIDUS, ESKILSTUNA 016-18 35 50 V LEB, ESKILSTUNA 016-15 89 87 Hkpflj MALMEN GARNISONSVAKTEN OMBYGGNAD GARNISONSVAKT BYGGNAD 007 ALLMÄNNA FÖRESKRIFTER UPPDRAG NR UPPRÄTTAD AV DATUM FASTSTÄLLD 10045563 HEJ DATUM HANDLÄGGARE PROJEKTNR A/G KOPIA NR H 06-01-31 HANS-ERIK JOHANSSON 1004 3098 ANSVARIG K0043.007.03/33.001 REV
FORTIFIKATIONSVERKET Sid 2(10) RANGORDNING FÖRESKRIFTER FÖRESKRIFTER GÄLLER I NEDAN NÄMND ORDNING. BESKRIVNING MARK OCH HUS DETALJFÖRESKRIFTER PÅ ENSKILD DETALJ PÅ RESP. RITNING FÖRESKRIFTER I MARGINALEN PÅ RESP. RITNING ALLMÄNNA FÖRESKRIFTER LEVERANTÖRENS ANVISNINGAR BYGGNORMER FÖR DIMENSIONERING OCH UTFÖRANDE GÄLLER FÖLJANDE BESTÄMMELSER: BOVERKETS BYGGREGLER, BFS 1993:57 MED ÄNDRINGAR T.O.M. 2002:19 BOVERKETS KONSTRUKTIONSREGLER BKR 99, BFS 1993:58 MED ÄNDRINGAR T.O.M. BFS 2003:6. BOVERKETS HANDBOK BBK 04 KONSTRUKTION BOVERKETS HANDBOK BBK 04 MATERIAL, UTFÖRANDE, KONTROLL. BOVERKETS HANDBOK BSK 99. STÅLKONSTRUKTIONER. 1999 BOVERKETS HANDBOK. BSV 97 SNÖ- OCH VINDLAST, UTGÅVA 2 1997 BOVERKETS HANDBOK. BSF 1995:18 SVÄNGNINGAR, DEFORMATIONSPÅVERKAN OCH OLYCKSLAST RITNINGSMETODIK PARALLELLPROJEKTION ENLIGT SS032261. ALLMÄNNA FÖRUTSÄTTNINGAR FÖR BÄRANDE KONSTRUKTIONER KONTROLL GRUNDKONTROLL ENLIGT BKR SKALL DOKUMENTERAS AV ENTREPRENÖREN. TILLÄGGSKONTROLL ENLIGT FÖRESKRIFTER UNDER RESP. PUNKT.
FORTIFIKATIONSVERKET Sid 3(10) MÅTTKONTROLL PÅ RITNINGAR ANGIVNA MÅTT ÄR NOMINELLA. ENTREPRENÖREN SKALL FÖRE TILLVERKNING AV KONSTRUKTION ELLER VARA SOM ANSLUTER MOT BEF. KONSTRUKTION KONTROLLERA ATT VERKLIGA MÅTT STÄMMER MED PÅ RITNINGAR ANGIVNA MÅTT. AVVIKELSE SKALL MEDDELAS BESTÄLLAREN FÖR BESLUT OM ÅTGÄRD. LASTER EGENTYNGDER BESTÄMS AV AKTUELLT UTFÖRANDE BJÄLKLAG ψ VANLIG LASTANDEL BUND LAST FRI LAST KONC LAST ψ 1 LÅNGTIDS- Q K ψ=1 Q K KN/M 2 ψ ψ 1 Q K ψ=0 KN ANDEL KN/M 2 BJÄLKLAG 4 0.5 0.5 3 FLÄLKTRUM 1 3 0.5 0.5 5 SNÖLAST SNÖLAST BERÄKNAS ENLIGT BSV 97, UTGÅVA 2. SNÖLASTENS GRUNDVÄRDE S o =2.0 kn/m 2 LASTREDUKTIONS FAKTOR ψ =0.7 ψ 1 =0.2 VINDLAST VINDLAST BERÄKNAS ENLIGT BSV 97, UTGÅVA 2 REFERENSVINDHASTIGHET: TERRÄNGTYP: II V REF =24 M/S GEOKONSTRUKTIONER GEOTEKNISK KLASS II GEOTEKNISKA FÖRHÅLLANDEN FRAMGÅR AV MARKBESKRIVNING. GRUNDLÄGGNING MED SULOR/PLATTOR GRUNDTRYCKET HAR BEGRÄNSATS ENL. NEDAN MATERIAL DIM GRUNDTRYCKSVÄRDE BROTT LÅNGTID 100 kn/m 2 80 kn/m 2
FORTIFIKATIONSVERKET Sid 4(10) FYLLNINGAR FÖRUTSÄTTNINGAR FRAMGÅR AV MARKBESKRIVNING PLATSGJUTNA BETONGKONSTRUKTIONER MATERIALKVALITETER GENERELLT GÄLLER ATT BETONGKVALITETER ÄR ANGIVNA M.H.T STATISK UTNYTTJANDE. EXPONERINGSKLASSEN GER OFTA HÖGRE KVALITET. BYGGNADSDEL SÄKER LIVS- BTG- HETS- LÄNGDS KVAL KLASS KLASS UTF- KLASS EXPONERRINGS KLASS VCT EKV TÄCKANDEANMÄRKNING BTG-SKIKT (MM) GRUNDSULOR 2 L100 C32/40 I XC4+XF3 MAX 0.55 45 INVÄNDIGA GOLV 1 L50 C25/30 II XC1 MAX 0.6 20 UTVÄNDIGA KONSTRUKTIONER T.EX PLINTSKAFT FÖR SKÄRMTAK ÖVER RESERVKRAFT OCH SOCKLAR 2 L50 C32/40 I XD3+XF4 MAX 0.4 45 GENERELLT KLORIDKLASS CL 0.2 ANVÄNDBAR CEMENT, CEMENTHALT OCH HÖGSTA MÄNGD MINERALISKA TILLSATSMEDEL SKALL UPPFYLLA KRAV ENLIGT SS 137093 FÖR AKTUELL EXPONERINGSKLASS ARMERINGSKVAL: B 500 BT DÄR EJ ANNAT ANGES DIM TÄCK-SKIKT UK ARM I GOLV, VERT ARM I VÄGGAR OCH PELARE ÖK ARM I GOLV HOR ARM I VÄGGAR OCH PELARE BETONGKVALITET BETONGKVALITET C25/30 C32/40 C25/30 C32/40 8 10 12 16 15 25 15 25 15 25 25 400 250 600 400 800 550 900 350 250 550 350 700 500 800 550 400 850 550 1150 800 1300 500 350 750 500 1000 700 1150
FORTIFIKATIONSVERKET Sid 5(10) FORMAR VAL AV FORMTYP ENLIGT BYGGNADSBESKRIVNING. ENTREPRENÖREN ANSVARAR FÖR ALLA FORMKONSTRUKTIONER. FORMKONSTRUKTIONER DIMENSIONERAS FÖR FÖRVÄNTAT FORMTRYCK. UTÅTGÅENDE HÖRN FASAD MED TREKANTSLIST. FASBREDD ENLIGT BESKRIVNING. GJUTFOGAR GJUTFOGAR PÅ ANDRA STÄLLE ÄN DÄR DESSA ANVISNINGAR OCH RITNINGAR ANGER UTFÖRS I SAMRÅD MED KONTROLLANT ELLER KONSTRUKTÖR. HORISONTELLA GJUTFOGAR SKALL UTFÖRAS MED MYCKET GROV OCH OJÄMN YTA SAMT RENSAS FRÅN CEMENTSLAM OCH RENGÖRAS VÄL FÖRE FORTSATT GJUTNING. ARBETSFOGARS LÄGE OCH UTFORMNING SKALL BESTÄMMAS I SAMRÅD MED KONSTRUKTÖREN. INGJUTNINGSGODS PÅ K-RITNINGAR REDOVISAS: ALLT INGJUTNINGSGODS SOM TILLHANDAHÅLLS OCH MONTERAS AV BYGGNADSENTREPRENÖREN. MARKERAS ALLT INGJUTNINGSGODS SOM TILLHANDAHÅLLS AV ANNAN ENTREPRENÖR MEN MONTERAS AV BYGGNADSENTREPRENÖREN. MARKERAS ALLT ÖVRIGT INGJUTNINGSGODS SOM TILLHANDAHÅLLS OCH MONTERAS AV ANNAN ENTREPRENÖR REDOVISAS EJ. OMFATTNING FRAMGÅR AV RESP. KONSULTS RITNING. INGJUTEN VÄRMEISOLERING SKALL DRÄNERAS I U.K. MED PVC-RÖR φ 25 C 1500 MM. ENTREPRENÖREN SKALL MED HÄNSYN TILL DEN FÄRDIGA UTFORMNINGEN KONTROLLERA ATT ALLT INGJUTNINGSGODS FINNS I FORMEN FÖRE GJUTNING. FÖREBYGGANDE ÅTGÄRDER MOT SPRICKBILDNING ERFORDERLIGA ÅTGÄRDER FÖR ATT MINIMERA UPPKOMSTEN AV PLASTISKA KRYMPSPRICKOR SKALL VIDTAS ENLIGT BBK 94 8.5.2.4 TOLERANSER BYGGPLATSTOLERANSER ENLIGT BYGGNADSBESKRIVNING. ÖVRIGA BETONGARBETEN
FORTIFIKATIONSVERKET Sid 6(10) UNDERGJUTNING AV FOTPLÅTAR FÖR STÅL- OCH BETONGPELARE UTFÖRS MED FÖRTILLVERKAT EXPANDERANDE UNDERGJUTNINGSBRUK MED EGENSKAPER SOM UPPFYLLER KRAV ENLIGT BETONGHANDBOK ARBETSUTFÖRANDE, AVSNITT 30.8:1 VID FÖR UTFÖRANDET REPRESENTATIVA TEMPERATURFÖRHÅLLANDEN. UNDERGJUTNINGENS STENSTORLEK SKALL VARA ANPASSAD TILL UNDERGJUTNINGENS TJOCKLEK ENLIGT LEVERANTÖRENS ANVISNINGAR. HÄRDNING ENLIGT BETONGHANDBOK - ARBETSUTFÖRANDE, AVSNITT 30.7. KONTROLL TILLÄGGSKONTROLL ENLIGT SÄRSKILT UPPRÄTTAD KONTROLLPLAN. KONTROLLARBETET DOKUMENTERAS PÅ RESPEKTIVE RITNING SAMT I DAGBOK ELLER PROVNINGSJOURNAL. ALL DOKUMENTATION ARKIVERAS. ENTREPRENÖRENS ANSVARIGE BEKRÄFTAR MED SIN NAMNTECKNING KÄNNEDOM OM DENNA TILLÄGGSKONTROLL. BETONGGOLV I UTRYMMEN DÄR GOLVMATTOR UTFÖRS FÖRSÄNKS ÖK MED 5 MM. SPACKELMASSOR ENLIGT BESKRIVNING UTFÖRS I DESSA UTRYMMEN FÖ SE RITNINGAR. STÅLKONSTRUKTIONER ALLMÄNNA FÖRUTSÄTTNINGAR SÄKERHETSKLASS 3 FÖR STRÄVOR KORROSIVITETSKLASS INOMHUS UTOMHUS C1 C3 AVSEDD ANVÄNDNINGSTID 100 ÅR UTTRYCKET BÖR I BSK TOLKAS SOM SKALL FÖR TILLVERKANDE OCH/ELLER MONTERANDE FÖRETAG SOM INTE ÄR SBS ANSLUTNA. MATERIAL DÄR EJ ANNAT ANGES PROFIL KVALITET HEB, HEA, IPE S275JR L, T S235JRG2 VKR, KKR S355J2H OPT. 1.2, 1.7 UPE S355N PLÅT S355, J2 G3 OPT. 5.7 SVETSELEKTRODER 500D SKRUVAR
FORTIFIKATIONSVERKET Sid 7(10) O FÖRBANDSKLAS S S1 SKRUV SB 8.8 C FZV B MUTTER 8 FZV B ENLIGT SS- ISO 4032 BRICKA C FZV B GRUNDSKRUVAR D S355JR A) MATERIALET SKALL VARA SAMMANSATT SÅ ATT DET ÄR SVETSBART. ENBART BULTAR SOM ÄR AVSEDDA FÖR BULTSVETSNING ÄR GODTAGNA. DRAGPROVNING AV BULTMATERIAL SKALL UTFÖRAS MED FÄRDIGBEARBETADE BULTAR ENLIGT TILLÄMPLIGA DELAR AV SS-EN 10 002-1. B) FZV MIN F /ZN ENLIGT SS3192 C) SBI PUBLIKATION 172, BILAGA 1. OBS! BRICKA UNDER MUTTER OCH SKRUVSKALLE, DÄR EJ ANNAT ANGES. D) STÄLLMUTTER PÅ UNDERSIDA FOTPLÅT SKALL VARA HALVMUTTER. TILLVRKNINGSKONTROLLERAT STÅL ENLIGT BKR 99 1:4. SKRUVAR OCH MUTTRAR MED PROVNINGSINTYG TYP 3.1.B ENLIGT SS-EN 10 204 UTFÄRDAT AV TILLVERKAREN. OM PROV- NINGSINTYG SAKNAS SKALL PROVNING UTFÖRAS SOM EN DEL AV MOTTAGNINGS-KONTROLL ENLIGT BSK 9:641. UTFÖRANDE UTFÖRANDEKLASS GC SVETSKLASS SKÄRKLASS wc sk2 SKRUVFÖRBANDSKLASS s1 GÄNGLÄNGD SKALL BEAKTAS ENLIGT BSK 8:53 TILLVERKNING OCH MONTERING UTFÖRES UNDER LEDNING AV ANSVARIG PERSON MED DOKUMENTERAD KOMPETENS LÄGST MOTSVARANDE TYP TR STÅL/N. ALL SVETSNING UTFÖRES AV SVETSARE MED DOKUMENTERAD KOMPETENS ENLIGT SS 06 52 01 ELLER SS-RN 287-1. OM EJ ANNAT ANGES PÅ RITNINGAR SVETSAS STÅLANSLUTNINGAR MED KÄLSVETS MED A- MÅTT=4 ANSLUTNINGAR MED VKR-PROFILER SVETSAS DOCK MED STUMSVETS MED SVETSMÅTT= STÖRSTA ANSLUTANDE GODSTJOCKLEK. SVETSAR UTFÖRS PÅ BÅDA SIOR OCH RUNT OM. ÖPPNA ÄNDAR PÅ VKR-PROFILER UTFÖRS MED PLÅT T=6 MM SOM TÄTSVETSAS OM EJ ANNAT ANGIVES PÅ RITNINGAR. TOLERANSER ANGIVNA MÅTT ÄR TEORETISKA, TILLVERKAREN SKALL SJÄLV GÖRA ERFORDERLIGA TILLÄGG OCH AVDRAG FÖR SPALTER, KRYMPNING, SVETSFOGAR ETC.
FORTIFIKATIONSVERKET Sid 8(10) TILLVERKAREN ANSVARAR FÖR ATT DE TILLVERKADE ELEMENTEN KAN MONTERAS OCH SAMMANFOGAS PÅ PLATSEN. FÖR DEN FÄRDIGA KONSTRUKTIONENS TOLERANSER GÄLLER SBI PUBLIKATION 112, TOLERANSER FÖR STÅLKONSTRUKTIONER ROSTSKYDDSSYSTEM HÅLLBARHETSVÄRDE: HÖG (> 15 ÅR) KORROSIVITETSKLASS C1 C3 ROSTSKYDDSSYSTEM S1 S3 BETRÄFFANDE ROSTSKYDD SE ÄVEN BESKRIVNING. SYSTEM ANPASSAS TILL VALD TÄCKFÄRG ENLIGT BYGGNADSBESKRIVNING SE ÄVEN BESKRIVNING. BRANDSKYDD INVÄNDIGT STÅL BRANSKYDDAS I E 30 TILLFÄLLIG STABILISERING STAGNINGAR OCH FÖRBAND, STÄMPNING ETC REDOVISAS I MONTERINGSPLAN SOM UPPRÄTTAS I SAMRÅD MED KONSTRUKTÖREN. KONTROLL GRUNDKONTROLL SKALL UTFÖRAS ENLIGT BSK 9:6. GRUNDKONTROLL SKALL DOKUMENTERAS OCH RAPPORTERAS TILL BESTÄLLAREN INKL. DE FEL SOM UPPTÄCKTS OCH ÅTGÄRDATS. TILLÄGGSKONTROLL INGÅR OCH REDOVISAS ENLIGT SEPARAT KONTROLLPLAN. INFÄSTNINGAR DÄR EJ ANNAT ANGES FÖRBORRAS HÅL FÖR GÄNGFORMANDE SKRUV (TD-) OCH BLINDNIT ENLIGT LEVERANTÖRENS ANVISNINGAR. ÖVRIGT UNDERGJUTNING AV FOTPLÅTAR UTFÖRES INNAN BELASTNING PÅFÖRES. ARBETSMILJÖPLAN SE ADMINISTRATIVA FÖRESKRIFTER. ENTREPRENÖREN SKALL UPPRÄTTA ARBETSMILJÖPLAN ENLIGT FÖRESKRIFT I AFS 1994:52.
FORTIFIKATIONSVERKET Sid 9(10) ENTREPRENÖREN SKALL UPPRÄTTA EN PLAN FÖR HANTERING AV RESTPRODUKTER. FUKT DRÄNERING UNDER/MOT HUS DRÄNERING VID HUS SAMT DRÄNERINGSLEDNING UTFÖRS ENLIGT MARKBESKRIVNING. ÅNGSPÄRRAR UTFÖRS ENLIGT BYGGNADSBESKRIVNING. BYGGFUKT/UTTORKNING BYGGNADSENTREPRENÖREN VÄLJER LÄMPLIG METOD FÖR ATT NÅ UPPSTÄLLDA KRAV PÅ RELATIV FUKTIGHET M.H.T LÄGGNING AV GOLVBELÄGGNINGAR. (KRAV FRAMGÅR AV BYGGNADSBESKRIVNINGEN). FÄSTDON EXPANDERSKRUV EXPANDERSKRUV SKALL VARA HILTI HSA-F VARMFÖRZINKAD, OCH TYPGODKÄND OCH AVSEDD FÖR GENOMSTICKSMONTAGE. KEMISKT ANKARE KEMISKT ANKARE SKALL VARA VARMFÖRZINKAT OCH TYPGODKÄNT. BYGGSKRUV BYGGSKRUV SKALL VARA VARMFÖRZINKAD. TERMISK ISOLERING MINERALULL ANGIVNA NUMMER AVSER FABRIKAT PAROC MEN LIKVÄRDIG ISOLERING AV ANNAT FABRIKAT FÅR ANVÄNDAS. CELLPLAST CELLPLASTISOLERING SKALL VARA TILLVERKAD OCH TYPGODKÄND FÖR AVSETT ANVÄNDNINGSOMRÅDE. ANGIVNA PRODUKTER AV EXPANDERAD CELLPLAST (EPS) AVSER FABRIKAT PAROC MEN LIKVÄRDIG ISOLERING AV ANNAT FABRIKAT FÅR ANVÄNDAS. SYLLISOLERING SYLLISOLERING AV GUMMI SKALL MONTERAS ÖVERALLT I FASAD DÄR REGLAR FÄSTS MOT BETONG. BREDD ANPASSAS TILL RESPEKTIVE UPPLAGSBREDD. OM SPRINGOR ÖVERSTIGER 10 MM ERSÄTTS LISTEN MED DREVNINGSREMSA PÅ 0,2 MM PE-FOLIE. DREVNINGEN SKALL OMFATTA HELA BREDDEN.
FORTIFIKATIONSVERKET Sid 10(10) TAKPLÅT LEVERANTÖR UTFÖR DIMENSIONERING VILKET ÄVEN GÄLLER INFÄSTNINGAR BETECKNINGAR