REX 521 Skyddsrelä. Teknisk referensmanual, standardkonfigurationer

Storlek: px
Starta visningen från sidan:

Download "REX 521 Skyddsrelä. Teknisk referensmanual, standardkonfigurationer"

Transkript

1 Skyddsrelä

2

3 1MRS Utgiven: Version: A/ Skyddsrelä Innehåll 1. Säkerhetsinstruktioner Inledning Dokumentrevision Standardkonfigurationer HW-version: Basic Standardkonfiguration B Egenskaper Applikation Standardkonfiguration B Egenskaper Applikation HW-version: Medium Standardkonfiguration M Egenskaper Applikation Standardkonfiguration M Egenskaper Applikation HW-version: High/Sensors Standardkonfiguration H01 (Sensorer) Egenskaper Applikation Standardkonfiguration H Egenskaper Applikation Standardkonfiguration H Egenskaper Applikation Standardkonfiguration H Egenskaper Applikation Standardkonfiguration H Egenskaper Applikation Standardkonfiguration H Egenskaper Applikation Standardkonfiguration H Copyright 2004 ABB Oy, Distribution Automation, Vasa, FINLAND 3

4 Skyddsrelä 1MRS Egenskaper Applikation Blockdiagram för signalstyrning Digitalingångar Ingångsväljare Switchgrupper för ingångar (SWGRP) Ingångssignaler Funktionsblock i översiktsdiagrammet för signalvägar Funktionsblock Switchgrupper för utgångar (SWGRP) Utgångsväljare Andra funktioner beskrivna i signalöversiktsdiagrammen Spärrningsfunktionen (Lockout) Parametrisering av digitalingångar Väljare Återställning Grupp Blockering Triggning av störningsskrivaren Triggning av elkvalitetsmätningen Allmän utlösning Extern utlösning Återställning av spärrningsfunktionen Lokal-/Fjärrmanövrering Close enable Direktstyrning (Frånslagen/Tillslagen) Objektindikering Tidssynkronisering AR inhibit, AR on input, start AR BACTRL (Basvinkelkontroll) Logikingång Förregling Förreglingsalternativ Förinställningar Beskrivningar av funktionsblock Skyddsfunktioner , och > Io>, Io>> och Io>>> Io>->, Io>>-> och Io>>>-> >och -> U> och 3U>>

5 1MRS Skyddsrelä U< och 3U<< I2f> O->I Uo>, Uo>> och Uo>>> f1 och f SYNC Is2t n< I() I2> och I2>> I< FUSEF Ithdev> U1<U1U2> Manöverfunktionsblock I<->O CB I<->O IND1 och I<->O IND I<->O POS I<->O IND ALARM Mätning I Io Uo DREC U f PQE AI Tillståndsövervakning CB wear TCS MCS 3I MCS 3U TIME Elkvalitet PQ 3Inf PQ 3Unf Standardfunktioner Switchgrupper (SWGRP) Väljare

6 Skyddsrelä 1MRS Stationsexempel Applikationsexempel, Basic Utgående linje, Basic B Egenskaper Mätningsanslutningar Skyddsfunktioner Fasöverströmsskydd Jordfelsskydd Fasavbrottsskydd Termiskt överlastskydd Kopplingar och signalvägar Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Blockeringssignal till en inkommande ledning Blockeringssignal från ett nollpunktsspänningsrelä Brytarfelsskydd (Circuit-breaker failure protection) Övervakning av utlösningskrets (TCS) Övervakning av brytarslitage Indikering av frånskiljare eller jordningsfrånskiljare Inkommande matning, Basic B Egenskaper Mätningsanslutningar Skyddsfunktioner Överströmsskydd Jordfelsskydd Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Blockeringssignal mottagen från den utgående linjen Utgående blockeringssignal till överströmsreläet på uppspänningssidan Användning av jordfelssteget Io>>> för att lösa ut brytaren på transformatorns uppspänningssida Brytarfelsskydd (Circuit-breaker failure protection) Störningsskrivare Elkvalitet

7 1MRS Skyddsrelä 9.3. Transformatorledning, Basic B Egenskaper Mätningsanslutningar Skyddsfunktioner Fasöverströmsskydd Transformatorinkopplingsströmsstöt Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Blockeringssignal från mellanspänningsreläet på transformatorns sekundärsida Brytarfelsskydd (Circuit-breaker failure protection) Översikt av blockeringssignalerna Utgående linje, Basic B Egenskaper Mätningsanslutningar Skyddsfunktioner Återinkopplingsfunktion Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Definite Trip-larm till ett utgångsrelä Digitalingång för att initiera återinkopplingsfunktionen Applikationsexempel, Medium Utgående linje, Medium M Egenskaper Mätningsanslutningar Skyddsfunktioner Riktat jordfelsskydd Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Basvinkelstyrning via en digitalingång Utgående blockeringssignal till en inkommande ledning Utlösningslarmsignaler från överströms- och jordfelsskyddet Brytarfelsskydd (Circuit-breaker failure protection) Övervakning av utlösningskretsen (TCS)

8 Skyddsrelä 1MRS Inkommande matning, Medium M Egenskaper Mätningsanslutningar Skyddsfunktioner Överströmsskydd Nollpunktsspänningsskydd Anslutningar Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Startsignal från det andra nollpunktsspänningssteget frigör blockering Blockeringssignal mottagen från den utgående linjen Utgående blockeringssignal till överströms reläet på uppspänningssidan Utlösningssignal från det andra nollpunktsspänningssteget Sekundära inställningar för nollpunktsspänningsskyddet Brytarfelsskyddet (Circuit-breaker failure protection) Övervakning av utlösningskretsen (TCS) Utgående linje, Medium M Egenskaper Mätningsanslutningar Skyddsfunktioner Återinkopplingsfunktion Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Definite Trip-larm till ett utgångsrelä Digitalingång för att initiera återinkopplingsfunktionen Basvinkelstyrning via en digitalingång Applikationsexempel, High Inkommande matning, High H Egenskaper Mätningar Skyddsfunktioner Överströmsskydd Synkroniseringskontrollfunktionen

9 1MRS Skyddsrelä Anslutningar Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Blockeringsprincip Brytarfelsskyddet (circuit-breaker failure protection) Övervakning av utlösningskrets (TCS) Inkommande matning, High H Egenskaper Mätningsanslutningar Skyddsfunktioner Överströmsskyddet Anslutningar Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Blockeringssignal mottagen från den utgående linjen och sektioneringsbrytaren Blockeringssignal från steg -> till steg Brytarfelsskydd (Circuit-breaker failure protection) Övervakning av utlösningskrets (TCS) Sektioneringsbrytaren, High H Egenskaper Mätningar Skyddsfunktioner Överströmsskydd Synkroniseringskontrollfunktionen Anslutningar Skyddsignalens väg Indikerings- och manöveranslutningar Utgående linje, High H Egenskaper Mätningar Mätningsanslutningar Skyddsfunktioner Oriktat jordfelsskydd Återinkopplingsfunktion Anslutningar Skyddsignalens väg Indikerings- och manöveranslutningar

10 Skyddsrelä 1MRS Exempel Inkommande matning, High H Egenskaper Mätningar Skyddsfunktioner Överströmsskydd Jordfelsskydd Överspännings- och underspänningsskydd Anslutningar Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Blockeringssignal mottagen från den utgående linjen Utgående blockeringssignal till överströmsreläet på uppspänningssidan Användning av jordfelssteget Io>>> för att lösa ut brytaren på transformatorns uppspänningssida Brytarfelsskyddet (Circuit-breaker failure protection) Störningsskrivare Elkvalitet Mätfacket, High H Egenskaper Mätningar Skyddsfunktioner Nollpunktsspänningsskydd Överspännings- och underspänningsskydd Underfrekvensskydd Anslutningar Skyddsignalens väg Indikerings- och manöveranslutningar Exempel Störningsskrivare Elkvalitet Motorskydd, High H Egenskaper Mätningar Skyddsfunktioner Termiskt överlastskydd Startvakt för motor (rotorblockeringsskydd)

11 1MRS Skyddsrelä Kumulativ starttidsräknare Kortslutningsskyddet (grövre överströmssteget) Obalansskyddet Fasföljdsskydd Underströmsskydd Säkringsfelsskydd Tillståndsövervakning Funktionstidsräknare Anslutningar Skyddsignalens väg Indikerings- och manöveranslutningar Indikering av motorstatus Symbolförklaringar Referenser

12 Skyddsrelä 1MRS Säkerhetsinstruktioner! Farliga spänningar kan uppträda i kontakterna, trots att matningsspänningen är frånkopplad. Nationella och lokala elsäkerhetsföreskrifter skall alltid iakttas. Terminalen innehåller komponenter känsliga för statisk elektricitet. Terminalens hölje ska alltid jordas på vederbörligt sätt. Endast kompetenta elektriker har rätt att utföra installationer. Brott mot säkerhetsföreskrifterna kan leda till förlust av människoliv, personskada eller omfattande materiella skador. Brytning av sigillet på bakre panelen leder till att garantin upphör och korrekt funktion av reläet kan inte garanteras. 12

13 1MRS Skyddsrelä 2. Inledning I den här manualen finns beskrivningar av standardkonfigurationer för. I avsnitt 3 beskrivs olika standardkonfigurationers enskilda egenskaper, medan anslutningen av signaler och funktioner beskrivs i avsnitten 4 till 6. En kort sammanställning av de funktionsblock som finns i de olika standardkonfigurationerna i finns i avsnitt 7. Avsnitten 8, 9, 10, och 11 beskriver olika applikationsexempel. I tabell 2.-1 finns standardkonfigurationerna nämnda. Observera att det är funktionsblockens namn och inte IEC-namnen som används i funktionsblocksbeskrivningarna på cd:n Technical Descriptions of Functions (se Referenser på sidan 224). har följande hårdvaruversioner (HW): basic, medium, high och sensor. Standardkonfigurationsvarianten med sensor betecknas med bokstaven S i parametern Konfig. namn, t.ex. H02S. Dokumentrevision Version Revision Datum Utgångsversion A , Protection Relay, Technical Reference Manual, Standard Configurations, version E/ Olikheter mellan och plattformen RED 500 då det gäller beskrivningarna av funktionsblocken. Det finns vissa olikheter då det gäller beskrivningarna av funktionsblocken i REX 521 och plattformen RED 500 på cd:n Technical Descriptions of Functions (se Referenser på sidan 224). För det första är det vissa termer som hänför sig till andra produkter än och för det andra finns det egenskaper som endast ingår i, såsom Händelsemask 1 gäller endast SPA-kommunikation. Direkt styrning vid återinkoppling är inte tillåten. I standardkonfigurationerna av används ett begränsat antal ingångar och utgångar. 13

14 Skyddsrelä 1MRS Tabell 2.-1Standardkonfigurationer för Hårdvaruversioner Basic Medium High/Sensor Standardkonfiguration B01 B02 M01 M02 H01 1,6,7 H02 7 H03 6,7 H04 7 H05 7 H06 H07 Funktionsblock Funktionsblockets namn Apparats IEEEnummer Skyddsfunktioner NOC3Low 51 x x x x x x x x x x NOC3High 50/51 x x x x x x x x x x > NOC3Inst 50/51 x x x x x x x x x Io> NEF1Low 51N x x x 2 x x Io>> NEF1High 50N/51N x x x 2 x x Io>>> NEF1Inst 50N x x x 2 x Io>-> 4 DEF2Low 67N/51N x x x x x x x Io>>- -> 4 DEF2High 67N x x x x x x x Io>>>-> 4 DEF2Inst 67N x x x x x x -> DOC6Low 67 x x 3 x -> DOC6High 67 x x 3 3U> OV3Low 59 x x x 3U>> OV3High 59 x x x 3U< UV3Low 27 x x x 3U<< UV3High 27 x x x 3I2f> Inrush3 68 x x x x x x x x x CUB3Low 46 x x x x x x x x TOL3Cab 49F x x x x x x x x O->I AR5Func 79 x x x x x x Uo> ROV1Low 59N x x Uo>> ROV1High 59N x x Uo>>> ROV1Inst 59N x x f1 Freq1St1 81U/81O x x x x f2 Freq1St2 81U/81O x SYNC1 SCVCSt1 25 x x Is2t n< MotStart 48, 14, 66 x 3I() PREV3 46R x I2> NPS3Low 46 x I2>> NPS3High 46 x 3I< NUC3St1 37 x FUSEF FuseFail 60 x 3Ithdev> Tol3Dev 49M x U1<U1U2> PSV3St1 27, 47, 59 x Styrfunktioner I<->O CB1 COCB1 x x x x x x x x x x x I<->O IND1 COIND1 x x x x x x x x x x x I<->O IND2 COIND2 x x x x x x x x x x x I<->O IND3 COIND3 x 5 14

15 1MRS Skyddsrelä Tabell 2.-1Standardkonfigurationer för Hårdvaruversioner Basic Medium High/Sensor Standardkonfiguration B01 B02 M01 M02 H01 1,6,7 H02 7 H03 6,7 H04 7 H05 7 H06 H07 Funktionsblock Funktionsblockets namn Apparats IEEEnummer I<->O POS COLOCAT x x x x x x x x x x x ALARM1-8 MMIALAR1- x x x x x x x x x x x 8 Mätning 3I MECU3A x x x x x x x x x x x Io MECU1A x x x x x x x x x x x Uo MEVO1A x x x x x x x x x DREC MEDREC x x x x x x x x x x x 3U MEVO3A x x x x x x x F MEFR1 x x x x x x x PQE MEPE7 x x x x x x x AI1 MEAI1 x Tillståndsövervakning CB wear CMBWEAR1 x x x x x x x x x x x TCS1 CMTCS1 x x x x x x x x x x x MCS 3I CMCU3 x x x x x x x x x x x MCS 3U CMVO3 x x x x x x x TIME1 CMTIME1 x Elkvalitetsövervakning PQ 3Inf PQCU3H x x x x x x x x x x x PQ 3Unf PQVO3H x x x x x x x Standard SWGRP x x x x x x x x x x x 1 H01 finns endast i den sensorförsedda versionen av 2 Fast konfigurerad till kanalen I 0 (1/5 A) 3 -> och -> kan inte ställas in att fungera soms, eller > 4 Kan användas som funktionsblocken Io>, Io>> och Io>>> eller Uo>, Uo>> och Uo>>> med vissa begränsningar 5 Indikering av motorstatus 6 Beräknad Uo (Uos) används i sensorkonfigurationerna 7 Beräknad Io (Ios) ingår även 15

16 Skyddsrelä 1MRS Tabell 2.-2Skyddsfunktioner i olika standardkonfigurationer för Funktion Beskrivning Is2t n< Trefasig startövervakning för motorer Trefasigt oriktat överströmsskydd, lågströmssteg Trefasigt oriktat överströmsskydd, högströmssteg > Trefasigt oriktat överströmsskydd, momentant steg 3I() Strömmätande fasföljdsskydd Io> Oriktat jordfelsskydd, lågströmssteg Io>> Oriktat jordfelsskydd, högströmssteg Io>>> Oriktat jordfelsskydd, momentant steg Io>-> Riktat jordfelsskydd, lågströmssteg Io>>-> Riktat jordfelsskydd, högströmssteg Io>>>-> Riktat jordfelsskydd, momentant steg I2> Minusföljdsströmskydd, lågströmssteg I2>> Minusföljdsströmskydd, högströmssteg -> Trefasigt riktat överströmsskydd, lågströmssteg -> Trefasigt riktat överströmsskydd, högströmssteg 3I< Trefasigt underströmsskydd 3U> Trefasigt överspänningsskydd, finare steg 3U>> Trefasigt överspänningsskydd, grövre steg 3U< Trefasigt underspänningsskydd, finare steg 3U<< Trefasigt underspänningsskydd, grövre steg 3I2f> Trefasig transformatorstartströms- och motorstartströmsdetektor Fasavbrottsskydd Trefasigt termiskt skydd för kablar 3Ithdev Trefasigt termiskt överlastskydd för apparater O->I Återinkopplingsfunktion (5 steg) Uo> Nollpunktsspänningsskydd, finare steg Uo>> Nollpunktsspänningsskydd, grövre steg Uo>>> Nollpunktsspänningsskydd, momentant steg U1<U1U2> Spänningsmätande fasföljdsskydd f1 Underfrekvens- eller överfrekvensskydd, steg 1 f2 Underfrekvens- eller överfrekvensskydd, steg 2 FUSEF Skydd för säkringsfel SYNC Synkroniseringskontroll/spänningskontrollfunktion Tabell 2.-3Manöverfunktioner i olika standardkonfigurationer för Funktion Beskrivning I<->O CB1 Brytarkontroll med indikering I<->O IND1 Objektindikering I<->O IND2 Objektindikering I<->O IND3 Objektindikering I<->O POS Logikstyrd manöverlägesväljare ALARM1-8 Larmdioder

17 1MRS Skyddsrelä Tabell 2.-4Mätfunktioner i olika standardkonfigurationer för Funktion 3I Io Uo DREC 3U f PQE MEAI1 Beskrivning Trefasig strömmätning Mätning av nollpunktsström Mätning av nollpunktsspänning Störningsskrivare Trefasig spänningsmätning Mätning av systemfrekvens Trefasig effekt- och energimätning Analog mätfunktion Tabell 2.-5Tillståndsövervakningsfunktioner i olika standardkonfigurationer för Funktion Beskrivning CB wear Brytarslitage TCS1 Övervakning av utlösningskrets 1 MCS 3I Övervakning av strömmätkretsar MCS 3U Övervakning av spänningsmätkretsar TIME1 Funktionstidsräknare Tabell 2.-6Övervakning av elkvalitetetens tillstånd, funktion som ingår i olika standardkonfigurationer för Funktion Beskrivning PQ 3Inf PQ 3Unf Mätning av distorsionen i strömmens vågform Mätning av distorsionen i spänningens vågform 17

18 Skyddsrelä 1MRS Standardkonfigurationer 3.1. HW-version: Basic Standardkonfiguration B Egenskaper Trefasigt oriktat överströmsskydd med tre steg Oriktat jordfelsskydd med tre steg Trefasigt fasavbrottsskydd Trefasigt termiskt skydd för kablar Trefasig transformatorstartströms- och motorstartströmsdetektor Övervakning av strömmätkretsar Mätning av distorsionen i strömmens vågform Trefasig strömmätning Mätning av nollpunktsström Beräkning av ackumulerat brytarslitage Störningsskrivare Övervakning av utlösningskrets Fördröjd utlösningsutgång för brytarfelsskyddet () Brytarkontroll med indikering Spärrningsfunktion (Lockout) Objektindikering Logikstyrd manöverlägesväljare Ingångar och utgångar som kan konfigureras av användaren Förregling Larmlysdioder som kan konfigureras av användaren Ytterligare information om egenskaper, se avsnittet Beskrivningar av funktionsblock på sidan

19 1MRS Skyddsrelä Fig Blockschema för B01 B Applikation Standardkonfigurationen B01 är planerad att användas i system med en samlingsskena och en brytare för selektivt kortslutnings-, tidöverströms- och jordfelsskydd i radiella nät med isolerad nollpunkt eller nät med direktjordad, resistansjordad och resonansjordad nollpunkt. Närmare information finns i applikationsexemplen för B01 på sidorna 115, 128 och

20 Skyddsrelä 1MRS DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 DREC trig PQ 3Inf trig Master trip External trip Lockout reset O/C E/F PQ 3Inf O/C E/F X4.2.5/6 X4.2.6/7 X4.2.8/9 X4.2.9/10 X4.2.11/12 X4.2.13/14 X4.2.15/16 X4.2.17/18 X3.1.1/2 Reset 1 Reset 2 Group Blocking 1 Blocking 2 Remote Close enable Open Close Logic input 1 Logic input 2 Logic input 3 SWGRP BS2 BS2 BS2 > BS2 Io> BS2 Io>> BS2 Io>>> BS2 BS O/C E/F PQ 3Inf BS1 BS1 BS1 > BS1 Io> BS1 Io>> BS1 Io>>> BS1 Master trip External trip Lockout reset I<->0 POS I<->O CB1 CBO CBO SWGRP TCS BS DC1 DC1 I<->O IND1 DC2 DC2 ES1 ES1 I<->O IND2 ES2 ES2 Lockout Working Interlocking_A Interlocking_B Interlocking_C Interlocking_D Interlocking_E & I<->O CB1 3I2f START DOUBLE DOUBLE > 3I2f START 3I2f START BS1 BS1 BS1 > BS1 Io> BS1 Io>> BS1 Io>>> BS1 BS2 BS2 BS2 > BS2 Io> BS2 Io>> BS2 Io>>> BS2 BS BS1 BS2 GROUP RESET START TRIP BS1 BS2 BSOUT GROUP START DOUBLE TRIP RESET I<->O CB1 OPEN CLOSE CLOSEENA BINOPEN BINCLOSE I<->O IND1 BINOPEN BINCLOSE I<->O IND2 BINOPEN BINCLOSE OOPEN OCLOSE AOPEN ACLOSE > I<->O POS BS1 BS2 GROUP DOUBLE RESET Io> BSOUT START TRIP BS1 BS2 START GROUP TRIP RESET Io>> BS1 BS2 GROUP RESET Io>>> START TRIP BS1 BS2 START GROUP TRIP RESET 3I2f> 3I 2f /I1f> 3dI/dt> GROUP START BINREMOTE Io IL1 IL2 IL3 Io 3I IL1 DREC IL2 IL3 Io Uo BI1 Start BI2 Start BI3 Start > BI4 Start Io> BI5 Start Io>> BI6 Start Io>>> BI7 Start 3 BI8 Start BI9 Trip BI10 Trip BI11 Trip > BI12 Trip Io> BI13 Trip Io>> BI14 Trip Io>>> BI15 Trip 3 BI16 Trip EXT_TRG BS1 BS2 GROUP RESET BLOCK (BS) GROUP RESET 3DI> 3 J> Cab START TRIP START TRIP CU_ALARM CB wear OPEN ALARM BINOPEN BINCLOSE TCS1 TCSSTATE BS ALARM TRIGG RESET MCS 3I PQ 3Inf ALARM HAR_HIGH CUM_HIGH > Io> Io>> Io>>> Master Trip Open HSPO1 (X4.2.3/4/1/2) Trip 1 >1 >1 Lockout S HSPO1 Q Lockout reset R Lockout Working > Io> Io>> Io>>> > Io> Io>> Io>>> > Io> Io>> Io>>> > Io> Io>> Io>>> > Io> Io>> Io>>> > I<->0 CB1 open I<->0 CB1 close MCS 3I TCS1 PQ 3Inf har PQ 3Inf cum CB wear I<->0 CB1 open I<->0 CB1 close MCS 3I TCS1 PQ 3Inf har PQ 3Inf cum CB wear Trip 2 Trip 3 External trip Close Start 1 Start 2 Lockout BSOUT Alarm 1 Alarm 2 3I2f START PO1 (X4.1.12/13) PO2 (X4.1.14/15) PO3 (X4.1.17/18) SO1 (X4.1.8/7/6) 1 SO2 (X4.1.10/11/9) Start Trip Start Trip > Start > Trip Io> Start Io> Trip Io>> Start Io>> Trip Io>>> Start Io>>> Trip Start Trip Start Trip DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 MEAS_HI DI2 DI3 DI4 DI5 DI6 DI7 Interlocking MEAS LO ALARM MEAS HI ALARM DI3 DI4 DI5 DI6 DI7 Lockout Lockout Alarm LED1 Alarm LED2 Alarm LED3 Alarm LED4 Alarm LED5 Alarm LED6 Alarm LED7 CB wear Alarm LED8 TCS1 MCS 3I DI4 DI5 DI6 DI7 DI8 Fig Blockschema för standard konfiguration B01 i 20

21 1MRS Skyddsrelä Standardkonfiguration B Egenskaper Trefasigt oriktat överströmsskydd med tre steg Trefasig transformatorstartströms- och motorstartströmsdetektor Oriktat jordfelsskydd med tre steg Trefasigt fasavbrottsskydd Trefasigt termiskt skydd för kablar Övervakning av strömmätkretsar Mätning av distorsionen i strömmens vågform Trefasig strömmätning Mätning av nollpunktsström Beräkning av ackumulerat brytarslitage Störningsskrivare Övervakning av utlösningskrets Fördröjd utlösningsutgång för brytarfelsskyddet Automatisk återinkoppling steg Brytarkontroll med indikering Spärrningsfunktion (Lockout) Objektindikering Logikstyrd manöverlägesväljare Ingångar och utgångar som kan konfigureras av användaren Förregling Larmlysdioder som kan konfigureras av användaren 21

22 Skyddsrelä 1MRS Fig Blockschema för standardkonfiguration B02 B Applikation Standardkonfigurationen BO2 för är planerad för användning i system med en samlingsskena och en brytare för selektivt kortslutnings-, tidöverströms- och jordfelsskydd samt automatisk återinkoppling.konfigurationen kan användas i olika nät, t.ex. radiella nät med isolerad nollpunkt, direktjordade, resistansjordade eller resonansjordade nät. Närmare information om konfigurationen, se applikationsexemplen med standardkonfiguration B02 på sidan

23 1MRS Skyddsrelä SWGRP O/C Reset 1 E/F O/C E/F PQ 3Inf O-->I Reset 2 PQ 3Inf O/C O-->I DI1 Group E/F DI2 DI3 Blocking 1 DI4 BS1 DI5 BS2 BS1 DI6 BS2 BS1 > DI7 Blocking 2 BS2 > BS1 Io> DI8 BS2 Io> BS1 Io>> DI9 BS2 Io>> BS1 Io>>> BS2 Io>>> BS1 BS2 DREC trig BS PQ 3Inf trig O-->I INH O-->I ON O-->I O-->I Ext. start AR1 O-->I Ext. trip AR2 AR3 AR4 *) Master trip Master trip External trip External trip Lockout reset Lockout reset Remote Close enable Open I<->O CB1 Close SWGRP CBO CBO TCS BS DC1 DC1 I<->O IND1 DC2 DC2 ES1 ES1 I<->O IND2 X4.2.5/6 X4.2.6/7 X4.2.8/9 X4.2.9/10 X4.2.11/12 X4.2.13/14 X4.2.15/16 X4.2.17/18 X3.1.1/2 ES2 ES2 Logic input 1 Logic input 2 Logic input 3 CLOSEENA Interlocking_A I<->O CB1 & Interlocking_B Interlocking_C Interlocking_D Interlocking_E Lockout Working 3I2f START DOUBLE DOUBLE > BS1 3I2f START BS1 BS1 > BS1 Io> BS2 BS1 Io>> BS2 BS1 Io>>> BS2 > BS1 BS2 Io> BS2 Io>> 3I2f START BS2 Io>>> BS2 BS O-->I AR1 DEFTRIP AR2 LOCKOUT BS1 AR3 ROPEN BS2 AR4 START RCLOSE GROUP ARINH TRIP SHOT1 RESET CBOPEN SHOT2 CBCLOSE SHOT3 ON SHOT4 RESET SHOT5 AR1TRIP BS1 AR2TRIP BS2 BSOUT AR3TRIP GROUP START AR4TRIP DOUBLE TRIP CB FAIL RESET DEFTRIP LOCKOUT > TRDUE TDDUE ACTIVE BS1 SHOT_ALARM BS2 BSOUT GROUP START DOUBLE TRIP I<->O IND1 RESET BINOPEN BINCLOSE Io> I<->O IND2 BINOPEN BINCLOSE BS1 I<->O POS BS2 START GROUP TRIP BINREMOTE RESET Io>> Io Io 3I BS1 BS2 START IL1 GROUP TRIP IL2 RESET IL3 Io>>> IL1 DREC IL2 BS1 IL3 BS2 START Io GROUP TRIP Uo RESET BI1 Start BI2 Start 3I2f> BI3 Start > 3I 2f /I1f> BI4 Start Io> BI5 Start Io>> 3dI/dt> BI6 Start Io>>> GROUP START BI7 Start 3 BI8 Start BI9 Trip 3DI> BI10 Trip BI11 Trip > BI12 Trip Io> BS1 BI13 Trip Io>> BS2 START BI14 Trip Io>>> GROUP TRIP BI15 Trip 3 RESET BI16 Trip EXT_TRG 3 J> CB wear Cab OPEN ALARM BINOPEN BLOCK (BS) BINCLOSE GROUP START RESET TRIP TCS1 TCSSTATE CU_ALARM BS ALARM I<->O CB1 MCS 3I OOPEN OPEN OCLOSE ALARM OPENENA AOPEN CLOSE ACLOSE PQ 3Inf CLOSEENA BINOPEN TRIGG HAR_HIGH BINCLOSE RESET CUM_HIGH I<->O IND1 BINOPEN BINCLOSE Ropen Master Trip Open HSPO1 > (X4.2.3/4/1/2) Io> Trip 1 >1 >1 Io>> Lockout Io>>> S HSPO1 Q Lockout reset R Lockout Working > Io> Trip 2 1 Lockout Io>> Io>>> PO1 (X4.1.12/13) > Trip 3 Io> PO2 (X4.1.14/15) Io>> >1 Io>>> PO3 (X4.1.17/18) SO1 (X4.1.8/7/6) External trip SO2 (X4.1.10/11/9) > Io> Io>> Alarm LED1 Io>>> Start Trip Start Trip RCLOSE > Start Close > Trip ³1 CLOSE Alarm LED2 Io> Start > Start 1 Io> Trip Io> Io>> Start Io>> Io>> Trip Io>>> Io>>> Start Io>>> Trip > Start 2 Io> Io>> Start Alarm LED3 Io>>> Trip Lockout Start Trip BSOUT O->I OPEN > O->I ACTIVE O->I ALAR1 I<->0 CB1 open O->I ALAR2 I<->0 CB1 close Alarm 1 DI1 Alarm LED4 MCS 3I DI2 TCS1 DI3 PQ 3Inf har DI4 PQ 3Inf cum DI5 DI6 CB wear I<->0 CB1 open DI7 I<->0 CB1 close DI8 Alarm 2 MCS 3I DI1 Alarm LED5 TCS1 DI2 PQ 3Inf har DI3 SHOT1 PQ 3Inf cum DI4 SHOT2 CB wear DI5 DI6 SHOT3 DI7 SHOT4 O-->I Active DI8 SHOT5 TRDUE MEAS HI ALARM Alarm LED6 TDDUE DI2 ACTIVE DI3 DI4 AR1TRIP DI5 AR2TRIP DI6 AR3TRIP O-->I Alarm DI7 AR4TRIP 1 Interlocking CBFAIL DEFTRIP MEAS LO ALARM Alarm LED7 LOCKOUT MEAS HI ALARM SHOT_ALARM DI3 AR1TRIP DI4 DI5 AR2TRIP DI6 AR3TRIP DI7 AR4TRIP Lockout CBFAIL DEFTRIP O-->I Alarm 2 CB wear Alarm LED8 LOCKOUT TCS1 SHOT_ALARM MCS 3I DI4 3I2f START DI5 DI6 DI7 DI8 Fig Blockschema för standardkonfiguration B02 i ConfB02_a 23

24 Skyddsrelä 1MRS HW-version: Medium Standardkonfiguration M Egenskaper Trefasigt oriktat överströmsskydd med tre steg Trefasig transformatorstartströms- och motorstartströmsdetektor Riktat jordfelsskydd med tre steg Trefasigt fasavbrottsskydd Trefasigt termiskt skydd för kablar Övervakning av strömmätkretsar Mätning av distorsionen i strömmens vågform Trefasig strömmätning Mätning av nollpunktsström Mätning av nollpunktspänning Beräkning av ackumulerat brytarslitage Störningsskrivare Övervakning av utlösningskrets Fördröjd utlösningsutgång för brytarfelsskyddet Brytarkontroll med indikering Spärrningsfunktion (Lockout) Objektindikering Logikstyrd manöverlägesväljare Ingångar och utgångar (I/O) som kan konfigureras av användaren Förregling Larmlysdioder som kan konfigureras av användaren 24

25 1MRS Skyddsrelä Fig Blockschema för standardkonfiguration MO1 M Applikation Standardkonfigurationen M01 för är planerad att användas i system med en enkel samlingsskena och en brytare för selektivt kortslutnings-, tidöverströmsoch riktat jordfelsskydd i radiella nät med isolerad nollpunkt, direktjordade, resistansjordade eller resonansjordade nät. Närmare information om konfigurationen, se applikationsexemplen med standardkonfiguration M01 på sidan 154 och

26 Skyddsrelä 1MRS DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 Reset 1 Reset 2 Group Blocking 1 Blocking 2 DREC trig PQ 3Inf trig BACTRL Master trip External trip Lockout reset Remote Close enable Open Close CB pos. open CB pos. close DC pos. open DC pos. close ES pos. open ES pos. close X4.2.5/6 X4.2.6/7 X4.2.8/9 X4.2.9/10 X4.2.11/12 X4.2.13/14 X4.2.15/16 X4.2.17/18 X3.1.1/2 Logic input 1 Logic input 2 Logic input 3 SWGRP O/C E/F O/C E/F PQ 3Inf PQ 3Inf O/C E/F BS1 BS2 BS1 BS2 BS1 > BS2 > BS1 Io>--> BS2 Io>--> BS1 Io>>--> BS2 Io>>--> BS1 Io>>>--> BS2 Io>>>--> BS1 BS2 BS Io>--> Io>>--> Io>>>--> Master trip External trip Lockout reset I<->O CB1 SWGRP CBO CBO TCS BS DC1 DC1 I<->O IND1 DC2 DC2 ES1 ES1 I<->O IND2 ES2 ES2 Interlocking_A Interlocking_B Interlocking_C Interlocking_D Interlocking_E & CLOSEENA I<->O CB1 Lockout Working 3I2f START DOUBLE DOUBLE > 3I2f START 3I2f START BS1 BS1 BS1 > BS2 BS1 Io>--> BS2 BS1 Io>>--> BS2 > BS1 Io>>>--> BS2 Io>--> BS1 BS2 Io>>--> BS2 Io>>>--> BS2 BS I<->O CB1 OOPEN OCLOSE BS1 OPEN AOPEN BS2 START CLOSE ACLOSE GROUP TRIP CLOSEENA RESET BINOPEN BINCLOSE I<->O IND1 BINOPEN BS1 BINCLOSE BS2 BSOUT GROUP START I<->O IND2 DOUBLE TRIP BINOPEN RESET BINCLOSE > I<->O POS BINREMOTE BS1 BS2 BSOUT Io GROUP START Io DOUBLE TRIP 3I RESET IL1 Io> IL2 IL3 BACTRL BS1 START BS2 TRIP GROUP RESET Io>> BACTRLB S1 BS2 GROUP RESET Io>>> BACTRL BS1 BS2 GROUP RESET START TRIP START TRIP 3I2f> 3I 2f /I1f> 3dI/dt> GROUP START Uo Uo DREC IL1 IL2 IL3 Io Iob Uo BI1 Start BI2 Start BI3 Start > BI4 Start Io> BI5 Start Io>> BI6 Start Io>>> BI7 Start 3 BI8 Start BI9 Trip BI10 Trip BI11 Trip > BI12 Trip Io> BI13 Trip Io>> BI14 Trip Io>>> BI15 Trip 3 BI16 Trip EXT_TRG CB wear OPEN ALARM 3DI> BINOPEN BINCLOSE TCS1 BS1 BS2 START TCSSTATE GROUP TRIP BS ALARM RESET MCS 3I ALARM 3 J> Cab PQ 3Inf TRIGG HAR_HIGH BLOCK (BS) RESET CUM_HIGH GROUP START RESET TRIP CU_ALARM Master Trip Open > HSPO1 (X4.2.3/4/1/2) Io>--> Trip 1 Io>>--> >1 >1 Io>>>--> Lockout S HSPO1 Q Lockout reset R Lockout Working 1 Lockout > Io>--> Trip 2 Io>>--> Io>>>--> PO1 (X4.1.12/13) PO2 (X4.1.14/15) PO3 (X4.1.17/18) SO1 (X4.1.8/7/6) > Trip 3 Io>--> Io>>--> SO2 (X4.1.10/11/9) Io>>>--> Alarm LED1 Start Trip External trip Start Trip > Start > Trip > Io>--> Io>>--> Io>>>--> Alarm LED2 Io>-> Start Io>-> Trip Io>>-> Start Close Io>>-> Trip Io>>>-> Start Io>>>-> Trip > Io>--> Start 1 Start Alarm LED3 Io>>--> Trip Io>>>--> Start Trip > Io>--> Start 2 DI1 Alarm LED4 Io>>--> DI2 Io>>>--> DI3 DI4 DI5 Lockout DI6 DI7 BSOUT DI8 > DI1 Alarm LED5 DI2 I<->0 CB1 open DI3 I<->0 CB1 close DI4 DI5 MCS 3I Alarm 1 DI6 TCS1 DI7 PQ 3Inf har DI8 PQ 3Inf cum CB wear MEAS HI ALARM Alarm LED6 DI2 DI3 I<->0 CB1 open DI4 I<->0 CB1 close DI5 DI6 MCS 3I Alarm 2 DI7 TCS1 Interlocking PQ 3Inf har PQ 3Inf cum MEAS LO ALARM Alarm LED7 CB wear MEAS HI ALARM DI3 DI4 DI5 DI6 3I2f START DI7 Lockout CB wear Alarm LED8 TCS1 MCS 3I DI4 DI5 DI6 DI7 DI8 Fig Blockschema för konfiguration M01 i ConfM01_a 26

27 1MRS Skyddsrelä Standardkonfiguration M Egenskaper Trefasigt oriktat överströmsskydd med tre steg Trefasig detektering av inkopplingsströmsstöt för transformator och startström för motor Riktat jordfelsskydd med tre steg Trefasigt fasavbrottsskydd Trefasigt termiskt skydd för kablar Övervakning av strömmätkretsar Mätning av distorsionen i strömmens vågform Trefasig strömmätning Mätning av nollpunktsström Mätning av nollpunktspänning Beräkning av ackumulerat brytarslitage Störningsskrivare Övervakning av utlösningskrets Fördröjd utlösningsutgång för brytarfelsskyddet Automatisk återinkoppling steg Brytarkontroll med indikering Spärrningsfunktion (Lockout) Objektindikering Logikstyrd manöverlägesväljare Ingångar och utgångar (I/O) som kan konfigureras av användaren Förregling Larmlysdioder som kan konfigureras av användaren 27

28 Skyddsrelä 1MRS Applikation Fig Blockschema för standardkonfiguration MO2 Standardkonfigurationen M02 för är planerad för användning i system med en samlingsskena och en brytare för selektivt kortslutnings-, tidöverströms- och riktat jordfelsskydd för automatisk återinkoppling. Konfigurationen kan användas i olika nät, såsom i radiella nät med isolerad nollpunkt, direktjordade, resistansjordade eller resonansjordade nät. Närmare information om konfigurationen, se applikationsexemplen med standardkonfiguration M02 på sidan

29 1MRS Skyddsrelä SWGRP O/C Reset 1 E/F O/C E/F PQ 3Inf O-->I Reset 2 PQ 3Inf O/C O-->I DI1 Group E/F DI2 DI3 Blocking 1 DI4 BS1 DI5 BS2 BS1 DI6 DI7 BS2 BS1 > DI8 BS2 > BS1 Io>--> Blocking 2 DI9 BS2 Io>--> BS1 Io>>--> BS2 Io>>--> BS1 Io>>>--> BS2 Io>>>--> BS1 BS2 BS DREC trig PQ 3Inf trig O-->I INH O-->I ON O-->I O-->I Ext. start AR1 O-->I Ext. trip AR2 AR3 AR4 *) Io>--> BACTRL Io>>--> Io>>>--> Master trip Master trip External trip External trip Lockout reset Lockout reset Remote Close enable Open I<->O CB1 Close X4.2.5/6 X4.2.6/7 X4.2.8/9 X4.2.9/10 X4.2.11/12 X4.2.13/14 X4.2.15/16 X4.2.17/18 X3.1.1/2 SWGRP CBO CBO TCS BS DC1 DC1 I<->O IND1 DC2 DC2 ES1 ES1 I<->O IND2 ES2 ES2 Logic input 1 Logic input 2 Logic input 3 Interlocking_A Interlocking_B Interlocking_C Interlocking_D Interlocking_E & CLOSEENA I<->O CB1 Lockout Working 3I2f START DOUBLE DOUBLE > 3I2f START 3I2f START BS1 BS1 BS1 > BS1 Io>--> BS1 Io>>--> BS1 Io>>>--> BS1 BS2 BS2 BS2 > BS2 Io>--> BS2 Io>>--> BS2 Io>>>--> BS2 BS O-->I AR1 DEFTRIP AR2 LOCKOUT BS1 AR3 ROPEN BS2 START AR4 RCLOSE GROUP TRIP ARINH SHOT1 RESET CBOPEN SHOT2 CBCLOSE SHOT3 ON SHOT4 RESET SHOT5 AR1TRIP BS1 AR2TRIP BS2 BSOUT AR3TRIP GROUP START AR4TRIP DOUBLE TRIP CB FAIL RESET DEFTRIP LOCKOUT > TRDUE TDDUE ACTIVE BS1 SHOT_ALARM BS2 BSOUT GROUP START DOUBLE TRIP I<->O CB1 RESET OOPEN Io> OCLOSE OPEN AOPEN CLOSE ACLOSE CLOSEENA BACTRL BINOPEN BS1 START BINCLOSE BS2 TRIP GROUP I<->O IND1 RESET BINOPEN BINCLOSE Io>> I<->O IND2 BINOPEN BINCLOSE BACTRL START I<->O POS BS1 TRIP BS2 BINREMOTE GROUP RESET Io Io Io>>> 3I IL1 IL2 IL3 BACTRL START BS1 TRIP Uo BS2 Uo GROUP RESET DREC 3I2f> IL1 IL2 3I 2f /I1f> IL3 3dI/dt> Io GROUP START Iob Uo Start BI1 Start 3DI> BI2 Start BI3 > BI4 Start Io> BI5 Start Io>> BS1 BI6 Start BS2 START BI7 Io>>> GROUP TRIP BI8 Start RESET BI9 3 BI10 Start BI11 Trip 3 BI12 Trip J> BI13 Trip > Cab BI14 Trip Io> BI15 Trip Io>> BI16 Trip Io>>> BLOCK (BS) EXT_TRG Trip 3 GROUP START Trip RESET TRIP CB wear CU_ALARM OPEN ALARM PQ 3Inf BINOPEN TRIGG HAR_HIGH BINCLOSE RESET CUM_HIGH TCS1 TCSSTATE BS ALARM MCS 3I ALARM Ropen Master Trip Open HSPO1 (X4.2.3/4/1/2) Trip 1 >1 >1 Lockout > S HSPO1 Io>--> Q Io>>--> Lockout reset R Lockout Working Io>>>--> 1 Lockout PO1 (X4.1.12/13) > Io>--> Trip 2 Io>>--> PO2 (X4.1.14/15) Io>>>--> PO3 (X4.1.17/18) SO1 (X4.1.8/7/6) > Trip 3 Io>--> Io>>--> SO2 (X4.1.10/11/9) Io>>>--> Alarm LED1 Start External trip Trip Start > Trip Io>--> > Start Io>>--> > Trip Io>>>--> Alarm LED2 Io>-> Start Io>-> Trip RCLOSE Io>>-> Start Close Io>>-> Trip CLOSE >1 Io>>>-> Start Io>>>-> Trip > Io>--> Start 1 Start Alarm LED3 Io>>--> Trip Io>>>--> Start Trip O->I OPEN > Io>--> Start 2 O->I ACTIVE O->I ALAR1 Io>>--> O->I ALAR2 Io>>>--> Lockout DI1 Alarm LED4 DI2 DI3 BSOUT DI4 > DI5 DI6 I<->0 CB1 open DI7 I<->0 CB1 close DI8 Alarm 1 MCS 3I DI1 Alarm LED5 TCS1 DI2 PQ 3Inf har DI3 PQ 3Inf cum I<->0 CB1 open DI4 CB wear I<->0 CB1 close DI5 Alarm 2 DI6 MCS 3I DI7 TCS1 DI8 PQ 3Inf har SHOT1 PQ 3Inf cum MEAS HI ALARM Alarm LED6 SHOT2 CB wear DI2 SHOT3 DI3 SHOT4 DI4 SHOT5 O-->I Active DI5 TRDUE DI6 TDDUE DI7 ACTIVE AR1TRIP Interlocking AR2TRIP AR3TRIP MEAS LO ALARM Alarm LED7 O-->I Alarm 1 AR4TRIP MEAS HI ALARM CBFAIL DI3 DEFTRIP DI4 AR1TRIP LOCKOUT DI5 AR2TRIP SHOT_ALARM DI6 AR3TRIP DI7 AR4TRIP Lockout CBFAIL DEFTRIP LOCKOUT O-->I Alarm 2 CB wear Alarm LED8 TCS1 SHOT_ALARM MCS 3I DI4 DI5 3I2f START DI6 DI7 DI8 ConfM02_a Fig Blockschema för standardkonfiguration M01 i 29

30 Skyddsrelä 1MRS HW-version: High/Sensors Standardkonfiguration H01 (Sensorer) Egenskaper Trefasigt riktat överströmsskydd med två steg Trefasigt oriktat överströmsskydd med ett steg Trefasig detektering av inkopplingsströmstöt för transformator eller startström för motor Riktat jordfelsskydd med tre steg Trefasigt fasavbrottsskydd Trefasigt termiskt skydd för kablar Synkroniseringskontroll/spänningskontroll, ett steg Övervakning av strömmätkretsar Övervakning av spänningsmätkretsar Mätning av distorsionen i strömmens vågform Mätning av distorsionen i spänningens vågform Trefasig strömmätning Mätning av nollpunktsström Trefasig spänningsmätning (fas till jord) Mätning av nollpunktspänning Mätning av systemfrekvens Trefasig effekt- och energimätning Beräkning av ackumulerat brytarslitage Störningsskrivare Övervakning av utlösningskrets Fördröjd utlösningsutgång för brytarfelsskyddet Automatisk återinkoppling 1 5 steg Brytarkontroll med indikering Spärrningsfunktion (Lockout) Objektindikering Logikstyrd manöverlägesväljare Ingångar och utgångar (I/O) som kan konfigureras av användaren Förregling Larmlysdioder som kan konfigureras av användaren! Standardkonfigurationen H01 finns endast med HW-versionen sensor. 30

31 1MRS Skyddsrelä 67 MCS I > 0 67N 3I > 2f 68 I > 46 TCS1 CBCM 0 I 3I~harm R 3U~harm 3 49F 3I I 0 P SYNC 25 0 I 79 3U U 0 Q */62 f pf E LO 86 H01 Fig Blockschema för standardkonfiguration H01 H Applikation Standardkonfigurationen H01 för är planerad för användning i system med en enkel samlingsskena och en brytare för selektivt riktat och oriktat kortslutnings-, riktat tidöverströms- och riktat jordfelsskydd för automatisk återinkoppling med synkroniserings- och spänningskontroll. Närmare information om konfigurationen, se applikationsexemplen med standardkonfiguration H01 på sidan

32 Skyddsrelä 1MRS DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 Reset 1 Reset 2 Group Blocking 1 X4.2.5/6 X4.2.6/7 X4.2.8/9 X4.2.9/10 X4.2.11/12 X4.2.13/14 X4.2.15/16 X4.2.17/18 X3.1.1/2 Blocking 2 DREC trig PQ 3Inf trig O-->I INH O-->I ON O-->I Ext. start O-->I Ext. trip Master trip External trip Lockout reset Remote Close enable Open Close SWGRP O/C E/F PQ 3Inf O-->I PQ 3Unf O/C E/F SYNC1 O-->I AR1 AR2 AR3 AR4 *) BACTRL Io>--> Io>>--> Io>>>--> Master trip External trip Lockout reset CBO DC1 DC2 O/C E/F PQ 3Inf O-->I PQ 3Unf BS1 --> BS1 --> BS1 > BS1 Io>--> BS1 Io>>--> BS1 Io>>>--> BS1 CBO DC1 DC2 BS2 --> BS2 --> BS2 > BS2 Io>--> BS2 Io>>--> BS2 Io>>>--> BS2 BS SWGRP TCS BS I<->O IND1 I<->O CB1 Io> I<->O CB1 OPEN OOPEN OPENENA OCLOSE CLOSE AOPEN BACTRL CLOSEENA ACLOSE BS1 START BINOPEN BS2 TRIP BINCLOSE GROUP RESET I<->O IND1 BINOPEN Io>> BINCLOSE I<->O IND2 BINOPEN BACTRLB START BINCLOSE S1 TRIP I<->O POS BS2 BINLOCAL GROUP BINREMOTE RESET Io>>> BACTRL BS1 BS2 GROUP RESET BACTRL START BS1 TRIP BS2 GROUP RESET START TRIP BACTRL BSOUT BS1 START BS2 TRIP GROUP DOUBLE RESET > BS1 BS2 BSOUT GROUP START DOUBLE TRIP RESET 3I2f> 3I 2f /I1f> 3dI/dt> GROUP START Io Uo s IL1 IL2 IL3 Io Uo 3I DREC IL1 IL2 IL3 Io Iob U1 U2 U3 BI1 Start --> BI2 Start --> BI3 Start > BI4 Start Io>--> BI5 Start Io>>--> BI6 Start Io>>>--> BI7 Start BI8 Start BI9 Trip --> BI10 Trip --> BI11 Trip > BI12 Trip Io>--> BI13 Trip Io>>--> BI14 Trip Io>>>--> BI15 Trip BI16 Trip EXT_TRG 3U UL1_U12 UL2_U23 UL3_U31 ES1 ES1 I<->O IND2 3DI> Logic input 1 Logic input 2 Logic input 3 3I2f START 3I2f START 3I2f START ES2 Lockout Working DOUBLE --> DOUBLE > ES2 Interlocking_A Interlocking_B Interlocking_C Interlocking_D Interlocking_E & CLOSEENA I<->O CB1 BS1 BS2 START GROUP TRIP RESET BLOCK GROUP RESET 3 J> Cab START TRIP CU_ALARM PQE CB wear OPEN ALARM BINOPEN BIN- CLOSE TCS1 TCSSTATE BS ALARM ALARM MCS 3I O-->I AR1 OPEN MCS 3U AR2 CLOSE ALARM BS1 --> AR3 DEFTRIP BS1 --> AR4 PQ 3Inf LOCKOUT BS1 > ARINH TRIGG HAR_HIGH BS1 Io>--> CBOPEN RESET CUM_HIGH BS1 Io>>--> CBCLOSE ON PQ 3Unf BS1 Io>>>--> RESET BS1 TRIGG HAR_HIGH RESET CUM_HIGH BS2 --> BS2 --> BS2 > BS2 Io>--> BS2 Io>>--> BS2 Io>>>--> BS2 BS SYNC Command SC_OK Ropen RCLOSE CLOSE --> --> > Io>--> Io>>--> Io>>>--> --> --> > Io>--> Io>>--> Io>>>--> --> --> > Io>--> Io>>--> Io>>>--> I<->0 CB1 open I<->0 CB1 close MCS 3I TCS1 PQ 3Inf har PQ 3Inf cum CB wear MCS 3U PQ 3Unf har PQ 3Unf cum SHOT1 SHOT2 SHOT3 SHOT4 SHOT5 TRDUE TDDUE ACTIVE >1 AR1TRIP AR2TRIP AR3TRIP AR4TRIP CBFAIL DEFTRIP LOCKOUT SHOT_ALARM --> --> > Io>--> Io>>--> Io>>>--> --> --> > Io>--> Io>>--> Io>>>--> External trip --> --> > Io>--> Io>>--> Io>>>--> --> > Lockout I<->0 CB1 open I<->0 CB1 close MCS 3I TCS1 PQ 3Inf har PQ 3Inf cum CB wear MCS 3U PQ 3Unf har PQ 3Unf cum AR1TRIP AR2TRIP AR3TRIP AR4TRIP CBFAIL DEFTRIP LOCKOUT SHOT_ALARM Master Trip Open Trip 1 >1 3I2f START Trip 2 Trip 3 Close Start 1 Start 2 BSOUT Alarm 1 Alarm 2 O-->I Active O-->I Alarm 1 O-->I Alarm 2 Lockout reset S PO1 PO2 PO3 SO1 SO2 Q Lockout HSPO1 R Lockout Working (X4.1.12/13) (X4.1.14/15) (X4.1.17/18) (X4.1.8/7/6) (X4.1.10/11/9) -> Start -> Trip -> Start -> Trip > Start > Trip Io>-> Start Io>-> Trip Io>>-> Start Io>>-> Trip Io>>>-> Start Io>>>-> Trip Start Trip Start Trip O->I OPEN O->I ACTIVE O->I ALAR1 O->I ALAR2 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 MEAS HI ALARM DI2 DI3 DI4 DI5 DI6 DI7 Interlocking MEAS LO ALARM MEAS HI ALARM DI3 DI4 DI5 DI6 DI7 Lockout CB wear TCS1 MCS 3I MCS 3U DI5 DI6 DI7 DI8 >1 1 Lockout HSPO1 (X4.2.3/4/1/2) Alarm LED1 Alarm LED2 Alarm LED3 Alarm LED4 Alarm LED5 Alarm LED6 Alarm LED7 Alarm LED8 f ConfH01_a Fig Blockschema för standardkonfiguration H01 för 32

33 1MRS Skyddsrelä Standardkonfiguration H Egenskaper Trefasigt riktat överströmsskydd med två steg Trefasigt oriktat överströmsskydd med två steg Trefasig detektering av inkopplingsströmstöt för transformator eller startström för motor Riktat jordfelsskydd med tre steg Underfrekvens- eller överfrekvensskydd med ett steg Trefasigt fasavbrottsskydd Trefasigt termiskt skydd för kablar Övervakning av strömmätkretsar Övervakning av spänningsmätkretsar Mätning av distorsionen i strömmens vågform Mätning av distorsionen i spänningens vågform Trefasig strömmätning Mätning av nollpunktsström Trefasig spänningsmätning Mätning av nollpunktspänning Mätning av systemfrekvens Trefasig effekt- och energimätning Beräkning av ackumulerat brytarslitage Störningsskrivare Övervakning av utlösningskrets Fördröjd utlösningsutgång för brytarfelsskyddet Automatisk återinkoppling 1 5 steg Brytarkontroll med indikering Spärrningsfunktion (Lockout) Objektindikering Logikstyrd manöverlägesväljare Ingångar och utgångar (I/O) som kan konfigureras av användaren Förregling Larmlysdioder som kan konfigureras av användaren 33

34 Skyddsrelä 1MRS I > 50/51 I 0 > 67N f</f> 81U/81O 3I 2f > 68 I> 46 MCS1 TCS CBCM 3I~harm 3U~harm I R 3 49F 3I I 0 P 0 I 79 */62 3U U 0 Q LO 86 H02 f pf E H Applikation Fig Blockschema för standardkonfiguration H02 Standardkonfigurationen H02 för är planerad för användning i system med en enkel samlingsskena och en brytare för selektivt riktat och oriktat kortslutnings-, riktat och oriktat tidöverströms- och riktat jordfelsskydd samt automatisk återinkoppling med synkroniserings- och spänningskontroll. Närmare information om konfigurationen, se applikationsexemplen med standardkonfiguration H02 på sidan

35 1MRS Skyddsrelä Io> I<->O CB1 OPEN OOPEN OPENENA OCLOSE CLOSE AOPEN BACTRL CLOSEENA ACLOSE BS1 START BINOPEN BS2 TRIP BINCLOSE GROUP RESET I<->O IND1 BINOPEN Io>> BINCLOSE I<->O IND2 BINOPEN BACTRL START BINCLOSE BS1 TRIP I<->O POS BS2 GROUP BINLOCAL RESET BINREMOTE Io Io>>> Io BS1 BS2 START GROUP TRIP RESET BS1 BS2 BSOUT GROUP START DOUBLE TRIP RESET BACTRL START BS1 TRIP BS2 GROUP RESET SWGRP O/C E/F PQ 3Inf O-->I PQ 3Unf f1 Reset 1 Uo Uo BACTRL START BS1 TRIP 3I BS2 IL1 GROUP IL2 RESET IL3 O/C E/F PQ 3Inf O-->I PQ 3Unf f1 IL1 DREC IL2 IL3 Io Iob Uo U12 U23 U31 BI1 Start --> BI2 Start --> BI3 Start BI4 Start BI5 Start Io>--> BI6 Start Io>>--> BI7 Start Io>>>--> BI8 Start BI9 Start BI10 Start1 f1 BI11 Start2 f1 BI12 Trip 1 BI13 Trip 2 BI14 Trip 3 BI15 BI16 EXT_TRG BACTRL BSOUT BS1 START BS2 TRIP GROUP DOUBLE RESET 3I2f> 3I 2f /I1f> 3dI/dt> GROUP START 3U UL1_U12 UL2_U23 UL3_U31 PQE CB wear 3DI> OPEN ALARM BINOPEN BS1 BINCLOSE BS2 START GROUP TRIP TCS1 RESET TCSSTATE BS ALARM 3 MCS 3I J> ALARM Cab MCS 3U BLOCK START ALARM GROUP TRIP RESET PQ 3Inf CU_ALARM TRIGG HAR_HIGH RESET CUM_HIGH f1 f< PQ 3Unf f> TRIGG HAR_HIGH RESET CUM_HIGH df/dt< df/dt> O-->I AR1 OPEN AR2 CLOSE BS1 START1 AR3 DEFTRIP BS2 TRIP1 AR4 LOCKOUT GROUP START2 ARINH RESET TRIP2 CBOPEN CBCLOSE ON RESET Ropen --> --> Io>--> Io>>--> Io>>>--> f1 Trip1 f1 Trip2 --> --> Io>--> Io>>--> Io>>>--> RCLOSE CLOSE >1 --> --> Io>--> Io>>--> Io>>>--> f1 Start1 f1 Start2 I<->0 CB1 open I<->0 CB1 close MCS 3I TCS1 PQ 3Inf har PQ 3Inf cum CB wear MCS 3U PQ 3Unf har PQ 3Unf cum SHOT1 SHOT2 SHOT3 SHOT4 SHOT5 TRDUE TDDUE ACTIVE AR1TRIP AR2TRIP AR3TRIP AR4TRIP CBFAIL DEFTRIP LOCKOUT SHOT_ALARM --> --> Io>--> Io>>--> Io>>>--> f1 Trip1 f1 Trip2 --> --> Io>--> Io>>--> Io>>>--> f1 Trip1 f1 Trip2 Reset 2 O/C E/F Group BS2 --> BS2 --> BS2 BS2 BS2 Io>--> BS2 Io>>--> BS2 Io>>>--> BS2 BS BS2 f1 BS1 --> BS1 --> BS1 BS1 BS1 Io>--> BS1 Io>>--> BS1 Io>>>--> BS1 BS1 f1 f1 External trip --> --> Io>--> Io>>--> Io>>>--> f1 Start1 f1 Start2 Blocking 1 --> Lockout I<->0 CB1 open I<->0 CB1 close MCS 3I TCS1 PQ 3Inf har PQ 3Inf cum CB wear MCS 3U PQ 3Unf har PQ 3Unf cum AR1TRIP AR2TRIP AR3TRIP AR4TRIP CBFAIL DEFTRIP LOCKOUT SHOT_ALARM Master Trip Open 3I2f START Trip 1 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 DI9 Trip 2 Trip 3 Close Start 1 Start 2 BSOUT X4.2.5/6 X4.2.6/7 X4.2.8/9 X4.2.9/10 X4.2.11/12 X4.2.13/14 X4.2.15/16 X4.2.17/18 X3.1.1/2 Blocking 2 DREC trig PQ 3Inf trig PQ 3Unf trig O-->I INH O-->I ON O-->I AR1 AR2 AR3 AR4 *) O-->I Ext. start O-->I Ext. trip Io>-> Io>>-> Io>>>-> Master trip External trip Lockout reset Alarm 1 Alarm 2 O-->I Active O-->I Alarm 1 O-->I Alarm 2 >1 Lockout reset S Q R Lockout Working PO1 PO2 PO3 SO1 SO2 Start Trip Start Trip -> Start -> Trip -> Start -> Trip Lockout HSPO1 (X4.1.12/13) (X4.1.14/15) (X4.1.17/18) (X4.1.8/7/6) (X4.1.10/11/9) Io>-> Start Io>-> Trip Io>>-> Start Io>>-> Trip Io>>>-> Start Io>>>-> Trip BACTRL Master trip External trip Lockout reset Remote Close enable f1 Start 1 f1 Trip 1 f1 Start 2 f1 Trip 2 Start Trip Start Trip I<->O CB1 SWGRP CBO CBO TCS BS Open Close O->I OPEN O->I ACTIVE O->I ALAR1 O->I ALAR2 DI1 DI2 DI3 DI4 DC1 I<->O IND1 DC2 DC1 DC2 ES1 ES1 I<->O IND2 ES2 ES2 CLOSEENA I<->O CB1 & Interlocking_A Interlocking_B Interlocking_C Interlocking_D Interlocking_E Logic input 1 Logic input 2 Logic input 3 Lockout Working DOUBLE --> DOUBLE 3I2f START BS2 --> BS2 --> BS2 BS2 BS2 Io>--> BS2 Io>>--> BS2 Io>>>--> BS2 BS BS2 f1 3I2f START BS1 --> BS1 --> BS1 BS1 BS1 Io>--> BS1 Io>>--> BS1 Io>>>--> BS1 BS1 f1 3I2f START DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 MEAS HI ALARM DI2 DI3 DI4 DI5 DI6 DI7 Interlocking MEAS LO ALARM MEAS HI ALARM DI3 DI4 DI5 DI6 DI7 Lockout CB wear TCS1 MCS 3I MCS 3U DI5 DI6 DI7 DI8 >1 1 Lockout Alarm LED1 Alarm LED2 Alarm LED3 Alarm LED4 Alarm LED5 Alarm LED6 Alarm LED7 Alarm LED8 HSPO1 (X4.2.3/4/1/2) f ConfH02_a Fig Blockschema för standardkonfiguration H02 i 35

36 Skyddsrelä 1MRS Standardkonfiguration H Egenskaper Trefasigt oriktat överströmsskydd med tre steg Trefasig detektering av inkopplingsströmstöt för transformator eller startström för motor Riktat jordfelsskydd med tre steg Trefasigt fasavbrottsskydd Trefasigt termiskt skydd för kablar Synkroniseringskontroll/spänningskontroll, ett steg Övervakning av strömmätkretsar Övervakning av spänningsmätkretsar Mätning av distorsionen i strömmens vågform Mätning av distorsionen i spänningens vågform Trefasig strömmätning Mätning av nollpunktsström Trefasig spänningsmätning 1 Mätning av nollpunktsspänning Mätning av systemfrekvens Trefasig effekt- och energimätning Beräkning av ackumulerat brytarslitage Störningsskrivare Övervakning av utlösningskrets Fördröjd utlösningsutgång för brytarfelsskyddet Automatisk återinkoppling 1 5 steg Brytarkontroll med indikering Spärrningsfunktion (Lockout) Objektindikering Logikstyrd manöverlägesväljare Ingångar och utgångar (I/O) som kan konfigureras av användaren Förregling Larmlysdioder som kan konfigureras av användaren 1. Endast i sensorversionen. 36

37 1MRS Skyddsrelä Fig Blockschema för standardkonfiguration H03 H Applikation Standardkonfigurationen H03 för är planerad för användning i system med en enkel samlingsskena och en brytare för selektivt oriktat kortslutnings-, oriktat tidöverströms- och riktat jordfelsskydd samt automatisk återinkoppling med synkroniserings- och spänningskontroll. Närmare information om konfigurationen, se applikationsexemplen med standardkonfiguration H03 på sidan sidan

REX 521 Skyddsrelä. Teknisk referensmanual, standardkonfigurationer

REX 521 Skyddsrelä. Teknisk referensmanual, standardkonfigurationer Skyddsrelä 1MRS755327 Utgiven: 20.07.2004 Version: B/31.05.2007 Övers. av version: K/29.09.2006 Skyddsrelä Innehåll 1. Om denna manual...15 1.1. Denna manual...15 1.2. Symboler...15 1.3. Dokument i anslutning

Läs mer

Ledningsskyddsrelä REX 521. Produktguide

Ledningsskyddsrelä REX 521. Produktguide Ledningsskyddsrelä REX 5 Produktguide Utgiven:.08.007 Status: Översättning av version F/5.0.006 Version: A/.08.007 Rätt till ändringar förbehålles. Allmänt Skyddsreläet REX 5 lämpar sig för skydd, styrning,

Läs mer

REM 54_ Maskinterminal. Teknisk referensmanual, allmän

REM 54_ Maskinterminal. Teknisk referensmanual, allmän REM _ Maskinterminal MRS-MUM Maskinterminal Utgiven:.0. Version: B/..00 Översättn. av version:e/.0.00 REM _ Innehåll. Allmänt om denna manual..... Copyright..... Varumärken..... Om denna manual..... Ordförteckning.....

Läs mer

REF 54_ Ledningsterminal

REF 54_ Ledningsterminal REF _ ABB Automation MRS 00-MUM Utgiven:.0. Version: C/.0.000 Granskad: ML Godkänd: E.P. REF _ Rätt till tekniska ändringar förbehålles. Innehåll. Inledning..... Allmänt..... Hårdvaruversioner.... Säkerhetsinformation....

Läs mer

Transformatorterminal RET 54_. Teknisk referensmanual, allmän

Transformatorterminal RET 54_. Teknisk referensmanual, allmän Transformatorterminal RET _, allmän MRS Utgiven: 0.0.00 Version: C/.0.00 Transformatorterminal RET _ Innehåll. Om denna manual..... Copyright..... Varumärken..... Allmänt..... Förkortningar..... Manualer

Läs mer

REF 54_ Ledningsterminal. Teknisk referensmanual, Allmän

REF 54_ Ledningsterminal. Teknisk referensmanual, Allmän REF _ MRS 00-MUM Utgiven:.0.00 Version: D Granskad: Godkänd: REF _ Rätt till tekniska ändringar förbehålles. Innehåll. Inledning..... Allmänt..... Hårdvaruversioner.... Säkerhetsinformation.... Instruktioner.....

Läs mer

Relion 615 serie. Kondensatorbankskydd och styrning REV615

Relion 615 serie. Kondensatorbankskydd och styrning REV615 Relion 65 serie Kondensatorbankskydd och styrning REV65 Kompakt och mångsidig lösning för kraftdistributionssystem för energiföretag och industrier REV65 är en dedikerad IED (intelligent electronic device)

Läs mer

REF 54_ Ledningsterminal Teknisk referensmanual

REF 54_ Ledningsterminal Teknisk referensmanual REF _ Industrial IT enabled products from ABB are the building blocks for greater productivity, featuring all the tools necessary for lifecycle product support in consistent electronic form. MRS 00-MUM

Läs mer

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB D

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB D Dokumentslag Verksamhetsstyrande 1 (8) Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB D15-0019591 1.0 Organisation Giltig fr o m Giltig t o m Anläggning 2016-02-22 Dokumentansvarig

Läs mer

SPAA 341 C. Ledningsskyddsrelä. Bruksanvisning och teknisk beskrivning SPAA 341 C. U aux V ~ V. f n. t 2 > [ s ] 0 I 0 >> Trip

SPAA 341 C. Ledningsskyddsrelä. Bruksanvisning och teknisk beskrivning SPAA 341 C. U aux V ~ V. f n. t 2 > [ s ] 0 I 0 >> Trip SPAA C Ledningsskyddsrelä Bruksanvisning och teknisk beskrivning f n = 0Hz 0Hz I n = A A ( I ) I n = A A ( I 0B ) I n = 0,A A ( I 0 ) U n = 00V 0V 0V ( ) U 0 I > I I L I L I L I o IRF Uo I o ϕ U o I IRF

Läs mer

Skyddsrelä REX 521. Användarmanual

Skyddsrelä REX 521. Användarmanual Skyddsrelä REX 521 1MRS752218-MUM Utgiven: 15.01.2001 Version: D/21.03.2007 Övers. av version:f/17.02.2006 Skyddsrelä REX 521 Innehållsförteckning 1. Om denna manual...7 1.1. Denna manual...7 1.2. Symboler...7

Läs mer

TEKNISK RIKTLINJE 2012-06-08 TR02-05-7

TEKNISK RIKTLINJE 2012-06-08 TR02-05-7 Utgåva Ändringsnot Datum 1 Första utgåva. Ersätter TR2-05-7-1 TR2-05-7-7 2012-06-08 2/16 Innehåll 1 Allmänt... 5 1.1 Reläskydd... 5 1.1.1 Reläskydd för transformatorer i ställverk med enkelskena eller

Läs mer

4-stegs jordströmsskydd

4-stegs jordströmsskydd SVENSKA z. KRAFTNÄT ENHET, VERKSAMHETSOMRÅDE NK, Kontrollanläggning VAR BETECKNING TR02-05-2-3 DATUM 2013-12-10 SAMRAD AS.AN..DK TEKNISK RIKTLINJE UTGÅVA 4 FASTSTÄLLD TI 4-stegs jordströmsskydd 1/7 Uppdateringar

Läs mer

Skyddsrelä REX 521. Teknisk referensmanual, allmän

Skyddsrelä REX 521. Teknisk referensmanual, allmän Skyddsrelä REX 5, allmän MRS757-MUM Utgiven: 5.0.00 Version: E/8.0.00 Övers. av version: K/8.0.00 Skyddsrelä REX 5 Innehållsförteckning. Om denna manual...9.. Denna manual...9.. Symboler...9.3. Dokument

Läs mer

SPAA 345 C. Ledningsskyddsrelä. Bruksanvisning och teknisk beskrivning SPAA 345 C V ~ V. f n = 50Hz 60Hz. Uo I o.

SPAA 345 C. Ledningsskyddsrelä. Bruksanvisning och teknisk beskrivning SPAA 345 C V ~ V. f n = 50Hz 60Hz. Uo I o. SPAA C Ledningsskyddsrelä Bruksanvisning och teknisk beskrivning f n = 0Hz 0Hz I n = A A ( I ) I n = A A ( I 0B ) I n = 0,A A ( I 0 ) U n = 00V 0V ( U 0 ) I > I I L I L I L I o IRF Uo I o I ϕ U tr IRF

Läs mer

SVENSKA _ KRAFTNÄT AS,AN,D^,, TEKNISK RIKTLINJE. ffzéi>,?%>> ÄA, istansskydd. TEKNISK RIKTLINJE TR utg 5 1/8

SVENSKA _ KRAFTNÄT AS,AN,D^,, TEKNISK RIKTLINJE. ffzéi>,?%>> ÄA, istansskydd. TEKNISK RIKTLINJE TR utg 5 1/8 SVENSKA _ KRAFTNÄT ENHET, VERKSAMHETSOMRÅDE NK, Kontrollanläggning VAR BETECKNING TR02-05-2-2 DATUM SAMRAD 2013-12-10 AS,AN,D^,, TEKNISK RIKTLINJE ffzéi>,?%>> UTGÅVA FASTSTÄLLD ÄA, istansskydd 1/8 Uppdateringar

Läs mer

Shuntkondensatorskydd

Shuntkondensatorskydd SVENSKA KRAFTNÄT ENHET, VERKSA MHETSOMRÅDE AS, Skyddssystem och nätdata VAR BETECKN ING TR02-05-6 DATUM 2017-03-23 UTGAVA 1 SAMRÄD AF, AU, NK /VA f- TEKNISK RIKTLINJE FASTSTÄLLD TD Shuntkondensatorskydd

Läs mer

REM 610 Motorskyddsrelä. Teknisk referensmanual

REM 610 Motorskyddsrelä. Teknisk referensmanual REM 610 Motorskyddsrelä 1MRS755 442 Utgiven: 26.10.2004 Version: A/26.10.2004 Översättning av version: A/18.08.2003 Motorskyddsrelä REM 610 Innehåll 1. Allmänt om denna manual...6 1.1. Copyright...6 1.2.

Läs mer

Anläggningsdirektiv Regionnät gäller som grund för detta dokument. Avvikande krav är specificerat i denna TB.

Anläggningsdirektiv Regionnät gäller som grund för detta dokument. Avvikande krav är specificerat i denna TB. Dokumentslag Verksamhetsstyrande 1 (6) Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB D16-0013808 1.0 Organisation Giltig fr o m Giltig t o m Anläggning 2016-09-26 Dokumentansvarig

Läs mer

SPAC 531 C Ledningsterminal

SPAC 531 C Ledningsterminal SPAC 531 C Ledningsterminal Bruksanvisning och teknisk beskrivning I n = 1 / 5 A( I ) I n = 1 / 5 A( I o ) U n = 100 / 110 V( U ) U n = 100 / 110 V( U o ) f n = 50Hz 60Hz 2 5 B I L1 I L2 I L3 B I > I >>

Läs mer

SAMLINGSSKENESKYDD. TEKNISK RIKTLINJE TR utg D 1/14. NK, Kontrollanläggning DATUM TEKNISK RIKTLINJE UTGÅVA D

SAMLINGSSKENESKYDD. TEKNISK RIKTLINJE TR utg D 1/14. NK, Kontrollanläggning DATUM TEKNISK RIKTLINJE UTGÅVA D SvK4005, v3.3, 2012-08-09 ENHET, VERKSAMHETSOMRÅDE NK, Kontrollanläggning VÅR BETECKNING TR02-05-8 DATUM 2009-11-13 TEKNISK RIKTLINJE UTGÅVA D SAMLINGSSKENESKYDD 1/14 Uppdateringar Utgåva Ändringsnot Datum

Läs mer

SMS-larm L Version Gjutarevägen Stenkullen

SMS-larm L Version Gjutarevägen Stenkullen SMS-larm L-53 2018-01-26 Version 3.00 www.intab.se info@intab.se 0302-24 600 Gjutarevägen 1 443 61 Stenkullen 1. Beskrivning Intabs SMS-larm är enkelt att använda för att få händelselarm via SMS. Alarmet

Läs mer

SMS-larm L-53. 2014-09-12 Ver. 2.91. www.intab.se info@intab.se 0302-24 600 Gjutarevägen 1 443 61 Stenkullen

SMS-larm L-53. 2014-09-12 Ver. 2.91. www.intab.se info@intab.se 0302-24 600 Gjutarevägen 1 443 61 Stenkullen SMS-larm L-53 2014-09-12 Ver. 2.91 www.intab.se info@intab.se 0302-24 600 Gjutarevägen 1 443 61 Stenkullen 1. Beskrivning Intabs SMS-larm är enkelt att använda för att få händelselarm via SMS. Alarmet

Läs mer

Softstart funktion Hög verkningsgrad Låg störningsnivå Jämn, reglerad och filtrerad utspänning av hög kvalitet Effektiv kylning LED indikatorer

Softstart funktion Hög verkningsgrad Låg störningsnivå Jämn, reglerad och filtrerad utspänning av hög kvalitet Effektiv kylning LED indikatorer Inverter från 24V DC till 220/230V AC Softstart funktion Hög verkningsgrad Låg störningsnivå Jämn, reglerad och filtrerad utspänning av hög kvalitet Effektiv kylning LED indikatorer Spänningsomvandlare

Läs mer

SPAA 348 C. Ledningsskyddsrelä. Bruksanvisning och teknisk beskrivning SPAA 348 C V ~ V. t 2 > [ s ] t d.

SPAA 348 C. Ledningsskyddsrelä. Bruksanvisning och teknisk beskrivning SPAA 348 C V ~ V. t 2 > [ s ] t d. SPAA 48 C Ledningsskyddsrelä Bruksanvisning och teknisk beskrivning f n = 50Hz 60Hz I n = A 5A ( I ) I n = 0,A A ( I 0 ) U n 00V...0V ( U ) U n = 00V/0V/0V ( U 0 ) 5 I > I L U I L U IRF Uo I o ϕ U o I

Läs mer

SPAA 120 C och SPAA 121 C Ledningsskydd

SPAA 120 C och SPAA 121 C Ledningsskydd SPAA 10 C och SPAA 11 C Ledningsskydd Bruksanvisning och teknisk beskrivning f n = 50Hz 60Hz I n = 1A 5A ( I ) I n = 1A 5A ( I o ) U n = 100V 110V ( U o ) 5 B I > I I L1 I L3 Uo I o IRF SPAA 10 C 1 3 4

Läs mer

VAMP 120. Ljusbågsskydd. Användarmanual

VAMP 120. Ljusbågsskydd. Användarmanual VAMP 120 VAMP 120 2 VAMP 24t support tfn : +358 (0)20 753 3264 VM120.SE001 VAMP 120 Innehållsförteckning 1. Allmänt... 4 1.1. et VAMP 120... 4 1.2. Egenskaper... 4 2. Konfigurering... 5 3. Sensorer...

Läs mer

IndraDrive Open-loop. Styrning av asynkronmotor över Profibus. Version 1

IndraDrive Open-loop. Styrning av asynkronmotor över Profibus. Version 1 IndraDrive Open-loop Styrning av asynkronmotor över Profibus Version 1 1. Inställningar för master kommunikation Öppna inställningarna för master kommunikationen genom att expandera mappen Master communication

Läs mer

Längsdifferentialskydd

Längsdifferentialskydd SVENSKA KRAFTNÄT ENHET, VERKSAMHETSOMRÅDE AS rf VÅR BETECKNING TR02-05-02-04 DATUM 2017-11-29 SAMRÅD AF, AU, NK TEKNISK RIKTLINJE UTGÅVA 6 FASTSTÄLLD TD Längsdifferentialskydd SVK4005, v4.0, 2016-04-27

Läs mer

Produkter som höjer tillgängligheten i ditt nät

Produkter som höjer tillgängligheten i ditt nät Produkter som höjer tillgängligheten i ditt nät P R O D U K T K A T A L O G 2015 Feldetektorer och reläskydd Protrols produkter är utvecklade för kostnadseffektiv och tillförlitlig driftövervakning och

Läs mer

REJ 525 Kombinerat överströms- och jordfelsrelä Teknisk referensmanual

REJ 525 Kombinerat överströms- och jordfelsrelä Teknisk referensmanual Kombinerat överströms- och jordfelsrelä Industrial IT enabled products from ABB are the building blocks for greater productivity, featuring all the tools necessary for lifecycle product support in consistent

Läs mer

SPCJ 4D24 Kombinerad överströmsoch jordströmsrelämodul. Bruksanvisning och teknisk beskrivning

SPCJ 4D24 Kombinerad överströmsoch jordströmsrelämodul. Bruksanvisning och teknisk beskrivning SPCJ 4D4 Kombinerad överströmsoch jordströmsrelämodul Bruksanvisning och teknisk beskrivning 1MRS 750303-MUM SV Utgiven 1996-03-15 Uppdaterad 008-04-11 Upplaga C (ersätter 34 SPAJ 9 SV1) Granskad MK Godkänd

Läs mer

B 3I >> I >> / I IRF. o I STEP 6.0 RESET STEP. I n SG1. [ s] RESET PROGRAM SGF. 0.6 t >> [ s] SGR 1 SGR 2 TRIP.

B 3I >> I >> / I IRF. o I STEP 6.0 RESET STEP. I n SG1. [ s] RESET PROGRAM SGF. 0.6 t >> [ s] SGR 1 SGR 2 TRIP. L 2 s s t θ 6x t o o t si n n s n L θ o SPAC 537 C Ledningsterminal Bruksanvisning och teknisk beskrivning I n = 1 / 5 A( I ) I n = 1 / 5 A( I o ) U n = 100 / 110 V( U ) U n = 100 / 110 V( U o ) f n =

Läs mer

Utlösningskretsar och brytarvalsutrustning. och automatiker

Utlösningskretsar och brytarvalsutrustning. och automatiker * " SVENSKA KRAFTNÄT ENHET, VERKSAMHETSOMRÅDE NK, Kontrollanläggning @b> VÄR BETECKNING TR02-05-9 DATUM 2015-03-06 SAMRAD AS, AFS /n? M/ TEKNISK RIKTLINJE UTGAVA 4 FASTSTÄLLD TD Utlösningskretsar och brytarvalsutrustning

Läs mer

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT 091123-025 D10-0016465 1.0

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT 091123-025 D10-0016465 1.0 Dokumentslag Verksamhetsstyrande 1 (13) Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT 091123-025 D10-0016465 1.0 Organisation Giltig fr o m Giltig t o m Anläggning 2014-03-24

Läs mer

t >> [ s] I o>> U o> IRF IRF o I STEP STEP I ϕ >> RESET STEP STEP I n SG1 SG PROGRAM RESET RESET

t >> [ s] I o>> U o> IRF IRF o I STEP STEP I ϕ >> RESET STEP STEP I n SG1 SG PROGRAM RESET RESET (5min) o SPAC 539 C Ledningsterminal Bruksanvisning och teknisk beskrivning I n = / 5 A( I ) I n = 0,2 / A( I o) I n = / 5 A( I o2 ) U n = 00 / 0 V( U ) U n = 00 / 0 V( U o ) f n = 50Hz 60Hz 2 5 I L I

Läs mer

ATICS- -DIO checklista

ATICS- -DIO checklista Mjukvaru version: D333 V1.2x, D334 V1.2x, D335 V1.0x Inställning och provning vid driftsättning Denna lista innehåller fabriksinställningar och systemspecifika inställningarna för ATICS-2-DIO resp. ATICS-4-DIO

Läs mer

Fördelningsteknik, LSP. Arrangeras av Voltimum.se portalen för elproffs

Fördelningsteknik, LSP. Arrangeras av Voltimum.se portalen för elproffs Fördelningsteknik, LSP Kent Andersson Leif Lundberg Dimensionera din elanläggning rätt Vi koncentrerar oss på 2 saker - Skydd för person och egendom - Välja rätt apparat 1. Skydd för person och egendom

Läs mer

Bruksanvisning AS-i-säkerhetsmodul för nödstopp Manöverenhet AC012S 7390732 / 00 05 / 2008

Bruksanvisning AS-i-säkerhetsmodul för nödstopp Manöverenhet AC012S 7390732 / 00 05 / 2008 Bruksanvisning AS-i-säkerhetsmodul för nödstopp Manöverenhet SV AC012S 7390732 / 00 05 / 2008 Innehåll Säkerhetsanvisningar...3 Installation/idrifttagning...4 Manövrerings- och indikeringselement...6 Montering...6

Läs mer

Skyddsrelä REX 521. Teknisk referensmanual, allmän

Skyddsrelä REX 521. Teknisk referensmanual, allmän Skyddsrelä REX 5, allmän MRS757-MUM Utgiven: 5.0.00 Version: C/6..004 Övers. av version: F/0.08.004 Skyddsrelä REX 5 Innehållsförteckning. Om denna manual...6.. Copyright...6.. Varumärken...6.3. Allmänt...6.4.

Läs mer

Ljusbågsvakt REA 101. Användarmanual

Ljusbågsvakt REA 101. Användarmanual Ljusbågsvakt 1MRS751159-MUM Utgiven: 27.11.1998 Version: C/04.09.2007 Ljusbågsvakt 1. Allmänt om denna handbok...5 1.1. Copyright...5 1.2. Varumärken...5 1.3. Garanti...5 1.4. Allmänt...5 1.5. Symboler

Läs mer

KALIBRERINGS MENY. För att komma tillbaka till Mätfunktionerna håll inne M -knappen 3s. eller vänta 1 min. 1 =MOD. 9.6 KBaud

KALIBRERINGS MENY. För att komma tillbaka till Mätfunktionerna håll inne M -knappen 3s. eller vänta 1 min. 1 =MOD. 9.6 KBaud 1 (6) FUNKTION HDH-C kalibrerings/konfigureringsverktyg behövs för drifttagning av HDH-M transmittrarna. Med HDH-C kan följande utföras: - Modbus inställningar - Regulator parametrar - Mät kalibrering

Läs mer

Uppdateringar. TEKNISK RIKTLINJE TR02-08-3 utg 5 2013-05-21 2/6. Utgåva Ändringsnot Datum. 05-08-15 D Ny dokumentmall 2008-07-14 2013-05-21

Uppdateringar. TEKNISK RIKTLINJE TR02-08-3 utg 5 2013-05-21 2/6. Utgåva Ändringsnot Datum. 05-08-15 D Ny dokumentmall 2008-07-14 2013-05-21 Uppdateringar Utgåva Ändringsnot Datum 05-08-15 D Ny dokumentmall 2008-07-14 5 Omarbetad. Titel ändrad från Händelseskrivare till Händelseregistrering 2/6 Innehåll 1 Allmänt... 4 2 Funktionskrav... 4 2.1

Läs mer

SMS-larm L Version Gjutarevägen Stenkullen

SMS-larm L Version Gjutarevägen Stenkullen SMS-larm L-53 2014-09-12 Version 2.91 www.intab.se info@intab.se 0302-24 600 Gjutarevägen 1 443 61 Stenkullen Intab SMS-larm 1. Beskrivning Strömförsörjning 2 x CR123A 12 V 1500 ma DC-adapter Ingångar

Läs mer

ATICS- -ISO checklista

ATICS- -ISO checklista ATICS- -ISO checklista Mjukvaru version: D333 V1.2x, D334 V1.2x, D335 V1.0x Inställning och provning vid driftsättning Denna lista innehåller fabriksinställningar och systemspecifika inställningarna för

Läs mer

Inkopplingsanvisning

Inkopplingsanvisning Inkopplingsanvisning MGSM 5.0 MGSM 5.0-PS VARNING: Enheten får endast kopplas in av behörig person. Läs igenom instruktionerna innan inkoppling. All inkoppling måste ske med spänningen avstängd Spänningen

Läs mer

BRUKSANVISNING AQ101, AQ102, AQ110P, AQ110F V1.0

BRUKSANVISNING AQ101, AQ102, AQ110P, AQ110F V1.0 BRUKSANVISNING AQ101, AQ102, AQ110P, AQ110F V1.0 Bruksanvisning AQ101, AQ102, AQ110P, AQ110F 2 (31) Revisionshistoria Revision Datum Ändring Förkortningar HSO Halvledar utgång (High speed output) BI Binär

Läs mer

TEKNISK RIKTLINJE TR

TEKNISK RIKTLINJE TR Utgåva Ändringsnot Datum 1 Första utgåva. Ersätter TR2-05-5-1 TR2-05-5-6 2012-06-08 2/16 Innehåll 1 Allmänt... 5 1.1 Reläskydd... 5 1.1.1 Reläskydd för reaktorer i enkelbrytarställverk... 5 1.1.2 Reläskydd

Läs mer

Ledningsskyddssystem för stamnätet

Ledningsskyddssystem för stamnätet SVENSKA ^ KRAFTNÄT ENHET, VERKSAMHETSOMRÅDE NK, Koirörollanläggningar VAR BETECKNING TR02-05-2-1 DATUM SAMRAD AN,AS,AT TEKNISK RIKTLINJE zctm /rfrhf & UTGÅVA 5 TD FASTSTÄLLD Ledningsskyddssystem för stamnätet

Läs mer

SPAC 538 C och SPAC 638 C Ledningsterminal

SPAC 538 C och SPAC 638 C Ledningsterminal 8 7 6 5 4 3 0 (5min) L L3 RESET STEP PROGRAM 8 7 6 5 4 3 0 B STEP STEP SG RESET 3 4 5 6 7 8 L L L3 RESET STEP PROGRAM L B RESET STEP PROGRAM STEP STEP SG RESET STEP SG 3 4 5 6 7 8 RS 3 L L OPTION RESET

Läs mer

Bruksanvisning i original. Vital 2 och Vital 3. Användarmanual

Bruksanvisning i original. Vital 2 och Vital 3. Användarmanual Bruksanvisning i original Vital 2 och Vital 3 Användarmanual Swedish v1b 2TLC172219401_B Allmänt Vital bygger på ett enkanaligt säkerhetskoncept där ett flertal säkerhetskomponenter (t.ex. givare) kan

Läs mer

Styrskåp för system A3000 open med ECC2

Styrskåp för system A3000 open med ECC2 Databuss 1 Databuss 2 2013-11-20 Styrskåp för system A3000 open med ECC2 Centralenhet ECC2: Menypanel USB port Nätverksuttag RJ45 4 st programerbara ingångar Inställning vid leverans: 1. Start av hetvattenspolning

Läs mer

Spänningsskydd. Teknisk referensmanual

Spänningsskydd. Teknisk referensmanual REU610 1MRS755126 Utgiven: 31.01.2006 Version: A/15.03.2010 REU610 Innehåll Copyrights... 5 1. Inledning...7 1.1. Denna handbok... 7 1.2. Användning av symboler... 7 1.3. Avsedd målgrupp... 8 1.4. Produktdokumentation...

Läs mer

ANVÄNDARMANUAL SESAM 800 MOBIL BAKGAVELLYFT 942913-000 -C0

ANVÄNDARMANUAL SESAM 800 MOBIL BAKGAVELLYFT 942913-000 -C0 ANVÄNDARMANUAL SESAM 800 MOBIL BAKGAVELLYFT 942913-000 -C0 2 (16) Innehåll 1 Introduktion 3 2 Omfattning 3 3 Teknisk specifikation 4 4 Kort beskrivning av systemet 5 4.1 Mottagare 5 4.2 Sändare 5 5 Beskrivning

Läs mer

SPA-ZC22 Bussanslutningsmodul

SPA-ZC22 Bussanslutningsmodul SPA-ZC Bussanslutningsmodul Bruksanvisning och teknisk beskrivning ON ON 3 4 6 7 8 3 4 RS Ser. No POWER UAUX 0//0 V DC 0/0/30/40 V AC 4/48/60 V DC AUX INT Tx 3 4 SPA-ZC B0M 4BM 3BM B3M B4M SC RS 48 SPA

Läs mer

OMRON. PLC till PLC kommunikation (CP1L-E) Ethernet. 22 april 2014 OMRON Corporation

OMRON. PLC till PLC kommunikation (CP1L-E) Ethernet. 22 april 2014 OMRON Corporation Ethernet 22 april 2014 OMRON Corporation 2/16 Läs detta innan du bläddrar vidare OMRON Denna bok är avsedd som ett tillägg till de ursprungliga manualerna för Omrons produkter. Använd den som en hjälp

Läs mer

2 IN OCH UTGÅNGAR. 2.1 Översikt. Användarmanual ER-ipx2 ver In och Utgångar. Elektrorelä AB

2 IN OCH UTGÅNGAR. 2.1 Översikt. Användarmanual ER-ipx2 ver In och Utgångar. Elektrorelä AB Användarmanual ver. 12 2 IN OCH UTGÅNGAR I detta kapitel hittar du information om hur du kopplar in givare och ställdon till, samt hur den ska strömförsörjas. Kapitlet inleds med en översikt över tillgängliga

Läs mer

MGSM 4.0-PS+ MGSM 4.0+ Inkopplingsanvisning

MGSM 4.0-PS+ MGSM 4.0+ Inkopplingsanvisning Inkopplingsanvisning MGSM 4.0+ MGSM 4.0-PS+ VARNING: Enheten får endast kopplas in av behörig person. Läs igenom instruktionerna innan inkoppling. All inkoppling måste ske med spänningen avstängd Spänningen

Läs mer

Skydd, övervakning och styrning RE_ 5. Installationsmanual

Skydd, övervakning och styrning RE_ 5. Installationsmanual RE_ 5 1MRS750978 Utgiven: 1997.10.22 Version: G/27.05.2010 RE_ 5 Innehåll 1. Om denna manual... 5 1.1. Allmänt... 5 1.2. Användning av symboler... 5 1.3. Dokumentrevisioner... 5 2. Säkerhetsanvisningar...

Läs mer

ANVÄNDARMANUAL SESAM 800 KONFIGURERBAR 947422-000 -A0

ANVÄNDARMANUAL SESAM 800 KONFIGURERBAR 947422-000 -A0 ANVÄNDARMANUAL SESAM 800 KONFIGURERBAR 947422-000 -A0 Innehållsförteckning 1 Introduktion 3 2 Omfattning 3 3 Teknisk specifikation 4 4 Kort beskrivning av systemet 5 4.1 Mottagare 5 4.2 Sändare 5 5 Beskrivning

Läs mer

Fördröjd återinkoppling

Fördröjd återinkoppling SVENSKÅ ä. KRAFTNÄT ENHET, VERKSAMHETSOMRÅDE NK, Kontrollanläggningar var beteckning TR02-06-07 DATUM 2018-03-29 samrad AS, AU, DP TEKNISK RIKTLINJE utgava 5 FASTSTÄLLD Fördröjd återinkoppling SvK4005,

Läs mer

KOMMA IGÅNG GUIDE DALI Med WAGOs styrsystem

KOMMA IGÅNG GUIDE DALI Med WAGOs styrsystem KOMMA IGÅNG GUIDE DALI Med WAGOs styrsystem DENNA GUIDE Denna guide beskriver DALI tekniken och hur du kommer igång med en DALI styrning via WAGOs styrsystem. Först hur du gör komponent-inställningar ifrån

Läs mer

REK 510 Ströminjiceringsdon för rotorjordfelsskydd. Bruksanvisning

REK 510 Ströminjiceringsdon för rotorjordfelsskydd. Bruksanvisning REK 510 Bruksanvisning REK 510 X1 12 11 10 9 8 7 6 5 4 3 2 1 0 V 100 V 230 V 1 2 3 5 6 7 11 12 Ordering No: REK 510-AA Uaux = 100/230 Vac Un = 48 V Serial No: fn = 50/60 Hz Uexc = max 600 Vdc 1MRS 755130

Läs mer

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT D

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT D Dokumentslag Verksamhetsstyrande 1 (11) Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT-091123-031 D10-0016468 4.0 Organisation Giltig fr o m Giltig t o m Anläggning 2017-09-22

Läs mer

Installationsmanual CAT12 CE Moderkort

Installationsmanual CAT12 CE Moderkort LED2 LED S Sabotage S2 BATT J2 MICRO SD J processor CB0578 2 J5 POCSAG/GPRS J6 extra IO CB052 LED6 LED5 LED4 RS485 TERM PL8 RS485 CH-3 PL7 RS232 CH- LED3 S3 UPSI S4 RESET T3 ETHERNET PL Spänning J3-J4

Läs mer

Utbyggnadsenhet REA 105. Användarmanual

Utbyggnadsenhet REA 105. Användarmanual Utbyggnadsenhet REA 105 1MRS751157-MUM Utgiven: 02.12.1998 Version: C/15.12.2004 Övers. av version: C/01.07.2002 Utbyggnadsenhet REA 105 Innehållsförteckning 1. Allmänt om denna manual...4 1.1. Copyright...4

Läs mer

URAX-A1, -A1R. AS-i säker ingångsslav för dynamiska givare

URAX-A1, -A1R. AS-i säker ingångsslav för dynamiska givare Bruksanvisning i original URAX-A, -AR AS-i säker ingångsslav för dynamiska givare Allmän beskrivning URAX-A(R) är en säker ingångsslav för AS-i buss avsedd att anslutas till Jokabs Eden givare och Tina

Läs mer

SPAJ 110 C. Jordfelsrelä SPAJ 110 C. Bruksanvisning och teknisk beskrivning. U aux V ~ V f n. n ( I o>> SPCJ 1C8.

SPAJ 110 C. Jordfelsrelä SPAJ 110 C. Bruksanvisning och teknisk beskrivning. U aux V ~ V f n. n ( I o>> SPCJ 1C8. SPAJ 110 C Jordfelsrelä Bruksanvisning och teknisk beskrivning I n = 1A 5A ( I ) f n = 50Hz 60Hz 2 5 B I o I IRF SPAJ 110 C 80...265V ~ 18...80V U aux STEP I o > I n 0.1 0.35 0.8 STEP SPCJ 1C8 REGISTERS

Läs mer

SPAD 346 C. Stabiliserat differentialrelä. Bruksanvisning och teknisk beskrivning SPAD 346 C V ~ V. f n. I 02 I n.

SPAD 346 C. Stabiliserat differentialrelä. Bruksanvisning och teknisk beskrivning SPAD 346 C V ~ V. f n. I 02 I n. SPAD 6 C Stabiliserat differentialrelä Bruksanvisning och teknisk beskrivning f n = 50Hz 60Hz I n = A 5A ( I ) I n = A 5A ( I ) I n = A 5A ( I 0 ) I n = A 5A ( I 0 ) 5 I I d I L L L I > IRF I 0 > I 0 >

Läs mer

GPIO - General Purpose Input Output

GPIO - General Purpose Input Output GPIO - General Purpose Input Output Ur innehållet: Ideala och verkliga signaler Bitvis in- och utmatning Anslutning - fysiskt gränssnitt F407 - GPIO-modul tillämpningar Läsanvisningar: Arbetsbok avsnitt

Läs mer

Styr & Regler. Spänning, betecknas U och mäts i Volt(V) Ström, betecknas I och mäts i Ampere(A) Effekt, betecknas P och mäts i Watt(W) P U x I

Styr & Regler. Spänning, betecknas U och mäts i Volt(V) Ström, betecknas I och mäts i Ampere(A) Effekt, betecknas P och mäts i Watt(W) P U x I Spänning, betecknas U och mäts i Volt(V) Ström, betecknas I och mäts i Ampere(A) P U x I Beräkningsformel Effekt, betecknas P och mäts i Watt(W) Denna formel kallas ohms lag och går att använda när vi

Läs mer

Relion. Skydds- och automationsreferens Snabbt samlingsskeneskydd med IEC 61850 och GOOSE

Relion. Skydds- och automationsreferens Snabbt samlingsskeneskydd med IEC 61850 och GOOSE Relion Skydds- och automationsreferens Snabbt samlingsskeneskydd med IEC 61850 och GOOSE Snabbt samlingsskeneskydd med IEC 61850 och GOOSE Falu Elnät AB tar i bruk toppmodern skydds- och automationsteknik

Läs mer

SMS-larm L-52 2014-06-11. www.intab.se info@intab.se 0302-24 600 Gjutarevägen 1 443 61 Stenkullen

SMS-larm L-52 2014-06-11. www.intab.se info@intab.se 0302-24 600 Gjutarevägen 1 443 61 Stenkullen SMS-larm L-52 2014-06-11 www.intab.se info@intab.se 0302-24 600 Gjutarevägen 1 443 61 Stenkullen 1. Beskrivning Intabs SMS-larm är enkelt att använda för att få temperaturlarm via SMS. Alarmet triggas

Läs mer

SPAA 345 C Ledningsskyddsrelä

SPAA 345 C Ledningsskyddsrelä SPAA 345 C Ledningsskyddsrelä Ledningsskyddsrelä Typ SPAA 345 C Allmänna egenskaper Omfattande, numeriskt ledningsskyddsrelä som innehåller tre mångsidiga relämoduler Heltäckande relä med överströmsskydd,

Läs mer

Sepam serie 80. Tillhörande moduler för Sepam serie 80. Reläskydd

Sepam serie 80. Tillhörande moduler för Sepam serie 80. Reläskydd Teknisk information 2004 Reläskydd Sepam serie 80 Sepam serie 80 är en familj digitala enheter med hög prestanda som anänds för strömoch spänningsskyddsfunktioner. Tillhörande moduler för Sepam serie 80

Läs mer

SPAS 348 C. Ledningsskyddsrelä. Bruksanvisning och teknisk beskrivning SPAS 348 C V ~ V. f n = 50Hz 60Hz. t 2 > [ s ] 6 I 02 > Trip /

SPAS 348 C. Ledningsskyddsrelä. Bruksanvisning och teknisk beskrivning SPAS 348 C V ~ V. f n = 50Hz 60Hz. t 2 > [ s ] 6 I 02 > Trip / SPAS 8 C Ledningsskyddsrelä Bruksanvisning och teknisk beskrivning f n = 50Hz 60Hz I n = A 5A ( I ) I n = 0,A A ( I 0 ) U n 00V...0V ( U ) U n = 00V/0V/0V ( U 0 ) 5 I > I L U I L U IRF B I > I L U I L

Läs mer

Kommunikation. Startapparat Tesys U. Kom-igång med Profibus direkt till Tesys-U modul

Kommunikation. Startapparat Tesys U. Kom-igång med Profibus direkt till Tesys-U modul Kommunikation Startapparat Tesys U Kom-igång med Profibus direkt till Tesys-U modul 2008-07-03 INNEHÅLLSFÖRTECKNING 1 INLEDNING...3 1.1 ANDRA SÄTT ATT STYRA VIA PROFIBUS...3 1.1.1 I/O-systemet Advantys

Läs mer

Iso DIN Användarmanual 1 kanals jordfelsövervakning

Iso DIN Användarmanual 1 kanals jordfelsövervakning Sida 1 av 5 2017 03 02 Användarmanual Iso DIN Iso DIN Användarmanual 1 kanals jordfelsövervakning Megacon AB Ranhammarsvägen 20 168 67 Bromma Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee VARNING!

Läs mer

TM-6331H--1~4 TM ~4 TM-6331AB--1~2 TM ~4 TM-619H--1~4 TM-619L--1~4

TM-6331H--1~4 TM ~4 TM-6331AB--1~2 TM ~4 TM-619H--1~4 TM-619L--1~4 DIGITAL TIMER 619-Programmeringsläge Användarmanual TM-6331H--1~4 TM-6331--1~4 TM-6331AB--1~2 TM-619--1~4 TM-619H--1~4 TM-619L--1~4 Control Logic (Lithium CR2032 säkerhetskopiering minne, utbytbart) Denna

Läs mer

Öppnaknapp Scoria Touch

Öppnaknapp Scoria Touch Öppnaknapp är en öppnaknapp som fungerar dels som oberoende öppnaknapp (Stand Alone) i direkt samverkan med ett elektriskt lås, eller ansluten till ett passersystems undercentral. 1.0 Beskrivning 1.1 Introduktion

Läs mer

PSR-SCP-24 UC/ESAM4/8X1/1X2

PSR-SCP-24 UC/ESAM4/8X1/1X2 PSR-SCP-24 UC/ESAM4/8X1/1X2 För nödstopp/säkerhetsdörrar Kategori 4, EN 954-1 Jackbara anslutningar 1- eller 2-kanaligt Kortslutningsövervakning Byggbredd 45 mm (1.772 in.) 8 seriedubblerade utgångskontakter

Läs mer

ETANOLDAX Avancerad E85 konverterings modul. Användar manual Gäller för firmware 1.1 ( Rev.2SE)

ETANOLDAX Avancerad E85 konverterings modul. Användar manual Gäller för firmware 1.1 ( Rev.2SE) ETANOLDAX Avancerad E85 konverterings modul Användar manual Gäller för firmware 1.1 (2010.06.20Rev.2SE) INDEX Inledning... 3 Installation.... 4 Funktioner.... 6 Kallstartsfunktioner..7 Konfigureringsläge..

Läs mer

REB 103 och REB 101 1 MDBO5006-SV. Saml i ngsskeneskydd. Allmänt. Användning. ABB Network Controi & Protection

REB 103 och REB 101 1 MDBO5006-SV. Saml i ngsskeneskydd. Allmänt. Användning. ABB Network Controi & Protection Saml i ngsskeneskydd Sida 1 Oktober 1994 Rätt till ändringar utan föregående meddelande förbehålles ABB Network Controi Allmänt Användning.Baserad på en väl beprövad och extremt snabb mätning av differentialströmmar

Läs mer

SPAJ 135 C. Kombinerat överströmsoch jordfelsrelä SPAJ 135 C. Bruksanvisning och teknisk beskrivning V ~ V. U aux.

SPAJ 135 C. Kombinerat överströmsoch jordfelsrelä SPAJ 135 C. Bruksanvisning och teknisk beskrivning V ~ V. U aux. SPAJ 135 C Kombinerat överströmsoch jordfelsrelä Bruksanvisning och teknisk beskrivning I n = 1A 5A ( I ) I n = 1A 5A ( I o ) f n = 50Hz 60Hz 2 5 B I L1 I L3 I o 2 I > I IRF SPAJ 135 C 80...265V ~ 18...80V

Läs mer

BE Fresh water pump station ver 2.03. Systembeskrivning. 2011-02-21 Svenska

BE Fresh water pump station ver 2.03. Systembeskrivning. 2011-02-21 Svenska BE Fresh water pump station ver 2.03 Systembeskrivning 2011-02-21 Svenska Förord Systembeskrivning för BE Fresh water pump station Förord Denna lösning är framtagen för att konfigurera upp, styra och övervaka

Läs mer

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB D

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB D Dokumentslag Verksamhetsstyrande 1 (14) Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB D10-0017759 2.0 Organisation Giltig fr o m Giltig t o m Anläggning 2016-11-17 Dokumentansvarig

Läs mer

Originalbruksanvisning AS-i Safety-kretskort E7015S 7390842/00 07/2010

Originalbruksanvisning AS-i Safety-kretskort E7015S 7390842/00 07/2010 Originalbruksanvisning AS-i Safety-kretskort E7015S 7390842/00 07/2010 Innehåll Säkerhetsanvisningar 3 Installation/idriftsättning 4 Montering/elektrisk anslutning 5 Reaktionstider 8 Anmärkning angående

Läs mer

Installationsmanual Multiläsare 2000 användare 12V DC Revidering 1.00

Installationsmanual Multiläsare 2000 användare 12V DC Revidering 1.00 ML 1540 Installationsmanual Multiläsare 2000 användare 12V DC Revidering 00 Innehåll Översikt... 3 Produktbeskrivning... 3 Utmärkande egenskaper... 3 Användning... 3 Larmfunktion... 4 Återställning larm...

Läs mer

Ingång Utgång - anslutningstyp Specifikationer Mätområde (1) AC (växelström) DC (likström) Spänning. ström 10 V AC 0.1 V AC

Ingång Utgång - anslutningstyp Specifikationer Mätområde (1) AC (växelström) DC (likström) Spänning. ström 10 V AC 0.1 V AC ATT VÄLJA RÄTT STRÖMTÅNG Genom att svara på dessa frågor kan du enkelt välja en tång för din applikation: 1- Är det en mätning av AC eller DC (DC tänger skrivs som AC/DC tänger eftersom de mäter båda marna).

Läs mer

Ett heltäckande koncept för smarta elnät i form av störningsanalysator och reläskydd

Ett heltäckande koncept för smarta elnät i form av störningsanalysator och reläskydd dlaboratory making the grid smart Ett heltäckande koncept för smarta elnät i form av störningsanalysator och reläskydd Insikt i elnätets status är en viktig del för att upprätthålla ett elnät med hög leveranssäkerhet

Läs mer

Relion 615 serie. Transformatorskydd och styrning RET615

Relion 615 serie. Transformatorskydd och styrning RET615 Relion 65 serie Transformatorskydd och styrning RET65 Kompakt och mångsidig lösning för kraftdistributionssystem för energiföretag och industrier RET65 är en dedikerad IED (intelligent electronic device),

Läs mer

MOTORTESTER COMPACT TR-1000

MOTORTESTER COMPACT TR-1000 MOTORTESTER COMPACT TR-1000 BRUKSANVISNING ALLMÄNT MOTORTESTER COMPACT TR 1000 är ett instrument för säker och snabb felsökning av elmotorer, stator och rotor. Mätprincipen är enkel och fel identifieras

Läs mer

SPA-ZC 17. Bussanslutningsmodul SPA-ZC 17. Bruksanvisning och teknisk beskrivning. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0 RS 951 014

SPA-ZC 17. Bussanslutningsmodul SPA-ZC 17. Bruksanvisning och teknisk beskrivning. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0 RS 951 014 SPA-ZC 17 Bussanslutningsmodul Bruksanvisning och teknisk beskrivning 1 2 3 4 5 6 7 8 O N SPA / RS 485 SPA 1100000 RS 485 0011110 SLAVE 1 MASTER 0 Tx SC Rx 2 5 Uaux 80...265 V ~ 18...80 V SPA-ZC 17 RS

Läs mer

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT-091123-028 D10-0015690 1.0

Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT-091123-028 D10-0015690 1.0 Dokumentslag Verksamhetsstyrande 1 (12) Företag Ersätter tidigare dokument Dokumentid Utgåva E.ON Elnät Sverige AB NUT-091123-028 D10-0015690 1.0 Organisation Giltig fr o m Giltig t o m Anläggning 2014-04-24

Läs mer

Brand-/Brandgasspjällstyrning för två spjäll m. rökdetektor 8SC2:004, 8SC2-1:004 (endast ett spjäll)

Brand-/Brandgasspjällstyrning för två spjäll m. rökdetektor 8SC2:004, 8SC2-1:004 (endast ett spjäll) Produktbeskrivning: Brand-/Brandgasspjällstyrning Funktion: SIOX-modul: Processbild: Brand-/Brandgasspjällstyrning för två spjäll m. rökdetektor 8SC2:004, 8SC2-1:004 (endast ett spjäll) 8SC2_004.DFF Inkopplingsbeskrivning

Läs mer

Bevent Rasch RCTC. - Brand Övervakningssystem Programversion 1.25

Bevent Rasch RCTC. - Brand Övervakningssystem Programversion 1.25 Bevent Rasch - Brand Övervakningssystem - RCTC 2017-05-17 Programversion 1.25 Centralenhet RCTC Central för anslutning av spjällmoduler RCTU Med expansionsenheter kan upp till 236 spjäll hanteras Inbyggt

Läs mer

Manual Nödljusaggregat MAPOWER

Manual Nödljusaggregat MAPOWER Manual Nödljusaggregat MAPOWER Sida Innehållsförteckning 1 Säkerhet, Presentation, 2 Funktionsbeskrivning 3 Driftsättning 4 Kopplingsexempel 4/5 Tekniska data / Interna säkringar 5 Batterimontage 6 Felsökning

Läs mer

Application Note SW

Application Note SW TWINSAFE DIAGNOSTIK TwinSAFE är Beckhoffs safety-lösning. En översikt över hur TwinSAFE är implementerat, såväl fysiskt som logiskt, finns på hemsidan: http://www.beckhoff.se/english/highlights/fsoe/default.htm?id=35572043381

Läs mer

ÅTERINKOPPLINGS- AUTOMATIK

ÅTERINKOPPLINGS- AUTOMATIK SvK4005, v3.3, 2012-08-09 ENHET, VERKSAMHETSOMRÅDE NK, Kontrollanläggning VÅR BETECKNING TR02-06-3 DATUM 1996-11-15 TEKNISK RIKTLINJE UTGÅVA C ÅTERINKOPPLINGS- AUTOMATIK 1/8 Uppdateringar Utgåva Ändringsnot

Läs mer

DALI Styrning W AGO Kontakttechnik GmbH & Co. KG, PMA, ToK/JBe 02/2010 1

DALI Styrning W AGO Kontakttechnik GmbH & Co. KG, PMA, ToK/JBe 02/2010 1 DALI Styrning W AGO Kontakttechnik GmbH & Co. KG, PMA, ToK/JBe 02/2010 1 Vad är DALI? WAGO Kontakttechnik GmbH & Co. KG, PMA, ToK/JBe 02/2010 2 DALI Digital Addressable Lighting Interface DALI är en öppen

Läs mer