FEBY Kriteriejämförelse av Passivhus enligt PHI och FEBY. Positioning Paper



Relevanta dokument
Kravspecifikation för passivhus i Sverige Energieffektiva bostäder

Är passivhus lämpliga i fjärrvärmeområden?

Stiftelsen Allmänna Barnhuset KARLSTADS UNIVERSITET

Passivhus ur en brukares perspektiv

Alla Tiders Kalmar län, Create the good society in Kalmar county Contributions from the Heritage Sector and the Time Travel method

Adding active and blended learning to an introductory mechanics course

Daylight and thermal comfort in a residential passive house

Utveckling av energimarknader i EU. politik och framgångsrika medlemsstater

Lågtemperaturfjärrvärme i nya bostadsområden P i samverkan med Växjö kommun, Växjö Energi AB och Växjö-bostäder AB

SWESIAQ Swedish Chapter of International Society of Indoor Air Quality and Climate

Arbetstillfällen

Custom-made software solutions for increased transport quality and creation of cargo specific lashing protocols.

Värmeförlusteffekt (FEBY12)

Tekn. Konsult Lars B. Bergman LB-Hus AB Tekn. Chef Esse Ingesson VästkustStugan. Tekn. Expert Svante Wijk

Vad händer på Passivhusfronten?

Swedish adaptation of ISO TC 211 Quality principles. Erik Stenborg

Isolda Purchase - EDI

IEA Task 41 Solar Energy and Architecture IEA SHC Solar Cooling and Heating programme

Beräkning av köldbryggor saknas en gemensam definition?

Högåsskolan. - a passive house school. 7phn Copenhagen, August 2015

Solar angles Solar height h, Azimuth (bearing) a

Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

Split- vs ventilationsaggregat

Kan framtidens byggnader klara sig utan energiförsörjningssystem?

Uttagning för D21E och H21E

ISO STATUS. Prof. dr Vidosav D. MAJSTOROVIĆ 1/14. Mašinski fakultet u Beogradu - PM. Tuesday, December 09,

Boiler with heatpump / Värmepumpsberedare

ASES. Active Solar Energy Storage. Thule Brahed ERRIN EUSEW Brussels

Viktig information för transmittrar med option /A1 Gold-Plated Diaphragm

Welcome to: Design for energy-efficient construction. Elective course for A+W, AEB F01, 3hp. Spring 2008

Momento Silverline. To further protect the environment Momento introduces a new coating for our impact sockets - Momento Silverline

Ett hållbart boende A sustainable living. Mikael Hassel. Handledare/ Supervisor. Examiner. Katarina Lundeberg/Fredric Benesch

Writing with context. Att skriva med sammanhang

Goals for third cycle studies according to the Higher Education Ordinance of Sweden (Sw. "Högskoleförordningen")

Om oss DET PERFEKTA KOMPLEMENTET THE PERFECT COMPLETION 04 EN BINZ ÄR PRECIS SÅ BRA SOM DU FÖRVÄNTAR DIG A BINZ IS JUST AS GOOD AS YOU THINK 05

Analys och bedömning av företag och förvaltning. Omtentamen. Ladokkod: SAN023. Tentamen ges för: Namn: (Ifylles av student.

Kundfokus Kunden och kundens behov är centrala i alla våra projekt

SVENSK STANDARD SS-EN 13612/AC:2016

Support for Artist Residencies

PowerCell Sweden AB. Ren och effektiv energi överallt där den behövs

Wood Buildings. -Development in Sweden Niclas Svensson, Swedish Wood Building Council. Niclas Svensson, Swedish Wood Building Council

Eternal Employment Financial Feasibility Study

Kravspecifikation för passivhus i Sverige Energieffektiva bostäder

Aborter i Sverige 2008 januari juni

Läkemedelsverkets Farmakovigilansdag

SOLAR LIGHT SOLUTION. Giving you the advantages of sunshine. Ningbo Green Light Energy Technology Co., Ltd.

Introduktion ICAO-EASA.

The Algerian Law of Association. Hotel Rivoli Casablanca October 22-23, 2009

Innovation in the health sector through public procurement and regulation

FÖRBERED UNDERLAG FÖR BEDÖMNING SÅ HÄR

Kvalitetsarbete I Landstinget i Kalmar län. 24 oktober 2007 Eva Arvidsson

Olika uppfattningar om torv och

Svensk forskning och innovation om passivhus. Kristina Mjörnell SP Sveriges Tekniska Forskningsinstitut

SVENSK STANDARD SS-EN ISO 19108:2005/AC:2015

Nya driftförutsättningar för Svensk kärnkraft. Kjell Ringdahl EON Kärnkraft Sverige AB

FEBY12. Nollenergihus Passivhus Minienergihus. Sammanfattning av kravspecifikationer för bostäder

Tomas Stålnacke Huvudprojektledare Project Manager Stadsomvandlingen City in transformation Kirunabostäder AB

NORDIC GRID DISTURBANCE STATISTICS 2012

Presentation of the Inwido Group

Hållbar utveckling i kurser lå 16-17

Materialplanering och styrning på grundnivå. 7,5 högskolepoäng

12.6 Heat equation, Wave equation

Health café. Self help groups. Learning café. Focus on support to people with chronic diseases and their families

School of Management and Economics Reg. No. EHV 2008/220/514 COURSE SYLLABUS. Fundamentals of Business Administration: Management Accounting

Preschool Kindergarten

Att jobba som konsult i Kina CMB 16 December Våra erfarenheter 作 为 一 名 顾 问 在 中 国 工 作

ANSÖKAN OM INRÄTTANDE AV EXTERNT FINANSIERAT DOKTORANDPROJEKT ANNAN ARBETSGIVARE ÄN GÖTEBORGS UNIVERSITET

Kurskod: TAMS28 MATEMATISK STATISTIK Provkod: TEN1 05 June 2017, 14:00-18:00. English Version

Från Anna-Karin Hatts twitterkonto efter invigningen av Stadsskogenskolan Alingsås energiomställningens epicentrum!

Semantic and Physical Modeling and Simulation of Multi-Domain Energy Systems: Gas Turbines and Electrical Power Networks

Module 1: Functions, Limits, Continuity

4.2.3 MINERGIE URSPRUNG OCH ORGANISATION

Passivhus på Svenska. Forum för Energieffektiva Byggnader. Svein Ruud SP Energiteknik

Beijer Electronics AB 2000, MA00336A,

Regional Carbon Budgets

SVENSK STANDARD SS-EN ISO :2009/AC:2010

Surfaces for sports areas Determination of vertical deformation. Golvmaterial Sportbeläggningar Bestämning av vertikal deformation

Botnia-Atlantica Information Meeting

ISO general purpose metric screw threads Selected sizes for screws, bolts and nuts

INSTALLATION INSTRUCTIONS

Brandsäkerhet hos. ny europeisk handbok

Sara Skärhem Martin Jansson Dalarna Science Park

Why Steam Engine again??

CHANGE WITH THE BRAIN IN MIND. Frukostseminarium 11 oktober 2018

Collaborative Product Development:

CM FORUM. Introduktion till. Configuration Management (CM) / Konfigurationsledning. Tobias Ljungkvist

Nya upphandlingsdirektiv och upphandling av livsmedel

Kursplan. AB1029 Introduktion till Professionell kommunikation - mer än bara samtal. 7,5 högskolepoäng, Grundnivå 1

MILJÖBEDÖMNING AV BOSTÄDER Kvarteret Nornan, Glumslöv

ISO general purpose screw threads Basic profile Part 1: Metric screw threads

Kursplan. EN1088 Engelsk språkdidaktik. 7,5 högskolepoäng, Grundnivå 1. English Language Learning and Teaching

Measuring child participation in immunization registries: two national surveys, 2001

Indikatorer för utvecklingen av de Europeiska energisystemen

Stad + Data = Makt. Kart/GIS-dag SamGIS Skåne 6 december 2017

Affärsmodellernas förändring inom handeln

LUNDS TEKNISKA HÖGSKOLA Institutionen för Elektro- och Informationsteknik

PFC and EMI filtering

denna del en poäng. 1. (Dugga 1.1) och v = (a) Beräkna u (2u 2u v) om u = . (1p) och som är parallell

Transkript:

FEBY Kriteriejämförelse av Passivhus enligt PHI och FEBY Positioning Paper Background on implementation of Passive House in Sweden Framtagen med medel från Energimyndigheten November 2009 LTH rapport EBD-R--09/29 ATON rapport 0906 IVL rapport nr A1731 Forum för Energieffektiva Byggnader

Förord Styrgruppen för Energimyndighetens program för Passivhus och lågenergihus har givit Forum för Energieffektiva Byggnader (benämnt FEBY i texten nedan) i uppdrag att utarbeta en jämförelse mellan FEBYs kriterier och de som uppställts av tyska Passivhusinstitutet (PHI). Dokumentet är framtaget av en teknikgrupp inom FEBY bestående av följande personer: Eje Sandberg, ATON Teknik Konsult 1 Martin Erlandsson, IVL Svenska Miljöinstitutet Svein Ruud, SP Sveriges Tekniska Forskningsinstitut Ulla Janson, Lunds Tekniska Högskola 1 Huvudförfattare och kontaktperson: eje.sandberg@aton.se

1. Executive summary Positioning Paper This paper describes the implementation of Passive House design criteria in Sweden adapted to a Scandinavian climate, which differ from the middle Europe conditions. Furthermore, this paper describes the current difference between the Swedish definitions of Passive House compared to the common established definition from Passive House Institute (PHI) in Darmstadt. 1.1 The functional definition of the Passive House concept Passive house is a generic concept of design for very energy efficient buildings that has to be adapted to different regional climate conditions 2. The Passive House concept on how an ultimate energy performance requirement shall be established is based on the fact that if the air exchange required by fulfilling hygienic requirements also is utilised for heating, such building will not need to install a traditional additional heating system. This design concept, where the space heating is typically using the supply air ducts as a distribution system will be cost effective since a separate traditional heating system will not need to be installed. This surplus factor is gained by increased cost for improved thermal quality of the building, i.e. increased insulation of the façade, limited thermal bridges, very airtight building envelope, thermally high quality windows etc. The increased investment will however be paid pack in a life cycle perspective and improve the environmental performance of the building. This basis for energy efficiency is then transformed into a functional definition that constitutes a technical neutral norm that in principle allows development of different technical solutions (not limited to the supply air system for distribution of heat). The Passive House concept is thereby defined as a functional requirement and defined according to Feist 2 as: The primary function of the ventilation system is to maintain excellent indoor air quality. If the maximum load is lower than 10 W/m², the ventilation system can distribute all heat needed throughout the building as well. The definition of a Passive House is therefore that the peak heating load should be projected to a lower level than 10 W/m². While the functional definition of the Passive House concept remains over time, between region and countries its implementation to building standards may vary. In the first building standard that was developed by the Passive Hause Institute in Darmstadt the most essential requirement was the peak load for space heating. 1.2 History of the Swedish implementation The recognition of very low energy efficient buildings in Germany and elsewhere in Europe and the absence of this kind of buildings in Northern Europe was the starting point for the FEBY programme. In order to stimulate the Passive House concept in Sweden it was decided to support the establishment of this kind of buildings. With finical support from STEM 3 and VRG 4, FEBY have produced national guidelines for Passive Houses, training materials, program for evaluation and collecting of experiences for knowledge transfer. In the development for the national guidelines for Passive House it was a goal to follow the Passive House concept and to define a criteria document with definitions that allows difference in energy performance in different regions. Consequently, the definition of a Passive House in Sweden started with a definition valid for the south part of Sweden that is basically the same as the common European definition, which historically was developed by the Passive House Institute. However for the more northern regions, as well as for single family houses, it was decided that the heat load may be 2 Dr. Wolfgang Feist (2005): First Steps: What Can be a Passive House in Your Region with Your Climate? Passive House Institute, Darmstadt, p 7. Available at: http://www.passiv.de/07_eng/firststeps/first_f.htm 3 The Swedish Energy Agency (STEM). 4 Region Västra Götaland (VGR). 2

increased to make it cost effective to facilitate the Passive House concept also in these regions and for these types of houses. If the air exchange rang increases from 0,35 arch as used by PHI to 0,5 arch as required by the Swedish building code it would allow a raise of the heat distribution by 40%. In addition the lower dimensioning outdoor temperatures in the northern regions allows for higher energy supply without exceeding the maximum supply air temperature. In other words, the requirement for maximum heating power may be increased from 10 to 14 W/m 2 if the minimum air exchanges of 0,5 per hour that is required according to Swedish building code is followed and if the colder outdoor temperature is taken into account. 1.4 Criteria comparison This document aim to demonstrate the differences between the FEBY criteria and the criteria from Passive House Institute (PHI) for residential buildings. The Norwegian standard for PH is not studied. The criteria s and its calculation parameter data is different in many aspects, as in Table 1. Table 1. Parameters in the criteria documents. FEBY PHI/PHPP Heat demand at DUT < 10 14 W/m 2 < 10 W/m 2, or the energy criteria fulfilled Heat demand, < 200m2 < 12 16 W/m 2 < 10 W/m 2 Climate cooling demand < 15 kwh/m 2 Dim. outdoor temp. (DUT) SS 024310 PHI calculates two different DUT Heat energy demand - 15 kwh/m 2, or heat demand criteria Method of calculating As described in PM PHPP- program only Vent. air flow (Build stand) > 0,35 l/s, m 2 0,3 0,4 exchanges/h Air tightness 0,30 l/s, m 2 0,6 exchanges/h Free heat + sun at DUT 4 W/m 2 1,6 W/m 2 excl sun (ca 1 W/m 2 ) Free heat in year calculation Actual 2,8 W/m 2 U-value window 0,90 W/K, m 2 0,8 W/K, m 2 Um-value: - 0,15 W/K, m 2 (external area, excl. window areas) Ventilation heat exchange > 70% (recommended) > 75% (PHI method) Hot water 5 ) Sun/heat pump Primary energy 60 68 kwh/m 2 6 ) 120 kwh/m 2 (incl domestic electricity) Indoor temp when energy demand 22 ºC 20 ºC Maximum supply air temperature 52 ºC 52 ºC To complement Table 1 there are also other parameter data for calculating air leakages, the number of tenants, domestic hot water demand and electricity use for household appliances. The PHI criteria gives the choice between heat demand criteria and the energy criteria, while for FEBY, only the heat demand criteria is compulsory. The PHI criteria and calculation methods as described in the PHPP program will give some higher heat demand value for an identical two storey one family house, mainly because the air leakage is supposed to be 2,5 times higher at DUT compared to mean yearly leakage. But then the criteria s in PHI are at the same level also for the northern climates in Sweden and for houses < 200 m2 where the FEBY criteria are less demanding. 1.3 Experiences and outlook In the start, i.e. in the early 21th century, there was just a minimum interest for Passive Houses in Sweden. The work by FEBY to define de fact standards on low energy buildings was therefore of pioneer character. The definitions were adapted to Swedish calculation methods (and not a specific software) and the type of criteria definitely supports the adoption of the criteria document on the market. The major FEBY interest was to support all initiatives on Passive House concepts and launch the Passive House thinking from a concept to a current praxis. The Passive House criteria and the supplementary criteria for Mini Energy are now established on the market and we have to take the 5 Choosing more efficient hot water taps and end-use metering is an option in FEBY method. 6 Weighting factor 2,0 for electricity 3

concept further. Today, all large construction companies are building Passive Houses and the market is growing 7. FEBY have just introduced two types of certifications, one for planned building based on a self claim and one for buildings taken in to use based on third party review and monitored data. We have further refined the criteria for Passive House and have now an ambition to harmonise the Swedish criteria for Passive House with international initiatives. Furthermore, in the latest criteria document for a Passive House, we have also added a definition on a passive house as a zero energy building (that in practice means a net energy producer). 7 Projektrapport "Marknadsöversikt för passivhus och lågenergihus i Sverige 2008" 4

2. Jämförande beskrivning mellan FEBYs kriterier och tyska Passivhusinstitutets kriterier 2.1 Rapportens syfte Detta dokument syftar till att klarlägga skillnaderna mellan de svenska kriterierna utarbetade av FEBY och de tyska kriterierna utarbetade av det tyska Passivhusinstitutet (PHI). Vidare ges i rapporten en sammanfattande beskrivning av bakgrunden till det svenska arbetet med kriterier för Passivhus och det fortsatta arbetet. Denna del av rapporten är skriven på engelska för att läsare även från andra länder skall kunna få en inblick i arbetet som utförts av FEBY. PHI har inte utarbetat något kriteriedokument motsvarande FEBYs, men vissa centrala krav finns redovisade i många olika dokument, medan mer detaljerade förutsättningar framgår implicit i PHPP programmet och dess dokumentation och i ett av PHI utarbetat PM Certification as quality approved Passive House. Förutom PHI och FEBY kriterier har en norsk standard utarbetats för vad som i Norge ska anses vara ett passivhus. Denna standard relaterar sig de beräkningsförutsättningar och beräkningsmetoder som beskrivs i den norska standard som används för att definiera norska minimikrav för byggnaders energianvändning i nyproduktion (byggregler). Någon standard eller beräkningsanvisning finns inte kopplade till de svenska byggreglerna. Då ingen aktör för närvarande avser tillämpa de norska kriterierna görs ingen jämförelse med denna i detta dokument. 2.2 Detaljerad jämförelse Samtliga dessa kriterieuppsättningar baseras på den funktionella definitionen av Passivhus, dvs att värmebehovet kan klaras med en distribution av värme via tilluftens hygienluftsflöde 8. Det innebär att byggnadens värmeförluster ska vara så låga att hela värmebehovet vid dimensionerande utetemperatur kan bäras in i rummen genom en temperering av tilluften. Med de minimiflöden som krävs i Sverige och med de svenska kriterierna finns dock ett utrymme för att kunna bära ut en högre värmeeffekt än vad kravet anger. I norra Sverige hamnar kravnivån på gränsen till vad som är fysikaliskt möjligt att bära med tilluften. I följande tabell lämnas en övergripande jämförelse för de viktigare skillnaderna. 8 Dr. Wolfgang Feist (2005): First Steps: What Can be a Passive House in Your Region with Your Climate? Passive House Institute, Darmstadt. Available at: http://www.passiv.de/07_eng/firststeps/first_f.htm 5

Tabell 1. Jämförelse av olika parametrar i det svenska och tyska kriterierna för Passivhus FEBY PHI/PHPP Effektkrav, värme < 10 14 W/m 2 < 10 W/m 2, eller energikravet uppfyllt Effektkrav, småhus < 12 16 W/m 2 < 10 W/m 2, eller energikravet uppfyllt Klimatkyla 1) < 15 kwh/m 2 DUT SS024310 Egen (PHI) bestämning av två DUT Energikrav, värme - 15 kwh/m 2, eller effektkravet uppfyllt Beräkningsmetod Öppen redovisad PHPP- programmet Luftflöde > 0,35 l/s, m 2 0,3 0,4 oms/h Täthet 0,30 l/s, m 2 0,6 oms/h Spillvärme + sol vid DUT 4 W/m 2 1,6 W/m 2 exkl sol (ca 1 W/m 2 ) Spillvärme värmeber. verklig enl metod 2,8 W/m 2 U-värde fönster 0,90 W/K, m 2 0,8 W/K, m 2 Um-värde: 0,15 W/K, m 2 (definerat på extern area, exl fönster) Värmeåtervinning > 70% (börkrav) > 75% (skallkrav, egen mätmetod) Varmvatten 2) Sol/värmepump Primärenergi 60 68 kwh/m 2 3) 120 kwh/m 2 (inkl hushållsel) Innetemp vid värmeber. 22 ºC 20 ºC Max tilluftstemperatur 52 ºC 52 ºC 1) FEBY har ännu inte utarbetat kriterier för lokaler med verksamhet som har större spillvärmekällor utöver brukarna själva. 2) Val av bättre blandare och fördelningsmätning kan beaktas i energikalkylen. 3) Enl. BBRs definition för energiprestanda och viktning av elenergi med 2,0. Det lägre värdet för södra Sverige. Utöver de aspekter som, tas upp i tabell 1 skiljer sig kriterierna vad avser uppvärmd area, normalt brukande av varmvattenvolym och persontäthet, schablon för spillvärme i effektkalkylen, samt att PHPP antager ett 2,5 ggr större läckageflöde vid DUT än vid beräkning av årsenergi. 2.3 Konsekvensanalys Någon exakt jämförelse mellan de två kriteriebeskrivningarna kan inte göras eftersom det påverkas också av den aktuella byggnadens geometri. Jämförande beräkningar (PHPP, samt Energy Consol+) för ett identiskt småhus indikerar att de beräkningsmässigt ligger rätt nära varandra när samma indata för läckflöde används trots att olika klimatdefinitioner och därmed DUT-värden har använts. När däremot PHPPs 2,5 ggr högre läckflöde vid DUT tillämpas ger PHPP en större effektförlust. Detta ska tolkas som att FEBY har mindre stränga effektkrav även om samma effektförlust accepteras. Årsenergivärdet blir något högre med FEBY metod (högre innetemperatur) om PHPPs värde på spillvärme används i jämförelsen, annars lägre. Men, för småhus accepterar FEBY 20 % högre effektförluster än PHPP, vilket i praktiken ger ca 7 kwh/m 2 högre årsvärmebehov, netto. Vidare har FEBY 10 20% mildare krav jfr PHI för de två nordligare klimatzonerna. Motsvarande analys för ett flerbostadshus har inte gjorts. FEBYs kriterier möjliggör funktionskravsrelaterad kalkylering, medan PHPP kräver detaljerade uppgifter baserade på projekteringsdata. Med FEBYs kriterieuppsättning kommer för ett småhus placerat i Västerås krävas ungefär följande prestanda om ett FTX-aggregat med 82% verkningsgrad väljs: U-värde Typisk isolering (W/m 2,K) mm Yttervägg 0,09 400 Ytterdörr 0,8 Tak mot uteluft 0,09 500 Golv mot mark 0,07 400 Fönster 0,85 6

Värden enligt denna tabell ger ett U m värde exkl fönster på ca 0,11 W/m 2,K. Skulle detta småhus klara PHIs effektförlustkrav för ett småhus skulle dessa U-värden behöva vara minst 20% lägre. Figur 1. Passivhus illustration. Källa Passivhuscentrum, Alingsås. För ett flerbostadshus, vars omslutande area per uppvärmd area är mindre än hälften jämfört med ett småhus, kan FEBYs effektkrav klaras med väsentligt mindre isolering och ett Um värde som hamnar på nivån 0,18, dvs högre jämfört med PHIs krav. Här ges ett exempel för en byggnad på 5 plan och 19% fönsterarea: U-värde Typisk isolering (W/m 2,K) mm Yttervägg, betongelement 0,16 250 Tak mot uteluft 0,07 600 Golv mot mark 0,18 200 Fönster, altandörrar 0,9 Denna jämförelse visar att FEBYs krav är mjukare för flerbostadshus jämfört med PHIs. Konsekvenserna av detta är att investeringskostnaderna för att uppfylla de svenska kraven blir lägre, men att energikostnaderna blir högre. PHIs krav på Um kan också gynna utvecklingen av passivhuskonstruktioner vilket är en aspekt som bör utvärderas och övervägas för framtida revideringar. 7

2.4 Intyg av uppfyllande av prestandakrav för passivhusbyggnader Även sättet att certifiera byggnaden eller byggnadsprocessen skiljer sig åt. FEBY PHI/PHPP Projektansvarig Certifierad (utbildning) Komponenter PHI certifierade Beräknad byggnad Egendeklaration PHI/PHPP (detaljerad kontroll) 1) Certifierat Passivhus Avvikelser i genomförande deklareras Täthet Provning Provning Uppförd byggnad Tredjepartsgranskning Ingen mätning av effekt/energi. Verifierat Passivhus, med mätdata för effektförlustmätning och/eller årsenergiprestanda. 1) Om byggnaden ska certifieras ska samtliga handlingar och en detaljerad dokumentation av alla detaljlösningar redovisas och granskas av PHI. Med nuvarande utformning av BBR har fokus i Sverige gått mot en uppföljning av verkligt resultat för årsenergi. Eftersom de svenska kriterierna ännu inte innehåller krav på årsenergi (endast rekommendationer, i avvaktan på koncensus runt viktningsfaktorer) och erfarenheter ännu inte finns för hur den typen av uppföljningar ske göras och inte heller från effektförlustmätning, så finns heller inga erfarenheter av hur stora mätonogrannheter och därmed resultatavvikelser som kan accepteras. FEBYs metodik för certifiering som är baserad på en egendeklaration för den projekterade byggnaden och följer ISO 14021 och blir väsentligt enklare än motsvarande mycket detaljerade kontroll via PHI. 8

Ytterligare rapporter från Forum för Energieffektiva Byggande finns på http://www.energieffektivabyggnader.se/