Loose tube kabel för direktförläggning

Relevanta dokument
Fig. 2: Inkoppling av lindningarna / Winding wiring diagram

SOLAR LIGHT SOLUTION. Giving you the advantages of sunshine. Ningbo Green Light Energy Technology Co., Ltd.

Windlass Control Panel v1.0.1

GJUTEN ALUMINIUMPLATTA EN AW 5083 CAST ALUMINIUM PLATE EN AW 5083

Schenker Privpak AB Telefon VAT Nr. SE Schenker ABs ansvarsbestämmelser, identiska med Box 905 Faxnr Säte: Borås

Application Note SW

PROFINET MELLAN EL6631 OCH EK9300

HANTERING AV UPS CX

Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

DRIVERS PG 2-9 DRIVERS

SVENSK STANDARD SS-EN ISO 19108:2005/AC:2015

How to format the different elements of a page in the CMS :

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENS LÄS IGENOM INSTRUKTIONSMANUALEN

Metodprov för kontroll av svetsmutterförband Kontrollbestämmelse Method test for inspection of joints of weld nut Inspection specification

GigaCom AB Säterigatan Göteborg

FÖRBERED UNDERLAG FÖR BEDÖMNING SÅ HÄR

SVENSK STANDARD SS :2015

PORTSECURITY IN SÖLVESBORG

Beijer Electronics AB 2000, MA00336A,

TOMMY. lights made of shockproof resin material, UV-rays stabilized, rust and corrosionfree. Suitable for indoor and outdoor

TEXTURED EASY LOCK BLOCK INSTALLATION GUIDE. australianpaving.com.au

2.1 Installation of driver using Internet Installation of driver from disk... 3

FINA SWIMMING WORLD CUP 2004 the 13th and 14th of January 2004 in Stockholm, Sweden

A study of the performance

Dokumentnamn Order and safety regulations for Hässleholms Kretsloppscenter. Godkänd/ansvarig Gunilla Holmberg. Kretsloppscenter

ARC 32. Tvättställsblandare/Basin Mixer. inr.se

Instruction Manual. Svenska, English. Power Bank. Model: PRBN

District Application for Partnership

This manual should be saved! EcoFlush Manual

SVENSK STANDARD SS :2010

InstalationGuide. English. MODEL:150NHighGain/30NMiniUSBAdapter

Alias 1.0 Rollbaserad inloggning

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENSLÄS IGENOM INSTRUKTIONSMANUALEN NOGGRANT

STANDARD. UTM Ingegerd Annergren UTMS Lina Orbéus. UTMD Anders Johansson UTMS Jan Sandberg

Boiler with heatpump / Värmepumpsberedare

Lösenordsportalen Hosted by UNIT4 For instructions in English, see further down in this document

electiaprotect GSM SEQURITY SYSTEM Vesta EZ Home Application SMART SECURITY SYSTEMS! SVENSKA ios Android

Parking garage, Gamletull. MDM-piles, pre-installation testing RÄTT FRÅN GRUNDEN!

Slangupprullare. Hose Reels

Anvisning för Guide for

SHP / SHP-T Standard and Basic PLUS

Nyheter & tillägg. News & Additions. En äkta klassiker, återuppfunnen för vår tid igen! A true classic, reinvented for our time again!

INNOVATION HYDRAULSLANG MED ÖVERLÄGSEN PRESTANDA FÖR SKOGSAPPLIKATIONER

Tullverkets författningssamling

KARL ANDERSSON & SÖNER

Enterprise App Store. Sammi Khayer. Igor Stevstedt. Konsultchef mobila lösningar. Teknisk Lead mobila lösningar

UTLYSNING AV UTBYTESPLATSER VT12 inom universitetsövergripande avtal

Svenska()(Bruksanvisning(för(handdukstork()(1400(x(250(mm(

Materialplanering och styrning på grundnivå. 7,5 högskolepoäng

Adress 15. August 2014

Questionnaire for visa applicants Appendix A

Panel Source (Hona) (LSP***PS**), Panel Drain (Hane) (LSP***PD**), Line Source (Hona) (LSP***LS**), Line Drain (Hane) (LSP***LD**),

D-RAIL AB. All Rights Reserved.

Om oss DET PERFEKTA KOMPLEMENTET THE PERFECT COMPLETION 04 EN BINZ ÄR PRECIS SÅ BRA SOM DU FÖRVÄNTAR DIG A BINZ IS JUST AS GOOD AS YOU THINK 05

R min. 5 max

Läkemedelsverkets Farmakovigilansdag

55R Kia Carens 2013»

SVENSK STANDARD SS-EN ISO

This manual should be saved! EcoFlush Manual. Wostman 2018:2

55R Volvo XC » Volvo XC » Volvo S » Volvo V » Volvo XC » Volvo V »

karl andersson & söner

SVENSK STANDARD SS :2013

Styrteknik: Binära tal, talsystem och koder D3:1

KARL ANDERSSON & SÖNER

Företagsnamn: Grundfos Skapad av: Magnus Johansson Tel: +46(0) Datum:

Isolda Purchase - EDI

Systembeskrivning. Systemgaranti

Immigration Studying. Studying - University. Stating that you want to enroll. Stating that you want to apply for a course.

Monteringsanvisning Nödutrymningsbeslag ASSA 179E

Utfärdad av Compiled by Tjst Dept. Telefon Telephone Datum Date Utg nr Edition No. Dokumentnummer Document No.

Viktig information för transmittrar med option /A1 Gold-Plated Diaphragm

Nya driftförutsättningar för Svensk kärnkraft. Kjell Ringdahl EON Kärnkraft Sverige AB

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK

Wi-Fi travel router for ipad and mobile devices

< THE SHELF SYSTEM FILLED WITH POSSIBILITIES. Design Anne Krook

Your No. 1 Workout. MANUAL pro

Ringmaster RM3 - RM 5 RM3 RM 4 RM 5

FORTA M315. Installation. 218 mm.

NORIT Gipsprodukter. Gypsum fibre and dry lining products. Golvunderlag NORIT-TE Dry screed NORIT-TE LIMMA KLICKA FÄRDIG STICK CLICK READY

Quick Start. English Svenska PRIMACY. Printing settings and winsign

SVENSK STANDARD SS 1147:2015

Support Manual HoistLocatel Electronic Locks

Terms and Conditions Digital Sheet Music

Vässa kraven och förbättra samarbetet med hjälp av Behaviour Driven Development Anna Fallqvist Eriksson

Workplan Food. Spring term 2016 Year 7. Name:

Health café. Self help groups. Learning café. Focus on support to people with chronic diseases and their families

SEK TS Optokablar Kablar i avloppsledningar Familjespecifikation för kablar för förläggning i avloppsledningar

Förändrade förväntningar

AquaTeq Sweden AB Radarvägen 12 SE KALMAR. PHONE: +46 (0) INTERNET:

PORTSECURITY IN SÖLVESBORG

Mattor / tatamis T.V TRADING. 1. Allround Röd/Blå. 2. Allround Röd/svart samt trä-immitation. 3. WKF appr, Karate. 4. WTF appr, Taekwondo

CompactAIR Center Ventilation - Filtrering - Uppvärmning CompactAIR Center Ventilation - Filtration - Heating

GRADE PLUS ARMCHAIR DESIGN JOHANNES FOERSOM & PETER HIORT-LORENZEN

Transkript:

Loose tube kabel för direktförläggning Konstruktion: Glasfiberarmerad plaststav omgiven av fettfyllda tuber med upp till 12 fibrer i varje tub. Svälltejp runt tuberna ser till att kabeln är längsvattentät. Kabeln kan också fås med fett mellan tuberna istället för svälltejp. Det finns dock ingen teknisk fördel med att ha fett mellan tuberna och eftersom fettet förlänger installationstiden så rekommenderar vi svälltejp i första hand. rna omges av ett lager konstfibergarn för ökad draghållfasthet. Kabeln har först en PE mantel och över den har gjutits ytterligare en mantel av PA (nylon). Denna konstruktion ger ett mycket hårt yttre skal för att klara kraven på belastning upp till 3500 N över 10 cm samt för att klara att direktförläggas i mark. Kabeln kan inte tillverkas med en grön rand. Istället föreslår vi att hela den yttre manteln färgas med lämplig färg t ex grön för att undvika förväxling med elkabel. Kabeln kan fås med valfri fiberkvalitet. I prisbilagan har vi offererat med AllWave, som troligen är världens just nu bästa fiber. AllWave uppfyller G.652.D med mycket stor marginal och klarar därmed G.652.A, G.652.B och G.652.C med ännu större marginal. I prisbilagan återfinns denna kabel under följande produktkoder: AT-3BEZ2TT-012 AT-3BEZ2TT-024 AT-3BEZ2TT-036 AT-3BEZ2TT-048 AT-3BEZ2TT-060 AT-3BEZ2TT-072 AT-3BEZ2TT-096 AT-3BEZ2TT-144 AT-3BEZ2TT-192

5-Element Dry Core Cable Application Mainly used for direct burial and for Duct- Installation (HD-PE s) by Cable Pulling or Blowing Design Optical s Gel-filled Buffer s (2.5 mm) Non-metallic Central Member Water Blocking Material Non-metallic Strength Elements Ripcord PE-Jacket Nylon Outer-Jacket Features All Dielectric Cable Dry Core Design Cable core water blocked by means of dry water swellable technology - for quicker, cleaner cable prep for jointing Individual coloured tubes Nylon sheath provides higher mechanical and chemical resistance Green sheath offers easy identification If cable is used in direct buried application, then cable needs to be stress-free bedded in sand (EN 60974-1-1 C3.6.2) Version illustrated is the 60 Cable 1 2 3 4 5 AT-Code** 12 Blue 12F Filler* Filler* Filler* Filler* AT- Z2TT-012 24 Blue 12F Orange 12F Filler* Filler* Filler* AT- Z2TT-024 36 Blue 12F Orange 12F Green 12F Filler* Filler* AT- Z2TT-036 48 Blue 12F Orange 12F Green 12F Brown 12F Filler* AT- Z2TT-048 60 Blue 12F Orange 12F Green 12F Brown 12F Grey 12F AT- Z2TT-060 *Fillers are natural coloured **Please refer to the OFS AT- Code. The blanks specify the fibre type. Alternative tube colour code available on request Cable Diameter (calc.): Cable Weight (calc.): 12,0 mm 115 kg/km Page 1/2

Identification Colour Code: 1 Blue 5 Grey 9 Yellow 2 Orange 6 White 10 Violet 3 Green 7 Red 11 Rose 4 Brown 8 Black 12 Aqua 5-Element Dry Core Cable Sheath Marking: Mechanical Properties and Environmental Behaviour Tests according to EN 187105 and IEC 60794 OFS OPTICAL CABLE [ID] [MM/YY] [Handset-Sign] XXXF [Meter Marking] Alternative Sheath printing available on request Parameter Requirement Value Tensile Performance: Long term load - No attenuation increase* Load: 1000 N EN 187105-5.5.4 - No fibre strain IEC 60794-1-2-E1A and E1B Short term load, - No changes in attenuation Load: 2700 N during installation - Max. fibre strain 0.33% Crush Performance: Long term load - No attenuation increase* Load (Plate / Plate): 500 N EN 187105-5.5.3 Short term load - No changes in attenuation Load (Plate / Plate): 3500 N IEC 60794-1-2-E3 - No damage** Bending Performance: Handling fixed installed - No attenuation increase* Bend radius: 15 x D EN 187105-5.5.1 During installation - No changes in attenuation Bend radius: 20 x D IEC 60794-1-2-E11 (under load) D is cable diameter Temperatures: Operation - No attenuation increase* -30 to +70 C EN 187105-5.6.1 Installation -15 to +60 C IEC 60794-1-2-F1 Storage/Shipping -40 to +70 C * No changes in attenuation means that any changes in measurement value, either positive or negative within the uncertainty of measurement shall be ignored. The total uncertainty of measurement shall be less than of equal to 0.05 db. ** Mechanical damage when examined visually without magnification, there shall be no evidence of damage to the sheath. The imprint of plates will not be considered as damage. Shipping Information Cable Length Drum Dimensions (approx.) Shipping Weight (calc.) Diameter(battened) Width Without lagging With lagging 2000 m 1250 mm 790 mm 310 kg 343 kg 4000 m 1450 mm 790 mm 540 kg 580 kg 6000 m 1600 mm 1055 mm 800 kg 858 kg The shipping information are given for one-way reels. Reusable reels are available on request. The information is believed to be accurate at time of issue. OFS reserves the right to improve, enhance and modify the features and specifications of OFS products without prior notification. Please ensure you have the latest version of the data sheet. This data sheet is property of OFS. For additional information please contact your sales representative. You can also visit our website at http://www.ofsoptics.com. Telephone: +49 (0) 228 7489 201 Email: cableinfo@ofsoptics.com Page 2/2

6-Element Dry Core Cable Application Mainly used for direct burial and for Duct- Installation (HD-PE s) by Cable Pulling or Blowing Design Optical s Gel-filled Buffer s (2.5 mm) Non-metallic Central Member Water Blocking Material Non-metallic Strength Elements Ripcord PE-Jacket Nylon Outer -Jacket Features All Dielectric Cable Dry Core Design Cable core water blocked by means of dry water swellable technology - for quicker, cleaner cable prep for jointing Individual coloured tubes Nylon sheath provides higher mechanical and chemical resistance Green sheath offers easy identification If cable is used in direct buried application, then cable needs to be stress-free bedded in sand (EN 60974-1-1 C3.6.2) Version illustrated is the 72 Cable 1 2 3 4 5 6 AT-Code** 72 Blue 12F Orange 12F Green 12F Brown 12F Grey 12F White 12F AT- Z2TT-072 *Fillers are natural coloured **Please refer to the OFS AT- Code. The blanks specify the fibre type. Alternative tube colour code available on request Cable Diameter (calc.): Cable Weight (calc.): 12,8 mm 130 kg/km Page 1/2

Identification Colour Code: 1 Blue 5 Grey 9 Yellow 2 Orange 6 White 10 Violet 3 Green 7 Red 11 Rose 4 Brown 8 Black 12 Aqua 6-Element Dry Core Cable Sheath Marking: Mechanical Properties and Environmental Behaviour Tests according to EN 187105 and IEC 60794 OFS OPTICAL CABLE [ID] [MM/YY] [Handset-Sign] XXXF [Meter Marking] Alternative Sheath printing available on request Parameter Requirement Value Tensile Performance: Long term load - No attenuation increase* Load: 1000 N EN 187105-5.5.4 - No fibre strain IEC 60794-1-2-E1A and E1B Short term load, - No changes in attenuation Load: 2700 N during installation - Max. fibre strain 0.33% Crush Performance: Long term load - No attenuation increase* Load (Plate / Plate): 500 N EN 187105-5.5.3 Short term load - No changes in attenuation Load (Plate / Plate): 3500 N IEC 60794-1-2-E3 - No damage** Bending Performance: Handling fixed installed - No attenuation increase* Bend radius: 15 x D EN 187105-5.5.1 During installation - No changes in attenuation Bend radius: 20 x D IEC 60794-1-2-E11 (under load) D is cable diameter Temperatures: Operation - No attenuation increase* -30 to +70 C EN 187105-5.6.1 Installation -15 to +60 C IEC 60794-1-2-F1 Storage/Shipping -40 to +70 C * No changes in attenuation means that any changes in measurement value, either positive or negative within the uncertainty of measurement shall be ignored. The total uncertainty of measurement shall be less than of equal to 0.05 db. ** Mechanical damage when examined visually without magnification, there shall be no evidence of damage to the sheath. The imprint of plates will not be considered as damage. Shipping Information Cable Length Drum Dimensions (approx.) Shipping Weight (calc.) Diameter(battened) Width Without lagging With lagging 2000 m 1250 mm 790 mm 340 kg 373 kg 4000 m 1600 mm 1055 mm 630 kg 688 kg 6000 m 1600 mm 1055 mm 890 kg 948 kg The shipping information are given for one-way reels. Reusable reels are available on request. The information is believed to be accurate at time of issue. OFS reserves the right to improve, enhance and modify the features and specifications of OFS products without prior notification. Please ensure you have the latest version of the data sheet. This data sheet is property of OFS. For additional information please contact your sales representative. You can also visit our website at http://www.ofsoptics.com. Telephone: +49 (0) 228 7489 201 Email: cableinfo@ofsoptics.com Page 2/2

8-Element Dry Core Cable Application Mainly used for direct burial and for Duct- Installation (HD-PE s) by Cable Pulling or Blowing Design Optical s Gel-filled Buffer s (2.5 mm) Non-metallic Central Member Water Blocking Material Non-metallic Strength Elements Ripcord PE-Jacket Nylon Outer-Jacket Features All Dielectric Cable Dry Core Design Cable core water blocked by means of dry water swellable technology - for quicker, cleaner cable prep for jointing Individual coloured tubes Nylon sheath provides higher mechanical and chemical resistance Green sheath offers easy identification If cable is used in direct buried application, then cable needs to be stress-free bedded in sand (EN 60974-1-1 C3.6.2) Version illustrated is the 96 Cable 1 2 3 4 5 6 7 8 AT-Code** 96 Bl 12F Org 12F Gn 12F Bn 12F Gr 12F Wht 12F Rd 12F Blk 12F AT- Z2TT-096 *Fillers are natural coloured **Please refer to the OFS AT- Code. The blanks specify the fibre type. Alternative tube colour code available on request Cable Diameter (calc.): Cable Weight (calc.): 14,4 mm 170 kg/km Colour Abbreviations: Bl=Blue / Org= Orange / Gn=Green / Bn=Brown / Gr= Grey / Wht= White / Rd=Red / Blk= Black Page 1/2

Identification Colour Code: 1 Blue 5 Grey 9 Yellow 2 Orange 6 White 10 Violet 3 Green 7 Red 11 Rose 4 Brown 8 Black 12 Aqua 8-Element Dry Core Cable Sheath Marking: Mechanical Properties and Environmental Behaviour Tests according to EN 187105 and IEC 60794 OFS OPTICAL CABLE [ID] [MM/YY] [Handset-Sign] XXXF [Meter Marking] Alternative sheath printing available on request Parameter Requirement Value Tensile Performance: Long term load - No attenuation increase* Load: 1000 N EN 187105-5.5.4 - No fibre strain IEC 60794-1-2-E1A and E1B Short term load, - No changes in attenuation Load: 2700 N during installation - Max. fibre strain 0.33% Crush Performance: Long term load - No attenuation increase* Load (Plate / Plate): 500 N EN 187105-5.5.3 Short term load - No changes in attenuation Load (Plate / Plate): 3500 N IEC 60794-1-2-E3 - No damage** Bending Performance: Handling fixed installed - No attenuation increase* Bend radius: 15 x D EN 187105-5.5.1 During installation - No changes in attenuation Bend radius: 20 x D IEC 60794-1-2-E11 (under load) D is the cable diameter Temperatures: Operation - No attenuation increase* -30 to +70 C EN 187105-5.6.1 Installation -15 to +60 C IEC 60794-1-2-F1 Storage/Shipping -40 to +70 C * No changes in attenuation means that any changes in measurement value, either positive or negative within the uncertainty of measurement shall be ignored. The total uncertainty of measurement shall be less than of equal to 0.05 db. ** Mechanical damage when examined visually without magnification, there shall be no evidence of damage to the sheath. The imprint of plates will not be considered as damage. Shipping Information Cable Length Drum Dimensions (approx.) Shipping Weight (calc.) Diameter(battened) Width Without lagging With lagging 2000 m 1250 mm 790 mm 420 kg 453 kg 4000 m 1600 mm 1055 mm 790 kg 848 kg 6000 m 1750 mm 1055 mm 1150 kg 1276 kg The shipping information are given for one-way reels. Reusable reels are available on request. The information is believed to be accurate at time of issue. OFS reserves the right to improve, enhance and modify the features and specifications of OFS products without prior notification. Please ensure you have the latest version of the data sheet. This data sheet is property of OFS. For additional information please contact your sales representative. You can also visit our website at http://www.ofsoptics.com. Telephone: +49 (0) 228 7489 201 Email: cableinfo@ofsoptics.com Page 2/2

12-Element Dry Core Cable Application Mainly used for direct burial and for Duct- Installation (HD-PE s) by Cable Pulling or Blowing Design Optical s Gel-filled Buffer s (2.5 mm) Non-metallic Central Member Water Blocking Material Non-metallic Strength Elements Ripcord PE-Jacket Nylon Outer-Jacket Features All Dielectric Cable Dry Core Design Cable core water blocked by means of dry water swellable technology - for quicker, cleaner cable prep for jointing Individual coloured tubes Nylon sheath provides higher mechanical and chemical resistance Green sheath offers easy identification If cable is used in direct buried application, then cable needs to be stress-free bedded in sand (EN 60974-1-1 C3.6.2) Version illustrated is the 144 Cable 1 2 3 4 5 6 144 Blue 12F Orange 12F Green 12F Brown 12F Grey 12F White 12F 7 8 9 10 11 12 144 Red 12F Black 12F Yellow 12F Violet 12F Rose 12F Aqua 12F *Fillers are natural coloured Alternative tube colour code available on request AT-Code** 144 AT- Z2TT-144 **Please refer to the OFS AT- Code. The blanks specify the fibre type. Cable Diameter (calc.): Cable Weight (calc.): 17,6 mm 235 kg/km Page 1/2

12-Element Dry Core Cable Identification Colour Code: 1 Blue 5 Grey 9 Yellow 2 Orange 6 White 10 Violet 3 Green 7 Red 11 Rose 4 Brown 8 Black 12 Aqua Sheath Marking: OFS OPTICAL CABLE [ID] [MM/YY] [Handset-Sign] XXXF [Meter Marking] Alternative sheath printing available on request Mechanical Properties and Environmental Behaviour Tests according to EN 187105 and IEC 60794 Parameter Requirement Value Tensile Performance: Long term load - No attenuation increase* Load: 1000 N EN 187105-5.5.4 - No fibre strain IEC 60794-1-2-E1A and E1B Short term load, - No changes in attenuation Load: 2700 N during installation - Max. fibre strain 0.33% Crush Performance: Long term load - No attenuation increase* Load (Plate / Plate): 500 N EN 187105-5.5.3 Short term load - No changes in attenuation Load (Plate / Plate): 3500 N IEC 60794-1-2-E3 - No damage** Bending Performance: Handling fixed installed - No attenuation increase* Bend radius: 15 x D EN 187105-5.5.1 During installation - No changes in attenuation Bend radius: 20 x D IEC 60794-1-2-E11 (under load) D is the cable diameter Temperatures: Operation - No attenuation increase* -30 to +70 C EN 187105-5.6.1 Installation -15 to +60 C IEC 60794-1-2-F1 Storage/Shipping -40 to +70 C * No changes in attenuation means that any changes in measurement value, either positive or negative within the uncertainty of measurement shall be ignored. The total uncertainty of measurement shall be less than of equal to 0.05 db. ** Mechanical damage when examined visually without magnification, there shall be no evidence of damage to the sheath. The imprint of plates will not be considered as damage. Shipping Information Cable Length Drum Dimensions (approx.) Shipping Weight (calc.) Diameter(battened) Width Without lagging With lagging 2000 m 1600 mm 1055 mm 580 kg 638 kg 4000 m 1750 mm 1055 mm 1070 kg 1196 kg 6000 m 2050 mm 1100 mm 1560 kg 1686 kg The shipping information are given for one-way reels. Reusable reels are available on request. The information is believed to be accurate at time of issue. OFS reserves the right to improve, enhance and modify the features and specifications of OFS products without prior notification. Please ensure you have the latest version of the data sheet. This data sheet is property of OFS. For additional information please contact your sales representative. You can also visit our website at http://www.ofsoptics.com. Telephone: +49 (0) 228 7489 201 Email: cableinfo@ofsoptics.com Page 2/2

Access and Trunk Network 19-Element Dry Core Cable Application Mainly used for direct burial and for Duct- Installation (HD-PE s) by Cable Pulling or Blowing Design Optical s Gel-filled Buffer s (2.5 mm) Non-metallic Central Member Water Blocking Tape Non-metallic Strength Elements Ripcords PE-Inner Jacket Nylon-Outer Jacket Features All Dielectric Cable Dry Core Design Cable core water blocked by means of dry water swellable technology - for quicker, cleaner cable prep for jointing Two Layer Design for a smaller cable diameter and less cable weight Individual coloured tubes Nylon sheath provides higher mechanical and chemical resistance Green sheath offers easy identification If cable is used in direct buried application, then cable needs to be stress-free bedded in sand (EN 60974-1-1 C3.6.2) Version illustrated is the 192 Cable 1 2 3 4 5 6 AT-Code** 228 Blue Filler Orange Filler Green Filler AT- Z2TT-192 7 8 9 10 11 12 228 Blue Orange Green Brown Grey White Red Black Yellow Violet Rose Aqua Blue *Fillers are natural coloured **Please refer to the OFS AT- Code. The blanks specify the fibre type. 13 14 15 16 17 18 19 Cable Diameter (calc.): Cable Weight (calc.): 18,4 mm 235 kg/km Page 1/2

Identification Fiber Colour Code: 1 Blue 5 Grey 9 Yellow 2 Orange 6 White 10 Violet 3 Green 7 Red 11 Rose 4 Brown 8 Black 12 Aqua Access and Trunk Network 19-Element Dry Core Cable Sheath Marking: Mechanical Properties and Environmental Behaviour Tests according to EN 187105 and IEC 60794 OFS OPTICAL CABLE [ID] [MM/YY] [Handset-Sign] XXXF [Meter Marking] Alternative sheath printing available on request Parameter Requirement Value Tensile Performance: Long term load - No attenuation increase* Load: 1000 N EN 187105-5.5.4 - No fibre strain IEC 60794-1-2-E1A and E1B Short term load, - No changes in attenuation Load: 2700 N during installation - Max. fibre strain 0.33% Crush Performance: Long term load - No attenuation increase* Load (Plate / Plate): 500 N EN 187105-5.5.3 Short term load - No changes in attenuation Load (Plate / Plate): 3500 N IEC 60794-1-2-E3 - No damage** Bending Performance: Handling fixed installed - No attenuation increase* Bend radius: 15 x D EN 187105-5.5.1 During installation - No changes in attenuation Bend radius: 20 x D IEC 60794-1-2-E11 (under load) D is the cable diameter Temperatures: Operation - No attenuation increase* -30 to +70 C EN 187105-5.6.1 Installation -15 to +60 C IEC 60794-1-2-F1 Storage/Shipping -40 to +70 C * No changes in attenuation means that any changes in measurement value, either positive or negative within the uncertainty of measurement shall be ignored. The total uncertainty of measurement shall be less than of equal to 0.05 db. ** Mechanical damage when examined visually without magnification, there shall be no evidence of damage to the sheath. The imprint of plates will not be considered as damage. Shipping Information Cable Length Drum Dimensions (approx.) Shipping Weight (calc.) Diameter(battened) Width Without lagging With lagging 2000 m 1600 mm 1055 mm 580 kg 638 kg 4000 m 1750 mm 1055 mm 1070 kg 1196 kg 6000 m 2450 mm 1200 mm 1595 kg 1721 kg The shipping information are given for one-way reels. Reusable reels are available on request. The information is believed to be accurate at time of issue. OFS reserves the right to improve, enhance and modify the features and specifications of OFS products without prior notification. Please ensure you have the latest version of the data sheet. This data sheet is property of OFS. For additional information please contact your sales representative. You can also visit our website at http://www.ofsoptics.com. Telephone: +49 (0) 228 7489 201 Email: cableinfo@ofsoptics.com Page 2/2