POOL 310. Installatörshandbok Dockningssats pool. Installer manual Docking kit pool. Installateurhandbuch Anschlusssatz Pool

Relevanta dokument
POOL 40. Installatörshansbok POOL 40 för NIBE F1145, F1245. Installer manual POOL 40 for NIBE F1145, F1245

SOLAR 40. Installatörshansbok SOLAR 40 för NIBE F1145. Installer manual SOLAR 40 for NIBE F1145. Installateurhandbuch SOLAR 40 für NIBE F1145

POOL 310. Installatörshandbok Dockningssats pool. Installer manual Docking kit pool. Installateurhandbuch Anschlusssatz Pool

PCS 44. Installatörshansbok Passiv kyla för NIBE F1145, F1245. Installer manual Passive cooling for NIBE F1145, F1245

SOLAR 42. Installatörshandbok SOLAR 42 för NIBE F1145. Installer manual SOLAR 42 for NIBE F1145. Installateurhandbuch SOLAR 42 für NIBE F1145

Installatörshandbok AXC 40

POOL 310. Installatörshandbok Dockningssats pool SE. Installer manual Docking kit pool GB. Installateurhandbuch Anschlusssatz Pool DE

Tariff Kit. Installatörshandbok Tariff Kit för NIBE F1330 LEK. Installer manual Tariff Kit for NIBE F1330

Installatörshandbok AXC 40. Tillbehör IHB SE

Installatörshandbok AXC 40. Tillbehör IHB SE

ECS 40. Installatörshansbok Extra Klimatsystem för NIBE F1145, F1245. Installer manual Extra climate system for NIBE F1145, F1245

POOL 40. Installatörshandbok pooluppvärmning SE. Installer manual pool heating GB. Installateurhandbuch Poolerwärmung DE IHB LEK

Installatörshandbok AXC 40. Tillbehör IHB SE LEK

SOLAR 40 IHB LEK

SE GB DE FI. Installatörshandbok dockningssats kyla (4-rör) Installer manual docking kit cooling (4-pipe)

PCS 44. Installatörshandbok Passiv kyla för NIBE F1145, F1245. Installer manual Passive cooling for NIBE F1145, F1245

Installatörshandbok AXC 40

SOLAR 40. Installatörshandbok SOLAR 40. Installer manual SOLAR 40. Installateurhandbuch SOLAR 40. Asentajan käsikirja SOLAR 40 NIBE F1145/F1155/SMO 40

SOLAR 40. Installatörshandbok SOLAR 40 SE. Installer manual SOLAR 40 GB. Installateurhandbuch SOLAR 40 DE. Asentajan käsikirja SOLAR 40 FI

SOLAR 41. Installatörshandbok SOLAR 41. Installer manual SOLAR 41. Installateurhandbuch SOLAR 41 IHB LEK

ECS 40/ECS 41. Installatörshandbok Extra Klimatsystem. Installer manual Extra climate system. Installateurhandbuch Extra mischgruppe IHB

Installatörshandbok AXC 40

F1220, F1230, F1120, F1130

SCA 43. Installatörshandbok Dockningssats F730 / AHPS / VPB 300 / VPBS 300 Installer manual Docking kit. Installateurhandbuch Anschlusssatz

LEK EXC 40. Installatörshandbok EXC 40. Installer manual EXC 40. Installateurhandbuch EXC 40. Asentajan käsikirja EXC 40 IHB

ACS 45 SE GB. Installatörshandbok Passiv/aktiv kyla (4-rör) Installer manual Passive/active cooling (4 pipe)

Dockningssats DEW 40 IHB

ACS 45. Installatörshandbok Passiv/aktiv kyla (4-rör) Installer manual Passive/active cooling (4 pipe)

Installatörshandbok OPT 10

SOLAR 41. Installatörshandbok Dockningssats SE. Installer manual Docking kits GB. Installateurhandbuch Anschlussatz DE

POOL 10 MAV POOL 10 SE MONTERINGSANVISNING POOL 10 INSTALLATION INSTRUCTIONS POOL 10 LEK 30 C

Installatörshandbok AXC 50. Tillbehör IHB SE LEK

Installatörshandbok SMO 40

Installatörshandbok Överskåp. Installer manual Top cabinet. Installateurhandbuch Oberschrank. Asentajan kasikirja Yläkaappi IHB SE LEK

Installatörshandbok AXC30. Tillbehör IHBSE

DEH40/41. Installatörshandbok DEH40/41. Installer manual DEH40/41. Installateurhandbuch DEH40/41 IHB LEK

Installatörshandbok AXC 50. Tillbehör IHB SE

CTC Rumsdisplay CTC Roomdisplay Installations- och skötselanvisning. Installation and maintenance instructions

DEH 40/DEH 41. Installatörshandbok. Installer manual. Installateurhandbuch IHB LEK

PCS 44. Installatörshandbok Passiv kyla SE. Installer manual Passive cooling GB. Installateurhandbuch Passive Kühlung DE

MAV POOL 10 POOL 10 MONTERINGSANVISNING POOL 10 INSTALLATION INSTRUCTIONS POOL 10 LEK 30 C

METROSAVER MB F & F-PC

Installatörshandbok Dockningssats för F750 med VPBS 300 samt sol. Installer manual Docking kit for F750 with VPBS 300 and solar

F1220, F1230, F1120, F1130

POOL 40 IHB SE GB DE FI FR. Installatörshandbok pooluppvärmning. Installer manual pool heating. Installateurhandbuch Poolerwärmung

Installatörshandbok AXC 50. Tillbehör IHB SE LEK

POOL 20. CPU-kort MAV SE POOL MONTERINGSANVISNING POOL 20 TILL VVM 240 / 300 INSTALLATION INSTRUCTIONS POOL 20 FOR VVM 240 / 300

MONTERINGSANVISNING POOL 11 TILL FIGHTER 1130/1135/1230/1235/1250 INSTALLATION INSTRUCTIONS POOL 11 FOR FIGHTER 1120/1140/1220/1240/1250

MAV SE POOL MONTERINGSANVISNING POOL 20. CPU-kort. Plåt med kopplingsplint DATASKYLT SERIENR VV KV

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

GOLD SD Med styrenhet/with control unit. Fläkt 1A/B/ Fan 1A/B. Fläkt 2A/B/ Fan 2A/B. Fläkt/ Fan. Utan filter/ Without filter

EXP 12 MAV EXP 12 MONTERINGSANVISNING EXPANSIONSKORT 12 TILL FIGHTER 1320/1330

Anvisning till VD8A för rundpumpning med seriekoppling

GOLD SD Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1. Fläkt 2/ Fan 2. Med filter/ With filter Filter

MODBUS 40 IHB LEK

Anvisning till VDM6A för konstanttryckssystem ANV155

MONTERINGSANVISNING EXTRA SHUNT ESV 28 TILL NIBE SPLIT INSTALLATION INSTRUCTIONS EXTRA SHUNT ESV 28 FOR NIBE SPLIT

THERMOMATIC 125 User and installation instructions

SERVICEINSTRUKTION Värmeproduktion. SERVICE INSTRUCTION Heat production. Wärmeerzeugung SIT SE/GB/DE M10383 FIGHTER 1320

CMR 26/CMR 45. Installatörshandbok. Installer manual. Installateurhandbuch IHB

Installatörshandbok NIBE FJVM 220. Fjärrvärmemodul IHB SE LEK

F1220, F1230, F1120, F1130

CMR 26/CMR 45. Installatörshandbok. Installer manual. Installateurhandbuch IHB

Ersättning styrkort GOLD, stl 1-3, Version 1-3/ Replacement control circuit board GOLD, sizes 1-3, Version 1-3

GOLD SD 100, eff.var./cap.var. 1

METROSAVER MB F & MB F-PC

EMK 300. Installatörshandbok Energimätarkit. Installer manual Energy meter kit. Installateurhandbuch Energimesssatz. Installatørhåndbog Energimålersæt

GOLD SD eff.var./cap.var.120-1

SE/GB.ELSD5060E

MONTERINGSANVISNING EXTRA SHUNT ESV 22 TILL ACVM 270/HBS 12/HBS 16 INSTALLATION INSTRUCTIONS EXTRA SHUNT ESV 22 FOR ACVM 270/HBS 12/HBS 16

MAV SE POOL MONTERINGSANVISNING POOL 20. CPU-kort. Plåt med kopplingsplint DATASKYLT SERIENR VV KV

Dockningsprincip. Tillämpning. Funktion. F1145/F1155 till värmesystem, eventuella tillbehör samt eventuell tillsatsvärme

BAU 10. Installatörshandbok Konsolmontering SE. Installer manual Bracketsassembly GB. Installateurhandbuch Konsolenmontage DE

Discovery FSQ, IAA Utgåva/Edition 11. SE Habo. Klass 2 IAA FSQ-I 26W. 4 mm c c mm N L

GOLD SD Med styrenhet/ With control unit. Fläkt 3/ Fan 3. Fläkt 1/ Fan 1. Fläkt 2/ Fan 2. Fläkt/ Fan. Utan filter/ Without filter

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter

EXP 12 MAV EXP 12 MONTERINGSANVISNING EXPANSIONSKORT 12 TILL F1330 INSTALLATION INSTRUCTIONS EXPANSION CARD 12 FOR F1330

MONTERINGSANVISNING FRIKYLA PK4 TILL FIGHTER 1135/1235

Kommunikationsmodul SMS 40

RE 10 MAV RE 10 MONTERINGSANVISNING RUMSENHET RE 10 TILL FIGHTER 1135/1235/1250/VVM 300/SMO 10

4.2 Konstantes Fördervolumen Doppelpume

SERVICEINSTRUKTION Tider. SERVICE INSTRUCTION Times. Zeiten SIT SE/GB/DE M10401 FIGHTER 2005/2010

Humidity sensor. Fuktgivare/ * F F1:1 F1:1 F2:1 F2:2 * E * E * E * E F1:2 F1:1. Temperature sensor 3. Temperaturgivare 3/ Fläkt/ Fan.

GOLD SD 40/50, eff.var./cap.var. 2

Manual. SE Control Omni Dockningsstation GB Control Omni Docking station DE Control Omni Dockstation

Dockningsprincip. Tillämpning Villor med vattenburet värmesystem. Max rek värmeeffekt 13,5 kw. Alternativ

Assembly instruction Kit 200

Parasol base stand granite Parasollfot granit / Parasollfot granitt / Sonnenschirmfuß Granit / Aurinkovarjon jalka, graniittia

Technical description with installation and maintenance instructions

GOLD SD 100, eff.var./cap.var. 2

GOLD SD 04/05, 07/08, 11 eff.var./cap.var. 1

GOLD SD 100, eff.var./cap.var. 2

GOLD SD Med styrenhet/with control unit. Fläkt 1A/B/ Fan 1A/B. Fläkt 2A/B/ Fan 2A/B. Fläkt/ Fan. Utan filter/ Without filter

SE/GB.ELSD5060E

GOLD SD 60. Med styrenhet/with control unit. Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1.

Metallmaßstäbe RL. Inhaltsverzeichnis

Windlass Control Panel v1.0.1

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

SE/GB.ELSD12D

Med styrenhet (i undre plan)/with control unit (in lower level) Säkerhetsbrytare/ huvudströmbrytare/ Safety switch/ main switch

Transkript:

POO 0 EK SE Installatörshandbok Dockningssats pool G DE Installer manual Docking kit pool Installateurhandbuch nschlusssatz Pool EK FI sentajan käsikirja iitäntäsarja allas DK Installatørhåndbog Sammenkoblingssæt pool IH - 0

Svenska, Installatörshandbok- POO 0 SE llmänt Komponentplacering POO 0 är ett tillbehör för att möjliggöra pooluppvärmning med VVM 0. Inomhusmodulen styr växelventilen(qn) samt cirkulationspumparna(gp) och (GP). Innehåll st Cirkulationspump S F st untband X st Ställdon växelventil st Växelventil EK st pparatlåda st Värmeledningspasta X F X X st st st luminiumtejp Isoleringstejp Temperaturgivare Elkomponenter F utomatsäkring, 0 X nslutningsplint, spänningsmatning Tillbehörskort -X nslutningsplint, givare och extern blockering -X nslutningsplint, kommunikation -X nslutningsplint, cirkulationspump, shunt och hjälprelä -S DIP-switch -F Finsäkring, TH0V eteckningar i komponentplacering enligt standard IEC - och -.

SE Röranslutning llmänt NärVVM0ärdockadmotpoolmåsteladdkretsen förses med en yttre cirkulationspump(gp) då det inte är möjligt att använda den interna laddpumpen (GP) i VVM 0. Den interna cirkulationspumpen (GP) i VVM 0 upprätthåller flödet i klimatsystemet under poolladdning. Växelventil Montera växelventilen(qn) med port som inkommande framledning från värmepumpen, port mot poolen och port mot värmesystemet. Montera den såattportäröppenmotportnärmotornäriviloläge.vidsignalöppnarportmotport. Röranslutningar. Om VVM 0 redan är installerad och vattenfylld så ska klimatsystemet och VVM 0 tömmas på vatten, se installatörshandboken för VVM 0 för ytterligare instruktioner.. Rörtillochfrånpoolenkopplasinmellanvärmepumpen och VVM 0. TIPS! För att undvika onödiga värmeförluster bör rören isoleras. Temperaturgivare Temperaturgivaren för pool(t) placeras på returledningen från poolen. Temperaturgivaren monteras med buntband tillsammans med värmeledningspasta och aluminiumtejp. Därefter ska den isoleras med medföljande isolertejp. OS! Givar- och kommunikationskablar får ej förläggas i närheten av starkströmsledning.

SE Systemprincip Förklaring C Poolsystem E VVM 0 pparatlåda X nslutning, dockning pool T Temperaturgivare, pool E0 F0/F00/F00 EP Värmeväxlare, pool Övrigt GP Cirkulationspump, pool CM Expansionskärl GP Cirkulationspump, kylning F Säkerhetsventil, klimatsystem HQ Smutsfilter QN Växelventil, pool eteckningar enligt standard IEC -. Dockning till pool Uppvärmning av poolen prioriteras enligt valda inställningar i inomhusmodulen. Om poolgivaren(t) inte är ansluten tillåts poolladdningen inte att starta. Principschema -C -EP -GP -T -HQ - -C -GP -F -CM -C-QN -E -E0 -E0 -F0 -RN0 -QM0 X -HQ-QM X -QM OS! Detta är ett principschema. Verklig anläggning skall projekteras enligt gällande normer.

VVM 0 0 0 0 0 N N SE Elinkoppling OS! ll elektrisk inkoppling skall ske av behörig elektriker. Elektrisk installation och ledningsdragning skall utföras enligt gällande bestämmelser. Inomhusmodulen ska vara spänningslös vid installation av POO 0. nslutning av matning nslut spänningsmatningen till plint X enligt bild. -X 0V 0Hz N Elschema finns i slutet av denna installatörshandbok. nslutning av kommunikation Detta tillbehör innehåller ett tillbehörskort() som ska anslutas direkt till inomhusmodulen på ingångskortet(plint -X). Om flera tillbehör ska anslutas eller redan finns installerade måste nedanstående instruktion följas. Det första tillbehörskortet ska anslutas direkt till inomhusmodulens plint -X. De efterföljande korten ansluts i serie med föregående kort. nvänd kabeltyp iyy, EKKX eller likvärdig. -X -X -X -X -X -X0 -X -X -X -X -X -X -X0 -X -X

SE -X -X 0 0 -X nslutning av givare och extern blockering nvänd kabeltyp iyy, EKKX eller likvärdig. Poolgivare (T) nslut poolgivaren till -X:-. Extern blockering (valfritt) En kontakt kan anslutas till -X:- för att kunna blockera pooluppvärmningen. När kontakten sluts blockeras pooluppvärmningen. T Extern blockering -X0 -X N -X nslutning av cirkulationspump(gp) nslut cirkulationspumpen(gp) till -X:(0 V), -X:(N) och X:(). -X Externt X GP nslutning av växelventilsmotor(qn) och cirkulationspump, kylning(gp) nslut växelventilens motor(qn) och cirkulationspumpen(gp) till en extern kopplingsbox. nslut svart ledare från växelventilen samt brun ledare från cirkulationspumpen tillsammans i kopplingsboxen. nslut blå ledare från växelventilen samt blå ledare från cirkulationspumpen tillsammans i kopplingsboxen. nslut styrande kabel från kopplingsboxen till - X:(signal), -X:(N), -X0:(0 V) och X:. nslut cirkulationspumpens styrsignal till - X:-. 0 TÄNK PÅ! -X Reläutgångarna på tillbehörskortet får max belastasmed(0v)totalt.

SE DIP-switch DIP-switchen på tillbehörskortet ska ställas in enligt nedan. ktivering av POO 0 Programinställningen av POO 0 kan göras via startguiden eller direkt i menysystemet. -S Startguiden Startguiden visas vid första uppstart efter värmepumpsinstallationen, men finns även i meny.. Menysystemet Om du inte gör alla inställningar via startguiden eller behöver ändra någon inställning kan du göra detta i menysystemet. Meny. - systeminställningar ktivering/avaktivering av tillbehör. Meny.. - pool ktivering av pooluppvärmning samt inställning av start- och stopptemperatur. Meny.. - värmebärarpumpshastighet Inställning av värmebärarpumpens hastighet. TÄNK PÅ! Se även Installatörshandboken för VVM 0.

English, Installer manual- POO 0 G General Component positions POO 0 is an accessory that enables pool heating with VVM 0. The indoor module controls the reversing valve(qn) and circulation pumps(gp and GP). Contents x x Circulation pump Cable ties S X F x ctuator reversing valve x Shuttle valve EK x Unit box x Heating pipe paste X F X X x x x luminium tape Insulation tape Temperature sensor Electrical components F Miniature circuit-breaker. 0 X Terminal block, power supply ccessory card -X Terminal block, sensors and external blocking -X Terminal block, communication -X Terminal block, circulation pump, mixing valve and auxiliary relay -S DIP switch -F Fine wire fuse, TH0V Designations in component locations according to standard IEC - and -.

G Pipe connections General WhenVVM0isdockedtopool,thechargecircuit must be supplied with an external circulation pump (GP)asitisnotpossibletousetheinternalcharge pump(gp) in VVM 0. The internal circulation pump(gp)invvm0maintainstheflowintheclimate system during pool charging. Shuttle valve Install the reversing valve(qn) with port as incomingflowlinefromtheheatpump,porttowardsthe poolandporttowardstheheatingsystem.installit sothatportisopentowardsportwhenthemotor isinstandbymode.intheeventofasignalport opens towards port. Pipe connections. IfVVM0hasalreadybeeninstalledandfilled withwater,theclimatesystemandvvm0must be drained of water, see Installer manual for VVM 0 for further instructions.. Pipestoandfromthepoolareconnectedbetween theheatpumpandvvm0. TIP To prevent unnecessary heat losses insulate the pipes. Temperature sensor The pool temperature sensor(t) is located on the return line from the pool. Install the temperature sensor with cable ties with the heat conducting paste and aluminium tape. Then insulate with supplied insulation tape. NOTE Sensor and communication cables must not be placed near power cables. 0

G System diagram Explanation C Pool system E VVM 0 Unit box X Connection, docking pool T Temperature sensor, pool E0 F0/F00/F00 EP Heat exchanger, pool Miscellaneous GP Circulation pump, pool CM Expansion vessel GP Circulation pump, cooling F Safety valve, climate system HQ Particle filter QN Three way valve, pool Designations according to standard IEC -. Docking to pool Heatingofthepoolisprioritisedaccordingtoselectedsettingsintheindoormodule.Ifthepoolsensor(T)isnot connected, pool charging is not permitted to start. Outline diagram -C -EP -GP -T -HQ - -C -GP -F -CM -C-QN -E -E0 -E0 -F0 -RN0 -QM0 X -HQ-QM X -QM Note! This is an outline diagram. ctual installations must be planned according to applicable standards.

VVM 0 0 0 0 0 N N G Electrical connection NOTE ll electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. The indoor module must not be powered when installing POO 0. -X TheelectricalcircuitdiagramisattheendofthisInstaller handbook. Connecting communication This accessory contains an accessory card() that must be connected directly to the indoor module on the input card(terminal block -X). -X -X -X -X -X0 -X -X If several accessories are to be connected or are already installed, the following instructions must be followed. The first accessory card must be connected directly to the indoor module's terminal block -X. The following cards must be connected in series with the previous card. Use cable type iyy, EKKX or similar. -X -X -X -X -X0 -X -X Connecting the supply Connect the power supply to terminal block X as illustrated. -X 0V 0Hz N

G -X -X 0 0 -X Connection of sensors and external blocking Use cable type iyy, EKKX or similar. Pool sensor (T) Connect the pool sensor to -X:-. External blocking (optional) contact(no) can be connected to -X:- to block pool heating. When the contact closes, pool heating is blocked. T External blocking -X0 -X N -X Connection of the circulation pump(gp) Connect the circulation pump(gp) to -X:(0 V), -X:(N) and X:(). -X External X GP Connection of reversing valve motor(qn) and circulation pump, cooling(gp) Connect the reversing valve motor(qn) and circulation pump(gp) to an external junction box. Connect black cable from the reversing valve and brown cable from the circulation pump together in the junction box. Connect blue cable from the reversing valve and blue cable from the circulation pump together in the junction box. Connect the control cable from the junction box to -X:(signal), -X:(N), -X0:(0 V) and X:. Connect the circulation pump control signal to -X:-. Caution 0 -X The relay outputs on the accessory card can haveamaxloadof(0v)intotal.

G DIP switch TheDIPswitchontheaccessorycardmustbesetas follows. ctivating POO 0 ProgramsettingofPOO0canbeperformedviathe start guide or directly in the menu system. -S Start guide The start guide appears upon first start-up after heat pump installation, but is also found in menu.. Menu system Ifyoudonotmakeallsettingsviathestartguideor needtochangeanyofthesettings,thiscanbedone in the menu system. Menu. - system settings ctivating/deactivating of accessories. Menu.. - pool ctivating pool heating and setting start and stop temperature. Menu.. - pump speed heating medium Setting heating medium pump's speed. Caution lsoseetheinstallermanualforvvm0.

Deutsch, Installateurhandbuch- POO 0 DE llgemeines Position der Komponenten Das Zubehör POO 0 ermöglicht die Poolerwärmung mit VVM 0. Das Innenmodul regelt das Umschaltventil(QN) sowie die Umwälzpumpen(GP) und(gp). Inhalt St. Umwälzpumpe S F St. Kabelbinder X St. Stellantrieb Umschaltventil St. Wechselventil St. Gerätegehäuse EK St. Wärmeleitpaste St. luminiumklebeband X F X X St. St. Isolierband Fühler Elektrische Komponenten F Sicherungsautomat, 0 X nschlussklemme, Spannungsversorgung Zubehörplatine -X nschlussklemme für Fühler und extern geschaltete lockierung -X nschlussklemme für Kommunikationsleitung -X nschlussklemme für Umwälzpumpe, Mischventil und Hilfsrelais -S DIP-Schalter -F Feinsicherung, TH0V ezeichnungen der Komponentenpositionen gemäß Standard IEC - und -.

DE Rohranschluss/Durchflussmesser llgemeines WennVVM0miteinemPoolverbundenist,muss der adekreis mit einer externen Umwälzpumpe(GP) bestückt werden, da die interne adepumpe(gp) in VVM 0 nicht genutzt werden kann. Die interne Umwälzpumpe(GP) in VVM 0 hält während der Poolerwärmung den Volumenstrom im Klimatisierungssystem aufrecht. Wechselventil Montieren Sie das Umschaltventil(QN) mit nschluss als Vorlaufzufluss von der Wärmepumpe, nschluss zum Pool und nschluss zum Heizsystem. ringen SiedasVentilsoan,dassnschlusszunschluss geöffnet ist, wenn sich der Motor im Ruhezustand befindet. ei einem Signal öffnet sich nschluss zu nschluss. Rohranschlüsse. Wenn VVM 0 bereits installiert und mit Wasser befüllt wurde, muss das Wasser aus dem Klimatisierungssystem und VVM 0 entleert werden. Weitere nweisungen entnehmen Sie dem Installateurhandbuch für VVM 0.. DerPoolwirdüberRohrleitungenmitVVM0 verbunden. TIP! Um unnötige Wärmeverluste zu vermeiden, sollten die Rohre isoliert werden. Fühler DerFühlerfürdenPool(T)wirdamRücklaufvom Pool befestigt. Der Fühler wird mit Kabelbinder, Wärmeleitpaste und luminiumklebeband angebracht. nschließend ist er mit dem beiliegenden Isolierband zu umwickeln. HINWEIS! Fühler- und Kommunikationskabel dürfen nicht in der Nähe von Starkstromleitungen verlegt werden.

DE Systemprinzip Erklärung C Poolsystem E VVM 0 Gerätegehäuse X nschluss, Dockung Pool T Fühler, Pool E0 F0/F00/F00 EP Trennwärmetauscher, Pool Sonstiges GP Umwälzpumpe, Pool CM usdehnungsgefäß GP Umwälzpumpe, Kühlung F Sicherheitsventil, Klimatisierungssystem HQ Schmutzfilter QN Wechselventil, Pool ezeichnungen gemäß Standard IEC -. nschluss an Pool Der Poolerwärmung wird gemäß den gewählten Einstellungen im Innenmodul Vorrang eingeräumt. Wenn der Poolfühler(T) nicht angeschlossen ist, kann die Poolerwärmung nicht gestartet werden. Prinzipskizze -C -EP -GP -T -HQ - -C -GP -F -CM -C-QN -E -E0 -E0 -F0 -RN0 -QM0 X -HQ-QM X -QM Hinweis: Dies ist eine Prinzipskizze. Die tatsächliche nlage muss gemäß den geltenden Normen geplant und montiert werden.

VVM 0 0 0 0 0 N N DE Elektrischer nschluss HINWEIS! lle elektrischen nschlüsse müssen von einem geprüften Elektriker ausgeführt werden. ei der Elektroinstallation und beim Verlegen der eitungen sind die geltenden Vorschriften zu berücksichtigen. Das Innenmodul darf bei der Installation von POO 0 nicht mit Spannung versorgt werden. Der Schaltplan befindet sich am Ende dieses Installateurhandbuchs. nschluss der Kommunikationsleitung Dieses Zubehör umfasst eine Zubehörplatine(), die direkt über die Eingangsplatine(nschlussklemme -X) mit dem Innenmodul zu verbinden ist. Sollen mehrere Zubehöreinheiten angeschlossen werden oder sind bereits Zubehöreinheiten installiert, ist die folgende nweisung zu befolgen. Die erste Zubehörplatine ist direkt mit der nschlussklemme -X des Innenmoduls zu verbinden. Die nächste Platine muss mit der vorherigen in Reihe geschaltet werden. Verwenden Sie Kabeltyp iyy, EKKX oder gleichwertig. -X -X -X -X -X -X -X -X -X nschluss der Spannungsversorgung Verbinden Sie die Spannungsversorgung mit Klemme X, siehe bbildung. -X0 -X -X0 -X -X -X -X 0V 0Hz N

DE -X -X 0 0 -X nschluss von Fühler und extern geschalteter Sperrung Verwenden Sie Kabeltyp iyy, EKKX oder gleichwertig. -X0 -X N -X nschluss der Umwälzpumpe(GP) Verbinden Sie die Umwälzpumpe(GP) mit -X: (0V),-X:(N)undX:(). -X X Extern GP Poolfühler (T) Verbinden Sie den Poolfühler mit -X:-. Extern geschaltete Sperrung (beliebig) Ein Kontakt kann mit -X:- verbunden werden, um die Poolerwärmung zu blockieren. eim Schließen des Kontakts wird die Poolerwärmung blockiert. Extern geschaltete lockierung T nschluss des Umschaltventilmotors(QN) und Umwälzpumpe, Kühlung(GP) nschluss des Umschaltventilmotors(QN) und Umwälzpumpe(GP) an eine externe nschlusseinheit. Verbinden Sie den schwarzen eiter des Umschaltventils sowie den braunen eiter von der Umwälzpumpe zusammen in der nschlusseinheit. Verbinden Sie den blauen eiter vom Umschaltventil sowie den blauen eiter von der Umwälzpumpe zusammen in der nschlusseinheit. Verbinden Sie das Steuerkabel der nschlusseinheit mit -X:(Signal), -X:(N), -X0:(0 V) und X:. Verbinden Sie das Steuersignal der Umwälzpumpe mit -X:-. 0 CHTUNG! -X Die Relaisausgänge an der Zusatzplatine dürfeninsgesamtmitmaximal(0v)belastet werden.

DE DIP-Schalter Der DIP-Schalter an der Zusatzplatine ist wie folgt einzustellen. -S ktivierung von POO 0 Die Programmeinstellung von POO 0 kann per Startassistent oder direkt im Menüsystem vorgenommen werden. Startassistent Der Startassistent erscheint bei der ersten Inbetriebnahme nach der Wärmepumpeninstallation. Er kann ebenfalls über Menü. aufgerufen werden. Menüsystem Wenn Sie nicht alle Einstellungen über den Startassistent vornehmen oder eine Einstellung ändern wollen, können Sie das Menüsystem nutzen. Menü. - Systemeinst. ktivierung/deaktivierung von Zubehör. Menü.. - Pool ktivierung der Poolerwärmung sowie Einstellung der Start- und Stopptemperatur. Menü.. - Pumpengeschw. Wärmetr. Einstellung der Geschwindigkeit für die Heizkreispumpe. CHTUNG! Siehe auch Handbuch für Installateure für VVM 0. 0

Suomi, sentajan käsikirja- POO 0 FI Yleistä Komponenttien sijainti POO 0 on lisävaruste, joka mahdollistaa allasveden lämmityksen VVM 0:lla. Sisäyksikkö ohjaa vaihtoventtiiliä(qn) ja kiertovesipumppuja(gp) ja(gp). Sisältö kpl Kiertovesipumppu S F kpl Nippuside X kpl Toimilaite, vaihtoventtiili kpl Vaihtoventtiili kpl Kojerasia EK kpl ämmönjohtotahna kpl lumiiniteippi X F X X kpl kpl Eristysteippi ämpötila-anturi Sähkökomponentit F utomaattivaroke, 0 X iitinrima, jännitteensyöttö isävarustekortti -X iitinrima, anturi ja ulkoinen esto -X iitinrima, tiedonsiirto -X iitinrima, kiertovesipumppu, shuntti ja apurele -S DIP-kytkin -F Pienjännitevaroke, TH0V Komponenttikaavion merkinnät standardin IEC - ja - mukaan.

FI Putkiliitäntä Yleistä Kun VVM 0 on liitetty altaaseen, latauspiiriin on asennettava ulkoinen kiertovesipumppu(gp), koska VVM 0:n sisäistä latauspumppua(gp) ei voi käyttää. VVM 0:n sisäinen kiertovesipumppu(gp) pitää yllä virtauksen lämmitysjärjestelmässä altaan lämmityksen aikana. Vaihtoventtiili senna vaihtoventtiili(qn) periaatekaavion mukaisesti: liitäntä lämpöpumppuun, liitäntä altaaseen ja liitäntä lämmitysjärjestelmään. senna se niin, että liitäntä on auki liitännän suuntaan, kun moottori on lepoasennossa. Signaali avaa liitännän ja liitännän yhteyden. Putkiliitännät. JosVVM0onjoasennettujatäytettyvedellä, lämmitysjärjestelmä ja VVM 0 pitää tyhjentää vedestä, katso lisäohjeet VVM 0:n asennusohjeesta.. ltaan meno- ja paluuputket liitetään lämpöpumpun ja VVM 0-sisäyksikön välille. VIHJE! Tarpeettomien lämpöhäviöiden välttämiseksi putket tulee eristää. ämpötila-anturi ltaan lämpötila-anturi(t) asennetaan altaan paluujohtoon. ämpötila-anturi asennetaan nippusiteillä lämmönjohtotahnan ja alumiiniteipin kanssa. Sen jälkeen se eristetään mukana toimitetulla eristysteipillä. HUOM! nturi- ja tiedonsiirtokaapeleita ei saa vetää vahvavirtajohtojen läheisyydessä.

FI Järjestelmäperiaate Selvitys C llasjärjestelmä E VVM 0 Kojerasia X iitäntä, allas T ämpötila-anturi, allas E0 F0/F00/F00 EP ämmönsiirrin, allas Muuta GP Kiertopumppu, allas CM Kalvopaisuntasäiliö GP Kiertovesipumppu, jäähdytys F Varoventtiili, lämmitysjärjestelmä HQ Mudanerotin QN Vaihtoventtiili, allas Merkinnät standardin IEC - mukaan. iitäntä altaaseen ltaan lämmitys priorisoidaan sisäyksikön asetusten mukaisesti. Ellei allasanturia(t) ole kytketty, altaan lämmitystä ei sallita. Periaatekaavio -C -EP -GP -T -HQ - -C -GP -F -CM -C-QN -E -E0 -E0 -F0 -RN0 -QM0 X -HQ-QM X -QM HUOM! Tämä on periaatekaavio. Todellinen laitteisto on suunniteltava voimassaolevien määräysten ja standardien mukaisesti.

VVM 0 0 0 0 0 N N FI Sähköasennukset HUOM! Sähköasennukset saa tehdä vain valtuutettu sähköasentaja. Sähköasennukset ja johtimien veto on tehtävä voimassa olevien määräysten mukaisesti. Sisäyksikön pitää olla jännitteetön POO 0:n asennuksen aikana. Syöttöjännitteen kytkeminen Kytke jännitteensyöttö liittimeen X kuvan mukaisesti. -X 0V 0Hz N Kytkentäkaavio on tämän asennusohjeen lopussa. Tiedonsiirron kytkentä Tämä lisävaruste sisältää lisävarustekortin(), joka kytketään suoraan sisäyksikön tulokorttiin(liitin - X). Jos olet kytkemässä useita lisävarusteita tai niitä on jo asennettu, sinun täytyy noudattaa alla olevia ohjeita. Ensimmäinen lisävarustekortti asennetaan suoraan sisäyksikön liittimeen -X. Seuraavat kortit asennetaan sarjaan edellisen kanssa. Käytä kaapelia iyy, EKKX tai vastaava. -X -X -X -X -X -X0 -X -X -X -X -X -X -X0 -X -X

FI -X -X 0 0 -X nturien ja ulkoisen eston kytkeminen Käytä kaapelia iyy, EKKX tai vastaava. llasanturi (T) Kytke allasanturi liittimeen -X:-. Ulkoinen esto (valinnainen) Yksi kosketin voidaan kytkeä liittimeen -X:- altaan lämmityksen estoa varten. ltaan lämmitys on estetty kun kosketin suljetaan. T Ulkoinen esto -X0 -X N -X Kiertovesipumpun kytkentä(gp) Kytke kiertovesipumppu(gp) liittimiin -X:(0 V),-X:(N)jaX:(). -X Ulkoinen X GP Vaihtoventtiilimoottorin(QN) ja jäähdytyksen kiertovesipumpun(gp) liitäntä Kytke vaihtoventtiilin moottori(qn) ja kiertovesipumppu(gp) ulkoiseen kytkentärasiaan. Kytke musta johdin vaihtoventtiililtä ja ruskea johdin kiertovesipumpulta kytkentärasiaan. Kytke sininen johdin vaihtoventtiililtä ja sininen johdin kiertovesimpumpulta kytkentärasiaan. Kytke ohjauskaapeli kytkentärasiasta liittimeen - X:(signaali), -X:(N), -X0:(0 V) ja X:. Kytke kiertovesipumpun ohjaussignaali liittimeen -X:-. 0 MUIST! -X isävarustekortin relelähtöjen suurin sallittu kokonaiskuormitus on (0 V).

FI DIP-kytkin isävarustekortin DIP-kytkimet pitää asettaa alla olevan mukaan. POO 0:n aktivointi POO 0:n asetukset voidaan tehdä aloitusoppaassa tai suoraan valikkojärjestelmässä. -S loitusopas loitusopas näytetään ensimmäisen käynnistyksen yhteydessä lämpöpumpun asennuksen jälkeen, mutta se löytyy myös valikosta.. Valikkojärjestelmä Ellet tee kaikkia asetuksia aloitusoppaan kautta tai haluat muuttaa jotain asetusta, voit tehdä sen valikkojärjestelmässä. Valikko. - järjestelmäasetukset isävarusteiden aktivointi/deaktivointi. Valikko.. - allas ltaan lämmityksen aktivointi ja käynnistys- ja pysäytyslämpötilojen asettaminen. Valikko.. - kiertovesipumpun nopeus ämpöjohtopumpun nopeuden asettaminen. MUIST! Katso myös VVM 0:n asentajan käsikirja.

Dansk, Installatørhåndbog- POO 0 DK Generelt Komponentplacering POO 0 er et tilbehør, der muliggør poolopvarmning med VVM 0. Indendørsmodulet styrer omskifterventilen(qn) samt cirkulationspumperne(gp) og (GP). Indhold stk. Cirkulationspumpe S F stk. Kabelbindere X stk. ktuator omskifterventil stk. Omskifterventil EK stk. Styreboks stk. Varmeledningspasta X F X X stk. stk. stk. luminiumtape Isoleringsbånd Temperaturføler Elektriske komponenter F utomatsikring, 0 X Klemme, spændingsforsyning Tilbehørskort -X Klemme, føler og ekstern blokering -X Klemme, kommunikation -X Klemme, cirkulationspumpe, shunt og hjælperelæ -S DIP-switch -F Finsikring, TH0V etegnelser i komponentplacering iht. standard IEC - og -.

DK Rørtilkobling Generelt NårVVM0erkobletmodpool,skalladekredsen udstyres med en ekstern cirkulationspumpe(gp), da det ikke er muligt at benytte den interne ladepumpe (GP) i VVM 0. Den interne cirkulationspumpe(gp) i VVM 0 opretholder flowet i varmeanlægget under poolopvarmning. Omskifterventil Monter omskifterventilen(qn) med port som indkommende fremløb fra varmepumpen, port mod poolen og port mod varmesystemet. Monter den således,atporteråbenmodport,nårmotoreneri hvileposition. Ved signal åbner port mod port. Rørtilslutninger. HvisVVM0alleredeerinstalleretogfyldtmed vand, skal varmeanlægget og VVM 0 tømmes for vand, se installatørhåndbogen til VVM 0 for yderligere instrukser.. RørtilogfrapoolenkoblesindmellemvarmepumpenogVVM0. TIP! For at undgå unødige varmetab bør rørene isoleres. Temperaturføler Temperaturføleren for pool(t) placeres på returløbet fra poolen. Temperaturføleren monteres med kabelbindere sammen med varmeledningspasta og aluminiumstape. Derefter skal den isoleres med den medfølgende isoleringstape. EMÆRK Føler- og kommunikationskabler må ikke lægges i nærheden af stærkstrømsledninger.

DK Systemprincip Forklaring C Poolsystem E VVM 0 Styreboks X Tilslutning, sammenkobling pool T Temperaturføler, pool E0 F0/F00/F00 EP Varmeveksler, pool ndet GP Cirkulationspumpe, pool CM Ekspansionsbeholder GP Cirkulationspumpe, køling F Sikkerhedsventil, klimaanlæg HQ Snavsfilter QN Omskifterventil, pool etegnelser i henhold til standard IEC -. Sammenkobling til pool Opvarmning af poolen prioriteres i henhold til valgte indstillinger i indendørsmodulet. Hvis poolføleren(t) ikke er tilsluttet, får poolladningen ikke lov til at starte. Principskitse -C -EP -GP -T -HQ - -C -GP -F -CM -C-QN -E -E0 -E0 -F0 -RN0 -QM0 X -HQ-QM X -QM OS! Dette er principskemaer. Det aktuelle anlæg skal projekteres i henhold til gældende normer.

VVM 0 0 0 0 0 N N DK El-tilslutning EMÆRK lle elektriske tilslutninger skal foretages af en autoriseret elektriker. El-installation og trækning af ledninger skal udføres iht. gældende regler. Indendørsmodulet skal være spændingsløst ved installation af POO 0. -X El-diagram findes i slutningen af denne installatørhåndbog. Tilslutning af kommunikation Dette tilbehør indeholder et tilbehørskort(), som skal tilsluttes direkte til indendørsmodulet på indgangskortet(klemme -X). -X -X -X -X -X0 -X -X Hvis der skal tilsluttes andet tilbehør, eller der allerede er installeret tilbehør, skal nedenstående instrukser følges. Det første tilbehørskort skal tilsluttes direkte til indendørsmodulets klemme -X. De efterfølgende kort tilsluttes i serie med foregående kort. enyt kabeltype iyy, EKKX eller tilsvarende. -X -X -X -X -X0 -X -X Tilslutning af strømforsyning Tilslut strømforsyningen til klemme X som vist på billedet. -X 0V 0Hz N 0

DK -X -X 0 0 -X Tilslutning af føler og ekstern blokering enyt kabeltype iyy, EKKX eller tilsvarende. Poolføler (T) Tilslut poolføleren til -X:-. Ekstern blokering (valgfri) Der kan tilsluttes en kontakt til -X:- for at kunne blokere poolopvarmningen. Når kontakten sluttes, blokeres poolopvarmningen. T Ekstern blokering -X0 -X N -X Tilslutning af cirkulationspumpe(gp) Tilslut cirkulationspumpen(gp) til -X:(0 V), -X:(N) og X:(). -X Eksternt X GP Tilslutning af omskifterventilmotor(qn) og cirkulationspumpe, køling(gp) Tilslut omskifterventilens motor(qn) og cirkulationspumpen(gp) til en ekstern koblingsboks. Tilslut sort leder fra omskifterventilen og brun leder fra cirkulationspumpen sammen i forbindelsesdåsen. Tilslut blå leder fra omskifterventilen og blå leder fra cirkulationspumpen sammen i forbindelsesdåsen. Tilslut styrende kabel fra forbindelsesdåsen til - X:(signal), -X:(N), -X0:(0 V) og X:. Tilslut cirkulationspumpens styresignal til - X:-. 0 HUSK! -X Relæudgangene på tilbehørskortet må maks. belastesmed()(0v)ialt.

DK DIP-switch DIP-switchen på tilbehørskortet skal indstilles i henhold til nedenstående. ktivering af POO 0 Programindstillingen af POO 0 kan foretages via startguiden eller direkte i menusystemet. -S Startguiden Startguiden vises ved første opstart efter varmepumpeinstallationen, men findes også i menu.. Menusystemet Hvis du ikke foretager alle indstillinger via startguiden ellerharbehovforatændreenindstilling,kandugøre dette via menusystemet. Menu. - systemindstillinger ktivering/deaktivering af tilbehør. Menu.. - pool ktivering af poolopvarmning samt indstilling af startog stoptemperatur. Menu.. - varmebærerpumpehastighed Indstilling af varmebærerpumpens hastighed. HUSK! Se også installatørhåndbogen for VVM 0.

Elschema/Wiring diagram/elektrischer schaltplan/ Sähkökytkentäkaavio/El-diagram

DK