Odour measurements in a kitchen exhaust duct at Burger King



Relevanta dokument
Utredning av lukt i omgivningen vid detaljplan Träslöv 30:1 i Varberg

Luktutredning - Biogasanläggning för befintlig fiskeindustri, Kungshamn, Sotenäs kommun

BT Kemi efterbehandling Skede: Förberedelser. Luktundersökning nov Delrapport över utförda luftundersökningar

NORDIC GRID DISTURBANCE STATISTICS 2012

SWETHRO. Gunilla Pihl Karlsson, Per Erik Karlsson, Sofie Hellsten & Cecilia Akselsson* IVL Svenska Miljöinstitutet *Lunds Universitet

Technique and expression 3: weave. 3.5 hp. Ladokcode: AX1 TE1 The exam is given to: Exchange Textile Design and Textile design 2.

SVENSK STANDARD SS

Provtagning i vatten. Jens Fölster Inst. För vatten och miljö, SLU

D6.7 Press book Documentation of media coverings. Sweden

Lisebergs och Örby Slott Villaförening: val av solcellsleverantör

Analys och bedömning av företag och förvaltning. Omtentamen. Ladokkod: SAN023. Tentamen ges för: Namn: (Ifylles av student.

MILJÖLABORATORIET RAPPORT 1 (6)

Basis for Environmental Product Declaration Smart Development Sweden

E4 Sundsvall Sundsvallsbron

Beijer Electronics AB 2000, MA00336A,

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

MÄTNING AV VÄGT REDUKTIONSTAL MEASUREMENT OF THE WEIGHTED SOUND TRANSMISSION LOSS

Collaborative Product Development:

Bilaga 5 till rapport 1 (5)

PM Absorptionsmätningar DOMO


Fiat » Fiat Panda / 4x4 2003» Fiat Panda 4x4 Climbing / 4x4 Cross 20033»

Aborter i Sverige 2008 januari juni

GOLD SD Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1. Fläkt 2/ Fan 2. Med filter/ With filter Filter

Viktig information för transmittrar med option /A1 Gold-Plated Diaphragm

Transformator konferens Stavanger /4 Sammanställning av kunskapsläget I Vattenfall och utvecklingen I Sverige

Quarterly report on measurements of radionuclides in ground level air in Sweden

SVENSK STANDARD SS-EN ISO 11734

MILJÖBEDÖMNING AV BOSTÄDER Kvarteret Nornan, Glumslöv

Isometries of the plane

COPENHAGEN Environmentally Committed Accountants

SWESIAQ Swedish Chapter of International Society of Indoor Air Quality and Climate

Vägytans tillstånd, historik och framtid. Johan Lang

PORTSECURITY IN SÖLVESBORG

Country report: Sweden

Kemi i inomhusluft: När luftföroreningar utifrån och inifrån möts. Sarka Langer

Certifikat. Detta certifikat intygar att. Moelven Årjäng Såg AB

SVENSK STANDARD SS-EN ISO :2011/AC:2013

Documentation SN 3102

CUSTOMER READERSHIP HARRODS MAGAZINE CUSTOMER OVERVIEW. 63% of Harrods Magazine readers are mostly interested in reading about beauty

1. Unpack content of zip-file to temporary folder and double click Setup

SVENSK STANDARD SS-EN ISO

FÖRBERED UNDERLAG FÖR BEDÖMNING SÅ HÄR

Matthew Thurley Industriell bildanalys (E0005E) Response rate = 65 %

This exam consists of four problems. The maximum sum of points is 20. The marks 3, 4 and 5 require a minimum

Boiler with heatpump / Värmepumpsberedare

Kravnivåer i samband med laboratorietestning av filter Kravnivåer i samband med långtidsprov av filter Redovisning av data för P-märkt luftfilter

Measuring child participation in immunization registries: two national surveys, 2001

Kursplan. AB1029 Introduktion till Professionell kommunikation - mer än bara samtal. 7,5 högskolepoäng, Grundnivå 1

Mätningar. Uppdragsnr: Abstracta AB Elin Nork. Göteborg

SVENSK STANDARD SS-ISO 8756

SVENSK STANDARD SS

Inkvarteringsstatistik. Göteborg & Co. Februari 2012

SVENSK STANDARD SS-EN ISO 19108:2005/AC:2015

Uttagning för D21E och H21E

RAPPORT. Besluts PM, Simsholmen Skola Skeppsbron SÖDRA MUNKSJÖN UTVECKLINGS AB JÖNKÖPING. Mats Kall, Leif Axenhamn, Håkan Asmoarp

GERDA Cryostat Rn emanation

SOLAR LIGHT SOLUTION. Giving you the advantages of sunshine. Ningbo Green Light Energy Technology Co., Ltd.

Momento Silverline. To further protect the environment Momento introduces a new coating for our impact sockets - Momento Silverline

Kompletterande luktstudie. 1 Inledning. 2 Bakgrund. 3 Lukt PM 1 (10) 3.1 Allmänt Klicka här för att ange text. Handläggare Sten-Åke Barr

Isolda Purchase - EDI

Komponenter Removed Serviceable

8 < x 1 + x 2 x 3 = 1, x 1 +2x 2 + x 4 = 0, x 1 +2x 3 + x 4 = 2. x 1 2x 12 1A är inverterbar, och bestäm i så fall dess invers.

Kurskod: TAIU06 MATEMATISK STATISTIK Provkod: TENA 15 August 2016, 8:00-12:00. English Version

SVENSK STANDARD SS-ISO 965/2 Första giltighetsdag Utgåva Sida Registrering

Styrteknik: Binära tal, talsystem och koder D3:1

Luftkvalitetsmätningar på Åland

Content of presentation. Long-term effects, maintenance and costs for wastewater treatment wetlands in Sweden. Alhagen - Nynäshamn

ISO general purpose screw threads Basic profile Part 1: Metric screw threads

SVENSK STANDARD SS-ISO :2010/Amd 1:2010

Beslut om ackreditering (3 st bilagor)

SUZUKI GRAND VITARA 3P CITY 2011»

SEKUNDERNA - THE SECONDS, FILM/PROJECT

Västra Götalandsregionens Miljömedicinska Centrum

The Municipality of Ystad

ISO general purpose metric screw threads Selected sizes for screws, bolts and nuts

P650 - Takscreen. Installationsguide EN

Skill-mix innovation in the Netherlands. dr. Marieke Kroezen Erasmus University Medical Centre, the Netherlands

SVENSK STANDARD SS-EN ISO

balans Serie 7 - The best working position is to be balanced - in the centre of your own gravity! balans 7,45

EXPEDITIONSRAPPORT FRÅN U/F ARGOS CRUISE REPORT FROM R/V ARGOS

WAVES4POWER Fosnavåg 24 oktober 2016

Anders Persson Philosophy of Science (FOR001F) Response rate = 0 % Survey Results. Relative Frequencies of answers Std. Dev.

Eternal Employment Financial Feasibility Study

DVU-HP. Integrerat reversibelt värmepumpsystem

INSPECTION PROTOCOL Company copy

Hur påverkas inomhusluftens föroreningsinnehåll av uteluftens kvalitet? Ventilation och filtrering

EASA FTL (Flygarbetstid)

PCB i Oxundaåns vattensystem 2017

MCP-16RC, Air Purification

Dokumentnamn Order and safety regulations for Hässleholms Kretsloppscenter. Godkänd/ansvarig Gunilla Holmberg. Kretsloppscenter

P Äspö Hard Rock Laboratory. Ground magnetic survey at site for planned facility for calibration of borehole orientation equipment at Äspö

Utredning angående havssaltsandelen av PM 10 på bakgrundsstationen Råö

2.1 Installation of driver using Internet Installation of driver from disk... 3

Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

TN LR TT mg/l N b) 2,6-Dimethylphenole

Förhandsvisning av en rapport som är i korrektur, planerad utgivning vid midsommar

Transkript:

REPORT Odour measurements in a kitchen exhaust duct at Burger King For Interzon AB 24 February 2011 Archive number: U 3117 Kjell Peterson Rapporten godkänd 2011-02-24 Karin Sjöberg Enhetschef Box 21060, SE-100 31 Stockholm Box 5302, SE-400 14 Göteborg Valhallavägen 81, Stockholm Aschebergsgatan 44, Göteborg Tel: +46 (0)8 598 563 00 Tel: +46 (0)31 725 62 00 Fax: +46(0)8 598 563 90 Fax: + 46 (0)31 725 62 90 www.ivl.se

Contents 1. Introduction... 2 2. Purpose of the measurements... 2 3. Measurement method... 2 3.1 General... 2 3.2 Sampling techniques... 2 3.3 Analysis of odour samples... 5 4. Results... 5 4.1 Odour concentration... 5 4.2 Exhaust flow... 6 4.3 Ozone concentration... 6 5 Comments on the results... 6 Appendix Åf-Consult AB (Analysis of odour samples) 1

1. Introduction IVL Swedish Environmental Research Institute has been commissioned by Interzon AB to undertake analysis of odour samples in a kitchen exhaust duct that ventilates a Burger King restaurant in Sweden. The measurements were undertaken on the 15 th December 2010 and 25 th January 2011. The contact at Interzon AB was Mika Lindfors. Interzon AB has recently developed and introduced a unique system for removal of grease and odour in commercial kitchen exhaust ducts. The system is sold under the registered trade mark AirMaid and is based on the company s own ozone cell called CGC (Corona Glass Cell). Ozone is brought into the exhaust duct and oxidizes compounds of grease and odour to water and dry minerals. The system is practically maintenance free since it requires only one yearly inspection and no consumption parts for the ozone production. The system requires only electricity and air for the ozone production. The system is also easy to install and fits into any type of commercial kitchen. 2. Purpose of the measurements The main purpose of the measurements in a kitchen exhaust duct were to study odour concentrations in a kitchen exhaust duct with and without an installed AirMaid ozone generator. 3. Measurement method 3.1 General Measurements were undertaken in the ventilation shaft on the 15 th December 2010 in a restaurant without installed AirMaid ozone generator for kitchen ventilation and 25 th January 2011 in a restaurant with AirMaid ozone generator installed. Both measurements were undertaken during busy periods for each restaurant 11: 00-12: 30. Ozone generators (AirMaid) was installed after sample point 3 and 4. See project plan figure 1. 3.2 Sampling techniques Samples are taken in airtight bags especially for the purpose. The air sample is then analysed sensorial within 30 hours. In the figure 1 shows the project plan of the odour and ozone measurements at Burger King restaurant, Medborgarplatsen, Stockholm, Sweden. In the figure 2-3 shows the location of the odour sampling after the fan unit (Burger King`s restaurant in central Stockholm). 2

Figure 1 Project plan of the measurements at Burger King restaurant. 3

Figure 2 Odour sampling after the fan unit (sample point 6) Figure 3 Odour sampling in the kitchen (sample point 2 and 3) 4

3.3 Analysis of odour samples In appendix 1 (Åf-Consult AB) are the methodology for sensory odour evaluation describe. 4. Results 4.1 Odour concentration Samples for determining odour concentration are taken in bags and the analysis is conducted within 30 hours of the sample being taken. The results of the odour analyses are presented in table 1, 2 and 3 as the number of odour units per cubic meter. In table 1 are the results before AirMaid was installed and in table 2 after AirMaid was installed. In table 3 show the results of odour concentration after that the AirMaid was temporary shut off. Observe that AirMaid are installed after sample point 3 and 4 and there for only give an effect on odour concentration at sample point 5 and 6. Table 1 Results of the odour analyses without AirMaid installed Sampling date Sampling time Sample point Odour concentration Without AirMaid installed (ou/m 3 ) 15 th December 2010 11: 00-12: 30 1 6350 15 th December 2010 11: 00-12: 30 2 8980 15 th December 2010 11: 00-12: 30 3 4490 15 th December 2010 11: 00-12: 30 4 3084 15 th December 2010 11: 00-12: 30 5 1542 15 th December 2010 11: 00-12: 30 6 2828 Table 2 Results of the odour analyses with AirMaid installed Sampling date Sampling time Sample point Odour concentration With AirMaid installed (ou/m 3 ) 25 th January 2011 11: 00-12: 30 1 18390/35734 25 th January 2011 11: 00-12: 30 2 4598/8192 25 th January 2011 11: 00-12: 30 3 4871/3597 25 th Januari2011 11: 00-12: 30 4 5793/6502 25 th January 2011 11: 00-12: 30 5 790/1772 25 th January2011 11: 00-12: 30 6 790/1024 5

Table 3 Results of the odour analyses with AirMaid temporary shut off. Sampling date Sampling time Sample point Odour concentration With AirMaid temporary shut off (ou/m 3 ) 25 th January 2011 11: 00-12: 30 5 1878/1579 25 th January 2011 11: 00-12: 30 6 6889/1772 4.2 Exhaust flow Exhaust flow from the ventilation of the kitchen ducts was measure at sample point 6 just before the fan. The flow was measure with S-pitot tube and micromanometer. Sample flow was calculated to 6.300 m 3 /h. 4.3 Ozone concentration Ozone concentration was measured (25 th January 2011) at the sample point 5 between 13: 50 to 13: 59. The mean value of the measurements 0.920 ppm ozone. 5 Comments on the results Odour measurements from Burger Kings restaurant in Stockholm (figure 4) with AirMaid ozone generator installed shows that the odour concentration was reduced at the best with 89% at sample point 6. As an average over time the odour concentration was reduced between 80-90%. Figure 5 and 6 shows the duct before and after the installation of the AirMaid. Figure 4 Picture of the Burger Kings restaurant in Stockholm 6

Figure 5 Picture inside the duct before installed AirMaid (December 2010). Figure 6 Picture inside the duct after installed AirMaid (January 2011). 7

Rapport 1 (18) 2011-02-09 Handläggare Svensson Helen Tel 010-505 31 76 Fax 010-505 31 91 Helen.Svensson@afconsult.com Datum 2011-02-09 Uppdragsnummer 401789 Rapport nr G110110 IVL Luktmätning 1

Rapport 2 (18) 2011-02-09 Innehåll 1 Inledning 4 2 Bakgrund 4 3 Metodik 4 3.1 Sensorisk luktanalys 4 4 Mätosäkerhet 5 5 Resultat 5 6 Kommentarer till resultatet 5 Bilagor Bilaga 1 Metodbeskrivning för sensorisk luktbedömning Bilaga 2 Rådata 2

Rapport 3 (18) 2011-02-09 Sammanfattning På uppdrag av IVL har ÅF utfört bestämning av luktkoncentration i prover tillhandahållna av företaget. Mätningarna genomfördes den 16 december 2010 samt den 26 januari 2011. Ansvarig för mätningarnas genomförande och rapportsammanställning är Helen Svensson vid ÅF:s kontor i Göteborg. Analyser har även utförts av Markus Olofsgård vid samma kontor. Mätning avseende luktkoncentration utfördes med dynamisk olfaktometri med luktpanel. I nedanstående tabell redovisas resultatet av de genomförda analyserna. Resultat från luktanalys Provpunktens beteckning Luktkoncentration (le/m 3 ) utan rening, 16 dec 1 12 000 25 600 2 8 900 6 100 3 3 900 4 200 4 3 500 6 100 5 1 542 1 200 6 2 100 900 Luktkoncentration (le/m 3 ) med rening, 26 jan Luktkoncentrationen sjunker från provpunkt 1 till 6 vid båda provtagningstillfällena. Resultat från luktanalys av provpunkter med liknande produktionsförhållanden Provpunktens Luktkoncentration (le/m 3 ) Luktkoncentration (le/m 3 ) Reningsgrad beteckning utan rening, 26 jan med rening, 26 jan 5 1 700 1 200 31 6 4 330 900 79 Reningen är bättre i punkt 6 än i punkt 5. I punkt 6 är reningen ca 79 %. 3

Rapport 4 (18) 2011-02-09 1 Inledning På uppdrag av IVL har ÅF utfört bestämning av luktkoncentration i prover tillhandahållna av företaget. Mätningarna genomfördes den 16 december 2010 samt den 26 januari 2011. Ansvarig för mätningarnas genomförande och rapportsammanställning är Helen Svensson vid ÅF:s kontor i Göteborg. Analyser har även utförts av Markus Olofsgård vid samma kontor. 2 Bakgrund IVL har på uppdrag av en av deras kunder anlitat ÅF:s luktlaboratorium för att genomföra luktanalyser på prover uttagna av IVL. 3 Metodik Vid bestämning av luktkoncentration tas luftprover ut i gastäta påsar vid den luktande källan. Dessa analyseras sedan sensoriskt. För att kunna bestämma luktbelastningen måste även flödesmätning genomföras. Ansvarig för provtagningen är IVL. 3.1 Sensorisk luktanalys Vid sensorisk luktanalys bestäms luktkoncentrationen i ett prov med hjälp av ett spädningsinstrument (olfaktometer) och en panel bestående av fyra godkända panelister. Luktkoncentrationen mäts i enheten luktenheter per kubikmeter, l.e./m 3. Inledningsvis tillförs ren luft till panelen varefter koncentrationen av provluften successivt ökar. Vid en viss given utspädning kan lukt från provluften förnimmas, denna nivå registreras för respektive panelist. Panelens gemensamma lukttröskelvärde beräknas som det geometriska medelvärdet av panelisternas individuella lukttrösklar. Detta värde motsvarar den koncentration vid vilken 50 % av populationen kan förnimma lukt. Antalet luktenheter i provet motsvarar det antal gånger som provet måste spädas med luktfri luft innan luktfrihet uppnås. För mer information om sensorisk luktanalys, se bilaga 1. Tabell 2 Metodförteckning Analys variabel Metod Analysprincip Mätområde Lukt SS-EN 13725 (inkl. provtagning) Olfaktmetri; sensorisk analys Spädning 2,5 ggr till oändligt Mätosäkerhet vid 95 % konfidensnivå Se bilaga 2 4

Rapport 5 (18) 2011-02-09 4 Mätosäkerhet N-butanoltesterna genomförs innan varje analys görs för att testa panelisternas luktsinne. För detta ändamål används ett särskilt ämne (n-butanol) där lukttröskeln är väldokumenterad. För ett godkännande av panelisten krävs att personen i fråga känner lukt av n-butanol inom ett visst intervall runt den kända och väldokumenterade lukttröskeln för ämnet och med en viss standardavvikelse. Mätosäkerheten för lukt är definierad som reproducerbarheten hos det ovan nämnda n- butanoltestet som görs innan varje luktanalys. Med reproducerbarhet åsyftas den förmåga panelen har att ange samma resultat vid flera tillfällen för ett och samma testmaterial under likvärdiga förhållanden. Mätosäkerheten redovisas som en faktor kring ett givet medelvärde. Normalt hamnar denna faktor på en nivå strax under 2. Detta innebär att om resultatet från en analys visar på 1 000 l.e./m 3 och så ligger det sanna värdet någonstans mellan 500 och 2 000 vid en mätosäkerhet på 2. Resultatet indikerar då att med 95 % säkerhet(95 % konfidensintervall) kan 50 % av populationen förnimma lukten inom intervallet 500 till 2000 le/m 3. Faktorn för mätosäkerhet vid denna mätning finns redovisad i Bilaga 2. 5 Resultat Prover för bestämning av luktkoncentration tas ut i påse och analysen genomförs inom 30 timmar från uttaget. Resultaten från luktanalyserna redovisas nedan som antalet luktenheter per kubikmeter. Tabell 3 Resultat från luktanalyserna Provpunktens beteckning Luktkoncentration (le/m 3 ) utan rening, 16 dec Luktkoncentration (le/m 3 ) med rening, 26 jan 1 12 000 25 600 2 8 900 6 100 3 3 900 4 200 4 3 500 6 100 5 1 542 1 200 6 2 100 900 6 Kommentarer till resultatet Som framgår av ovanstående tabell 3 har två serier luktprover analyserats vid två olika tillfällen. Produktionsförhållandena vid de båda tillfällena är ej definierade. I båda mätserierna sker en reduktion av luktinnehållet mellan provpunkt 1 och 6. Orsaker till detta är inte klarlagt med den information som är känd idag. Efter den årliga servicen av analysinstrumentet ombads IVL att ta om proverna med reningsanläggningen avstängd vid den andra mätningen den 24 januari. Detta gjordes och följande resultat erhölls: 5

Rapport 6 (18) 2011-02-09 Tabell 4 Resultat från luktanalys av provpunkter med liknande produktionsförhållanden Provpunktens beteckning Luktkoncentration (le/m 3 ) utan rening, 26 jan Luktkoncentration (le/m 3 ) med rening, 26 jan Reningsgrad (%) 5 1 700 1 200 31 6 4 330 900 79 I och med att proverna togs ut vid samma tillfälle rådde det liknande produktionsförhållanden både med och utan rening. Slutsatsen som kan dras av dessa resultat är således att ozonreningen verkar fungerar bättre i punkt 6 än i punkt 5. Reningsgraden i punkt 6 är enligt resultaten ca 79 %. 6

Bilaga 1 7 (18) Metodbeskrivning för sensorisk luktbedömning Nedan ges en kortfattad beskrivning av mätmetodiken samt utvärderingsförfarandet vid en sensorisk luktbedömning. Provtagning, analys samt utvärdering följer den svenska och europeiska standarden SS-EN 13725 Luftkvalitet - Bestämning av luktkoncentration med dynamisk olfaktometri. Provtagning Prover uttas i lufttäta och för ändamålet speciellt anpassade påsar. Den uttagna luften analyseras sedan sensoriskt inom 30 timmar. Luktbedömning Analysen sker dels med hjälp av en utspädningsenhet, en så kallad olfaktometer, dels med en "detektionsenhet" bestående av en tränad provpanel. Panelen består av minst fyra personer. Den använda olfaktometern är av typ ECOMA TO7. I olfaktometern blandas provgas med spädluft som utgörs av omgivningsluft som renas genom kolfilter. För varje prov genomförs minst två spädserier där panelisterna får avgöra vid vilken spädnivå lukt kan förnimmas. Respektive spädserie är så utformad att halten luktämnen successivt ökar. Under provtagningen genomförs ca 20 % nollprov, dvs. paneldeltagarna testas på enbart spädluft, vid ca vart femte prov. Nollproverna genomförs för att följa panelisternas uppmärksamhet. Olfaktometern styrs av ett datorprogram som styr vilken spädnivå som skall ställas in och fördelar provgasen mellan panelisterna. Startordning och nollprovens placering väljs slumpmässigt av programmet. Även utvärderingen av resultatet sker i programmet. Utvärdering av resultat Den utspädningsnivå vid vilken panelisterna känner första luktförnimmelsen motsvarar en l.e./m 3. Panelens gemensamma lukttröskelvärde beräknas som det geometriska medelvärdet av panelisternas individuella lukttrösklar. Detta värde motsvarar den koncentration vid vilken 50 % av populationen kan förnimma lukt. Det antal gånger som provet behöver spädas för att panelisterna ska förnimma lukt är luktkoncentrationen i det analyserade provet angivet i l.e./m 3. Antalet luktenheter motsvarar alltså det antal gånger som provet måste spädas med luktfri luft innan luktfrihet uppnås. 7

Bilaga 2 8 (18) Rådata 2010-12-16 Provpunktens Tidpunkt för Tidpunkt Luktkoncentration Faktor för Förspädning beteckning provtagning för analys (le/m 3 ) mätosäkerhet 1A Saknas 15:28-6 350 1,94 1B Saknas 15:18-22 627 1,94 2A Saknas 09:04-8 980 1,94 2B Saknas 09:21-8 724 1,94 3A Saknas 14:35-4 490 1,94 3B Saknas 14:53-3 364 1,94 4A Saknas 09:47-3 084 1,94 4B Saknas 09:32-4 000 1,94 5A Saknas 11:19-1 542 1,94 6A Saknas 10:03-2 828 1,94 6B Saknas 10:32-1 610 1,94 Utrustningens identifikation Olfaktometer TO7, serienummer EO.095 Senaste kalibrering av olfaktometern 2010-02-18 Proverna har ej varit över 25 C vid transport Uppgift saknas Temperatur i rummet vid analystillfället 19 C Referensgas n-butanol, 112 ppm Datum för provtagningen 2010-12-15 Datum för analysen 2010-12-16 Analysen är utförd av Helen Svensson 8

Bilaga 2 9 (18) Rådata 2011-01-26 förmiddag Provpunktens Tidpunkt för Tidpunkt Luktkoncentration Faktor för Förspädning beteckning provtagning för analys (le/m 3 ) mätosäkerhet 1A Saknas 15:25-18 390 2,12 1B Saknas 15:33-35 734 2,12 2A Saknas 15:04-4 598 2,12 2B Saknas 14:48-8 192 2,12 3A Saknas 13:32-4 871 2,12 3B Saknas 13:56-3 597 2,12 4A Saknas 13:22-5 793 2,12 4B Saknas 13:05-6 502 2,12 Utrustningens identifikation Olfaktometer TO8, serienummer EO.8017 Senaste kalibrering av olfaktometern 2010-03-10 Proverna har ej varit över 25 C vid transport Uppgift saknas Temperatur i rummet vid analystillfället 22 C Referensgas n-butanol, 112 ppm Datum för provtagningen 2011-01-25 Datum för analysen 2011-01-26 Analysen är utförd av Helen Svensson 9

Bilaga 2 10 (18) Rådata 2011-01-26 eftermiddag Provpunktens Tidpunkt för Tidpunkt Luktkoncentration Faktor för Förspädning beteckning provtagning för analys (le/m 3 ) mätosäkerhet 5A med rening Saknas 12:42-790 2,04 5B med rening Saknas 12:49-1 772 2,04 6A med rening Saknas 12:16-790 2,04 6B med rening Saknas 12:28-1 024 2,04 5C utan rening Saknas 16:13-1 878 2,04 5D utan rening Saknas 16:05-1 579 2,04 6C utan rening Saknas 15:42-6 889 2,04 6D utan rening Saknas 15:49-1 772 2,04 Utrustningens identifikation Olfaktometer TO8, serienummer EO.8017 Senaste kalibrering av olfaktometern 2010-03-10 Proverna har ej varit över 25 C vid transport Uppgift saknas Temperatur i rummet vid analystillfället 23 C Referensgas n-butanol, 112 ppm Datum för provtagningen 2011-01-25 Datum för analysen 2011-01-26 Analysen är utförd av Markus Olofsgård 10