MANUAL LUNE SPA. Läs mer om våra spabad på www.prospa.se eller ring 0472-44010



Relevanta dokument
MANUAL LUNE SPA. Läs mer om våra spabad på eller ring

MANUAL LUNE SPA. Läs mer om våra spabad på eller ring

Ditt spa styrsystem modell: VS/GS501Z VS/GS510SZ VS/GS523DZ GL8000. Annan:

Säkerhetsanvisningar

Bruksanvisning UCR-100

Ditt spa styrsystem modell: VS/GS501Z VS/GS510SZ VS/GS523DZ GL8000. Annan:

Manual. Mini. En Joystickmus för styrning av datorer Point-it! Mini USB Point-it! Mini USB Kula

Bruksanvisning - Spisvakt Prefi 2.3

Boiler with heatpump / Värmepumpsberedare

Vehicle Security System VSS3 - Vehicle original remote

Box 79 Hantverksvägen 15 Tel. +46 (0) Web Väddö, Sverige Fax +46 (0)

Svensk Bruksanvisning

Vehicle Security System VSS3 - Alarm system remote

SkillGuide. Bruksanvisning. Svenska

Tack för att du köpt vår digitala MP3-spelare. Innan du använder spelaren, läs igenom den här användarhandboken så att du vet hur spelaren fungerar.

INSTALLATIONS- OCH BRUKSANVISNING FÖR UTESPABAD

Remote control Fjärrströmbrytare / Fjernstrømbryter

SOLCELLSBELYSNING. En praktisk guide. Råd & Tips SOLENERGI LADDA MED. Praktiska SÅ TAR DU BÄST HAND OM DIN SOLCELLSPRODUKT

Efter att du har installerat ExyPlus Office med tillhörande kartpaket börjar du med att göra följande inställningar:

Säkerhetsanvisningar

Skrivarinställningar. Visa startsidan. Via skrivarens frontpanel. Via CentreWare IS. Phaser 6250 färglaserskrivare

Hur skapar man formula r

Ersättning styrkort GOLD, stl 1-3, Version 1-3/ Replacement control circuit board GOLD, sizes 1-3, Version 1-3

Bruksanvisning. Elverk Art.: Annelundsgatan 7A I Enköping I Tel I Fax I

REGION SKÅNE VDI KLIENTINSTALLATION

Användarmanual. På grund av ständiga tekniska uppgraderinga kan dessa instruktiner komma att ändras utan någon förvarning. RLS En.

AquaKing. Användarmanual VARNING!

InstalationGuide. English. MODEL:150NHighGain/30NMiniUSBAdapter

Huvudskärmen. Menyalternativen till höger kan väljas och skärmen ändras för att visa mer detaljerade kontroller eller programmering funktioner.

BRUKSANVISNING. Oscilla 910

Portabel Luftkonditionering A/C Milan

Bruksanvisning. Multimeter KEWTECH KT115

Digital dagtidsklocka med vecko-/dagsprogram och blandad händelsegenerator.

APEX Flex ProChip System

Installation Instructions

INSTALLATION INSTRUCTIONS

För dig som är valutaväxlare. Så här följer du reglerna om penningtvätt i din dagliga verksamhet INFORMATION FRÅN FINANSINSPEKTIONEN

Beijer Electronics AB 2000, MA00336A,

Design by. Manual Jossan.exe. Manual. till programmet. Jossan.exe. E-post:

Fullför installation av ELIQ

INSTALLATIONSguide POWER 2.5 DC RTS

ANALOGT KVARTSUR Bruksanvisning

Manual Gamla Akka-plattan

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

FRÅN A TILL Ö LäraMera Ab / och Allemansdata Ab / FRÅN A TILL Ö

Utforska rymden med iphone

Dokumentnamn Order and safety regulations for Hässleholms Kretsloppscenter. Godkänd/ansvarig Gunilla Holmberg. Kretsloppscenter

Windlass Control Panel v1.0.1

5-växlad manuell direktväxlad växellåda 085 DS: Grundinställning

Total Control snabbguide

Rev No. Magnetic gripper 3

Manual Milestone 112. Iris Hjälpmedel AB Juni 2011 Ver: 1.01

Får endast utföras av behörig personal. May only be carried out by authorized electrician

MultiBoot. Användarhandbok

Manual för Polarheat värmepumpar

Felanmälan eller Arbetsorder

säkerhetsutrustning / SAFETY EQUIPMENT

433 MHZ Termometer Bruksanvisning

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

StyleView Primary Drawer

11. Använd inte produkten i miljöer med hög luftfuktighet och höga temperaturer. Använd den inte heller i närheten av värmekällor (t.ex. element).

Texturbild. Lagerpaletten du kommer arbeta med ser du till höger. 1. Kopiera bakgrunden till ett nytt lager och gör den svartvit.


FIX LED-LYSRÖRSARMATUR MED AKRYLKÅPA IP44

Bruksanvisning Twain / WIA Software für DIAGNOcam Alltid på den säkra sidan.

Att koda en magnetremsa i plastkortskrivare med inbyggd magnetkodare.

MultiBoot Användarhandbok

electiaprotect GSM SEQURITY SYSTEM Vesta EZ Home Application SMART SECURITY SYSTEMS! SVENSKA ios Android

Praktisk programmering

Programmera en NXT Robot

BESKRIVNING AV MASKIN

Handbok Blinken. Danny Allen Översättare: Stefan Asserhäll

Installationsguide. Allt du behöver veta för att koppla in din IPTV-box

Hjälp för digital röst. Mikro Værkstedet A/S

Manual för BPSD registret. Version 6 /

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter

Installationsinstruktion TimeLox Wallox E Standard

Dornbracht eunit Kitchen. Manual. Culturing Life. 3 Produktbeskrivning. 5 Funktioner. 21 Väntmeddelande. 20 Servicemeddelande.

2.45GHz CF Card Reader User Manual. Version /09/15

Bra att veta samt tips och trix i SiteVision 3

Rekonditionering. Handifon HD mini

Monteringsanvisning Garageport

BBT057/ BBC057 BBCD057/ BBT057-NL HOLDEN COLORADO 9/2016+ HOLDEN TRAILBLAZER WD & 4WD Models

DIGITAL KLOCKRADIO MED DUBBLA LARM

XUMO. Trådlös PIR. Manual SV.

Finns det någon som kan förklara varför man inte kan använda formeln P=U I rotenur3 cosfi på en pump som sitter i en borrad brunn?

MCP-16RC, Air Purification

Laganmälan & Laghantering

AM / FM Stereo Digital Radio 381RH13-A. Bruksanvisning PR-D7

MANUAL V-COM M80 TRANSPORT

CXA60/80 INTEGRERAD FÖRSTÄRKARE

Avsikt På ett lekfullt sätt färdighetsträna, utveckla elevers känsla för hur vårt talsystem är uppbyggt samt hitta mönster som uppkommer.

Visma Proceedo. Att attestera - Manual. Version 1.4. Version 1.4 /

Fack. Phaser 4400 laserskrivare. Detta avsnitt handlar om:

4 p o r t s 1 0 / m b p s

BrukSAnviSning. SAFERA Siro R spisvakt

Anvisning för Guide for

GOLD SD Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1. Fläkt 2/ Fan 2. Med filter/ With filter Filter

SE Bruksanvisning. VIKTIGT: Både kanten på torkarbladet och Mr. Ti s uppsamlingsdel ska komma i direkt kontakt med glasrutan.

Transkript:

MANUAL LUNE SPA Läs mer om våra spabad på www.prospa.se eller ring 0472-4400

Warm Cool Jets Blower http://www.balboawatergroup.com/ Temp Control (80 F - 04 F / 26.0 C - 40.0 C) Jets Press Jets to turn pump on or off, and to shift between low 4 hours. High-speed will turn off after 5 minutes. Low-speed off. The device will turn off after 5 minutes. Pump 2 may be Setting the of Day on the display. Press, then, then Warm or the spa will run in Standard Mode (see section). This document covers VS and GS systems 500DZ through 520DZ with Balboa Panels VL80D or VL802D. button. temp is not current, and ECONOMY icon Sleep Mode heats the spa to within 20 F/0 C of the set temperature only during 0:00 AM. The second preset fi lter cycle starts at 8:00 PM and ends at 0:00 PM. For non-circ systems, low-speed pump and the ozone generator to, press,, within 3 seconds. SET START FILTER (AM) will appear. Press Warm or Cool to Press to see SET STOP FILTER and adjust the time with Warm or Cool as done above. Press to see SET START FILTER 2 (PM) and proceed as above. Press to see SET STOP FILTER 2 and proceed as above. Press The pump responsible for heating and fi ltration (pump low-speed Bruksanvisning för Lune Uppstarten Ditt spa kommer att gå in i ett Priming-läge (Pr) när det aktiveras. Under Priming-läget, tryck upprepade gånger på Jets -knappen (s) för att säkerställa att alla pumpar är fria från luft. Priming- läget varar mindre än 5 minuter. Tryck på Warm eller Cool för att avsluta. Efter Priming-läget kommer ditt spa att köras i standardläge (se avsnittet ). Pumpen som ansvarar för uppvärmning och filtrering (låghastighet pump på icke-cirksystem eller circ-pumpen på circsystem) kommer bara att kallas pumpen i den här anvisningen. Tänk på att när du trycker på flera knappar för att utföra en viss sekvens, ska du inte trycka för snabbt, för då hinner de inte alltid registreras. Temp Control (80 F - 04 F / 26,0 C - 40,0 C) Det är alltid den senast uppmätta vattentemperaturen som visas. Vattentemperaturen som visas är aktuell endast när pumpen har varit igång i minst 2 minuter. För att visa den inställda temperaturen, tryck på Warm eller Cool en gång. För att ändra den inställda temperaturen, tryck på en temp-knappen igen innan displayen slutar blinka. Efter tre sekunder slutar den blinka och då visas den aktuella spa-temperaturen. Jets Tryck på Jets för att starta eller stoppa pump, eller för att skifta mellan låg och hög hastighet (om sådan finns). Den låga hastigheten stängs av efter 4 timmar. Höghastigheten stängs av efter 5 minuter. Låghastighet kan köras i automatiskt tidsläge, och kan då inte avaktiveras från panelen, men höghastighet kan fortfarande manövreras. Jets 2/Jets 3/Blower (om sådan finns) Tryck på gällande knapp en gång för att sätta på eller stänga av enheten. Enheten stängs av efter 5 minuter. Pump 2 kan ha två hastigheter på vissa system. Om panelen har en knapp med 2 enheter kopplade till den, exempelvis pump 2 och pump 3, ska du trycka på knappen upprepade gånger för att stega igenom olika kombinationer av On och Off för båda enheterna. Ljus Tryck på för att tända belysningen. Det stängs av efter 4 timmar. Ställa in tiden När ditt spa startas första gången, kommer orden SET TIME att blinka på displayen. Tryck på och sedan och därefter Warm eller Cool. Tiden kan justeras i steg om en minut. Tryck Warm eller Cool för att stanna vid rätt tid. Tryck på för att bekräfta. Du ändrar läge genom att trycka på Warm eller Cool och sedan trycka på -knappen. Standardläge håller inställd temperatur och ikonen STANDARD kommer att visas. Ekonomiläge värmer spaet till inställd temperatur endast under filtercykler. Ecn visas när vattentemperaturen inte är den förinställda, och kommer att alterneras på displayen med aktuell vatten- temperatur när pumpen är igång. EKONOMI-ikonen visas då. Viloläget värmer spaet till inom 20 F/0 C av den inställda temperaturen endast under filtercykler. SLP visas när vattentemperaturen inte är den förinställda, och kommer att växlas på displayen med aktuell vattentemperatur när pumpen är igång. Förinställda filtercykler Den första förinställda filtercykeln börjar klockan 08:00 och slutar vid 0:00. Den andra filtercykeln börjar 20:00 och slutar vid 22:00. Icke-circsystem, låg hastighet pump och ozongenerator (om installerat) körs under filtreringen. 24-timmars cirkulationssystem, CIRC-pumpen och ozongenerator (om installerat) körs under 24 timmar. I varma miljöer kan circpumpen stängas av i 30 -minutersperioder, förutom under filtercykeln. Icke-24-timmars cirkulationssystem, CIRC pumpen och ozongenerator (om installerat) körs under filtreringen (och kan även köras automatiskt vid andra tillfällen). I början av varje filtercykel ska all annan utrustning köras kort för att rensa avlopp. Programmering av valfri filtercykel Du behöver inte ändra filtercyklar, men om du ändå vill det, ska du trycka på,, inom 3 sekunder. SET START FILTER (AM) visas. Tryck då Warm eller Cool för att återställa starttiden. Tryck på för att se SET STOPP FILTER och justera tiden med Warm eller Cool enligt ovan instruktion. Tryck på för att se SET START FILTER 2 (PM) och fortsätt enligt ovan. Tryck på för att se SET STOPP FILTER 2 och fortsätt enligt ovan. Tryck sedan på för att bekräfta. Warm Cool Jets Blower http://www.balboawatergroup.com/ Temp Control (80 F - 04 F / 26.0 C - 40.0 C) Jets Press Jets to turn pump on or off, and to shift between low 4 hours. High-speed will turn off after 5 minutes. Low-speed off. The device will turn off after 5 minutes. Pump 2 may be Setting the of Day on the display. Press, then, then Warm or the spa will run in Standard Mode (see section). This document covers VS and GS systems 500DZ through 520DZ with Balboa Panels VL80D or VL802D. button. temp is not current, and ECONOMY icon Sleep Mode heats the spa to within 20 F/0 C of the set temperature only during 0:00 AM. The second preset fi lter cycle starts at 8:00 PM and ends at 0:00 PM. For non-circ systems, low-speed pump and the ozone generator to, press,, within 3 seconds. SET START FILTER (AM) will appear. Press Warm or Cool to Press to see SET STOP FILTER and adjust the time with Warm or Cool as done above. Press to see SET START FILTER 2 (PM) and proceed as above. Press to see SET STOP FILTER 2 and proceed as above. Press The pump responsible for heating and fi ltration (pump low-speed Warm Cool Jets Blower http://www.balboawatergroup.com/ Temp Control (80 F - 04 F / 26.0 C - 40.0 C) Jets Press Jets to turn pump on or off, and to shift between low 4 hours. High-speed will turn off after 5 minutes. Low-speed off. The device will turn off after 5 minutes. Pump 2 may be Setting the of Day on the display. Press, then, then Warm or the spa will run in Standard Mode (see section). This document covers VS and GS systems 500DZ through 520DZ with Balboa Panels VL80D or VL802D. button. temp is not current, and ECONOMY icon Sleep Mode heats the spa to within 20 F/0 C of the set temperature only during 0:00 AM. The second preset fi lter cycle starts at 8:00 PM and ends at 0:00 PM. For non-circ systems, low-speed pump and the ozone generator to, press,, within 3 seconds. SET START FILTER (AM) will appear. Press Warm or Cool to Press to see SET STOP FILTER and adjust the time with Warm or Cool as done above. Press to see SET START FILTER 2 (PM) and proceed as above. Press to see SET STOP FILTER 2 and proceed as above. Press The pump responsible for heating and fi ltration (pump low-speed Warm Cool Jets Blower Temp Control (80 F - 04 F / 26.0 C - 40.0 C) Jets Press Jets to turn pump on or off, and to shift between low 4 hours. High-speed will turn off after 5 minutes. Low-speed off. The device will turn off after 5 minutes. Pump 2 may be Setting the of Day on the display. Press, then, then Warm or the spa will run in Standard Mode (see section). This document covers VS and GS systems 500DZ through 520DZ with Balboa Panels VL80D or VL802D. button. temp is not current, and ECONOMY icon Sleep Mode heats the spa to within 20 F/0 C of the set temperature only during 0:00 AM. The second preset fi lter cycle starts at 8:00 PM and ends at 0:00 PM. For non-circ systems, low-speed pump and the ozone generator to, press,, within 3 seconds. SET START FILTER (AM) will appear. Press Warm or Cool to Press to see SET STOP FILTER and adjust the time with Warm or Cool as done above. Press to see SET START FILTER 2 (PM) and proceed as above. Press to see SET STOP FILTER 2 and proceed as above. Press The pump responsible for heating and fi ltration (pump low-speed Warm Cool Jets Blower Temp Control (80 F - 04 F / 26.0 C - 40.0 C) Jets Press Jets to turn pump on or off, and to shift between low 4 hours. High-speed will turn off after 5 minutes. Low-speed off. The device will turn off after 5 minutes. Pump 2 may be Setting the of Day on the display. Press, then, then Warm or the spa will run in Standard Mode (see section). This document covers VS and GS systems 500DZ through 520DZ with Balboa Panels VL80D or VL802D. button. temp is not current, and ECONOMY icon Sleep Mode heats the spa to within 20 F/0 C of the set temperature only during 0:00 AM. The second preset fi lter cycle starts at 8:00 PM and ends at 0:00 PM. For non-circ systems, low-speed pump and the ozone generator to, press,, within 3 seconds. SET START FILTER (AM) will appear. Press Warm or Cool to Press to see SET STOP FILTER and adjust the time with Warm or Cool as done above. Press to see SET START FILTER 2 (PM) and proceed as above. Press to see SET STOP FILTER 2 and proceed as above. Press The pump responsible for heating and fi ltration (pump low-speed Warm Cool Jets Blower http://www.balboawatergroup.com/ Temp Control (80 F - 04 F / 26.0 C - 40.0 C) Jets Press Jets to turn pump on or off, and to shift between low 4 hours. High-speed will turn off after 5 minutes. Low-speed off. The device will turn off after 5 minutes. Pump 2 may be Setting the of Day on the display. Press, then, then Warm or the spa will run in Standard Mode (see section). This document covers VS and GS systems 500DZ through 520DZ with Balboa Panels VL80D or VL802D. button. temp is not current, and ECONOMY icon Sleep Mode heats the spa to within 20 F/0 C of the set temperature only during 0:00 AM. The second preset fi lter cycle starts at 8:00 PM and ends at 0:00 PM. For non-circ systems, low-speed pump and the ozone generator to, press,, within 3 seconds. SET START FILTER (AM) will appear. Press Warm or Cool to Press to see SET STOP FILTER and adjust the time with Warm or Cool as done above. Press to see SET START FILTER 2 (PM) and proceed as above. Press to see SET STOP FILTER 2 and proceed as above. Press The pump responsible for heating and fi ltration (pump low-speed

Låsa panelen Tryck på, Blower, och Warm inom 3 sekunder. Panelen är nu låst. För att låsa upp igen, trycker du på, Blower och Cool inom 2 sekunder. Låsa temperaturen Tryck Warm,, Blower och Warm inom 3 sekunder. Nu är Warm - och Cool -knapparna inaktiverade. För att låsa upp temperaturen igen, tryck på, Blower och Cool inom 2 sekunder. Observera: på vissa system används Jets i stället för Blower för att låsa/låsa upp sekvenser. Diagnostiska meddelanden Meddelande Betydelse Åtgärd -- OHH OHS Inget meddelande på displayen. Strömmen har försvunnit från spaet. Temperatur okänd. Överhettning - spaet har stängts av * En av sensorerna har upptäckt 8 F/47.8 C vid uppvärmning. Överhettning - spaet har stängts av * En av sensorerna har upptäckt att vattnet är 0 F/43,5 C. Spaet stängs av. * Sensorn som är ansluten i A -jacket fungerar inte Spaet stängs av. * Sensorn som är ansluten i B -jacket fungerar inte Kontrollpanelen inaktiveras tills strömmen kommer tillbaka. Alla spainställningar kommer att bevaras tills nästa uppstart. Efter att pumpen varit igång i 2 minuter, kommer nuvarande vattentemperatur att visas. GÅ INTE I VATTNET. Ta av spa-locket och låt vattnet kylas av. När uppvärmaren har svalnat, återställer du genom att trycka på någon knapp. Om det inte återställs, stäng av strömmen och kontakta återförsäljaren eller ett serviceföretag. GÅ INTE I VATTNET. Ta av spa-locket och låt vattnet kylas av. Vid 07 F/4,7 C kommer spaet att automatiskt återställas. Om det inte återställs, stäng av strömmen och kontakta återförsäljaren eller ett serviceföretag. Om problemet kvarstår, kontakta din återförsäljare eller ett serviceföretag. (Kan visas tillfälligt vid tillstånd av överhettning). Om problemet kvarstår, kontakta din återförsäljare eller ett serviceföretag. (Kan visas tillfälligt vid tillstånd av överhettning). hfl lf ice Sensorer är ur balans. Om meddelandet växlar med spa-temperatur, kan det bara vara en tillfällig varning. Om det blinkar ensamt, kommer ditt spa stängas av. * En betydande skillnad mellan temperatursensorerna har identifierats. Detta kan indikera ett flödesproblem. Ihållande problem med lågt flöde (visas efter femte HFL-meddelandet inom 24 timmar). Uppvärmaren stängs av, medan de andra spa-funktionerna fortsätter att fungera normalt. Otillräcklig med vatten, dålig flöde eller luftbubblor har identifierats i uppvärmaren. Spaet stängs ner under 5 minuter. Otillräckligt vatten har identifierats i uppvärmaren (visas efter tredje dr-meddelandet). Spaet stängs av. * Ice Iskyla har identifierats. * - Även när spaet stängs av, kommer viss utrustning att slås på om det krävs frysskydd. Om problemet kvarstår, kontakta din återförsäljare eller ett serviceföretag. Om vattennivån är normal, kontrollera att alla pumpar har luftats. Om problemet kvarstår, kontakta din återförsäljare eller serviceföretag. Följ instruktionerna för HFL-meddelandet. Uppvärmningsförmågan kommer inte att återställas automatiskt, utan du måste trycka på valfri knapp. Om vattennivån är normal, kontrollera att alla pumpar har luftats. Tryck på valfri knapp för att återställa. Detta meddelande kommer att återställas inom 5 minuter. Om problem kvarstår, kontakta din återförsäljare eller ett serviceföretag. Följ åtgärder som krävs för dr-meddelandet. Spaet kommer inte automatiskt att återställas, så tryck på valfri knapp för att återställa det manuellt. Ingen åtgärd krävs. All utrustning ska aktiveras automatiskt oavsett spa-status. Utrustningen fortsätter 4 minuter till efter att sensorerna identifierat att spa-temperaturen stigit till 45 F/7.2 C eller högre. En frys-sensor finns som tillval, för att skydda mot extraordinär kyla. Ett extra skydd rekommenderas vid kallare klimat. Kontakta din återförsäljare för mer information.

Electric parameters VARNING FÖR ELSTÖTAR INGA DELAR DU BYTER PÅ EGEN HAND Försök inte själv serva detta styrsystem. Kontakta din återförsäljare eller serviceföretag för att få hjälp. Följ alla ströminstallationsanvisningar i denna manual. Installationen ska utföras av en legitimerad elektriker och alla jordförbindelser måste vara korrekt installerat.. Performance index: Rated voltage: 220VAC/50Hz Maximum working current:60a/220vac Voltage-resistance:250VAC/ minute without penetration Isolative resistance: 0MΩ Water resistance grade:ipx5 Electric shock resistance:first grade Elektriska specifikationer. 2. Prestandaindex Output loading index: Märkspänning: 220VAC/50Hz Heater: Spänningsmotstånd: 220VAC/3KW 250VAC/ minut utan penetration Water Vattenmotstånd, pump: 220VAC/0.75KW* kappslingsklass: IPX5 Ozone: Max arbetsström: 220VAC/0.005KW* 60A/220VAC Isolationsmotstånd: 0 M Ω Stötmotstånd: Första klass 2 Utgående effektindex Värmare: 220VAC/3KW Vattenpump: Water pump: 220VA/0,75KW* 220VAC/.5KW*2 Ozon: Spa light: 2VAC/0.005KW 220VAC/0,005KW* Vattenpump: 0VAC/,5KW* Spabelysning: 2VAC/0,005KW

Vatten-och strömförsörjnings installationsdiagram för Hydromassage-badkar Modell: LUNE Storlek: 220 x 960 x 960 mm Installationsanvisningar A. Vatten. Den behöver två galvaniserade vattenrör. En är för vattenresurser, en annan för vattenutlopp. De bör fästas på väggen 80 mm över golvet. En anordning för att stänga av vatten bör också sättas på väggen. B. Ström. Ström. Strömmen ska vara 220VAC/50Hz, enfas, 3 Amp. Uttaget bör vara vattentät, utformat för badrum och det bör placeras 200 mm ovanför golvet. C. Vattenpipen, vars radie är inom 0-40 mm, bör sättas i centrum av munstycket. (Enligt diagrammet).

Steg Ta bort kanten runt badkaret. Steg 2 Anslut huvudströmlådan till strömkälla Steg 3 Installera dräneringen Steg 4 Klart!

AS MANUFACTURED L N Electrical Service Configuration Options Systems with PCB Rev B Only AV F7 F J3 J50 J29 J23 K6 K OZONE PUMP K9 F0A 250V J52 J5 F6, T30A 480V F3A 250V J46 CIRC. PUMP K8 K5 J20 J25 C9 J32 ( x 32 Amp) F3 TB 0VAC J7/26 J72 3 Wires ( Line + Neutral + Protective Earth) F4, T0.2A 250V OPT. BLWR/PUMP 2 J7 T J58 2 3 4 J57 Balboa BALBOA INSTRUMENTS, INC. GS500Z COPYRIGHT 2007 Pb MADE IN U.S.A. P/N 2205_B W J47 To W on J28 J26 HTR2 J0 HTR 00 W2 To power on K3 K4 K2 Single Service, TN and TT Electrical Systems J This option is configured J2 and shipped as the default. J8 expander board) J43 J0runs on service line L. U4 F2 J9 S J90 J2 J60 J7 J8 J44 J6 x 6 Amp Service is not supported: TST SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J E.GND Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. All equipment (pumps, blower, heater and any JA J2A Systems using only DIP switch (A0) for heat disable: J22 For x 32 Amp Service: Set DIP Switch A0 such that total system amperage draw never exceeds rated service input. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set the switches shown in Table such that total system amperage draw never exceeds rated service input. 0VAC OPTIONAL L2 N2 L N J52 J5 F6, T30A 480V J57 J25 J32 2 3 4 Balboa BALBOA INSTRUMENTS, INC. GS500Z COPYRIGHT 2007 MADE IN U.S.A. P/N 2205_B Pb TB W J50 J47 G G N N AV CIRC. PUMP F4, T0.2A 250V J28 J26 HTR2 J0 HTR 00 J29 J23 OZONE PUMP W2 J58 K3 K4 K2 K9 F3 0VAC 5 Wires (2 J7/26Lines J72+ 2 Neutrals + Protective Earth) OPT. BLWR/PUMP 2 J7 T J90 K6 K J46 Dual Service, TN K8 and K5TT J20Electrical Systems C9 J The heater and any J2 expander board run on E.GND (2 x 6 Amp) J22 F7 F0A 250V JA J2A F3A 250V Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. service line L, while all other equipment, such as pumps and blowers, run on service line L2. J8 J43 J0 U4 Completely remove the white wire from J26 and J32. F2 J9 S Note: J32 and J25 are electrically J2 identical. The white J60 J7 J8 J44 J6 wire may be attached to either terminal before removal. TST SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J 0VAC F J3 To W on To power on Systems using only DIP switch (A0) for heat disable: DIP Switch A0 must be OFF. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table to ON positions. If using an Expander Board: Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table to OFF positions. Page 8 54763-0_97_D

OPTIONAL L3 L2 L N Electrical Service Configuration Options Systems with PCB Rev B Only AV F7 F J3 J50 J29 J23 K6 K OZONE PUMP K9 F0A 250V J52 J5 F6, T30A 480V F3A 250V J46 CIRC. PUMP K8 3-Phase Service, TN and K5 J20 TT Electrical Systems J25 C9 J32 5 Wires (3 Lines + Neutral + Protective Earth) F3 TB 0VAC J7/26 J72 F4, T0.2A 250V Protective OPT. BLWR/PUMP Earth 2 wire (Green/Yellow) J7 must be connected T J57 2 3 4 Balboa BALBOA INSTRUMENTS, INC. GS500Z COPYRIGHT 2007 MADE IN U.S.A. P/N 2205_B W J47 To W on Pb J28 J26 HTR2 J0 HTR 00 W2 J58 To power on K3 K4 K2 J90 E.GND to system ground terminal as marked. IMPORTANT - Service J MUST include a neutral wire, with a line to neutral voltage of 230VAC. J2 The heater runs on service line L. All main-board equipment run on service line L3. JA J2A Addtional equipment, such as expansion J8 boards, J43 J0 run on service line L2. F2 J9 S Completely remove the white wire J2 from J26 and J32, or J25. J60 J7 J8 J44 J6 Completely remove TST the blue wire from J28 and J58. SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J J22 Systems using only DIP switch (A0) for heat disable: DIP Switch A0 must be OFF. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table to ON positions. U4 0VAC NOTE: Not all GS5xxZ systems can support 3-Phase. 3-Phase requires System PCB Rev B. If using an expansion board, the board must have fuse-protection. Electrical Service Application Notes This page is specific to the GS523DZ model with 7A max pumps. (The preceeding pages cover all possible GS applications.) As manufactured, this system comes configured for Single Service. See the preceding pages for instructions on moving wires for Dual Service or Three-Phase configurations. Use the following guidelines for setting DIP Switches appropriately for the particular service configuration chosen. For x6a Service: Not Supported. For x32a Service: Switch A2 must be OFF and A0 can be ON. For 2x6A Service: Page 9 Switches A2 and A0 must be OFF (because Pumps 2 and 3 are on the same service as the Heater). 54763-0_97_D For 3-phase Service (6A per phase): Pump and blower are on one phase, Pumps 2 and 3 are on another phase, and the Heater is on its own phase. So there are no limitations needed on equipment running together. Thus switches A2 and A0 can both be ON.