Original instructions. SIRe Basic Fan Heaters Electric With quick guide. SIReBX. For wiring diagram, please see last pages.

Relevanta dokument
Original instructions. SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see last pages

Original instructions. SIRe Basic Air Curtains Water With quick guide. SIReB. For wiring diagram, please see last pages

Original instructions. SIRe Basic Fan Heaters Water With quick guide. SIReB. For wiring diagram, please see last pages.

SIRe Basic Fan Heaters Water With quick guide. SIReB. For wiring diagram, please see last pages Original instructions

Original instructions. SIRe Basic Quick guide. SIReB

SIRe Competent Fan Heater Electric. SIReFCX. With quick guide. For wiring diagram, please see last pages SE... 2 ES

SIRe Advanced Fan Heater Electric. SIReFAX SIReFAEMX. With quick guide GB DE FR For wiring diagram, please see last pages

SIRe Competent Air Curtains Electric With quick guide. SIReAC. For wiring diagram, please see last pages SE... 2 ES

Original instructions. SIRe Competent Fan Heater Water With quick guide. SIReFC SE For wiring diagram, please see last pages

SIRe Competent Fan heaters Functions. SIReFC

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions

SIRe Advanced Fan Heater - Water. SIReFA SIReFAWM. With quick guide GB DE FR For wiring diagram, please see last pages. ES...

SIRe Advanced Air Curtains Water With quick guide. SIReAA. For wiring diagram, please see last pages SE... 2 ES

SIRe Advanced Air Curtains Water Ambient, no heat

Intelligent Ställer om sig automatiskt efter din entré

Styrsystem SIRe. Intelligent Ställer om sig automatiskt efter din entré. Proaktiv Förutser för snabbare reaktion. Adaptiv Expert på din entré

6. BRUKSANVISNING MILLENIUM PLC

Original instructions. PCER2 Styrenhet med elektronisk termostat

RHOSS IDROWALL Fläktluftkylare/värmare Idrowall MPCB och MPCV

EQ CSE Manual Mikroprocessor

ETO Manual ETO Innehåll

Instruktionsmanual HA27

Roth Basicline 230T. Living full of energy. Installation - snabbguide 1/9

Bruksanvisning Varmkanalstyrning KT300S

EVCO Instrumentbeskrivning EVK204 med HACCP-larm och energisparläge

ANVÄNDARMANUAL. Trådlös fjärrkontroll YB1FA SVENSKA. Drift- och skötselmanual Fjärrkontroll YB1FA

Funktionsguide GOLD version E/F, SMART Link DX

6. BRUKSANVISNING MILLENIUM PLC

CLIMA CANAL HYBRID CLIMA CANAL

3. ANVÄNDNING. 3.1 Princip

Funktionsguide GOLD version E/F, SMART Link DX

CLEVER CONTROL INSTALLATION, DRIFT OCH SKÖTSEL

Handledning SFZ 114. Med servicejournal. VTK Transportkyla

Wired Remote Control MWR-WE10 MANUAL. Trådbunden Fjärrkontroll MWR-WE D99328R0 1/20

Manual HIO-050 MW5. Adress Amerikavägen KALMAR, Sweden. Telefon +46(0) Telefax +46(0)

Användarmanual FlexiSwitch/FlexiSwitchRF

LUFTVÄRMARE, ELEKTRISK FÖR 3X400 V OCH 3X440 V

IPX5. Innehållsförteckning

Bruksanvisning Operatörspanel ER-ipx12

TERMOMAT. Solvärmeautomatik TM 5 G5 MONTERINGS- OCH BRUKSANVISNING

Instruktion styrutrustning för luftvärmare

Regleröversikt. Luftridåer - Reglering. Eveco I Tel I Fax I www. eveco.se SM DM RC2 DA. Manuell. Manuell.

Programmerings & Användarmanual Smile VDS

INSTALLATIONS- ANVISNING

ÅF-manual för styrsystem 3002 till kamin Tyr.

Original instructions. PCR2 Styrenhet med elektronisk termostat

Fläktluftvärmare SWH. Fläktluftvärmare SWH. Intelligent fläktluftvärmare med extremt låg ljudnivå, för vattenanslutning.

LEK. Rumsenhet RMU 40 IHB XC

Fresh TPC. Styrenhet med Touch display Installationsmanual. Installationsmanual


CLEVER CONTROL INSTALLATION, DRIFT OCH SKÖTSEL

JUSTONE MANUAL ÅTERFÖRSÄLJARE

EVCO instrumentbeskrivning EVK242

INSTRUKTIONER FÖR FJÄRRKONTROLL WI-9, WI-12, WI-18, WI-24

LUFTKONDITIONERING VÄRMEPUMP Manual Fjärrkontroll Typ MRW-TH01 och MRW-TH00

Rotronic CP11 CO2-logger


FELSÖKNING MICROMAX OCH VVX-MOTORER

EVCO Instrumentbeskrivning EVK203 (ersätter FK203T)

ETO Manual ETO Innehåll

EVCO Instrumentbeskrivning EVK201 (ersätter FK200X)

Smile Monitor & Ref & Programmerings & Användarmanual

ETANOLDAX Avancerad E85 konverterings modul. Användar manual Gäller för firmware 1.1 ( Rev.2SE)

Instruktion Basketboll

SmartDial. Trådlöst. Användarhandbok. -se. Dokument översatt från engelska A001

Användar-manual. Styrenhet SM-SS-F

LUFTKONDITIONERING VÄRMEPUMP Manual Trådlös Fjärrkontroll Typ MR-CH01

Manual Separat reläutgång för varje kanal.

Installationsmanual Multiläsare 2000 användare 12V DC Revidering 1.00

something new in the air E4T643

EVCO Instrumentbeskrivning EVK203 (ersätter FK203T)

Monterings- och skötselanvisning för luftavfuktare LAV-15D

Styrutrustning. Climatix. Instruktion till snabbmeny

T7560 Digitala Rumsenheter till EXCEL 10

Invest Living Basic 3.1

Användarmanual FlexiSwitch/FlexiSwitchRF

THERMOMATIC EC HOME. Trådlös rumsgivare - Installations- och Bruksanvisning

Bruksanvisning IMSE Operatörspanel

Installationanvisning, apparatlåda för rökfunktion med spjällmotionering TBLZ GOLD/COMPACT

VENCO ANVÄNDAR HANDBOK. Allmän beskrivning Sid. 2. Inledande anvisningar Sid. 2. Displayenhet Sid Parametrar Sid. 5. Larm och signaler Sid.

Flexit. Automatik & styr. till luftbehandlingsaggregat. ( l/s) Flexit S3X, S4X, S7X Flexit L4X, L7X Flexit S4R, S6R, S7R

AR200 AR200. Infälld luftridå för mindre entréer. 1 Utan värme 3 Elvärme: 3 18 kw 2 Vattenburen värme. Rekommenderad installationshöjd 2,5 m*

CT900LED-BED LS900. Bruksanvisning för DENNA BRUKSANVISNING GÄLLER FÖR MJUKVARUVERSION 1.9. KNOP Rehatek AB

Digitala Kopplingsur DATA Micro+ DATA MICRO 2+

G RDF600 RDF600T RDF600KN. Applikationer. sv Installationsinstruktion Rumsregulator. Applikation väljs med DIP-omkopplare 1 3

Instrumentbeskrivning FK203

SNABBMANUAL FÖR IGÅNGKÖRNING AV BOXFAN

Uponor Smatrix Wave PLUS Quick Manual

EVCO Instrumentbeskrivning EVK241

Bergvärmepump Compress 7000i LW

Roth Touchline. German quality since Bruksanvisning - Kort och lätt 1/8

Genomsnittliga energibehov Inget flödande grundvatten och poolen är täckt minst 20 timmar/dag

DRIFT OCH SKÖTSEL INSTRUKTION RC 18-48

ANVÄNDARHANDBOK. Fjärrkontroll BRC315D7

Om något blir fel i värmepumpen

Användarmenyn. S k r i v d i n k o d...

Original instructions. Control system FC. Standalone level - FC111, FC

Wavin AHC 9000 trådbunden rumstermostat u/nattsänkning

Dokumentnummer: Bruksanvisning. Utgivningsdatum/ Revidering Sida: 1 LUFTKONDITIONERING. Användarhandbok

GreenCon på/av rumstermostat

Transkript:

Original instructions SIRe Basic Fan Heaters Electric With quick guide SIReBX C For wiring diagram, please see last pages.

SE SIRe Basic Fan Heaters Electric Quick guide / Uppstart Kontrollera att alla ingående beståndsdelar finns med (se avsnitt Beståndsdelar). Råd om placering Kontrollenhet SIReUB1 har inbyggd rumstemperaturgivare och monteras lättåtkomlig för användaren. Styrkort Bas SIReB1X monteras i anslutning till värmefläkten. Kablage mellan styrkort Bas SIReB1X och värmefläkt ska utföras för 230V. För sammankoppling av styrkort och kontrollenhet används medföljande modularkablar RJ12 (6p/6c) som finns i olika längder. Längre kablar finns som tillval. Max kabellängder, se avsnitt Tillval. För att undvika att obehöriga kan komma åt kontrollenheten kan denna istället placeras i annat utrymme och en extern rumsgivare SIReRTX (tillval) monteras i lokalen för att känna av rätt temperatur. Max kabellängder, se avsnitt Tillval. Interngivare SIReIT02 ska monteras i utloppet på värmefläkten i avsedd hållare. Ställ in ID/Drift utan kontrollenhet Reglersystemet kan styra ett eller flera aggregat parallellt (max 9 stycken). Varje aggregat måste få ett unikt ID-nummer (1-9) som ställs in på ID-väljaren på styrkortet. Ex. Aggregat-1: ID=1, aggregat-2: ID=3 Om den externa regleringen av någon anledning inte har installerats kan aggregatet temporärt ändå köras. ID-väljaren ställs då i läge 0, se bild nedan. Funktionen blir halvfart och halv värmeeffekt När ID-nummer ska ändras ska aggregatet vara spänningslöst. 2 1 0 3 4 5 Varje aggregat ska ha ett unikt ID på sitt SIReB1X-kort. 6 7 2 8 1 9 0 3 4 5 För att temporärt köra aggregat utan extern reglering väljs läge 0. 6 7 8 9 Koppla ihop systemet I Styrkort Bas SIReB1X kopplas även aggregatet vidare med modularkabel RJ12 (6p/6c)om flera aggregat ska vara parallellkopplade. Om en extern rumstemperaturgivare SIReRTX (tillval) ska användas, kopplas den in med modularkabel RJ11 (4p/4c) på styrkort Bas SIReB1X. Styrkort Bas SIReB1X i/vid aggregatet och kontrollenhet SIReUB1 kopplas ihop med modularkabel RJ12 (6p/6c) sist när alla aggregat är spänningssatta. Separat kraftmatning för elvärme ansluts till aggregat (se manual för värmefläkt). Kopplingsschema Kopplingsscheman finns i separat del längst bak i denna manual. 2

SIRe Basic Fan Heaters Electric SE Uppstart Spänningsätt systemet. I statusfönstret visas kort tre siffror t.ex. 1.4.0. vilket är mjukvaruversionen och sedan tre horisontella streck under ca 30 sekunder och därefter rådande rumstemperatur. Vid första uppstarten görs grundläggande inställningar. Tryck pil upp/ner och ställ in önskad temperatur, vilket fläktläge och vilket värmesteg som ska gälla. För att ändra värde tryck på den runda knappen (bekräfta), visningsvärdet börjar blinka och kan nu justeras med pil upp/ner. Förinställt driftläge innebär att fläkten styrs manuellt och värmen styrs av termostat. För ytterligare driftlägen, se avsnitt Driftlägen. Vid första uppstart kan larm och felkoder förekomma, dessa kan normalt återställas utan åtgärd, vid återkommande larm, se avsnitt Larm och felkoder. Fläktsteg Värmesteg SE06-15 4 2 SE20 2 2 SE30 2 3 Välj önskad rumstemperatur 5 - +30 C Välj fläktsteg 1-5 Aktivera värme 0 = Ingen värme 1 = värmesteg 1 möjlig 2 = värmesteg 2 möjlig (3 = värmesteg 3 möjlig) (styrs av termostat) C 20-3 _ 2 3

SE SIRe Basic Fan Heaters Electric Innehåll Quick guide / Uppstart Råd om placering 2 Koppla ihop systemet 2 Kopplingsschema 2 Ställ in ID/Drift utan kontrollenhet 2 Uppstart 3 Beståndsdelar SIReBX 5 Tillval 6 Max kabellängder 6 Driftlägen Driftlägen 7 Eftergång 7 Värmereglering 7 Inställda värden 7 System PÅ/AV 7 Kontrollenhet SIReUB1 Översikt 8 Installatörsmeny Parametermeny 9 Förklaring parametrar 9 Larm och felkoder Överhettningsskydd 10 Visning av larm och felkod 10 Återställning larm 10 Kopplingsschema, se sista sidorna 4

C SIRe Basic Fan Heaters Electric SE Beståndsdelar SIReBX SIReUB1, kontrollenhet Basic Dostäckarlock SIReB1X, styrkort bas SIReIT02, intern temperaturgivare SIReCC, modularkablar Dimensioner beståndsdelar Typ Benämning HxBxD [mm] L [m] SIReUB1 Kontrollenhet 120x70x35 SIRB1X Externt styrkort Bas 202x139x50 SIReIT02 Intern temperaturgivare 2 SIReCC605 Modularkabel RJ12 (6/6) 5 5

SE SIRe Basic Fan Heaters Electric Tillval SIReRTX, extern rumstemperaturgivare SIReCJ4, skarvstycke SIReCJ6, skarvstycke SIReCC, modularkabel Typ RSK-nr E-nr Beskrivning HxBxD [mm] L [m] SIReRTX 673 09 22 87 510 12 Extern rumstemperaturgivare 70x33x23 10 SIReCJ4 Skarvstycke för två st. RJ11 (4/4) SIReCJ6 Skarvstycke för två st. RJ12 (6/6) SIReCC603 673 09 23 87 510 13 Modularkabel RJ12 (6/6) 3 SIReCC605 673 09 24 87 510 14 Modularkabel RJ12 (6/6) 5 SIReCC610 673 09 25 87 510 15 Modularkabel RJ12 (6/6) 10 SIReCC615 673 09 26 87 510 16 Modularkabel RJ12 (6/6) 15 SIReCC403 673 09 27 87 510 17 Modularkabel RJ11 (4/4) 3 SIReCC405 673 09 28 87 510 18 Modularkabel RJ11 (4/4) 5 SIReCC410 673 09 29 87 510 19 Modularkabel RJ11 (4/4) 10 SIReCC415 673 09 30 87 510 20 Modularkabel RJ11 (4/4) 15 Max kabellängder Modularkabel RJ12 (6p/6c) mellan SIReUB1 och SIReB1(X): max 50 m. Modularkabel RJ12 (6p/6c) mellan två SIReB1(X): max 50 m. Modularkabel RJ11 (4p/4c) till rumsgivare SIReRTX: max 20 m. Total kabellängd i systemet får vara max 300 m. 6

SIRe Basic Fan Heaters Electric SE Driftlägen Driftlägen I fabriksinställning går fläkten kontinuerligt på valt fläktsteg och termostaten styr värmen i valda steg. Fläktsteg SE06-15 4 2 SE20 2 2 SE30 2 3 Värmesteg Inställda värden Tryck Pil Upp eller Ner för att välja att ställa in temperatur, fläktsteg och möjliga värmesteg. Tryck på Bekräftaknappen så att värdet börjar blinka, du kan nu justera värdet med Pil Upp/Ned, bekräfta med Bekräftaknappen. Autoläge Genom att ställa om Parameter P04 från 0 till 1 (se parametermenyer nästa sida) kan Autoläge aktiveras. Termostaten styr då både fläkt och värme parallellt. Manuellt läge Om temperaturinställningen ställs ner under 5 C visas följande symbol i statusfönstret I detta läge styrs inkoppling av både fläktoch värmesteg manuellt. Temperatur C 20 Fläktsteg - 3 Värmesteg _ 2 Eftergång Då värmen varit på kommer fläktar fortsätta att gå för eftergång för att på så sätt kyla ner aggregatet. Eftergångstiden är 180 sekunder eller kortare om interntemperaturen sjunker under +30 C(gäller endast aggregat med interntemperaturgivare). Värmereglering Då rumstemperaturen underskrider inställt börvärde kopplas första värmesteget in. Fortsätter temperaturen att sjunka kommer ytterligare värmesteg att kopplas in (se beskrivning under parametrar P.00). System PÅ/AV Tryck och håll in, PÅ / AV-knappen, i 2 sek för att stänga av eller slå på anläggningen. I AV släcks displayen. Alla funktioner som har med aggregatets säkerhet att göra är fortfarande aktiva även när systemet stängs av, vilket innebär att fläkten kan fortsätta att gå en tid även efter avstängning. 7

SE SIRe Basic Fan Heaters Electric Kontrollenhet SIReUB1 Översikt Pil upp Stega uppåt Pil ned Stega nedåt C Statusfönster Bekräfta C Verklig rumstemperatur (ärvärde) 208. Önskad rumstemperatur (börvärde) 20 Alarm Röd diod Drift Grön diod Fläktsteg - 3 PÅ/AV knapp Förklaringar Statusfönster Statusfönstret har fyra grundvisningar: verklig och önskad rumstemperatur, fläkt- och värmesteg. Dessutom visas larmkoder och parameterinställningar. Värmesteg _ 2 Pil Upp Bläddra uppåt i menyn samt öka ett värde. Pil Ned Bläddra nedåt i menyn samt minska ett värde Bekräfta Används för att gå in Installatörsmenyn, välja parameter och bekräfta ett ändrat värde. Efter cirka 20 sek går kontrollenheten tillbaka till visningsläge, aktuell temperatur. 8

SIRe Basic Fan Heaters Electric SE Installatörsmeny Parametermeny Tryck och håll in Bekräftaknappen tills Statusfönstret växlar till P00. Tryck pil Upp/ Ned för att bläddra mellan parametrarna. Tryck kort på Bekräftaknappen för att gå in och ändra ett värde i menyn. Blinkande värden kan justeras med Pil Upp/Ned. Bekräfta med Bekräftaknappen. Tryck och håll in Bekräftaknappen för att återgå till visningsläge (visningsläge går annars tillbaka automatiskt efter ca 50 sekunder). P00. P01. P02. P02.. P13. Förklaring parametrar P.00 Temperaturdifferens elvärmesteg Ställer differensen mellan värmestegen. Fabriksinställning på 1,0 och ett börvärde på 20 C ger följande funktion: lågeffektsteg går in vid +19,5 C (slår ifrån vid +20,0 C) Om temperaturen däremot fortsätter att sjunka under +18,5 C går ytterligare ett effektsteg in (slår ifrån vid +19,0 C), o.s.v P.01 Överhettningslarm På/Av Möjlighet att blockera överhettningslarmet. Gäller endast aggregat med interntemperaturgivare. OBS! Om larmfunktion blockeras måste det säkerställas att detta inte påverkar aggregatets säkerhet. P.02 Eftergångstid Tiden som fläkten fortsätter blåsa efter att värmen varit på (Gäller endast aggregat med interntemperaturgivare) P.03 Temperaturgräns för eftergång Regleringen stoppar eftergångsdriften i förtid om interntemperaturen sjunker under detta värde (Gäller endast aggregat med interntemperaturgivare) P.04 Fläktstyrning Välj driftläge, manuell (0) eller auto (1), se vidare rubrik: Driftlägen P.05 Interntemperatur Visar aktuell interntemperatur. Vid parallellkoppling av flera aggregat visas endast den högsta temperaturen (Gäller endast aggregat med interntemperaturgivare) P.06 - P.13 Drifttid Visar drifttiden för fläkt och värmesteg. Parameterlista Parameternummer Beskrivning Inställningsområde Fabriksinställning P.0 0 Temperaturdifferens mellan värmesteg 0,5-10 1.0 C P.01 Överhettningslarm på/av På=1; Av=0 1/0 1 P.02 Eftergångstid efter att värmen har varit på 10-300 180 sekunder P.03 Temperaturgräns för eftergång 10-40 30 C P.04 Fläktstyrning: Manuell eller Auto; 0=Manuell, 1 = Auto 0/1 0 P.05 Visar aggregatets interntemperatur/utblåstemperatur 0-100 P.06 Drifttid fläktsteg 1 0-99999 P.07 Drifttid fläktsteg 2 0-99999 P.08 Drifttid fläktsteg 3 0-99999 P.09 Drifttid fläktsteg 4 0-99999 P.10 Drifttid fläktsteg 5 0-99999 P.11 Drifttid värmesteg 1 0-99999 P.12 Drifttid värmesteg 2 0-99999 P.13 Drifttid värmesteg 1+2 0-99999 9

SE SIRe Basic Fan Heaters Electric Larm och felkoder Överhettningsskydd SE06-15: Överhettningsskyddet avser att begränsa utblåsningstemperaturen till +70 C. Vid +70 C bryts ett effektsteg bort. Om temperaturen fortsätter stiga bryts all effekt vid +75 C. Skulle temperaturen fortsätta att stiga trots detta, t.ex. vid felaktig kontaktor, så kommer fläkten att börja varva upp vid +70 C för att hålla nere temperaturen. Vid interntemperatur +80 C går fläkten på maximalt varvtal och samtidigt ges ett överhettningslarm, se Tabell - Larm. Om aggregatet svalnar kopplas effekten in igen. Sker däremot två överhettningar inom en timme så måste larmet återställas för att värmen ska kunna kopplas in igen. Fläkten kommer då att vara i drift tills dess att larmet är återställt. SE20-30: Överhettningsskyddet avser att begränsa utblåsningstemperaturen till +85 C. Vid +85 C bryts ett effektsteg bort. Om temperaturen fortsätter stiga bryts all effekt vid +90 C. Skulle temperaturen fortsätta att stiga trots detta, t.ex. vid felaktig kontaktor, så kommer fläkten att börja varva upp vid +85 C för att hålla nere temperaturen. Vid interntemperatur +95 C går fläkten på maximalt varvtal och samtidigt ges ett överhettningslarm, se Tabell - Larm. Om aggregatet svalnar kopplas effekten in igen. Sker däremot två överhettningar inom en timme så måste larmet återställas för att värmen ska kunna kopplas in igen. Fläkten kommer då att vara i drift tills dess att larmet är återställt. OBS! Vid upprepade larm och vid överhettningslarm, gör en noggrann kontroll och om felorsaken inte kan hittas ta kontakt med Frico. Visning av larm och felkod I händelse av larm eller fel visas larm/felkod i statusfönstret. Se Tabell - Larm och Tabell - Felkoder. Statusfönstret växlar mellan att visa nedanstående larm/felkod och vilket aggregat ID som orsakat larmet. Aot. U02. Återställning larm OBS! Innan återställning sker, kontrollera att felet är åtgärdat och att inget hindrar att anläggningen åter tas i drift! Då något av ovanstående larm eller fel indikerats återställs larm enligt beskrivning nedan. Om man trycker på fel knapp försvinner larmindikering i statusfönstret, men återkommer igen efter ca 20 sekunder. Vid första uppstart kan larm och felkoder förekomma, dessa kan normalt återställas utan åtgärd. Larmkoden börjar blinka 3 sek Ert. res. 10

SIRe Basic Fan Heaters Electric SE Tabell - Larm Larm Orsak Åtgärd A.FA Motorlarm A.ot Termokontakt har löst ut. En eller flera motorer överhettade. (Endast aggregat med utdragna termokontakter.) Överhettningslarm Temperaturen i aggregatet har överskridit larmgräns för överhettning. (Endast aggregat med interntemperaturgivare.) Kontrollera att ingenting blockerar aggregatets luftintag och utblås. När den överhettade motorn svalnat sluts termokontakten igen och larmet kan återställas. Vid upprepade larm kontrollera aggregatets motorer. Byt eventuellt trasig motor. Kontrollera att ingenting blockerar aggregatets luftintag och utblås, funktion på kontaktor och interntemperaturgivaren i aggregatet. Tabell - Felkoder Felkod Orsak Åtgärd E.co Kommunikation Styrkortet SIReB1X har ingen kontakt med SIReUB1. Styrkort SIReB1X har inget ID = 0 inställt Två eller flera styrkort har samma ID-nummer. Ett eller flera styrkort är utan program. E.cF ID-fel Två eller flera styrkort i systemet har olika program. Kontrollera anslutning mellan SIReB1X och SIReUB1. Byt ev. modularkabel. Bryt strömmen och välj olika ID-nummer på alla styrkort i systemet. Bryt strömmen och välj olika ID-nummer på alla styrkort i systemet. Kontakta Frico för support. Kontakta Frico för support. E.rt Rumsgivarfel Fel på eller saknad extern rumsgivare SIReRTX kopplad till styrkort SIReB1X. E.lt Interngivarfel Fel på eller saknad interngivare i aggregatet (gäller endast aggregat med interngivare). E.ru Rumsgivarfell Fel på den interna rumsgivaren i kontrollenheten SIReUB1. Bryt alltid strömmen vid i och urkoppling av givare. Kontrollera anslutning av givaren. Kontrollera anslutning av givaren. Om ingen interngivare finns kontakta Frico. Kontrollera anslutningen mellan SIReUB1 och styrkort SIReB1X. Byt ev. modularkabel. Testa om systemet fungerar med en extern givare SIReRTX. Om felet inte går att avhjälpa måste SIReUB1 bytas ut. 11

SIRe Basic Fan Heaters Electric Connections between SIReB1X and Panther SE06, SE09, SE12 and SE15. L L~ N SIReB1X SE06-15 40

SIRe Basic Fan Heaters Electric Connections between SIReB1X and Panther SE20 L L~ N SIReB1X SE20 41

SIRe Basic Fan Heaters Electric Connections between SIReB1X and Panther SE30 L L~ N SIReB1X SE30 42

SIRe Basic Fan Heaters Electric SIReB1X Pot. Unit ID C2 X5 C1 X4 ROOM X3 N L PE PE N L SIReRTX (optional) SIReUB1 C Wiring diagrams Basic 230V~ 43

Wiring diagram SIRe Basic Fan Heaters Electric Basic parallel SIReB1X Pot. Unit ID Pot. Unit ID SIReRTX SIReB1 Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L~ L PE N L SIReUB1 C SIReB1 Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L~ L PE N L 44