BILAGA 2 LIITE 2 Buller- och skuggningsmodellering Melu- ja varjostusmallinnus
Project: Lålax-Lotlax WindPRO version 2.8.579 Dec 212 Printed/Page 8.8.214 15:24 / 1 DECIBEL - Main Result Calculation: Lålax V126 x 5 x HH145 + Lotlax P3 x 3 x HH122 (GF=,4, z=4m, T=15C) Noise calculation model: ISO 9613-2 General Wind speed: 8, m/s Ground attenuation: General, Ground factor:,4 Meteorological coefficient, C:, db Type of demand in calculation: 1: WTG noise is compared to demand (DK, DE, SE, NL etc.) Noise values in calculation: All noise values are mean values (Lwa) (Normal) Pure tones: Pure and Impulse tone penalty are added to WTG source noise Height above ground level, when no value in NSA object: 4, m Don't allow override of model height with height from NSA object Deviation from "official" noise demands. Negative is more restrictive, positive is less restrictive.:, db(a) WTGs New WTG Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 15:1/2.8.579 Scale 1:1 Noise sensitive area BILAGA 2 (1/14) Finish TM ETRS-TM35FIN-ETRS89 WTG type Noise data East North Z Row data/description Valid Manufact. Type-generator Power, Rotor Hub Creator Name Wind Status LwA,ref Pure rated diameter height speed tones [m] [kw] [m] [m] [m/s] [db(a)] 1 256 11 7 15 73 25,8 PROKON P3-116 33 116.7!O!...Yes PROKON P3-116-3 3 3 3 116,7 122, USER Mode - 16,5 db(a) (manufacturer's warranty) 8, 16,5 db h 2 256 56 7 15 928 32,5 PROKON P3-116 33 116.7!O!...Yes PROKON P3-116-3 3 3 3 116,7 122, USER Mode - 16,5 db(a) (manufacturer's warranty) 8, 16,5 db h 3 256 964 7 16 58 29,6 PROKON P3-116 33 116.7!O!...Yes PROKON P3-116-3 3 3 3 116,7 122, USER Mode - 16,5 db(a) (manufacturer's warranty) 8, 16,5 db h 4 26 488 7 12 96 25, VESTAS V126-3.3 GridStreame 33... Yes VESTAS V126-3.3 GridStreame-3 3 3 3 126, 145, EMD Level - - Mode - 8-213 8, From other hub height 17,5 db h 5 26 278 7 13 61 2, VESTAS V126-3.3 GridStreame 33... Yes VESTAS V126-3.3 GridStreame-3 3 3 3 126, 145, EMD Level - - Mode - 8-213 8, From other hub height 17,5 db h 6 26 174 7 14 579 27,5 VESTAS V126-3.3 GridStreame 33... Yes VESTAS V126-3.3 GridStreame-3 3 3 3 126, 145, EMD Level - - Mode - 8-213 8, From other hub height 17,5 db h 7 26 216 7 15 429 2, VESTAS V126-3.3 GridStreame 33... Yes VESTAS V126-3.3 GridStreame-3 3 3 3 126, 145, EMD Level - - Mode - 8-213 8, From other hub height 17,5 db h 8 259 924 7 15 937 27,5 VESTAS V126-3.3 GridStreame 33... Yes VESTAS V126-3.3 GridStreame-3 3 3 3 126, 145, EMD Level - - Mode - 8-213 8, From other hub height 17,5 db h h) Generic octave distribution used Calculation Results Sound Level Noise sensitive area Finish TM ETRS-TM35FIN-ETRS89 Demands Sound Level Demands fulfilled? No. Name East North Z Imission height Noise From WTGs Noise [m] [m] [db(a)] [db(a)] A Asuinrakennus (Zachris) 26 335 7 16 967 9,3 4, 4, 35,9 Yes B Asuinrakennus (Björkkulla) 261 47 7 16 644 5, 4, 4, 35, Yes C Asuinrakennus (Enges) 261 432 7 15 891 5, 4, 4, 35,5 Yes D Asuinrakennus (Ollus) 261 51 7 15 217 4,5 4, 4, 36,1 Yes E Asuinrakennus (Skog) 261 176 7 14 43 14,7 4, 4, 38,7 Yes F Asuinrakennus (Söder) 261 147 7 13 816 7,8 4, 4, 39,5 Yes G Asuinrakennus (Rönnbade) 261 451 7 12 933 1,3 4, 4, 37,3 Yes H Asuinrakennus (Backman) 259 482 7 12 771 15, 4, 4, 37,7 Yes I Asuinrakennus (Lindfors) 259 425 7 13 8 15, 4, 4, 38,1 Yes J Asuinrakennus (Oling) 259 38 7 13 586 15,2 4, 4, 39, Yes K Asuinrakennus (Blusibacken) 259 157 7 14 7 19, 4, 4, 37,8 Yes L Asuinrakennus (Storkull) 258 781 7 13 981 8,4 4, 4, 35,5 Yes M Asuinrakennus (Lassus) 258 748 7 14 64 7,5 4, 4, 36,1 Yes N Asuinrakennus (Enkan) 258 545 7 14 968 5,9 4, 4, 35,6 Yes O Asuinrakennus (Kållbacka) 258 572 7 15 423 5,5 4, 4, 36, Yes P Asuinrakennus (Blusi) 258 61 7 15 953 5, 4, 4, 36, Yes Q Asuinrakennus (Storgård) 258 218 7 16 514 9,5 4, 4, 35, Yes R Asuinrakennus (Källström) 257 963 7 15 259 7,5 4, 4, 35,7 Yes S Asuinrakennus (Söderbacka) 255 349 7 16 363 19,5 4, 4, 36,6 Yes WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax WindPRO version 2.8.579 Dec 212 Printed/Page 8.8.214 15:24 / 2 DECIBEL - Main Result Calculation: Lålax V126 x 5 x HH145 + Lotlax P3 x 3 x HH122 (GF=,4, z=4m, T=15C) Distances (m) WTG NSA 1 2 3 4 5 6 7 8 A 448 3913 3489 461 3365 2392 1542 118 B 527 4541 4122 3777 3137 2241 1471 1326 C 533 4869 4468 3128 2562 1816 13 158 D 5421 4988 4611 2522 225 1471 131 1732 E 5235 485 4513 1671 1221 112 1385 1958 F 5393 546 4742 1123 894 1235 1861 2446 G 634 5732 5465 963 135 283 2784 3368 H 449 4299 4138 114 1149 1935 2756 3195 I 4294 488 3917 167 138 174 2546 297 J 3915 3663 3454 1299 898 1271 222 2411 K 356 3228 31 1726 1192 1167 1772 276 L 3198 2952 2758 216 1543 1515 237 2264 M 2861 2538 2278 2455 1848 1426 1666 175 N 2558 223 1919 2831 226 1674 1732 1684 O 2488 273 1728 3161 2494 181 1643 1446 P 258 239 1639 3582 2887 288 1697 1323 Q 2256 1757 1333 426 3566 275 2273 18 R 1919 1553 1278 3449 2846 2312 2258 274 S 982 1286 1642 619 5646 5141 4953 4592 BILAGA 2 (2/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 15:1/2.8.579 WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax WindPRO version 2.8.579 Dec 212 Printed/Page 8.8.214 15:24 / 3 DECIBEL - Assumptions for noise calculation Calculation: Lålax V126 x 5 x HH145 + Lotlax P3 x 3 x HH122 (GF=,4, z=4m, T=15C) Noise calculation model: ISO 9613-2 General Wind speed: 8, m/s Ground attenuation: General, Ground factor:,4 Meteorological coefficient, C:, db Type of demand in calculation: 1: WTG noise is compared to demand (DK, DE, SE, NL etc.) Noise values in calculation: All noise values are mean values (Lwa) (Normal) Pure tones: Pure and Impulse tone penalty are added to WTG source noise Height above ground level, when no value in NSA object: 4, m Don't allow override of model height with height from NSA object Deviation from "official" noise demands. Negative is more restrictive, positive is less restrictive.:, db(a) Octave data required Air absorption 63 125 25 5 1 2 4 8 [db/km] [db/km] [db/km] [db/km] [db/km] [db/km] [db/km] [db/km],1,4 1,1 2,4 4,1 8,8 26,6 95, BILAGA 2 (3/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 15:1/2.8.579 WTG: PROKON P3-116 33 116.7!O! Noise: Mode - 16,5 db(a) (manufacturer's warranty) Source Source/Date Creator Edited PROKON 2.2.212 USER 7.3.213 17:44 Octave data Status Wind speed LwA,ref Pure tones 63 125 25 5 1 2 4 8 [m/s] [db(a)] [db] [db] [db] [db] [db] [db] [db] [db] From Windcat 8, 16,5 No Generic data 88,1 95,1 98,5 11,1 1,9 98, 93,2 83,7 WTG: VESTAS V126-3.3 GridStreame 33 126.!O! Noise: Level - - Mode - 8-213 Source Source/Date Creator Edited Manufacturer 22.8.213 EMD 17.1.214 9:51 Based on Document no.: 34-7616 V7 213-8-22. Octave data Status Hub height Wind speed LwA,ref Pure tones 63 125 25 5 1 2 4 8 [m] [m/s] [db(a)] [db] [db] [db] [db] [db] [db] [db] [db] From other hub height 145, 8, 17,5 No Generic data 89,1 96,1 99,5 12,1 11,9 99, 94,2 84,7 WTG: VESTAS V126-3.3 GridStreame 33 126.!O! Noise: Level - - Mode - 8-213 Source Source/Date Creator Edited Manufacturer 22.8.213 EMD 17.1.214 9:51 Based on Document no.: 34-7616 V7 213-8-22. Octave data Status Hub height Wind speed LwA,ref Pure tones 63 125 25 5 1 2 4 8 [m] [m/s] [db(a)] [db] [db] [db] [db] [db] [db] [db] [db] From other hub height 145, 8, 17,5 No Generic data 89,1 96,1 99,5 12,1 11,9 99, 94,2 84,7 NSA: Asuinrakennus (Zachris)-A Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax WindPRO version 2.8.579 Dec 212 Printed/Page 8.8.214 15:24 / 4 DECIBEL - Assumptions for noise calculation Calculation: Lålax V126 x 5 x HH145 + Lotlax P3 x 3 x HH122 (GF=,4, z=4m, T=15C) NSA: Asuinrakennus (Björkkulla)-B Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Enges)-C Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Ollus)-D Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Skog)-E Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Söder)-F Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Rönnbade)-G Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Backman)-H Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Lindfors)-I Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Oling)-J Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: BILAGA 2 (4/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 15:1/2.8.579 WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax WindPRO version 2.8.579 Dec 212 Printed/Page 8.8.214 15:24 / 5 DECIBEL - Assumptions for noise calculation Calculation: Lålax V126 x 5 x HH145 + Lotlax P3 x 3 x HH122 (GF=,4, z=4m, T=15C) NSA: Asuinrakennus (Blusibacken)-K Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Storkull)-L Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Lassus)-M Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Enkan)-N Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Kållbacka)-O Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Blusi)-P Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Storgård)-Q Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Källström)-R Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: NSA: Asuinrakennus (Söderbacka)-S Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 4, db(a) Distance demand: BILAGA 2 (5/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 15:1/2.8.579 WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax WindPRO version 2.8.579 Dec 212 Printed/Page 8.8.214 15:24 / 6 DECIBEL - Map 8, m/s Calculation: Lålax V126 x 5 x HH145 + Lotlax P3 x 3 x HH122 (GF=,4, z=4m, T=15C) BILAGA 2 (6/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 15:1/2.8.579 Noise [db(a)] 35 4 45 5 1 15 2 m Map: Peruskartat, Print scale 1:4, Map center Finish TM ETRS-TM35FIN-ETRS89 East: 258 295 North: 7 14 482 New WTG Noise sensitive area Noise calculation model: ISO 9613-2 General. Wind speed: 8, m/s Height above sea level from active line object WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
4 BILAGA 2 (7/14) Lotlax & Lålax vindkraftsprojekt ( ( Layout Lotlax 3 x P3 x HH122 Layout Lålax 5 x N131 x HH145 Byggnader/Klassificering Bostad Fritidsbostad/Jaktstuga Affär/Allmän byggn. Industribyggnad Kyrka, Kyrklig byggnad Bullernivå ISO 9613-2 General (GF=,4, z=4m, T=15C) 35 db(a) 4 db(a) 45 db(a) ( ( ( ( ( ( ( (,45,9 1,35 km 1,8
Project: Lålax-Lotlax SHADOW - Main Result Calculation: Lotlax P3 x 3 x HH122 + Lålax N131 x 5 x HH145 "real case" Assumptions for shadow calculations Maximum distance for influence Calculate only when more than 2 % of sun is covered by the blade Please look in WTG table Minimum sun height over horizon for influence 3 Day step for calculation 1 days Time step for calculation 1 minutes Sunshine probability S (Average daily sunshine hours) [UMEA] Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1,2 2,84 3,78 6,14 8,62 9,94 7,42 5,13 4,32 3,43 1,58,96 Operational hours are calculated from WTGs in calculation and wind distribution: MERRA_basic_E22.2_N63. Operational time N NNE ENE E ESE SSE S SSW WSW W WNW NNW Sum 729 615 484 446 535 72 91 1 278 922 792 589 575 8 567 Idle start wind speed: Cut in wind speed from power curve WindPRO version 2.9.269 Nov 213 Printed/Page 3.1.214 13:25 / 1 BILAGA 2 (8/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 12:2/2.8.579 A ZVI (Zones of Visual Influence) calculation is performed before flicker calculation so non visible WTG do not contribute to calculated flicker values. A WTG will be visible if it is visible from any part of the receiver window. The ZVI calculation is based on the following assumptions: Height contours used: Height Contours: Lålax-Lotlax_height contour lines.wpo (4) Obstacles not used in calculation Eye height: 1,5 m Scale 1:1 Grid resolution: 1, m New WTG Shadow receptor WTGs Finish TM ETRS-TM35FIN-ETRS89 WTG type Shadow data East North Z Row data/description Valid Manufact. Type-generator Power, Rotor Hub Calculation RPM rated diameter height distance [m] [kw] [m] [m] [m] [RPM] 1 26 488 7 12 96 25, NORDEX N131/3 3 131... Yes NORDEX N131/3-3 3 131, 145, 1 721 1,3 2 26 278 7 13 61 2, NORDEX N131/3 3 131... Yes NORDEX N131/3-3 3 131, 145, 1 721 1,3 3 26 174 7 14 579 27,5 NORDEX N131/3 3 131... Yes NORDEX N131/3-3 3 131, 145, 1 721 1,3 4 26 216 7 15 429 2, NORDEX N131/3 3 131... Yes NORDEX N131/3-3 3 131, 145, 1 721 1,3 5 259 924 7 15 937 27,5 NORDEX N131/3 3 131... Yes NORDEX N131/3-3 3 131, 145, 1 721 1,3 6 256 11 7 15 73 25,8 PROKON P3-116 33 116.7... Yes PROKON P3-116-3 3 3 3 116,7 122, 1 819 11,7 7 256 56 7 15 928 32,5 PROKON P3-116 33 116.7... Yes PROKON P3-116-3 3 3 3 116,7 122, 1 819 11,7 8 256 964 7 16 58 29,6 PROKON P3-116 33 116.7... Yes PROKON P3-116-3 3 3 3 116,7 122, 1 819 11,7 Shadow receptor-input Finish TM ETRS-TM35FIN-ETRS89 No. Name East North Z Width Height Height Degrees from Slope of Direction mode a.g.l. south cw window [m] [m] [m] [m] [ ] [ ] A Asuinrakennus (Zachris) 26 335 7 16 967 9,3 5, 5, 1,,, "Green house mode" B Asuinrakennus (Björkkulla) 261 47 7 16 644 5, 5, 5, 1,,, "Green house mode" C Asuinrakennus (Enges) 261 432 7 15 89 5, 5, 5, 1,,, "Green house mode" D Asuinrakennus (Ollus) 261 51 7 15 217 4,5 5, 5, 1,,, "Green house mode" E Asuinrakennus (Skog) 261 175 7 14 43 14,7 5, 5, 1,,, "Green house mode" F Asuinrakennus (Söder) 261 147 7 13 816 7,8 5, 5, 1,,, "Green house mode" G Asuinrakennus (Rönnbade) 261 451 7 12 932 1,3 5, 5, 1,,, "Green house mode" H Asuinrakennus (Backman) 259 482 7 12 771 15, 5, 5, 1,,, "Green house mode" I Asuinrakennus (Lindfors) 259 425 7 13 8 15, 5, 5, 1,,, "Green house mode" J Asuinrakennus (Oling) 259 379 7 13 585 15,2 5, 5, 1,,, "Green house mode" K Asuinrakennus (Blusibacken) 259 158 7 14 7 19,2 5, 5, 1,,, "Green house mode" L Asuinrakennus (Storkull) 258 782 7 13 98 8,4 5, 5, 1,,, "Green house mode" M Asuinrakennus (Lassus) 258 748 7 14 64 7,5 5, 5, 1,,, "Green house mode" N Asuinrakennus (Enkan) 258 545 7 14 968 5,9 5, 5, 1,,, "Green house mode" To be continued on next page... WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax SHADOW - Main Result Calculation: Lotlax P3 x 3 x HH122 + Lålax N131 x 5 x HH145 "real case" WindPRO version 2.9.269 Nov 213 Printed/Page 3.1.214 13:25 / 2 BILAGA 2 (9/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 12:2/2.8.579...continued from previous page Finish TM ETRS-TM35FIN-ETRS89 No. Name East North Z Width Height Height Degrees from Slope of Direction mode a.g.l. south cw window [m] [m] [m] [m] [ ] [ ] O Asuinrakennus (Kållbacka) 258 572 7 15 423 5,5 5, 5, 1,,, "Green house mode" P Asuinrakennus (Blusi) 258 6 7 15 953 5, 5, 5, 1,,, "Green house mode" Q Asuinrakennus (Storgård) 258 217 7 16 513 9,4 5, 5, 1,,, "Green house mode" R Asuinrakennus (Källström) 257 963 7 15 259 7,5 5, 5, 1,,, "Green house mode" S Asuinrakennus (Söderbacka) 255 349 7 16 363 19,5 5, 5, 1,,, "Green house mode" Calculation Results Shadow receptor Shadow, expected values No. Name Shadow hours per year [h/year] A Asuinrakennus (Zachris) 5:24 B Asuinrakennus (Björkkulla) 3:43 C Asuinrakennus (Enges) 3:21 D Asuinrakennus (Ollus) 3:42 E Asuinrakennus (Skog) 13:28 F Asuinrakennus (Söder) 14:52 G Asuinrakennus (Rönnbade) 6:41 H Asuinrakennus (Backman) 4: I Asuinrakennus (Lindfors) 1:42 J Asuinrakennus (Oling) 6:31 K Asuinrakennus (Blusibacken) 11:4 L Asuinrakennus (Storkull) 3:58 M Asuinrakennus (Lassus) 4:28 N Asuinrakennus (Enkan) 6:19 O Asuinrakennus (Kållbacka) 5:7 P Asuinrakennus (Blusi) 4: Q Asuinrakennus (Storgård) 1:38 R Asuinrakennus (Källström) 6:25 S Asuinrakennus (Söderbacka) 4:57 Total amount of flickering on the shadow receptors caused by each WTG No. Name Worst case Expected [h/year] [h/year] 1 NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (21) 86:41 17:5 2 NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (22) 11:58 24:58 3 NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (23) 111:32 27:51 4 NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (24) 9:44 18:53 5 NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (25) 75:25 16:4 6 PROKON P3-116 33 116.7!O! hub: 122, m (TOT: 18,4 m) (26) 13:44 2:45 7 PROKON P3-116 33 116.7!O! hub: 122, m (TOT: 18,4 m) (27) 18:23 3:38 8 PROKON P3-116 33 116.7!O! hub: 122, m (TOT: 18,4 m) (28) 4:25 9:13 WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax SHADOW - Calendar, graphical Calculation: Lotlax P3 x 3 x HH122 + Lålax N131 x 5 x HH145 "real case" WindPRO version 2.9.269 Nov 213 Printed/Page 3.1.214 13:25 / 3 BILAGA 2 (1/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 12:2/2.8.579 A: Asuinrakennus (Zachris) B: Asuinrakennus (Björkkulla) Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec C: Asuinrakennus (Enges) D: Asuinrakennus (Ollus) Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec E: Asuinrakennus (Skog) F: Asuinrakennus (Söder) Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec WTGs 1: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (21) 2: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (22) 3: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (23) 4: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (24) 5: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (25) WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax SHADOW - Calendar, graphical Calculation: Lotlax P3 x 3 x HH122 + Lålax N131 x 5 x HH145 "real case" WindPRO version 2.9.269 Nov 213 Printed/Page 3.1.214 13:25 / 4 BILAGA 2 (11/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 12:2/2.8.579 G: Asuinrakennus (Rönnbade) H: Asuinrakennus (Backman) Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec I: Asuinrakennus (Lindfors) J: Asuinrakennus (Oling) Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec K: Asuinrakennus (Blusibacken) L: Asuinrakennus (Storkull) Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec WTGs 1: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (21) 2: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (22) 3: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (23) WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax SHADOW - Calendar, graphical Calculation: Lotlax P3 x 3 x HH122 + Lålax N131 x 5 x HH145 "real case" WindPRO version 2.9.269 Nov 213 Printed/Page 3.1.214 13:25 / 5 BILAGA 2 (12/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 12:2/2.8.579 M: Asuinrakennus (Lassus) N: Asuinrakennus (Enkan) Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec O: Asuinrakennus (Kållbacka) P: Asuinrakennus (Blusi) Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Q: Asuinrakennus (Storgård) R: Asuinrakennus (Källström) Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec WTGs 3: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (23) 4: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (24) 5: NORDEX N131/3 3 131.!O! hub: 145, m (TOT: 21,5 m) (25) 7: PROKON P3-116 33 116.7!O! hub: 122, m (TOT: 18,4 m) (27) 8: PROKON P3-116 33 116.7!O! hub: 122, m (TOT: 18,4 m) (28) WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
Project: Lålax-Lotlax SHADOW - Calendar, graphical Calculation: Lotlax P3 x 3 x HH122 + Lålax N131 x 5 x HH145 "real case" WindPRO version 2.9.269 Nov 213 Printed/Page 3.1.214 13:25 / 6 BILAGA 2 (13/14) Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 12:2/2.8.579 Time : 23: 22: 21: 2: 19: 18: 17: 16: 15: 14: 13: 12: 11: 1: 9: 8: 7: 6: 5: 4: S: Asuinrakennus (Söderbacka) Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec WTGs 6: PROKON P3-116 33 116.7!O! hub: 122, m (TOT: 18,4 m) (26) 7: PROKON P3-116 33 116.7!O! hub: 122, m (TOT: 18,4 m) (27) 8: PROKON P3-116 33 116.7!O! hub: 122, m (TOT: 18,4 m) (28) WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
BILAGA 2 (14/14) WindPRO version 2.9.269 Nov 213 Project: Printed/Page Lålax-Lotlax 3.1.214 13:25 / 7 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 95 FI-61 Helsinki +3581495666 Paulina Kaivo-oja / paulina.kaivo-oja@fcg.fi Calculated: 8.8.214 12:2/2.8.579 SHADOW - Map Calculation: Lotlax P3 x 3 x HH122 + Lålax N131 x 5 x HH145 "real case" Hours per year, real case 1 h/a 8 h/a 2 h/a 5 1 15 2 m Map: Peruskartat, Print scale 1:5, Map center Finish TM ETRS-TM35FIN-ETRS89 East: 258 225 North: 7 14 863 New WTG Shadow receptor Flicker map level: Height Contours: Lålax-Lotlax_height contour lines.wpo (4) WindPRO is developed by EMD International A/S, Niels Jernesvej 1, DK-922 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk
4 Lotlax & Lålax vindkraftsprojekt ( ( Layout Lotlax 3 x P3 x HH122 Layout Lålax 5 x N131 x HH145 Byggnader/Klassificering Bostad Fritidsbostad/Jaktstuga Affär/Allmän byggn. Industribyggnad Kyrka, Kyrklig byggnad Skuggbildning "real case", totalt h/a 1 h/a 8 h/a ( ( ( 2 h/a ( ( ( ( (,45,9 1,35 km 1,8
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, A Bostad (Zachris),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, B Bostad (Björkkulla),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, C Bostad (Enges),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, D Bostad (Ollus),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, E Bostad (Skog),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, F Bostad (Söder),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, G Bostad (Rönnbade),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, H Bostad (Backman),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, I Bostad (Lindfors),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, J Bostad (Oling),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, K Bostad (Blusibacken),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, L Bostad (Storkull),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, M Bostad (Lassus),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, N Bostad (Enkan),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, O Bostad (Kållbacka),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, P Bostad (Blusi),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, Q Bostad (Storgård),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, R Bostad (Källström),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens oviktade ljudnivå L eq db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Lågfrekvent buller utom- och inomhus,, S Bostad (Söderbacka),, Ljudisolering enligt DSO1284 1 9 8 Ljudnivå ute db Ljudnivå inne db Shv Riktvärde för boendehälsa db Hörseltröskel för låga frekvenser 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 Tersens medelfrekvens, Hz Uppgifter för bostäder och kraftverk framgår av WindPro-raporten: Kraftverk navhöjd st Prokon P3-116 33 116.7 3,3 MW,, 122 m,, 3 Vestas V126-3.3 Gridstreame 33 3,3 MW,, 145 m,, 5 Beräkningen är gjord enligt YM 2/214 "Modellering av buller från vindkraftverk": Ljudet avtar geometriskt från punktutsläppet, markens dämpande effekt enligt DSO1284 och luften absorption enligt ISO9613-1:1996 +15 C 7% RH. C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Laskenta
Tersens bulleremission L WA, db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Prokon P3-116 33 116.7 12 11 1 9 8 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 25 315 4 5 63 8 1 125 16 2 25 315 4 5 63 8 Tersens medelfrekvens, Hz Lwa Inter/extrapolerad av tillverkare anmält värde Tillverkare anmält oktavvärde C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Päästögraafit
Tersens bulleremissionte rs ens bulleremission LWA, db FCG Suunnittelu ja Tekniikka Oy 3.9.214 Vestas V126-3.3 Gridstreame 33 12 11 1 9 8 7 6 5 4 3 2 1 2 25 31,5 4 5 63 8 1 125 16 2 25 315 4 5 63 8 1 125 16 2 25 315 4 5 63 8 Tersens medelfrekvens, Hz Lwa Inter/extrapolerad av tillverkare anmält värde Tillverkare anmält oktavvärde C:\Users\akumah\Documents\_PROJEKTIT_TEMP\Lålax-Lotlax\Matalataajuinen_Lålax5xV126hh145_Lotlax3xP3hh122.xlsm Päästögraafit
Matalataajuisen melun laskenta Raportin ja raportoijan tiedot Raportin laatija FCG Suunnittelu ja tekniikka Oy Satu Projektipäällikkö Taskinen Tarkastaja / hyväksyjä Hyväksytty pvm Laatija Mauno Aho Laadittu pvm 3.9.214 Projektinumero Projektin nimi Asiakas Yhteyshenkilö P19943P5 Lålaxin tuulivoimapuiston osayleiskaava Prokon Wind Energy Finland Oy Mikael Sandberg Mallinnusohjelman tiedot WindPro 2.9.269 Mallinnusohjelma ja versio Mallinnusmenetelmä FCG Matalataajuisen melun laskentataulukko 4.8.214 ISO 9613-2 matalataajuisen melun laskenta YM ohjeen 2/214 mukaisesti Tuulivoimaloiden tiedot Valmistaja Vestas Tyyppi Vestas V126-3.3 Gridstream 33 Sarjanumerot --- Nimellisteho, MW 3,3 Napakork. m 145 Roottorin halkaisija, m 126 Tornin tyyppi teräslieriö Akustiset tiedot / Laskennan lähtötiedot Melupäästötiedot Lähde WindPro generic data 8.8.214 Tyyppi Mode, Generic L WA db 17,5 Arvioitu oktaaveittain Terssitiedot ilmoitetusta datasta Mahdollisuudet vaikuttaa tuulivoimalan melupäästöön käytön aikana ja sen vaikutus meluun Keino Käytettävissä db Lapakulman säätö Pyörimisnopeus Muut Noise Mode (normal) Noise Mode 1 Noise Mode 2 Noise Mode 3 Noise Mode 4 L WA
Ilmoitetut arvot Laskettu Oktaaveittain Tersseittäin Tersseittäin Taajuus Hz L WA db LWA db L W db 2 117,2 25 115,9 31,5 114,5 4 113,2 5 111,9 63 89,1 11,5 8 19,5 1 18,5 125 96,1 17,4 16 16,1 2 14,7 25 99,5 13,3 315 12,4 4 11,5 5 12,1 1,5 63 99,4 8 98,3 1 11,9 97,1 125 95,8 16 94,4 2 99 93, 25 91,5 315 9, 4 94,2 88,4 5 86, 63 83,5 8 84,7 81, 1 78,6 125 76,1 16 73,6 Melun erityispiirteiden mittaus ja havainnot Kapeakaistaisuus Tonaalisuus Impulssimaisuus ei ei ei Merkityksellinen sykintä (Amplitudimodulaatio) -- Muu Akustiset tiedot / Laskennan lähtötiedot parametri arvo selite Laskentakorkeus m 4 Laskentaruutu m n/a Kosteus RH % 7 Lämpötila C 15 ei käytössä matalataajuisen melun laskennassa ei käytössä matalataajuisen melun laskennassa
Maastomallin lähde ja tarkkuus Lähde Vaakaresoluutio Pystyresolutio MML MTK MTK peruskartta 1m ei käytössä matalataajuisen melun laskennassa ei käytössä matalataajuisen melun laskennassa ei käytössä matalataajuisen melun laskennassa Maa- ja vesialueen absorption ja heijastusten huomioiminen, käytetyt kertoimet ISO9613- Laskentamalli 2 Vesialueet ei ole Maa-alueet,4 suota ja peltoa Ilmakehän stabiilisuus Neutraali Sääolosuhteiden huomiointi Tuulensuunta % m/s N ( ) --- --- NE (45 ) --- --- E (9 ) --- --- SE (135 ) --- --- S (18 ) --- --- SW (225 ) --- --- W (27 ) --- --- NW (315 ) --- --- Voimalan äänen suuntaavuus ja vaimentuminen Vapaa Säteilykulma avaruus Melulle altistuvat asukkaat ja kohteet lkm (ilman meluntorjuntaa / voimalan ohjausta) kohde lkm Asukkaat Vakituiset asunnot Vapaa-ajan rakennukset Hoito- ja oppilaitokset Virkistysalueet Luonnonsuojelualueet
Matalataajuisen melun laskenta Raportin ja raportoijan tiedot Projektipäällikkö Satu Taskinen Tarkastaja / hyväksyjä Hyväksytty pvm Laatija Mauno Aho Laadittu pvm 3.9.214 Projektinumero P19943P5 Lålaxin tuulivoimapuiston osayleiskaava (Lotlax Projektin nimi yhteismallinnus) Asiakas Yhteyshenkilö Projektipäällikkö Prokon Wind Energy Finland Oy Mikael Sandberg Satu Taskinen Mallinnusohjelman tiedot Windpro 2.9.269 Mallinnusohjelma ja versio Mallinnusmenetelmä FCG Matalataajuisen melun laskentataulukko 4.8.214 ISO 9613-2 matalataajuisen melun laskenta YM ohjeen 2/214 mukaisesti Tuulivoimaloiden tiedot Valmistaja Prokon Tyyppi Prokon P3-116 33 116.7 Sarjanumerot --- Nimellisteho, MW Napakork. 3,3 m 122 Roottorin halkaisija, m Tornin 116,7 tyyppi teräslieriö Mahdollisuudet vaikuttaa tuulivoimalan melupäästöön käytön aikana ja sen vaikutus meluun Keino Käytettävissä db Lapakulman säätö Pyörimisnopeus Muut Noise Mode (normal) Noise Mode 1 Noise Mode 2 Noise Mode 3 Noise Mode 4 L WA
Akustiset tiedot / Laskennan lähtötiedot Melupäästötiedot Lähde WindPro generic data 2.2.212 Tyyppi Terssitiedot L WA Manufacturer s warranty db 16,5 Arvioitu oktaaveittain ilmoitetusta datasta Ilmoitetut arvot Laskettu Oktaaveittain Tersseittäin Tersseittäin Taajuus Hz L WA db LWA db L W db 2 116,2 25 114,9 31,5 113,5 4 112,2 5 11,9 63 88,1 19,5 8 18,5 1 17,5 125 95,1 16,4 16 15,1 2 13,7 25 98,5 12,3 315 11,4 4 1,5 5 11,1 99,5 63 98,4 8 97,3 1 1,9 96,1 125 94,8 16 93,4 2 98 92, 25 9,5 315 89, 4 93,2 87,4 5 85, 63 82,5 8 83,7 8, 1 77,6 125 75,1 16 72,6 Melun erityispiirteiden mittaus ja havainnot Kapeakaistaisuus Tonaalisuus Impulssimaisuus ei ei ei Merkityksellinen sykintä (Amplitudimodulaatio) -- Muu
Akustiset tiedot / Laskennan lähtötiedot parametri arvo selite Laskentakorkeus m 4 Laskentaruutu m n/a Kosteus RH % 7 Lämpötila C 15 Maastomallin lähde ja tarkkuus Lähde Vaakaresoluutio Pystyresolutio MML MTK MTK peruskartta 1m ei käytössä matalataajuisen melun laskennassa ei käytössä matalataajuisen melun laskennassa ei käytössä matalataajuisen melun laskennassa ei käytössä matalataajuisen melun laskennassa ei käytössä matalataajuisen melun laskennassa Maa- ja vesialueen absorption ja heijastusten huomioiminen, käytetyt kertoimet Laskentamalli ISO9613-2 Vesialueet ei ole Maa-alueet,4 suota ja peltoa Ilmakehän stabiilisuus Neutraali Sääolosuhteiden huomiointi Tuulensuunta % m/s N ( ) --- --- NE (45 ) --- --- E (9 ) --- --- SE (135 ) --- --- S (18 ) --- --- SW (225 ) --- --- W (27 ) --- --- NW (315 ) --- --- Voimalan äänen suuntaavuus ja vaimentuminen Säteilykulma Vapaa avaruus Melulle altistuvat asukkaat ja kohteet lkm (ilman meluntorjuntaa / voimalan ohjausta) kohde lkm Asukkaat Vakituiset asunnot Vapaa-ajan rakennukset Hoito- ja oppilaitokset Virkistysalueet Luonnonsuojelualueet