Installation Instructions

Relevanta dokument
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

BBT057/ BBC057 BBCD057/ BBT057-NL HOLDEN COLORADO 9/2016+ HOLDEN TRAILBLAZER WD & 4WD Models

INSTALLATION INSTRUCTIONS

Windlass Control Panel v1.0.1

SkillGuide. Bruksanvisning. Svenska

Dokumentnamn Order and safety regulations for Hässleholms Kretsloppscenter. Godkänd/ansvarig Gunilla Holmberg. Kretsloppscenter

HANTERING AV UPS CX

Application Note SW

Installation Instructions

Användarhandbok. MHL to HDMI Adapter IM750

RADIATION TEST REPORT. GAMMA: 30.45k, 59.05k, 118.8k/TM1019 Condition D

Beijer Electronics AB 2000, MA00336A,

PROFINET MELLAN EL6631 OCH EK9300

Presenter SNP6000. Register your product and get support at SV Användarhandbok

PFC and EMI filtering

BBT042/ BBC042/ BBCD042 NISSAN NAVARA D40 V STX & PATHFINDER R WD & 4WD Models

Isolda Purchase - EDI

Installation Instructions

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

FÖRSÄKRAD:LIONS CLUB INTERNATIONAL MD 101 FÖRSÄKRINGS NR. 29SE000185

Användarhandbok. USB Charging Dock DK52

ISO STATUS. Prof. dr Vidosav D. MAJSTOROVIĆ 1/14. Mašinski fakultet u Beogradu - PM. Tuesday, December 09,

2.1 Installation of driver using Internet Installation of driver from disk... 3

Installation Instructions

Design Service Goal. Hantering av demonterbara delar som ingår i Fatigue Critical Baseline Structure List. Presentatör

SVENSK STANDARD SS-ISO :2010/Amd 1:2010

H0008 Skrivskydd FBWF

P650 - Takscreen. Installationsguide EN

FÖRBERED UNDERLAG FÖR BEDÖMNING SÅ HÄR

ARC 32. Tvättställsblandare/Basin Mixer. inr.se

Schenker Privpak AB Telefon VAT Nr. SE Schenker ABs ansvarsbestämmelser, identiska med Box 905 Faxnr Säte: Borås

Joki Joki Air. JCD70-xx JAD90-xx. lasiesta.com. Manual. Betriebsanleitung. Manuel. Manual. Manuale. Gebruiksaanwijzing.

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENS LÄS IGENOM INSTRUKTIONSMANUALEN

Instruction Manual. Svenska, English. Power Bank. Model: PRBN

The Municipality of Ystad

Användarhandbok. Xperia P TV Dock DK21

81152 TRANSFER CASE SHIFT HANDLE

SAFETY PRECAUTIONS SPECIFICATIONS

BOW. Art.nr

Teknisk support finns tillgänglig Måndag-Fredag 08:00-16:30. Övrig dokumentation finns tillgänglig på Teletecs hemsida -

Seminarium för CAMO, F-verkstäder, AUB och tekniker med inriktning på privat-, skol- och bruksflyg 2017 B1 versus B2 Jukka Salo Flygteknisk inspektör

MAC Ope ra tor Terminal

Viktig information för transmittrar med option /A1 Gold-Plated Diaphragm

Användarhandbok. USB Charger UCH20

District Application for Partnership

Support Manual HoistLocatel Electronic Locks

BBT014/ BBC014/ BBCD014 PJ & PK FORD RANGER WD & 4WD Models

Materialplanering och styrning på grundnivå. 7,5 högskolepoäng

Magnetic Charging Dock DK48

Fortsatt Luftvärdighet

VASSVIK FIXED STAND SE / ENG

Angående erhållande av behörighet som fartygselektriker

Boiler with heatpump / Värmepumpsberedare

SAFETY PRECAUTIONS SPECIFICATIONS

Introduktion ICAO-EASA.

InstalationGuide. English. MODEL:150NHighGain/30NMiniUSBAdapter

Adress 15. August 2014

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENSLÄS IGENOM INSTRUKTIONSMANUALEN NOGGRANT

Läkemedelsverkets Farmakovigilansdag

säkerhetsutrustning / SAFETY EQUIPMENT

DC-DC CONVERTER IP67


Utveckling på kort sikt ererfrågan

Får endast utföras av behörig personal. May only be carried out by authorized electrician

LINC 23. Tvättställsblandare/Basin Mixer. inr.se A

Swedish adaptation of ISO TC 211 Quality principles. Erik Stenborg

Komponenter Removed Serviceable


Michael Q. Jones & Matt B. Pedersen University of Nevada Las Vegas

Quick Start Guide Snabbguide

PORTSECURITY IN SÖLVESBORG

Taxning och motorkörning av flygplan/helikopter

DC-DC CONVERTER ISOLATED

Instruktioner. Säkerhetsföreskrifter. Förklaringar av symboler

SVENSK STANDARD SS-EN ISO :2009/AC:2010

Bathtub Filler CN EN. TBP02201 Type / TBP02202 Type. Installation Manual. Continued on the back cover

VH110 Användarhandbok

Custom-made software solutions for increased transport quality and creation of cargo specific lashing protocols.

BEAM. Product Manual Produktmanual

E terminals, Installation E terminals, Manual. Manual IFC 128E. Beijer Electronics AB 2000

SVENSK STANDARD SS-EN 13612/AC:2016

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK

LINC MODELL 13. INR SVERIGE AB Kosterögatan 15 SE Malmö 13 EN 1428:2005+A1:2008

Röntgenutrustningar - säkerhetsaspekter

SVENSK STANDARD SS-EN ISO 14534

STANDARD. UTM Ingegerd Annergren UTMS Lina Orbéus. UTMD Anders Johansson UTMS Jan Sandberg

Your No. 1 Workout. MANUAL pro

Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

Alias 1.0 Rollbaserad inloggning

Discovery FSQ, IAA Utgåva/Edition 11. SE Habo. Klass 2 IAA FSQ-I 26W. 4 mm c c mm N L

Monteringsanvisning Nödutrymningsbeslag ASSA 179E

Schenker Privpak AB Telefon VAT Nr. SE Schenker ABs ansvarsbestämmelser, identiska med Box 905 Faxnr Säte: Borås

Fiat » Fiat Panda / 4x4 2003» Fiat Panda 4x4 Climbing / 4x4 Cross 20033»

SVENSK STANDARD SS-EN

FORTA M315. Installation. 218 mm.

INTERAKTIVA UTBILDNINGAR. UPPDRAG: Trafikutbildning åt Örebro kommun. KUND: Agresso Unit4

Transkript:

Installation Instructions Cat. No. 1771-ID16 Series B Use this document as a guide when installing the ac Isolated Input module. This module must be used in a series B or later 1771 I/O chassis. The 1771-ID16 is not compatible with the 1771-AL local I/O adapter. This module contains customer-selectable input filtering to limit the effects of voltage transients caused by contact bounce and/or radiated electrical noise. The delay due to filtering is 9.0 or 18.0ms for turning ac inputs on to off, and 0.57ms for turning ac inputs off to on: 9.0ms for turning dc inputs on to off, and 0.57ms for turning dc inputs off to on. The filter time is factory set to 9.0ms. The module is designed to operate with limit switches, float switches, selector switches, and pushbutton switches.

2 ac/dc (120V) Isolated Input Module Because of the variety of uses for the products described in this publication, those responsible for the application and use of these products must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. In no event will Rockwell Automation be responsible or liable for indirect or consequential damage resulting from the use or application of these products. Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication. Allen Bradley publication SGI 1.1, Safety Guidelines for Application, Installation, and Maintenance of Solid State Control (available from your local Rockwell Automation office), describes some important differences between solid state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication. Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited. Throughout this publication, notes may be used to make you aware of safety considerations. The following annotations and their accompanying statements help you to identify a potential hazard, avoid a potential hazard, and recognize the consequences of a potential hazard. WARNING Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION Identifies information about practices or circumstances that may lead to personal injury or death, property damage, or economic loss.

ac/dc (120V) Isolated Input Module 3 IMPORTANT Identifies information that is critical for successful application and understanding of the product. ATTENTION This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC publication 60664 1), at altitudes up to 2000 meters without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR Publication 11. Without appropriate precautions, there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance. This equipment is supplied as open type equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present, and appropriately designed to prevent personal injury resulting from accessibility to live parts. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. See NEMA Standards publication 250 and IEC publication 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosures. Also, see the appropriate sections in this publication, as well as the Allen Bradley publication 1770 4.1, ( Industrial Automation Wiring and Grounding Guidelines ), for additional installation requirements pertaining to this equipment.

4 ac/dc (120V) Isolated Input Module The isolated input module is shipped in a static-shielded packaging to guard against electrostatic discharge damage. Observe the following precautions when handling the module. ATTENTION This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: Touch a grounded object to discharge potential static. Wear an approved grounding wriststrap. Do not touch connectors or pins on component boards. Do not touch circuit components inside the equipment. If available, use a static safe workstation. When not in use, keep modules in appropriate static safe packaging. Your module receives its power through the 1771 I/O chassis backplane from the chassis power supply. The module requires 75mA from the output of this supply. Add this to the requirements of all other modules in the I/O chassis to prevent overloading the chassis backplane and/or backplane power supply. The input module has 2 customer-selectable input filter time jumpers. Jumper JPR 1 sets the input filter time for inputs 00 through 07, and jumper JPR 2 sets the input filter time for inputs 10 through 17. These filter times apply when the input is cycling from ON to OFF. The OFF to ON filter time is fixed at 0.57ms. Refer to Table A for filter times and jumper settings. IMPORTANT Half cycle dropout protection is dependent upon the position of the jumpers. With the jumpers at the 9.0ms position (Fast), half cycle protection may not be guaranteed. If half cycle dropout protection is required, position the jumpers in the 18.0ms position (Norm). Maximum and minimum filter times are shown in Table A.

ac/dc (120V) Isolated Input Module 5 To set the filtering time, proceed as follows: 1. Remove the side covers from the module circuit board by removing the four screws securing the covers to the module and remove the circuit board. 2. Position the jumpers as required to provide the filter time you require (see below). Use your fingers to pull the jumper up and position over the 2 pins corresponding to your selection (Fast or Norm). Setting the Filter Time Jumpers 3. Reinstall the covers on the module circuit board and secure with 4 screws.

6 ac/dc (120V) Isolated Input Module Place your module in any slot in the chassis except the leftmost slot which is reserved for processors or adapters. ATTENTION Observe the following precautions when inserting or removing keys: insert or remove keys with your fingers make sure that key placement is correct Incorrect keying or the use of a tool can result in damage to the backplane connector and possible system faults. ATTENTION Remove power from the 1771 I/O chassis backplane before you install the module. Failure to remove power from the backplane could cause: module damage degradation of performance injury or equipment damage due to possible unexpected operation WARNING When you insert or remove the module with field power applied, or connect or disconnect the field wiring arm with field side power applied, an electrical arc can occur. This could cause an explosion in hazardous location installations.be sure that power is removed or the area is nonhazardous before proceeding.

ac/dc (120V) Isolated Input Module 7 The 1771 ID16/B module is a modular component of the 1771 I/O system requiring a properly installed system chassis. Refer to publication 1771 IN075 for detailed information on acceptable chassis, proper installation and grounding requirements. Limit the maximum adjacent slot power dissipation to 10W maximum.

8 ac/dc (120V) Isolated Input Module Connections to the input module are made to the 40 terminal field wiring arm (cat. no. 1771-WN) shipped with the module. Attach the wiring arm to the pivot bar on the bottom of the I/O chassis. The wiring arm pivots upward and connects with the module so you can install or remove the module without disconnecting the wires. 1. Make certain all power is removed from the module before making wiring connections. 2. Swing the wiring arm up into position on the front of the module. The locking tab on the module will secure it into place. WARNING ATTENTION When you connect or disconnect the field wiring arm with field power applied, or remove the module while backplane power is on, an electrical arc can occur. This could cause an explosion in hazardous location installations. Be sure that power is removed or the area is nonhazardous before proceeding. Remove power from the 1771 I/O chassis backplane and field wiring arm before removing or installing an I/O module. Failure to remove power from the backplane or wiring arm could cause module damage, degradation of performance, or injury. Failure to remove power from the backplane could cause injury or equipment damage due to possible unexpected operation. 3. Make your connections to the field wiring arm as shown in the following figure. (Use the label on the front of the wiring arm to identify your wiring.) Note: A shorting bar may be used to connect the commons if channel-to-channel isolation is not required. IMPORTANT The field wiring arm terminal identification number is not the same as the number of the bit which controls that output.

ac/dc (120V) Isolated Input Module 9 ATTENTION Maintain isolation between phases to prevent module damage.

10 ac/dc (120V) Isolated Input Module IMPORTANT You can use an ac (120V) output module (cat. no. 1771-OA, 1771-OD or 1771-OP) to directly drive terminals on an ac/dc (120V) input module (cat. no. 1771-ID16), but you must use a 2.5K, 10W resistor between the output terminal and L2 (common) as shown in the following figure. ATTENTION Maintain isolation between phases to prevent module damage.

ac/dc (120V) Isolated Input Module 11 The module has 17 indicators (below), consisting of 16 input status indicators and an active indicator. The 16 status indicators will light when the field load has been applied to the field wiring arm of the module. The active indicator will light when the module has successfully started up and has initialized.

12 ac/dc (120V) Isolated Input Module WARNING AVERTISSEMENT

ac/dc (120V) Isolated Input Module 13

14 ac/dc (120V) Isolated Input Module

ac/dc (120V) Isolated Input Module 15