Bilaga 3A - Ljud. Layout A. 17 st Senvion M122, 3 MW Totalhöjd 150 meter

Relevanta dokument
Bilaga 3A - Ljud. Layout B. 16 st Gamesa G128, 4,5 MW Totalhöjd 150 meter

Printed/Page :41 / 1

Bilaga 23 Kompletteringar till MKB Ha lsingeskogens vindkraftpark

BULLERMODELLERING MELUMALLINNUS. Alt 1 / VE 1. Vestas V126 x 33 x hh137m

BULLERMODELLERING MELUMALLINNUS. Alt 2B / VE 2B. Vestas V126 x 28 x hh137m

Hittsjön. Vindkraftspark. Samrådsunderlag

SANDBACKA VINDKRAFTSPARK

WindPRO version jan 2009 Project:

0 2,5 5 7,5 10km Map: Översikt m avståndsringar, Print scale 1: , Map center RN East: North:

BILAGA 5 LIITE 5. Fotomontage och synlighetsanalys Valokuvasovitteet ja näkymäanalyysi

SUUNNITTELU JA TEKNIIKKA VINDIN AB OY EDSVIK VINDPARK AB POIKEL VINDKRAFTPARK. BILAGA 2. Bullermodelleringar

Calculation: Sandbacka N117 x 21 x HH141 (GF = 0,5)Noise calculation model: ISO General 8,0 m/s

VINDKRAFT GLEMMINGEBRO

WindPRO version feb SHADOW - Main Result. Calculation: inkl Halmstad SWT 2.3. Assumptions for shadow calculations. Shadow receptor-input

WTGs: 13. Project: FOR EIA. Created by: wpd Scandinavia AB Ferkens Gränd 3 SE Stockholm

WindPRO 2 version Aug 2006 Project:

WindPRO version jan 2011 Utskrift/Sida :19 / 1. DECIBEL - Huvudresultat. Beräkning Resultat. vårbo VKV.

Dokumentnamn Produktionsberäkningar, Alternativ utformning - alternativ placering Bilaga 8 till MKB för Ödmårdens Vindkraftpark Datum

Om Vindkraft. Vindkraftverk, anläggning som omvandlar

Nytt vindkraftverk i Sandvik-Stenninge. Lägesrapport oktober 2009.

WindPRO version Jul 2012

Skuggspridning från vindkraftverk. 1 Teorin bakom skuggning. Bilaga B8


BILAGA 3 LIITE 3. Sammantagen buller- och skuggningsmodellering Melu- ja varjostusvaikutusten yhteismallinnus

DECIBEL - Huvudresultat Beräkning: DD MW+1dB(A), navhöjd 149 m SVENSKA BESTÄMMELSER FÖR EXTERNT BULLER FRÅN LANDBASERADE VINDKRAFTVERK

Bilaga 1.6. Fotomontage

WindPRO version Maj 2010 Projekt:

WindPRO version Apr 2010 Projekt:

Beskrivning: Beräkning av ljud för nio vindkraftverk av modell V117, med totalhöjd 200 meter.

LJUD. fall -beräkning.

Bilaga 2.8. Ljudutbredning från vindkraftverk. 1 Teorin bakom ljud

Bullerimmission från 17 vindkraftverk i Hakefjorden, Brännö, Göteborgs stad, Västra Götalands län

l i0(3}3~j-- Vindkraftverk i Tranarp och Syllstorp i Åstorps kommun

BILAGA 2 LIITE 2. Buller- och skuggningsmodellering Melu- ja varjostusmallinnus

Komplettering tillståndsansökan Vindpark Örken Bilaga 6, Koordinatlista Layout A1/A2, justerad för värsta fallet beräkningar

Bilaga 9 PM Ljud med beräkning

VIA EPOST och POST. Bygg- och miljöförvaltningen Gamla torg Hörby L 0150/2012; dnr A HO

Tabell. Jämförelse av resultat från den svenska modellen och Nord ,9 35,7 34,3 39,9 34,6 33,1 27,9 34,7 34,4

Bilaga 1.6. Fotomontage

KittelVind. Kittelfjälls vindanläggning

Miljökonsekvensbeskrivning. Upprättad Oktober 2009 av Vind i Tiden AB efter begäran av TFE institutionen på Umeå Universitet.

1. Komplettera fågelinventeringen med en fältinventering av nattskärra och en analys av områdets potential som häckningsområde för berguv

Bilaga 5 Fotomontage 1

Miljökonsekvensbeskrivning Rata Storgrund Ver 1.0

Bilaga12. Fotomontage från Västermo

DECIBEL- Huvudresultat ~SVENSKA BESTÄMMELSER FÖR EXTERNT BULLER FRAN

Vindkraftsprojekt Hultema i Motala

WindPRO version aug 2008 Printed/Page :22 / 1. SHADOW - Huvudresultat. Öringe uppdaterad

Resultat Sida 1/7. Vindkraftpark Ögonfägnaden Siemens SWT MW 107 dba

Lönnstorp Vindbrukspark Bilagor till Miljökonsekvensbeskrivning för en vindbruksanläggning i Svalövs kommun. Bilaga Juli 2012

Resultat. Datum: Projektnummer: Projektnamn: Ljudimmissionsberäkning vindkraftpark Lönnstorp Kund: HS Kraft AB

Vindpark Hultema i Motala AB

MBK med varierande grad av verklighet. Storliden, Malå kommun.

SAMRÅDSUNDERLAG PROJEKT LJUNGSKILE-HOVEN

Ljudimmissionsberäkning av ljud från vindkraft Bilaga C01-C02 - Senvion M122 3 MW - Layout A

S U U N N IT T E L U JA T EK N IIK K A VINDIN AB OY BÖLE VINDKRAFTPARK BILAGA 3

Samrådsunderlag Allmänheten och särskilt berörda enl. MB angående ändringstillstånd för tillståndsgiven vindkraftpark Ölme

SAMRÅDSUNDERLAG. Samråd enligt miljöbalken avseende ändringstillstånd för vindkraftpark Kronoberget, Lekebergs kommun

Redogörelse från samråd med enskilda

Långmossa. Fotomontage. Version Datum Gjord av Godkänd Innehåll JRd SAd Fotomontage för Långmossa vindpark, Planutkast juni 2017

Utredning av lågfrekvent ljud från vindkraftpark Grönhult Layout A, Tranemo och Gislaveds kommuner. 2 Allmänt om lågfrekvent ljud från vindkraft

Här kommer vår komplettering av anmälan om miljöfarlig verksamhet gällande vindkraft på Filborna.

Bilaga 1 Bilagor till samrådsredogörelsen

Ljudutbredning från vindkraftverk. 1 Teorin bakom ljud. Bilaga B7

WindPRO version Jan 2009

Arvika 2019_243 Stömne Bertil Persson Betongteknik AB DECIBEL - Huvudresultat Beräkning: VKV SWE99TM VKV typ Ljuddata

S we c o In fra s tru c tur e A B Org.nr Styrelsens säte: Stockholm

Ljudutbredningsberäkning av ljud från vindkraftverk

Namn Nummer Typ Datering Antal

UTM WGS84 Zon: 33 VKV typ Skuggdata Öst Nord Z Raddata/Beskrivning Giltig Tillverkare Typ-generator Effekt, Rotordiameter Navhöjd Beräkning RPM

Samrådsversion

Höga torn för vindkraftverk

Vindkraftpark Kattegatt Offshore, Falkenberg kommun Ljudimmissionsberäkning

Bilaga 2.9. Skuggeffekter från vindkraftverk. 1 Teorin bakom skuggning

Utvärdering av lågfrekvent ljud vid den planerade vindkraftparken Gubbaberget. Författare: Andrew Birchby Datum: 21 Januari 2016 Ref:

Ljudimmissionsberäkning av ljud från vindkraft Bilaga D01-D02 - Gamesa G128 4,5 MW - Layout B

Miljöanmälan enl. MB. Hylletofta Vindkraftspark

Vattenfalls Vindkraftsplaner

Samrådsunderlag Nov 7, 2010

Vindkraftsprojekt Laxåskogen i Laxå & Askersunds kommun, Örebro län

Miljöanmälan. Frinnaryds Vindkraftverk

Staffan Engström. Vindforsk seminarium Vattenfall 15 juni 2010

Bilaga 4d Lågfrekevnt ljud REpower M114 totalhöjd 150 och 200 meter

Varför Vind? GENERAL PRESENTATION

Vill även du bli delägare i vindkraft? Nu säljer vi andelar i Legeved! Projekt Legeved

Revidering av miljöanmälan Vindkraftspark Norra Gullabo Torsås

Utredning av lågfrekvent ljud från vindkraftpark Lyckås, Jönköping kommun 1 Bakgrund. 2 Allmänt om lågfrekvent ljud från vindkraft

Bergöns Vindkraftspark Ansvariga för fotomontage Weronica Ekholm, projektledare, wpd Santiago Piva, projektutvecklare, wpd

Ljudimmissionsberäkning av ljud från vindkraftverk

Gunnarby vindkraftpark i Uddevalla kommun Kontroll av ljud från vindkraftverk

Hör nytt om ljud. Martin Almgren, ÅF-Ingemansson

SAMRÅDSUNDERLAG PROJEKT VETTEBERGET

Bilaga 4c Lågfrekvent ljud Vestas V90 totalhöjd 150 och 200 meter

Beräkning av lågfrekvent ljud från vindkraft

Transkript:

Bilaga 3A_Ljudberäkningar_Layout A_150m Grönhult Kompletteringar Bilaga 3A - Ljud Layout A 17 st Senvion M122, 3 MW Totalhöjd 150 meter

Bilaga 3A_Ljudberäkningar_Layout A_150m Project: 140330_Grönhult_MKBKompl DECIBEL - Main Result Calculation: 140408_M122_17vkv_89HH WindPRO version 2.9.269 Nov 2013 Printed/Page 2014-05-28 11:38 / 1 Licensed user: VATTENFALL AB IT Företagsenhet 1002 SE-962 80 Jokkmokk Jenny Longworth / jenny.longworth@vattenfall.com Calculated: 2014-05-28 11:37/2.9.269 SVENSKA BESTÄMMELSER FÖR EXTERNT BULLER FRÅN LANDBASERADE VINDKRAFTVERK Beräkningen är baserad på den av Statens Naturvårdsverk rekommenderad metod "Ljud frånvindkraftverk", 2010 (NV dnr 382-6897-07 Rv) WTGs Swedish RT90 2.5gonV 0:-15-RT90 (SE) WTG type Noise data East North Z Row data/description Valid Manufact. Type-generator Power, Rotor Hub Creator Name Wind LwA,ref Pure rated diameter height speed tones [m] [kw] [m] [m] [m/s] [db(a)] A1 1,358,439 6,365,530 272.8 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 2 8.0 101.7 No h A10 1,360,678 6,366,135 271.3 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A11 1,360,231 6,364,523 281.8 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 0 8.0 104.5 No h A12 1,360,807 6,365,141 270.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 0 8.0 104.5 No h A13 1,361,225 6,365,690 270.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A14 1,361,607 6,365,391 270.8 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 0 8.0 104.5 No h A15 1,361,214 6,364,706 277.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A16 1,361,858 6,364,781 278.5 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A17 1,361,557 6,364,376 281.9 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A2 1,358,455 6,365,132 293.4 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 0 8.0 104.5 No h A3 1,358,269 6,364,731 311.1 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A4 1,357,827 6,364,349 295.3 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 0 8.0 104.5 No h A5 1,357,826 6,363,944 268.4 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A6 1,358,471 6,364,158 261.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A7 1,358,818 6,364,562 287.1 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A8 1,359,241 6,364,153 278.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h A9 1,360,036 6,365,568 270.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 89.0 USER Level 1 8.0 103.0 No h h) Generic octave distribution used Calculation Results Sound Level Noise sensitive areaswedish RT90 2.5gonV 0:-15-RT90 (SE) Demands Sound Level Demands fulfilled? No. Name East North Z Imission height Noise From WTGs Noise [m] [m] [db(a)] [db(a)] 15 15 1,359,229 6,363,485 249.2 1.5 40.0 39.3 Yes 17 17 1,355,329 6,364,845 246.6 1.5 40.0 28.6 Yes 36 36 1,362,376 6,365,370 289.1 1.5 40.0 39.3 Yes 37 37 1,362,741 6,365,134 285.3 1.5 40.0 36.5 Yes 38 38 1,358,933 6,363,420 248.3 1.5 40.0 38.9 Yes A 1 1,354,438 6,365,935 231.9 1.5 40.0 25.1 Yes AA 32 1,359,427 6,365,846 262.2 1.5 40.0 39.7 Yes AB 33 1,353,753 6,365,140 228.1 1.5 40.0 23.7 Yes AC 35 1,362,402 6,364,358 271.0 1.5 40.0 38.8 Yes B 2 1,354,302 6,365,863 228.0 1.5 40.0 24.8 Yes C 3 1,355,719 6,366,777 230.0 1.5 40.0 27.4 Yes D 4 1,355,823 6,366,785 228.0 1.5 40.0 27.7 Yes E 5 1,356,247 6,366,773 220.8 1.5 40.0 28.8 Yes F 6 1,356,082 6,365,087 238.0 1.5 40.0 31.5 Yes G 7 1,356,579 6,366,515 237.5 1.5 40.0 30.4 Yes H 8 1,356,602 6,365,151 223.5 1.5 40.0 33.9 Yes I 9 1,355,989 6,364,921 223.8 1.5 40.0 31.2 Yes J 10 1,355,455 6,364,908 260.8 1.5 40.0 29.0 Yes K 11 1,356,610 6,364,688 204.8 1.5 40.0 34.7 Yes L 12 1,357,660 6,365,318 239.4 1.5 40.0 39.7 Yes M 13 1,358,185 6,366,173 238.8 1.5 40.0 37.7 Yes N 14 1,359,151 6,365,788 250.8 1.5 40.0 39.4 Yes O 18 1,358,766 6,363,487 243.7 1.5 40.0 39.7 Yes P 19 1,358,000 6,363,182 217.0 1.5 40.0 37.8 Yes Q 20 1,357,380 6,363,227 204.0 1.5 40.0 36.5 Yes R 21 1,357,225 6,363,317 206.3 1.5 40.0 36.3 Yes S 23 1,360,701 6,363,647 259.7 1.5 40.0 37.8 Yes T 24 1,361,391 6,363,807 280.0 1.5 40.0 39.9 Yes U 26 1,362,356 6,365,303 284.8 1.5 40.0 39.7 Yes To be continued on next page... WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Bilaga 3A_Ljudberäkningar_Layout A_150m Project: 140330_Grönhult_MKBKompl DECIBEL - Main Result Calculation: 140408_M122_17vkv_89HH WindPRO version 2.9.269 Nov 2013 Printed/Page 2014-05-28 11:38 / 2 Licensed user: VATTENFALL AB IT Företagsenhet 1002 SE-962 80 Jokkmokk Jenny Longworth / jenny.longworth@vattenfall.com Calculated: 2014-05-28 11:37/2.9.269...continued from previous page Noise sensitive areaswedish RT90 2.5gonV 0:-15-RT90 (SE) Demands Sound Level Demands fulfilled? No. Name East North Z Imission height Noise From WTGs Noise [m] [m] [db(a)] [db(a)] V 27 1,362,521 6,365,953 278.0 1.5 40.0 36.2 Yes W 28 1,361,906 6,366,738 260.8 1.5 40.0 35.2 Yes X 29 1,360,812 6,366,711 272.4 1.5 40.0 39.2 Yes Y 30 1,360,247 6,366,836 262.8 1.5 40.0 36.8 Yes Z 31 1,359,762 6,366,416 259.0 1.5 40.0 37.5 Yes Distances (m) WTG NSA A5 A6 A8 A15 A11 A13 A12 A4 A10 A2 A3 A17 A7 A9 A16 A1 A14 15 1475 1013 668 2329 1442 2973 2286 1646 3019 1819 1572 2491 1153 2233 2930 2191 3046 17 2654 3215 3971 5884 4910 5953 5483 2546 5500 3137 2941 6243 3499 4760 6526 3183 6299 36 4766 4087 3361 1338 2305 1194 1585 4660 1862 3927 4155 1288 3647 2347 784 3939 769 37 5054 4377 3632 1585 2582 1614 1933 4973 2291 4284 4488 1405 3962 2738 950 4318 1162 38 1224 871 795 2617 1702 3224 2543 1444 3226 1777 1469 2791 1148 2414 3224 2166 3320 A 3928 4404 5120 6882 5959 6787 6414 3739 6239 4093 4013 7283 4587 5607 7505 4018 7185 AA 2485 1938 1702 2118 1548 1804 1549 2190 1283 1206 1607 2587 1420 669 2652 1037 2226 AB 4243 4816 5573 7469 6503 7488 7050 4147 6992 4699 4531 7836 5095 6294 8108 4699 7853 AC 4592 3933 3165 1237 2176 1776 1776 4572 2474 4020 4147 845 3588 2656 689 4130 1303 B 4010 4501 5224 7004 6075 6921 6541 3834 6378 4214 4123 7401 4697 5738 7628 4147 7316 C 3529 3797 4390 5869 5042 5610 5342 3214 4998 3191 3268 6309 3807 4481 6452 2991 6046 D 3475 3728 4312 5775 4952 5509 5246 3153 4896 3106 3193 6216 3728 4383 6356 2900 5947 E 3239 3431 3977 5377 4574 5092 4841 2892 4475 2749 2872 5823 3389 3974 5951 2519 5533 F 2084 2562 3293 5143 4185 5175 4723 1894 4712 2372 2215 5518 2784 3981 5781 2397 5531 G 2856 3021 3557 4973 4158 4716 4443 2499 4115 2329 2456 5415 2969 3583 5554 2104 5150 H 1718 2115 2820 4631 3681 4652 4203 1463 4191 1852 1718 5012 2292 3458 5266 1874 5008 I 2080 2596 3340 5227 4259 5290 4821 1924 4841 2474 2287 5592 2850 4097 5868 2523 5635 J 2558 3106 3858 5759 4789 5819 5354 2435 5362 3006 2818 6121 3379 4626 6400 3046 6168 K 1425 1934 2683 4601 3623 4720 4219 1262 4315 1896 1658 4954 2210 3535 5246 2012 5043 L 1383 1414 1962 3604 2689 3582 3150 982 3125 815 845 4006 1381 2388 4229 806 3945 M 2256 2033 2277 3363 2627 3076 2816 1857 2491 1074 1443 3818 1729 1946 3925 691 3508 N 2269 1764 1636 2328 1663 2076 1777 1954 1566 956 1375 2788 1269 912 2887 757 2487 O 1044 732 818 2734 1793 3300 2626 1273 3264 1673 1338 2928 1076 2437 3350 2067 3419 P 781 1083 1575 3555 2601 4083 3421 1179 3984 2001 1571 3749 1603 3135 4173 2387 4227 Q 844 1433 2077 4107 3129 4563 3923 1207 4394 2186 1745 4329 1961 3538 4737 2533 4746 R 868 1502 2181 4221 3237 4648 4017 1194 4454 2191 1756 4457 2020 3599 4856 2522 4845 S 2888 2286 1544 1176 993 2108 1497 2957 2487 2691 2661 1124 2092 2031 1619 2941 1964 T 3565 2939 2176 916 1362 1889 1455 3603 2433 3219 3254 592 2680 2220 1080 3416 1598 U 4726 4047 3318 1287 2262 1195 1557 4626 1872 3903 4125 1223 3613 2334 720 3922 754 V 5103 4427 3739 1805 2698 1322 1895 4958 1851 4146 4422 1847 3953 2513 1345 4102 1072 W 4942 4293 3710 2145 2775 1249 1937 4724 1367 3804 4152 2386 3775 2204 1956 3670 1378 X 4069 3461 3000 2043 2263 1101 1569 3804 591 2836 3221 2450 2930 1381 2194 2650 1540 Y 3769 3211 2863 2338 2312 1506 1784 3468 822 2472 2887 2786 2684 1284 2609 2230 1983 Z 3138 2599 2321 2242 1950 1632 1648 2830 958 1831 2250 2716 2079 891 2657 1592 2109 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Bilaga 3A_Ljudkarta_Layout A_150m

Bilaga 3A_Ljudkarta_Layout A_200m

Bilaga 3A_Ljudberäkningar_Layout A_200m Grönhult Kompletteringar Bilaga 3A - Ljud Layout A 17 st Senvion M122, 3 MW Totalhöjd 200 meter

Bilaga 3A_Ljudberäkningar_Layout A_200m Project: 140330_Grönhult_MKBKompl DECIBEL - Main Result Calculation: 140408_M122_17vkv_139HH_Ljud WindPRO version 2.9.269 Nov 2013 Printed/Page 2014-05-28 11:00 / 1 Licensed user: VATTENFALL AB IT Företagsenhet 1002 SE-962 80 Jokkmokk Jenny Longworth / jenny.longworth@vattenfall.com Calculated: 2014-05-28 10:59/2.9.269 SVENSKA BESTÄMMELSER FÖR EXTERNT BULLER FRÅN LANDBASERADE VINDKRAFTVERK Beräkningen är baserad på den av Statens Naturvårdsverk rekommenderad metod "Ljud frånvindkraftverk", 2010 (NV dnr 382-6897-07 Rv) WTGs Swedish RT90 2.5gonV 0:-15-RT90 (SE) WTG type Noise data East North Z Row data/description Valid Manufact. Type-generator Power, Rotor Hub Creator Name Wind LwA,ref Pure rated diameter height speed tones [m] [kw] [m] [m] [m/s] [db(a)] A1 1,358,439 6,365,530 272.8 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 2 8.0 101.7 No h A10 1,360,678 6,366,135 271.3 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 0 8.0 104.5 No h A11 1,360,231 6,364,523 281.8 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 0 8.0 104.5 No h A12 1,360,807 6,365,141 270.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 0 8.0 104.5 No h A13 1,361,225 6,365,690 270.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h A14 1,361,607 6,365,391 270.8 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 0 8.0 104.5 No h A15 1,361,214 6,364,706 277.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h A16 1,361,858 6,364,781 278.5 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h A17 1,361,557 6,364,376 281.9 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h A2 1,358,455 6,365,132 293.4 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 0 8.0 104.5 No h A3 1,358,269 6,364,731 311.1 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h A4 1,357,827 6,364,349 295.3 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 0 8.0 104.5 No h A5 1,357,826 6,363,944 268.4 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h A6 1,358,471 6,364,158 261.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h A7 1,358,818 6,364,562 287.1 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h A8 1,359,241 6,364,153 278.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h A9 1,360,036 6,365,568 270.0 REpower 3.0M122 3000...No REpower 3.0M122-3,000 3,000 122.0 139.0 USER Level 1 8.0 103.0 No h h) Generic octave distribution used Calculation Results Sound Level Noise sensitive areaswedish RT90 2.5gonV 0:-15-RT90 (SE) Demands Sound Level Demands fulfilled? No. Name East North Z Imission height Noise From WTGs Noise [m] [m] [db(a)] [db(a)] 15 15 1,359,229 6,363,485 249.2 1.5 40.0 39.2 Yes 17 17 1,355,329 6,364,845 246.6 1.5 40.0 28.6 Yes 36 36 1,362,376 6,365,370 289.1 1.5 40.0 39.3 Yes 37 37 1,362,741 6,365,134 285.3 1.5 40.0 36.5 Yes 38 38 1,358,933 6,363,420 248.3 1.5 40.0 38.8 Yes A 1 1,354,438 6,365,935 231.9 1.5 40.0 25.1 Yes AA 32 1,359,427 6,365,846 262.2 1.5 40.0 39.8 Yes AB 33 1,353,753 6,365,140 228.1 1.5 40.0 23.8 Yes AC 35 1,362,402 6,364,358 271.0 1.5 40.0 38.7 Yes B 2 1,354,302 6,365,863 228.0 1.5 40.0 24.8 Yes C 3 1,355,719 6,366,777 230.0 1.5 40.0 27.5 Yes D 4 1,355,823 6,366,785 228.0 1.5 40.0 27.7 Yes E 5 1,356,247 6,366,773 220.8 1.5 40.0 28.9 Yes F 6 1,356,082 6,365,087 238.0 1.5 40.0 31.5 Yes G 7 1,356,579 6,366,515 237.5 1.5 40.0 30.5 Yes H 8 1,356,602 6,365,151 223.5 1.5 40.0 33.9 Yes I 9 1,355,989 6,364,921 223.8 1.5 40.0 31.2 Yes J 10 1,355,455 6,364,908 260.8 1.5 40.0 29.0 Yes K 11 1,356,610 6,364,688 204.8 1.5 40.0 34.7 Yes L 12 1,357,660 6,365,318 239.4 1.5 40.0 39.6 Yes M 13 1,358,185 6,366,173 238.8 1.5 40.0 37.7 Yes N 14 1,359,151 6,365,788 250.8 1.5 40.0 39.4 Yes O 18 1,358,766 6,363,487 243.7 1.5 40.0 39.6 Yes P 19 1,358,000 6,363,182 217.0 1.5 40.0 37.7 Yes Q 20 1,357,380 6,363,227 204.0 1.5 40.0 36.4 Yes R 21 1,357,225 6,363,317 206.3 1.5 40.0 36.2 Yes S 23 1,360,701 6,363,647 259.7 1.5 40.0 37.8 Yes T 24 1,361,391 6,363,807 280.0 1.5 40.0 39.8 Yes U 26 1,362,356 6,365,303 284.8 1.5 40.0 39.7 Yes To be continued on next page... WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Bilaga 3A_Ljudberäkningar_Layout A_200m Project: 140330_Grönhult_MKBKompl DECIBEL - Main Result Calculation: 140408_M122_17vkv_139HH_Ljud WindPRO version 2.9.269 Nov 2013 Printed/Page 2014-05-28 11:00 / 2 Licensed user: VATTENFALL AB IT Företagsenhet 1002 SE-962 80 Jokkmokk Jenny Longworth / jenny.longworth@vattenfall.com Calculated: 2014-05-28 10:59/2.9.269...continued from previous page Noise sensitive areaswedish RT90 2.5gonV 0:-15-RT90 (SE) Demands Sound Level Demands fulfilled? No. Name East North Z Imission height Noise From WTGs Noise [m] [m] [db(a)] [db(a)] V 27 1,362,521 6,365,953 278.0 1.5 40.0 36.2 Yes W 28 1,361,906 6,366,738 260.8 1.5 40.0 35.5 Yes X 29 1,360,812 6,366,711 272.4 1.5 40.0 39.9 Yes Y 30 1,360,247 6,366,836 262.8 1.5 40.0 37.3 Yes Z 31 1,359,762 6,366,416 259.0 1.5 40.0 37.8 Yes Distances (m) WTG NSA A5 A6 A8 A15 A11 A13 A12 A4 A10 A2 A3 A17 A7 A9 A16 A1 A14 15 1475 1013 668 2329 1442 2973 2286 1646 3019 1819 1572 2491 1153 2233 2930 2191 3046 17 2654 3215 3971 5884 4910 5953 5483 2546 5500 3137 2941 6243 3499 4760 6526 3183 6299 36 4766 4087 3361 1338 2305 1194 1585 4660 1862 3927 4155 1288 3647 2347 784 3939 769 37 5054 4377 3632 1585 2582 1614 1933 4973 2291 4284 4488 1405 3962 2738 950 4318 1162 38 1224 871 795 2617 1702 3224 2543 1444 3226 1777 1469 2791 1148 2414 3224 2166 3320 A 3928 4404 5120 6882 5959 6787 6414 3739 6239 4093 4013 7283 4587 5607 7505 4018 7185 AA 2485 1938 1702 2118 1548 1804 1549 2190 1283 1206 1607 2587 1420 669 2652 1037 2226 AB 4243 4816 5573 7469 6503 7488 7050 4147 6992 4699 4531 7836 5095 6294 8108 4699 7853 AC 4592 3933 3165 1237 2176 1776 1776 4572 2474 4020 4147 845 3588 2656 689 4130 1303 B 4010 4501 5224 7004 6075 6921 6541 3834 6378 4214 4123 7401 4697 5738 7628 4147 7316 C 3529 3797 4390 5869 5042 5610 5342 3214 4998 3191 3268 6309 3807 4481 6452 2991 6046 D 3475 3728 4312 5775 4952 5509 5246 3153 4896 3106 3193 6216 3728 4383 6356 2900 5947 E 3239 3431 3977 5377 4574 5092 4841 2892 4475 2749 2872 5823 3389 3974 5951 2519 5533 F 2084 2562 3293 5143 4185 5175 4723 1894 4712 2372 2215 5518 2784 3981 5781 2397 5531 G 2856 3021 3557 4973 4158 4716 4443 2499 4115 2329 2456 5415 2969 3583 5554 2104 5150 H 1718 2115 2820 4631 3681 4652 4203 1463 4191 1852 1718 5012 2292 3458 5266 1874 5008 I 2080 2596 3340 5227 4259 5290 4821 1924 4841 2474 2287 5592 2850 4097 5868 2523 5635 J 2558 3106 3858 5759 4789 5819 5354 2435 5362 3006 2818 6121 3379 4626 6400 3046 6168 K 1425 1934 2683 4601 3623 4720 4219 1262 4315 1896 1658 4954 2210 3535 5246 2012 5043 L 1383 1414 1962 3604 2689 3582 3150 982 3125 815 845 4006 1381 2388 4229 806 3945 M 2256 2033 2277 3363 2627 3076 2816 1857 2491 1074 1443 3818 1729 1946 3925 691 3508 N 2269 1764 1636 2328 1663 2076 1777 1954 1566 956 1375 2788 1269 912 2887 757 2487 O 1044 732 818 2734 1793 3300 2626 1273 3264 1673 1338 2928 1076 2437 3350 2067 3419 P 781 1083 1575 3555 2601 4083 3421 1179 3984 2001 1571 3749 1603 3135 4173 2387 4227 Q 844 1433 2077 4107 3129 4563 3923 1207 4394 2186 1745 4329 1961 3538 4737 2533 4746 R 868 1502 2181 4221 3237 4648 4017 1194 4454 2191 1756 4457 2020 3599 4856 2522 4845 S 2888 2286 1544 1176 993 2108 1497 2957 2487 2691 2661 1124 2092 2031 1619 2941 1964 T 3565 2939 2176 916 1362 1889 1455 3603 2433 3219 3254 592 2680 2220 1080 3416 1598 U 4726 4047 3318 1287 2262 1195 1557 4626 1872 3903 4125 1223 3613 2334 720 3922 754 V 5103 4427 3739 1805 2698 1322 1895 4958 1851 4146 4422 1847 3953 2513 1345 4102 1072 W 4942 4293 3710 2145 2775 1249 1937 4724 1367 3804 4152 2386 3775 2204 1956 3670 1378 X 4069 3461 3000 2043 2263 1101 1569 3804 591 2836 3221 2450 2930 1381 2194 2650 1540 Y 3769 3211 2863 2338 2312 1506 1784 3468 822 2472 2887 2786 2684 1284 2609 2230 1983 Z 3138 2599 2321 2242 1950 1632 1648 2830 958 1831 2250 2716 2079 891 2657 1592 2109 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk