Återströmningsskydd 574 och 575 typ BA

Relevanta dokument
Påfyllnadssats 580 DRIFT OCH SKÖTSEL GB SE

Återströmningsskydd 573 typ CA

ARC 32. Tvättställsblandare/Basin Mixer. inr.se

LINC 23. Tvättställsblandare/Basin Mixer. inr.se A

BATH MIXER 160 LINC 21. incl. HAND SHOWER. inr.se

Users manual Bruksanvisning Gebrauchanweisung Guide d instructions



Accepterad monteringsanvisning 2016:1. Metris (RSK: ) Metris S (RSK: ) Metris (RSK: )

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) 1 (12)

Accepterad monteringsanvisning 2016:1

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S 100 CoolStart (RSK: )

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENS LÄS IGENOM INSTRUKTIONSMANUALEN

SAFETY PRECAUTIONS SPECIFICATIONS

STRICT Art.nr ,

Accepterad monteringsanvisning 2016:1. Ecos M CoolStart (RSK: ) Ecos L CoolStart (RSK: ) 1 (12)

Fiat » Fiat Panda / 4x4 2003» Fiat Panda 4x4 Climbing / 4x4 Cross 20033»

POSH. Art.nr

Windlass Control Panel v1.0.1

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S (RSK: ) 1 (12)

SUZUKI GRAND VITARA 3P CITY 2011»

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK

Accepterad monteringsanvisning 2016:1. Talis E ( ) ( ) Talis E 110 CoolStart ( )

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) Focus 100 CoolStart (RSK: ) (RSK: )

Företagsnamn: Grundfos Skapad av: Magnus Johansson Tel: +46(0) Datum:

Komponenter Removed Serviceable

Bathtub Filler CN EN. TBP02201 Type / TBP02202 Type. Installation Manual. Continued on the back cover

Viktig information för transmittrar med option /A1 Gold-Plated Diaphragm

CANALKLER 250S. Gänga i tum Thread in inch

Återströmningsmodul AVi 1680

Monteringsanvisning Nödutrymningsbeslag ASSA 179E

SAFETY PRECAUTIONS SPECIFICATIONS

CASUAL. Art.nr

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENSLÄS IGENOM INSTRUKTIONSMANUALEN NOGGRANT

P650 - Takscreen. Installationsguide EN

BRIC MODELL A

FORTA M315. Installation. 218 mm.

A » VW

Instruction Manual. Svenska, English. Power Bank. Model: PRBN

Boiler with heatpump / Värmepumpsberedare

LÄNKHJUL S3. Monteringsanvisning för: Länkhjul S3

LINC 23 TVÄTTSTÄLLSBLANDARE

THISAB Monteringsanvisningar till Brand- och spolposter

Fig. 2: Inkoppling av lindningarna / Winding wiring diagram

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

DAMPER EQAZ-12, EQAZ-13, STAZ-30, STBZ-30

Installation Instructions

Bruksanvisning Directions for use

VASSVIK FIXED STAND SE / ENG

Joki Joki Air. JCD70-xx JAD90-xx. lasiesta.com. Manual. Betriebsanleitung. Manuel. Manual. Manuale. Gebruiksaanwijzing.

GOLD SD Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1. Fläkt 2/ Fan 2. Med filter/ With filter Filter

Hose reel CRO Slangrulle CRO

Mitsubishi Montero io 10/1999» Pajero Pinin 3-5 platser

VARIOBARRIER S/M MIMSAFE BY CHOICE

Support Manual HoistLocatel Electronic Locks

Congratulations on purchasing an ATS towbar. Gratulationer till er nyinköpta ATS dragkrok

Tryck- och svetsseminarie 2014 Föredrag: Golden welds vad är problemet? Föredragshållare: Mikael Rehn, Inspecta Sweden AB

Nathi Skötbord Changing unit Table à langer murale Wickeltisch Verschoontafel Puslebord Cambiador de pared Přebalovací pult Fasciatoio

Technical description with installation and maintenance instructions

Oförstörande provning (NDT) i Del M Subpart F/Del 145-organisationer

Your No. 1 Workout. MANUAL pro

IRAB Mottagare sida 2-5 Tele Radio AB Mottagare sida 6

SkillGuide. Bruksanvisning. Svenska


Beijer Electronics AB 2000, MA00336A,

PRESS FÄLLKONSTRUKTION FOLDING INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) Talis S² Variarc (RSK: ) Metris (RSK: )

PRESS FÄLLKONSTRUKTION FOLDING INSTRUCTIONS

Storlek/ Size. Modell/ Model. Effekt/ Effect. Vattenmängd/ Water amount T30 63W T30 87W T30 67W T30 76W T30 108W T30 121W

SVENSK STANDARD SS-ISO 8779:2010/Amd 1:2014

Manual för installation drift och underhåll Modell UVEX (gäller även plus)

Taxning och motorkörning av flygplan/helikopter

Metodprov för kontroll av svetsmutterförband Kontrollbestämmelse Method test for inspection of joints of weld nut Inspection specification

MCP-16RC, Air Purification

ASSEMBLY INSTRUCTIONS SCALE - SYSTEM

Z-LYFTEN PRODUKTION AB MONTERINGSANVISNING INSTALLATION INSTRUCTIONS

FLUID SOLUTIONS 700ZDT & 700NDT. NAMUR Solenoid Valve 3/2 5/2 INSTALLATION, OPERATION & MAINTENANCE MANUAL. JWB USA, Inc. TUNING FLUID SOLUTIONS

334 mm x 248 mm Rostfritt stål. Kg lb g. -5 till +40 C. LCD med belysning 25 mm (H) x 12 mm (B), 6 siffror.

EASA FTL (Flygarbetstid)

Utfärdad av Compiled by Tjst Dept. Telefon Telephone Datum Date Utg nr Edition No. Dokumentnummer Document No.

This manual should be saved! EcoFlush Manual. Wostman 2018:2

LINC 22 SHOWER MIXER 150 SHOWER MIXER 160. inr.se

STANDARD. UTM Ingegerd Annergren UTMS Lina Orbéus. UTMD Anders Johansson UTMS Jan Sandberg

INSTALLATION. (SE) Duschkabin och ångbastu (UK) Shower cabins and steam cabins. Model

Användarhandbok. MHL to HDMI Adapter IM750

Digital Personvåg MANUAL H

SVENSK STANDARD SS-ISO 8734

(SV) Installationsmanual för duschkabiner och ångbastukabiner (EN) Installation manual for shower cabins and steam cabins

Monteringsanvisning Podie T 4100 K

Isolda Purchase - EDI

Shower cabins / Steam cabins

AquaTeq Sweden AB Radarvägen 12 SE KALMAR. PHONE: +46 (0) INTERNET:

81152 TRANSFER CASE SHIFT HANDLE

Molift Raiser 75135G Etac Box 203, Anderstorp Sweden Tel Fax

Får endast utföras av behörig personal. May only be carried out by authorized electrician

BBT057/ BBC057 BBCD057/ BBT057-NL HOLDEN COLORADO 9/2016+ HOLDEN TRAILBLAZER WD & 4WD Models

55R Kia Carens 2013»

Transkript:

06 sida av Backflow Preventer - BA type - Reduced Pressure Zone principle Återströmningsskydd typ BA med reducerad tryckzon GB SE Application Användning The backflow preventer can be used in all systems where there is danger of the drinking water supply system being contaminated. It prevents an accidental reduction in the pressure in the distribution system from causing the contaminated water in user installations to return back. To WRAS EN 7 and AS standards (AS/NZS 8.). Återströmningsskydd kan användas i alla system där det finns risk för att dricksvattnet kan bli förorenat. Det förhindrar förorenat vatten från att strömma tillbaka vid tryckfall i distributionssystemet. Enligt standard EN 7. ANTIPOLLUTION SC0-0.7/ 7 7 7 7 700 / (DN ) 700 / (DN 0) 7600 (DN ) 7700 / (DN ) 7800 / (DN 0) 700 (DN 0) 700 (DN 0) 7006 (DN 6) 7008 (DN 80) 700 (DN 00)

06 sida av Technical specification Materials: - body and cover: - /" /"dezincification resistant alloy EN 6 CW60N - / DN 00; bronze RG Pb DIN 00-6 - check valve stem and springs stainless steel - diaphragm and seals: NBR Medium: drinking water PN 0 Maximum working temperature: 6 C Pressure tapping points: upstream, intermediate, downstream Union connections ISO 7/: /" - /" - " - /" - /" - " M with union Flange connection: DN 0, DN 6, DN 80 e DN 00 ISO PN0 Complies with standars: NF, DVGW, KIWA, WRAS, SVGW, AS, BELGAQUA, ACS, SITAC, DTI Certification: EN 7 Acoustic Group : I (/ / ) Teknisk specifikation Material: Hus: Dimension ½ - ¼ Avzinkningshärdig mässing EN 6 CW60N Dimension ½ -DN00 Brons RG Pb DIN 00-6 Backventil: Rostfritt stål Fjädrar: Rostfritt stål Membran: NBR Packningar: NBR Medium: Dricksvatten Tryckklass: PN 0 Max arbetstemperatur: 6 C Kontrollventiler: Uppströms, mellanliggande kammare, nedströms Unionskopplingar ISO 7/: /" - /" - " - /" - /" - " M utvändig gänga och löpmutter Flänsanslutning: DN 0, DN 6, DN 80, DN 00, ISO PN 0 Godkännande: NF, DVGW, KIWA, WRAS, SVGW, AS, BELGAQUA, ACS, SITAC, DTI Certifierad enligt: EN 7 Akustisk grupp: I (/ / )

06 sida av Flow curves Tryckfallsdiagram p (bar),8,6,, 0, 0,8 0,7 0,6 0, 0, 0, 0, 0, 0, 0,6 0,7 0,8 0,,,,6,8, /,, / 6 7 8 0 / 6 8 0 / 0 0 0 G (m /h) p (m c.a.) p (m w.g.) 0 8 6 0 8 7 6,, p (bar),8,6,, 0, 0,8 0,7 0,6 0, 0, 0, 0, 0, 6 7 8 0 6 8 0 DN 0 0 0 0 DN 6 DN 80 60 70 80 0 DN 00 00 p (m c.a.) p (m w.g.) 0 0 0 60 80 00 G (m /h) 8 6 0 8 7 6,,

06 sida av Operation Funktion A B 6 The backflow preventer consists of two check valves () and (), a chamber known as "reduced pressure area" (B) and of a discharge valve connected to the latter (). The water entering the backflow preventer opens the upstream check mechanism and at the same time through the pipe () acts on the diaphragm () which closes the discharge valve by means of the rod and then opens the downstream check mechanism. The pressure in the intermediate chamber under normal operating conditions is always less than the upstream pressure by at least 0 mbar (, m.w.g.) as a result of a pre-calculated pressure loss on the first check mechanism. This difference in pressure p between the upstream (A) and intermediate (B) areas can be specified on a safety basis so that in the event of damage occuring or a vacuum the discharge valve is opened when the upstream pressure is still greater than the pressure in the intermediate area by at least 0 mbar. Moreover in the event of demage to the diaphragm the safety gasket thrust by the contrast spring prevents the return of the water upstream through the pipe. Consequently with efficient equipment there is no possibility of a return of the water from the intermediate area to the upstream area even if the check mechanisms have small sealing defects which would moreover be indicated by the outlet of the water from the discharge so that the p balance between the two areas would be endangered. N.B. To ensure correct operation the air must be bled in the upper part of the diaphragm by means of the relief screw (6). Återströmningsskyddet består av två backventiler () och (), en mellanliggande kammare även kallad den tryckreducerade zonen (B) och en dräneringsventil () ansluten till kammaren. Inkommande vatten öppnar uppströms backventil och verkar samtidigt, genom kanal () på membranet så att dräneringsventilen stängs. Nedströms backventil öppnar. Trycket i den mellanliggande kammaren understiger alltid under normal drift trycket uppströms med minst 0 mbar (, mvp) på grund av tryckfallet över den första backventilen. Denna tryckskillnad säkerställer att dräneringsventilen öppnar vid tryckfall uppströms eller fel i systemet nedströms redan när tryckskillnaden minskat till 0 mbar. Om membranet skadas öppnar säkerhetsfjädern utloppsventilen och förhindrar vatten att strömma bakåt. Vatten kan således aldrig strömma från den mellanliggande zonen till zonen uppströms. Om backventilerna har skador på tätningsytorna märks detta genom att vatten droppar från dräneringsventilen. Anm: För korrekt funktion måste återströmningsskyddet luftas med hjälp av luftningsskruven (6). Δp

DRIFT OCH SKÖTSEL 06 sida av Installation Installation The installation of backflow preventer should only be carried out by qualified personnel in accordance with current legislation. The backflow preventer is installed after an upstream isolation valve and a strainer which can be inspected whith a discharge with another isolation valve being fitted downstream. The unit is installed in an accessible area wich is of such a size as to avoid possible immersions due to accidental flooding (See diagram). The equipment is installed horizontally. The tundish, complying with the EN 77 standard, must be connected to the discharge sewerage. Before installing the backflow preventer and the strainer the pipe should be cleaned with a high-capacity water jet. In order to protect the public supply system the backflow preventer is installed after the water meter and to protect supplies for sanitary purposes in the internal system it is fitted at the limit of the areas in which contamination can take place as for example centralized heating systems, garden watering systems etc. Återströmningsskyddet skall installeras av rörläggare med branschlegitimation och enligt instruktionerna i i denna manual samt enligt gällande lagar. Återströmningsskyddet skall installeras horisontellt, efter en avstängningsventil och ett inspekterbart filter; ytterligare en avstängningsventil skall installeras nedströms. Enheten skall installeras så den inte oavsiktligt kan översköljas av vatten. Dräneringsledning skall dras till avlopp med tillräcklig kapacitet. Återströmningsskyddet skall installeras horisontellt och med flödesriktningen enligt pilen på huset. Innan återströmningsskyddet installeras skall rörledningarna renspolas. Bristande rengöring kan medföra att enheten ej fungerar korrekt. För att skydda det kommunala ledningsnätet skall återströmningsskyddet placeras efter vattenmätaren. För att skydda det interna ledningsnätet placeras skyddet så nära riskerna som möjligt, som exempel: påfyllning till värmesystem, bevattningsanläggning. Installation diagram Installationsschema H L L L H Tunnel sewerage Avlopp 0,0 m min Pipe Rör B = 0,0, m Discharge to sewerage Dränering till avlopp GROUND, FLOOR, GANGWAY GOLV Shut-off valve Strainer Backflow preventer Shut-off valve Avstängningsventil Smutsfilter Återströmningsskydd Avstängningsventil

06 sida 6 av Maintenance Underhåll As the backflow preventer is an item of equipment used to ensure the safety of domestic water supplies it must be inspected periodically. The first sign that the equipment is not functioning properly which is generally associated with the presence of foreign bodies (sand or other impurities) will be indicated by a permanent leakage through the discharge. This loss is just an initial warning sign and does not completely jeopardize the safety of the check mechanism but means that the unit should be dismantled and the equipment and the upstream filter should be cleaned. A rapid inspection method (takes less than minutes) is described in the table below. N.B. In the event of a loss at the discharge it is recommended to cause a strong circulation flow for a few minutes by opening one or more taps. This will often be sufficient to expel any foreign bodies and to get equipment to operate normally again. Återströmningsskyddet är ett skydd för hälsan och kräver regelbunden inspektion. Första tecknet på bristande funktion är konstant läckage från dräneringsventilen. Detta orsakas oftast av smuts på backventilerna. Detta läckage äventyrar inte funktionen utan är endast en signal om att installationen behöver kontrolleras samt att filtret behöver rengöras. En snabb kontrollrutin (tar mindre än minuter) beskrivs nedan. N.B. I händelse av läckage från dräneringsventilen rekommenderas att skapa ett stort flöde genom att öppna en eller flera tappställen några minuter. Ofta är detta tillräckligt för att spola bort smuts från backventilerna och återställa funktionen.

06 sida 7 av RAPID INSPECTION PROCEDURE FUNKTIONSKONTROLL OPERATION OPERATION DEFECT DETECTED IAKTTAGELSE CAUSE ORSAK ACTION TO BE TAKEN ATGÄRD Close downstream isolation valve - Permanent leakage - No leakage Upstream valve or discharge valve not leaktight Dismantle and check Stäng nedströms avstängningsventil - Permanent läckage - Inget läckage Uppströms backventil eller dräneringsventil är ej täta Demontera och kontrollera Close upstream shut-off valve and open upstream pressure control cock - Discharge does not open. Leakage is minimal and lasts more than minute - Discharge opens abruptly and equipment is emptied in less than one minute Discharge blocked Dismantle and check Stäng uppströms avstängningsventil och öppna uppströms kontrollventil - Dräneringsventilen öppnar ej. Läckaget är minimalt och varar mer än en minut - Dräneringsventilen öppnar kammaren töms på mindre än en minut Dräneringsventilen kärvar Demontera och kontrollera Open downstream shut-off valve - Continuous discharge - No discharge Downstream valve not leaktight Dismantle and check Put the equipment back into operation Öppna nedströms avstängningsventil - Läckage Nedströms backventil är ej tät Demontera och kontrollera. Återta återströmningsskyddet i drift

06 sida 8 av / - / Checks on and where necessary replacements for the internal parts of the backflow preventer Kontroll och utbyte av delar i återströmningsskyddet The illustrations below show the operations required for checking the functional parts inside /, / size backflow preventer. Illustrationerna nedan visar hur delarna i återströmningsskydd /, / och kontrolleras.. Release the pressure using the cocks fitted to the backflow preventer. Remove the cover bolts. Öppna kontrollventilerna. Skruva bort bultarna som håller locket.. Pull out the central assembly and contrast spring. Ta ut membran, dräneringsventil och fjäder.. Pull out the seat of the discharge valve by pushing it from the outside whilst handling it with care so as not to damage it. Caution : If it should not be removed protect it from possible damage which could result from changing the check valves. Ta ut ventilsätet till dräneringsventilen genom att trycka på det från utsidan. Iakttag försiktighet så det ej skadas. Varning : Om ventilsätet inte tas bort ska det skyddas för att undvika skador vid byte av backventiler

06 sida av / - /. Remove the split rings holding the check valves in place with a pair of long-jaw pliers. Ta bort Seegersäkringarna som håller backventilerna. Använd en lämplig tång.. Remove the upstream and downstream check valves using a common pipe wrench or suitable size pliers. Ta bort uppströms och nedströms backventiler med hjälp av en tång. 6. After carrying out the inspection and after replacing any necessary components when refitting the check valves make sure that the split rings are perfectly located in the seat. Efter kontroll och efter utbyte återmonteras backventilerna. Se till att Seegersäkringarna kommer rätt i spåren.

06 sida 0 av - / Checks on and where necessary replacements for the internal parts of the backflow preventer Kontroll och utbyte av delar i återströmningsskyddet The illustrations below show the operations required for checking the functional parts inside " and /" size backflow preventers. Illustrationerna nedan visar hur delarna i återströmningsskydd - /" kontrolleras.. Release the pressure using the cocks fitted to the backflow preventer. Remove the cover. Öppna kontrollventilerna. Ta bort locket. Pull out the central assembly and contrast spring. Ta ut membran, dräneringsventil och fjäder.. Pull out the seat of the discharge valve by pushing it from the outside whilst handling it with care so as not to damage it. Caution : If it should not be removed protect it from possible damage which could result from changing the check valves. Ta ut ventilsätet till dräneringsventilen genom att trycka på det från utsidan. Iakttag försiktighet så det ej skadas. Varning : Om ventilsätet inte tas bort ska det skyddas för att undvika skador vid byte av backventiler

06 sida av - /. Remove the split rings holding the check valves in place with a pair of long-jaw pliers. Ta bort Seegersäkringarna som håller backventilerna. Använd en lämplig tång.. Remove the upstream and downstream check valves using a common pipe wrench or suitable size pliers. Ta bort uppströms och nedströms backventiler med hjälp av en tång. 6. After carrying out the inspection and after replacing any necessary components when refitting the check valves make sure that the split rings are perfectly located in the seat. Efter kontroll och efter utbyte återmonteras backventilerna. Se till att Seegersäkringarna kommer rätt i spåren.

06 sida av / - Checks on and where necessary replacements for the internal parts of the backflow preventer Kontroll och utbyte av delar i återströmningsskyddet The illustrations below show the operations required for checking the functional parts inside / and size backflow preventer for. Illustrationerna nedan visar hur delarna i återströmningsskydd / - kontrolleras.. Release the pressure using the cocks fitted to the backflow preventer. Remove the cover bolts. Öppna kontrollventilerna. Ta bort locket.. Pull out the central assembly and contrast spring. Ta ut membran, dräneringsventil och fjäder.. Pull out the seat of the discharge valve by pushing it from the outside whilst handling it with care so as not to damage it. Caution : If it should not be removed protect it from possible damage which could result from changing the check valves. Ta ut ventilsätet till dräneringsventilen genom att trycka på det från utsidan. Iakttag försiktighet så det ej skadas. Varning : Om ventilsätet inte tas bort ska det skyddas för att undvika skador vid byte av backventiler

06 sida av / -. Remove the split rings holding the check valves in place with a pair of long-jaw pliers. Ta bort Seegersäkringarna som håller backventilerna. Använd en lämplig tång.. Remove the upstream and downstream check valves using a common pipe wrench or suitable size pliers. Ta bort uppströms och nedströms backventiler med hjälp av en tång. 6. After carrying out the inspection and after replacing any necessary components when refitting the check valves make sure that the split rings are perfectly located in the seat. Efter kontroll och efter utbyte återmonteras backventilerna. Se till att Seegersäkringarna kommer rätt i spåren.

06 sida av DN 0-6-80-00 Checks on and where necessary replacements for the internal parts of the backflow preventer Kontroll och utbyte av delar i återströmningsskyddet The illustrations below show the operations required for checking the functional parts inside DN 0, DN 6, DN 80 and DN 00 size backflow preventer for. Illustrationerna nedan visar hur delarna i återströmningsskydd DN 0, DN 6, DN 80 och DN 00 kontrolleras.. Release the pressure using the cocks fitted to the backflow preventer. Remove the cover bolts. Öppna kontrollventilerna. Ta bort locket. Pull out the central assembly and contrast spring. Ta ut membran, dräneringsventil och fjäder.. Pull out the seat of the discharge valve by pushing it from the outside whilst handling it with care so as not to damage it. Caution : If it should not be removed protect it from possible damage which could result from changing the check valves. Ta ut ventilsätet till dräneringsventilen genom att trycka på det från utsidan. Iakttag försiktighet så det ej skadas. Varning : Om ventilsätet inte tas bort ska det skyddas för att undvika skador vid byte av backventiler.

06 sida av DN 0-6-80-00. Remove the split rings holding the check valves in place with a pair of long-jaw pliers. Ta bort Seegersäkringarna som håller backventilerna. Använd en lämplig tång.. Remove the upstream and downstream check valves using a common pipe wrench or suitable size pliers. Ta bort uppströms och nedströms backventiler med hjälp av en tång. 6. After carrying out the inspection and after replacing any necessary components when refitting the check valves make sure that the split rings are perfectly located in the seat. Efter kontroll och efter utbyte återmonteras backventilerna. Se till att Seegersäkringarna kommer rätt i spåren.

06 sida 6 av 700 / (DN) - 700 / (DN0) 7 8 0 7600 (DN ) - 7700 / (DN) 7 8 0

06 sida 7 av 7800 / (DN0) - 700 (DN0) 7 8 0 6 6 7 8 0 Discharge assembly Upstream check valve Downstream check valve Discharge valve seat Tundish Deflector Test cock Inspection cover Split ring Body Gasket Tailpiece Nut Dräneringsventil Uppströms backventil Nedströms backventil Ventilsäte för dräneringsventil Fäste för dräneringsledning Stänkskydd Kontrollventil Lock Seegersäkring Hus Packning Nippel Mutter

06 sida 8 av 700 (DN0) - 7006 (DN6) - 7008 (DN80) - 700 (DN00) 7 8 0 6 6 7 8 0 Discharge assembly Upstream check valve Downstream check valve Discharge valve seat Tundish Deflector Test cock Inspection cover Split ring Body Dräneringsventil Uppströms backventil Nedströms backventil Ventilsäte för dräneringsventil Fäste för dräneringsledning Stänkskydd Kontrollventil Lock Seegersäkring Hus

06 sida av Safety Säkerhet The backflow preventer must be installed by a licensed plumber in accordance with national regulations and/or relevant local requirements. If the backflow preventer is not installed, commissioned and maintained properly, according to the instructions contained in this manual, it may not operate correctly and may endanger the user. Make sure that all the connecting pipework is water tight. When making the water connections, make sure that the backflow preventer connecting pipework is not mechanically over-stressed. Over time this could cause breakages, with consequent water losses which, in turn, could cause harm to property and/or people. Water temperatures higher than 0 C can cause serious burns. During the installation, commissioning and maintenance of the backflow preventer, take the necessary precautions to ensure that such temperatures do not endanger people. In the case of highly aggressive water, arrangements must be made to treat the water before it enters the backflow preventer, in accordance with current legislation. Otherwise the mixer may be damaged and will not operate correctly. Leave this manual for the user Återströmningsskyddet skall installeras av rörläggare med branschlegitimation och enligt instruktionerna i denna manual samt enligt gällande lagar. Om återströmningsskyddet inte installeras, tas i drift och underhålls enligt instruktionerna i denna manual kan användarna utsättas för fara. Kontrollera att alla anslutningar är täta. Utsätt inte kopplingarna för stor mekanisk påfrestning. För stora påfrestningar kan medföra att kopplingarna brister och orsakar läckage som kan skada egendom och/eller personer. Vattentemperatur över 0 C kan orsaka brännskador. Vidtag säkerhetsåtgärder vid installation, idrifttagande och service så att inga personskader orsakas av varmt vatten. Om vattnet är extremt hårt skall avhärdningsutrustning installeras uppströms. I annat fall kan återströmningsskyddet skadas så det ej fungerar korrekt. All annan användning än avsedd är förbjuden. Lämna denna instruktion till användaren