OPERATING INSTRUCTIONS ESC-100. Professional CATV QPSK to QAM transmodulator. English. Svenska. design for TV



Relevanta dokument
OPERATING INSTRUCTIONS. ESC-100 and ESC-200. Professional CATV QPSK/8PSK to QAM transmodulators. English. Svenska. design for TV

OPERATING INSTRUCTIONS ETC-100. Professional CATV COFDM to QAM Transmodulator. English. Svenska. design for TV

OPERATING INSTRUCTIONS ETT-100. Professional CATV Multisystem Channel Processor. English. Svenska. design for TV

OPERATING INSTRUCTIONS ECA-100. Professional Digital QAM Receiver. English. Svenska. design for TV

OPERATING INSTRUCTIONS EFM-100. Professional FM Radio Processor. English. Svenska. design for TV

OPERATING INSTRUCTIONS EMU-100. E-series Remote Management Unit. English. Svenska. design for TV

OPERATING INSTRUCTIONS. ESA-110 and ESA-111. Professional Digital Satellite Receiver. English. Svenska. design for TV

"#$!! %&&' &&& English. Svenska

OPERATING INSTRUCTIONS. EVA-200, EVA-201 and EVA-210. Professional CATV VSB modulators EVA-210 with NICAM stereo. English. Svenska.

InstalationGuide. English. MODEL:150NHighGain/30NMiniUSBAdapter

OPERATING INSTRUCTIONS. ETA-100 and EFTA1-T2. Professional Digital Terrestrial Receivers. English. Svenska. design for TV

Beijer Electronics AB 2000, MA00336A,

DS-2900S2/PAL. DVB-S/S2 till PAL med grannkanalmodulator. Bruksanvisning

Quick Start Guide Snabbguide

Svenska sidan 1-4 English page 5-7 CCIR sid/page 8

Support Manual HoistLocatel Electronic Locks

Remote control Fjärrströmbrytare / Fjernstrømbryter

Installation Instructions

1. Unpack content of zip-file to temporary folder and double click Setup

CanCom Bluetooth BLUETOOTH V5.6. Specifikation Specification LED. transceiver

2.1 Installation of driver using Internet Installation of driver from disk... 3

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

Personsökare Intelpage IP 5 och LarmNet Installationsanvisning

Windlass Control Panel v1.0.1

Kanalprocessor Ref: 5179

Webbregistrering pa kurs och termin

2.45GHz CF Card Reader User Manual. Version /09/15


Product configurations Produire configuration Produkt konfigurationen Producto configuraciones Produkt konfigurationerna

Resurser. Visa sidan Hjälpguide. Menykarta. Phaser 4400 laserskrivare

Quick Start Guide. To switch the TV on. cable to connect the two units together. To select the TV broadcasts. To HDMI connection on.

BRUKSANVISNING. Oscilla 910

Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

Programmera Avant 5 med PC mjukvara

Installationsguide. EG200 Multi WAN Residential Gateway. v

electiaprotect GSM SEQURITY SYSTEM Vesta EZ Home Application SMART SECURITY SYSTEMS! SVENSKA ios Android

Användarhandbok. MHL to HDMI Adapter IM750

42.MST 1/D (E )


SkillGuide. Bruksanvisning. Svenska

Schenker Privpak AB Telefon VAT Nr. SE Schenker ABs ansvarsbestämmelser, identiska med Box 905 Faxnr Säte: Borås

Installationsguide. DG200 Multi WAN Residential Gateway V

Lösenordsportalen Hosted by UNIT4 For instructions in English, see further down in this document

Instruction Manual. Svenska, English. Power Bank. Model: PRBN

Boiler with heatpump / Värmepumpsberedare

Problem som kan uppkomma vid registrering av ansökan

Schenker Privpak AB Telefon VAT Nr. SE Schenker ABs ansvarsbestämmelser, identiska med Box 905 Faxnr Säte: Borås


GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

IM10. Installation Note ENGLISH. Before you start the installation, make sure that the following material is available:

, fukt- och temperaturdetektor Modbus RTU, trafikljus

PLL KRETS. 2.4 GHz MIC INBYGGD LCD TFT VID-TRANS300 VID-TRANS310 VID-TRANS320 SVENSKA PAN & TILT MÖRKER SEENDE IR LED MANUAL KANALER ENHET

Kanalprocessor T-05 / DIGITAL 5870

Webbreg öppen: 26/ /

Aktiv DVB-T Inomhus Antenn SRT ANT 12

Every visitor coming to the this website can subscribe for the newsletter by entering respective address and desired city.

Får endast utföras av behörig personal. May only be carried out by authorized electrician

FORTA M315. Installation. 218 mm.

GOLD SD Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1. Fläkt 2/ Fan 2. Med filter/ With filter Filter

Om oss DET PERFEKTA KOMPLEMENTET THE PERFECT COMPLETION 04 EN BINZ ÄR PRECIS SÅ BRA SOM DU FÖRVÄNTAR DIG A BINZ IS JUST AS GOOD AS YOU THINK 05

Quick Start. English Svenska PRIMACY. Printing settings and winsign

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK

Huvudcentraler att växa med

Alias 1.0 Rollbaserad inloggning

Användarhandbok. USB Charging Dock DK52

Spotlight Set Spotlightset / Spotlightsett

INSTALLATION INSTRUCTIONS

T-0X modulator. Ref: Twin med A2-stereo. Modulator 5806 programmeras med PCT-4.0 eller nyare

PRESS FÄLLKONSTRUKTION FOLDING INSTRUCTIONS

Svensk version. Inledning. Installation av maskinvara. Installation av Windows XP. LW057V2 Sweex trådlösa LAN PCI-kort 54 Mbps

nwind and nwind-race transducer Twin Fin Installation Manual English Installationsmanual Svensk

Svensk Bruksanvisning

D-285 r0. Installationsanvisning för ServiceTool

Quick Start. English Svenska. Moca

Installation av F13 Bråvalla

WhatsApp finns för dessa plattformar:

IRAB Mottagare sida 2-5 Tele Radio AB Mottagare sida 6

DIM-20. Skapa en egen DVB-T kanal. COFDM-modulator

How to format the different elements of a page in the CMS :

Isolda Purchase - EDI

Magic Grippers System för att enkelt bygga robotgrippers / grippers. -- Kort presentation -- Beställ komplett katalog

Your No. 1 Workout. MANUAL pro

Decoration Light Dekorationsbelysning/Dekorasjonsbelysning

Styrteknik: Binära tal, talsystem och koder D3:1

Manual. Video Tour:

SE: Monteringssanvisning för IR-9MP Comfort GB: Installation manual for IR-9MP Comfort

Swema 05. Bruksanvisning vers 1.01 MB

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter

Bruksanvisning MS Babyvåg OBS! Läs igenom bruksanvisningen innan produkten tas i bruk.

Diskant Yta eller Vikelfäste montering Mount

SVENSK STANDARD SS :2010

HANTERING AV UPS CX

DPR-34+ Svensk Bruksanvisning. Läs igenom denna bruksanvisning innan användning av produkten och spara bruksanvisningen för framtida användning.

ARC 32. Tvättställsblandare/Basin Mixer. inr.se

Trådlös TV-länk SLV3100. Bruksanvisning

Digital Active Indoor DVB-T Antenna SRT ANT 12

Viktig information för transmittrar med option /A1 Gold-Plated Diaphragm

balans Serie 7 - The best working position is to be balanced - in the centre of your own gravity! balans 7,45

Transkript:

OPERATING INSTRUCTIONS ESC-100 Professional CATV QPSK to QAM transmodulator Svenska design for TV 1

Contents 1. Introduction 2. Unpacking the unit 3. Connections and indications 4. Settings with PALM PDA 5. Settings with PC 6. Installation 7. Technical specification 8. Declaration of Conformity 2

1. Introduction Thank you for choosing an A2B Electronics product. We have made every effort to make you as a customer satisfied with the performance and features of this product for years to come. The ESC-100 is a high quality professional CATV QPSK to QAM transmodulator intended for use in any Cable TV or SMATV head end. All functions are integrated in an extremely compact unit that easily can be mounted in different ways. ESC-100 incorporates a broadcast quality QAM modulator for direct connection to a CATV/SMATV network. This manual describes the installation and settings of the unit. For further assistance, contact your local dealer or our technical support:. A2B Electronics AB Phone: +46 (0)141 229115 E-mail: support@a2b.se Also visit our web site www.a2b.se for further support. 3

2. Unpacking the unit ESC-100 is delivered with all necessary software to enable all the installations. The files are on the included CD and a PC or PALM PDA can be used as a control unit. Following parts are included in the package: Amount Description 1 QPSK to QAM transmodulator ESC-100 1 CD-ROM with operating instructions and control software 1 This operating instruction in printed version 4 Front panel screws Every unit is quality inspected by us before delivery and should any items be missing when unpacking please contact our support service (see page 3 for address). 4

3. Connections and indications Power on indicator QPSK error indicator QAM error indicator RS-232 port for control and settings RF out DC in LNB in Power on indicator QPSK error indicator QAM error indicator RS-232 port for control and settings LNB in RF out DC in Green light indicates that power is on. Red light indicates that the receiver is not locked. Red light indicates that modulator is not working. Serial port for connection to a PC or Palm (control software available on attached CD). Connect your outdoor unit (LNB) to this input. Connection to Cable TV or SMATV network. Connect a DC voltage to this input (6-9 V 2A). 5

4. Settings with PALM PDA This section describes how to make a quick installation following the step by step instructions below. See to that the control software files delivered on the CD- ROM are loaded into the PALM. For more information on how this is done, please consult your PALM user manual. 1. Connect the ESC-100 to a DC power supply (the ESP-100 or EPP-100). Then connect your PALM PDA to the ESC-100 with a PALM Hotsync cable to the RS-232 serial port on the front of ESC-100. 2. Tap the ESC icon in the A2B Control menu of the PALM. 3. A Welcome menu should appear if your PALM is in contact with the ESC-100. Click [Next]. 6

4. This menu contains settings of the tuner parameters and choice of LNB type. Enter appropriate values for transponder Frequency, Symbol rate and Polarization and click [Next]. Now you can see that the receiver is locking and the Eb/No value. 5. This menu contains the settings of the QAM modulator. Enter appropriate values for Modulation and Frequency (output). Symbol rate is given by the symbol rate of the received service and can not be changed. Click [Next]. 6. The installation is now completed and a QAM signal program should be present on the RF output. Click [Again] or [Prev] if you want to modify the settings. 7

7. For advanced settings click [Options] and [Receiver] 8. Under the menu [Receiver] you can change settings for LNB Voltage, DiSEqC and IQ Convention (non-inverted, inverted or auto). Click [OK] [Options] and then [Modulator]. 9. The [Modulator] menu allows you to choose Operation (Normal or CW) and the Output level (0 to -31dB). Click [OK], [Status] and [Receiver]. 8

10. In the [Status] menu you can read the signal quality and input level of the received signal. Click [OK] and disconnect your PALM PDA. 9

5. Settings with PC This section describes how to make a first time installation for PC following the step by step instructions below. See to that the control software files delivered on the CD-ROM are installed on your PC. Connect the ESC-100 to a DC power supply (ESP-100 or EPP-100). Then connect your PC to the ESC-100 with a null modem cable from a serial port on the PC to the RS-232 port on the ESC-100. Start the controller software. After choosing the correct COM port and pressing OK, following menu should appear. 10

Below you find a description of the different settings. 1.RECEIVER First select the appropriate LNB type, Fixed or Universal and then specify the polarization. The LNB Power should normally be set to Auto if you have selected Universal LNB. The Inverted Spectrum setting sometimes has to be changed when the signal is from the C-band. Then type in the transponder frequency and the symbol rate. Write the settings by pressing [Program Receiver]. If the above settings is correct and the signal quality is good enough (ie, the receiver is locked) the signal quality and signal level will be displayed. 2.MODULATOR Select desired QAM constellation (16-, 32-, 64-, 128- or 256-QAM) from the pull down menu. For easy measurement of output level (e.g. with a spectrum analyzer) the CW option can be used. This will make the ESC-100 output a continuous wave (carrier only) instead of QAM modulated data. NOTE! This level should usually be adjusted to -10dB compared to the level of analouge signals in the network. Choose the wanted output centre frequency from the channel table in the pull down menu or enter any frequency in the text box. Valid centre frequencies are 50-858 MHz in steps of 250 khz. After a frequency has been chosen, press [Program Frequency]. The default output level of 102 dbµv can be decreased with 31dB in steps of 1dB. This is done by selecting different values in the Output Level pull down box. The Output Baud Rate is displayed below the Output Level pull down Box. This value is fixed and is given by the Symbol Frequency of the selected service. 3.SYSTEM The COM port that is used can be changed by choosing a different one in the pull down menu. Connection status is also displayed, a green light indicates connected and a red light indicates not connected. To see various information about the unit and the software version, press the information [i]. The help menu [?] will be accessible in later software versions. 11

6. Installation The ESC-100 can be installed either as a stand alone unit or in a base unit (EBU-100). Before connecting power to the ESC-100, make sure that all other connections have been made. A coaxial cable of good quality with a F-connector should be connected from the LNB to the RF input and another one from the RF output to the cable TV network. Connect a power supply and make all necessary settings as described in section 4 and 5. Installation in a base unit with 10 modules and common power supply. Installation on wall as a stand alone unit with single power supply (ESP-100) and a wall mount plate. Accessories EPP-100 power supply 100W, 11 outputs Wall mount plate DC-cable for EPP-100 ESP-100 Power supply 15W 1 output EBU-100 Base unit for 10 modules and power supply 12

7. Technical specification ESC-100 High quality CATV QPSK to QAM transmodulator Description The ESC-100 is a QPSK to QAM trans-modulator for digital cable distribution. It is designed for use on both VHF and UHF so that every available channel on a cable TV network can be used. Control and Settings The unit is controlled via an RS-232 connector on the front. Software is included for control via a PC or a Palm PDA (RS-232). QPSK Satellite Receiver RF Output RF out connector Type F female, 75 ohm RF out frequency 50-858 MHz (center frequency) RF out level 102 dbuv (±3) db (50-858 MHz) and ±1 db over temperature (0-50 C) Attenuator range 0 to -31dB in 1 db steps Spurious suppression > 50 db (1 1200 MHz) Miscellaneous Input Frequency 950 2150 MHz LNB connector Type F female, 75 ohm Input Level -60 to -25 dbm Spectral inversion Yes, selectable LNB voltage Auto, Off, 13V, 18V programmable.400 ma max. (short circuit protected) 22kHz to LNB Auto, On or Off programmable Symbol Rate 2 45 Mbaud/s DVB compliant DVB-S (EN 300 421) Power supply Power consumption Dimensions Weight Controller Control connector Operating temp. 6 9 VDC < 6 W (excl. LNB feed) Max. 14 W with maximum LNB feed 165x105x20 mm (excl. connectors), panel 35x128 mm (7TE x 3HE) Approx. 330 g Palm hand computer or PC (software included) 9 pin male D-sub 0 to +50 C QAM Cable Modulator QAM modes 16, 32, 64, 128 and 256 QAM Test mode Continuous Wave (carrier only) Symbol rate 4 7.2 Mbaud/s MER (at RF out) > 37 db for 256-QAM DVB compliant DVB-C (EN 300 429) This specification may be subject to change without notice. 13

8. Declaration of Conformity Declaration of Conformity EC Directives ESC-100 fulfills relevant parts of the directives and standards as below. Directives: Electro magnetic compability directive (EMC) 89/339/EEC Low voltage directive (LVD) 73/23/EEC CE-marking directive 93/98/EEC Standards: EMC: Emission - EN61000-6-3:2001 Immunity - EN61000-6-1:2001 Safety : EN 60 950-1:2001 The document for Declaration of Conformity you will find at www.a2b.se. Further information at www.a2b.se. 14

Notes 15

Notes 16

Notes 17

Notes 18

ANVÄNDARMANUAL ESC-100 Professionell CATV QPSK till QAM transmodulator Svenska design for TV 19

Innehåll 1. Introduktion 2. Uppackning av enheten 3. Kontakter och indikeringar 4. Inställningar med PALM PDA 5. Inställningar med PC 6. Installation 7. Teknisk specifikation 8. Declaration of Conformity 20 Svenska

1. Introduktion Tack för att ni har valt en A2B Electronics produkt. Denna produkt är utvecklad för att ni som kund skall vara nöjd med dess prestanda och funktioner under många år. ESC-100 är en högkvalitativ professionell CATV QPSK till QAM transmodulator för användning i alla slags Kabel-TV och SMATV-nät. Alla funktioner är integrerade i en extremt kompakt enhet. ESC-100 innehåller en högkvalitativ QAM-modulator för direkt anslutning till ett Kabel-TV/SMATV-nät. Denna manual innehåller installations- och inställningsanvisningar. För ytterligare assistans, kontakta din lokala handlare eller vår tekniska support: A2B Electronics AB Telefon: +46 (0)141 229115 E-post: support@a2b.se Besök också vår hemsida på www.a2b.se för ytterligare support. 21 Svenska

2. Uppackning av enheten ESC-100 levereras med all nödvändig mjukvara för att kunna göra alla inställningar. Filerna finns på den medföljande CD:n och som kontrollenhet kan antingen en PC eller en PALM handdator användas. Följande delar skall finnas i paketet: Antal Beskrivning 1 QPSK till QAM transmodulator ESC-100 1 CD med bruksanvisning och kontrollmjukvara 1 Denna manual i tryckt version 4 Skruvar till frontpanelen Varje enhet är kvalitetskontrollerad av oss före leverans men om något skulle fattas i paketet kontakta vår support service (se sidan 21 för kontakt). 22 Svenska

3. Kontakter och indikeringar Spänningsindikator Felindikering, QPSK Felindikering, QAM RS-232 port för kontroll och inställningar RF ut Spänning in LNB in Spänningsindikator Felindikering, QPSK Felindikering, QAM Grön lampa indikerar att enheten är spänningssatt. Röd lampa indikerar att insignalen är felaktig. Röd lampa indikerar att utsignalen är felaktig. RS-232 port för kontroll Serieport för anslutning till PC eller Palm och inställningar (kontrollmjukvara finns på den bifogade CD:n). LNB in RF ut Spänning in Anslut LNB-kabeln till denna ingång. Utgång till Kabel-TV/SMATV-nät. Anslutning av DC-spänning (6-9V 2A). 23 Svenska

4. Inställningar med PALM handdator Detta avsnitt beskriver hur man gör en steg för steg inställning av mottagaren. Se till att de medföljande mjukvarorna är installerade på din PALM. För anvisningar om hur detta görs se manualen till din handdator. 1. Anslut ESC-100 till en DC spänningskälla (ESP-100 eller EPP-100). Anslut därefter din PALM handdator till ESC-100 med en PALM Hotsync kabel till RS-232 kontakten på ESC-100. 2. Klicka på ESC ikonen under A2B Control menyn på din PALM. 3. En välkomstmeny enligt nedan startar installationen. Klicka på [Next]. 24 Svenska

4. Denna meny innehåller tunerinställningar och val av LNB typ. Ange önskade värden för Transponderfrekvens, Symbolhastighet och Polarisation och klicka på [Next]. Nu kommer du att se att enheten låser in och värdet för Eb/No. 5. Denna meny innehåller inställningar för QAM modulatorn. Mata in önskad Modulation och Utfrekvens. Symbolhastigheten bestäms av Symbol frekvensen från vald service och kan ej ändras. Klicka på [Next]. 6. Installationen är nu klar och en QAM signal skall nu finnas på mottagarens RF-utgång. Klicka på [Again] eller [Prev]om du vill ändra något i dina inställningar. 25 Svenska

7. För att gå vidare med Avancerade inställningar så klickar du på [Options] och på [Receiver]. 8. [Receiver] menyn tillåter ändring av LNB spänning, DiSEqC och om signalen innehåller inverterat spektrum (IQ Convention) kan denna väljas som Non-inverted, Inverted eller Auto. Klicka på [OK], [Options] och [Modulator]. 9. I [Modulator] menyn kan du ändra Operation mellan Normal eller CW (bärvåg) samt dämpa utnivån (0 till -31dB). Klicka på [OK], [Status] och [Receiver]. 26 Svenska

10. I [Status] menyn kan du läsa signal kvalitet och ingångsnivå för den mottagna signalen. Klicka på [OK] och ta bort anslutningen till din PALM handdator. 27 Svenska

5. Inställningar med PC Detta kapitel beskriver hur man gör alla inställningar av ESC-100 via en PC. Se till att kontrollmjukvaran är installerad på din PC innan du börjar. Denna finns på den medföljande CD-rom-skivan. Anslut er ESC-100 till PC:ns serieport med en nollmodemskabel. Anslut matningsspänning (via ESP-100 eller EPP-100) och starta programmet. När programmet startats upp, välj COM-port och tryck OK. Efter några sekunder har huvudprogrammet startats upp och ESC-100:s inställningar lästs ut. 28 Svenska

Nedan följer en beskrivning av de olika inställningsmöjligheterna. 1.RECEIVER Ställ först in inställningarna för LNB-matningen, Fixed eller Universal och ställ sedan in polarisation. LNB Power skall normalt stå på Auto om du använder ett universal-lnb. Inverted Spectrum måste ibland ändras ifall mottagning av C-band sker. Välj sedan Transponderfrekvens och Symbolhastighet. Tryck på [Program Receiver] för att de nya inställningarna skall gälla. Om receivern är rätt inställd och signalen är bra kommer kvaliteten och styrkan på signalen att visas. 2.MODULATOR Välj önskad QAM-läge (16-, 32-, 64-, 128- eller 256-QAM). För att på ett enkelt sätt kunna mäta utnivån (tex med hjälp av en spektrumanalysator) kan det s.k. CW-läget användas. I detta läge sänds enbart en bärvåg med motsvarande amplitud ut. OBS! Normalt sett ställs utnivån 10dB lägre än analoga kanaler i nätet. Välj sedan önskad utfrekvens eller kanal. Denna anges som centerfrekvens. Kanaltabellen som finns är CCIR E/S. Möjliga frekvenser är 50 till 858 MHz i steg om 250 khz. Efter att en frekvens eller kanal valts, tryck på [Program Frequency] för att inställningarna skall börja gälla. Utnivån kan sänkas med 31 db från den förinställda nivån om 102 dbuv i steg om 1 db. Symbolhastigheten som sänds ut kan avläsas längst ner. Denna kan ej ändras utan är bestämd av den mottagna signalens Symbolhastighet. 3.SYSTEM Under System kan man byta COM-port och se dess status (grönt indikerar att enheten är ansluten, röd att något är fel). För att se mjukvaruversion, serienummer och annan information klicka på [i]. Hjälp-menyn [?] kommer att implementeras i senare mjukvaruversioner. 29 Svenska

6. Installation ESC-100 kan installeras antingen som en helt fristående enhet eller tillsammans med andra moduler i en basenhet (EBU-100). Innan ni ansluter matningsspänning till enheten, tillse att alla andra anslutningar är gjorda. Använd en antennkabel av god kvalitet med F-kontakt för anslutning till antenningången och antennutgången på ESC-100. Anslut matningsspänning och gör alla nödvändiga inställningar enligt kapitel 4 eller 5. Installation i basenhet med 10 moduler och gemensam strömförsörjning. Installation på vägg som fristående enhet med enkel strömförsörjning och ett väggfäste. Tillbehör EPP-100, nätdel 100W, 11 utgångar Väggfäste DC-kabel för EPP-100 ESP-100, nätdel 15W, 1 utgång EBU-100, basenhet för 10 moduler & nätdel 30 Svenska

7. Teknisk specifikation ESC-100 Högkvalitativ CATV QPSK till QAM transmodulator Beskrivning ESC-100 är en QPSK till QAM transmodulator för digital kabeldistribution. Den fungerar på både VHF och UHF och är fullt grannkanalsduglig så att varje ledig kanal i nätet kan nyttjas. Inställningar QAM Modulator QAM-lägen 16, 32, 64, 128 och 256 QAM Testläge Continous Wave (endast bärvåg) Symbolhastighet 4 7.2 Mbaud/s MER (vid RF ut) > 37 db för 256-QAM DVB-kompabilite DVB-C (EN 300 429) RF Utgång Programmering och inställningar av enheten görs via serieporten på framsidan. Mjukvara för PC och Palm bifogas. QPSK Satellit Mottagare Infrekvens 950 2150 MHz Kontakt Typ F, hona, 75 ohm Ingångsnivå -60 till -25 dbm Spektruminvertering Ja, ställbart LNB-spänning Auto, Off, 13V, 18V, ställbart. 400 ma max. (kortslutningsskyddad) 22kHz till LNB Auto, On eller Off, ställbart Symbolhastighet 2 45 Mbaud/s DVB kompabilitet DVB-S (EN 300 421) Kontakt Utfrekvens Utnivå 6 9 VDC < 6 W (exkl. LNB-matning) Max 14 W med max LNBmatning 165x105x20 mm (exkl. kontakter), panel 35x128 mm (7TE x 3HE) C:a 330 g Palm PDA el. PC (mjukvara medföljer) 9-pinnars D-sub, hane 0 till +50 C Störningsundertryckning Övrigt Matningsspänning Effektförbrukning Mått Vikt Kontrollenhet Kontrollport Driftstemperatur Typ F, hona, 75 ohm 50-858 MHz (centerfrekvens) 102 dbuv (±3) db (50-858 MHz) och ± 1 db över temperatur (0-50 C), variabel 0 till -31dB i 1 db steg > 50 db (0 1200 MHz) Denna specifikation kan komma att ändras utan föregående varning. 31 Svenska

8. Declaration of Conformity Declaration of Conformity EC Directives ESC-100 uppfyller de relevanta delarna av nedanstående direktiv och standarder. Direktiv: Electro magnetic compability directive (EMC) 89/339/EEC Low voltage directive (LVD) 73/23/EEC CE-marking directive 93/98/EEC Standarder: EMC: Emission - EN61000-6-3:2001 Immunity - EN61000-6-1:2001 Safety : EN 60 950-1:2001 Det fullständiga dokumentet för Declaration of Conformity återfinnes på www.a2b.se. Se vidare på www.a2b.se. 32 Svenska

Noteringar 33 Svenska

Noteringar 34 Svenska

Noteringar 35 Svenska