EN SV. Mifare Reader MF1040 & MF1050. HW version 1.6 or later. Installation Note. Siemens AG



Relevanta dokument
EN SV. Mifare Reader. MF1040e & MF1050e. Installation Note. Vanderbilt International (IRL) Ltd.

Ersättning styrkort GOLD, stl 1-3, Version 1-3/ Replacement control circuit board GOLD, sizes 1-3, Version 1-3

RB500 EM. Card reader RB500 Installation Guide. Siemens AG

Beijer Electronics AB 2000, MA00336A,

MCP-16RC, Air Purification

Support Manual HoistLocatel Electronic Locks

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK

Får endast utföras av behörig personal. May only be carried out by authorized electrician

2.1 Installation of driver using Internet Installation of driver from disk... 3

nwind and nwind-race transducer Twin Fin Installation Manual English Installationsmanual Svensk

GOLD SD Med styrenhet/with control unit. Fläkt 1A/B/ Fan 1A/B. Fläkt 2A/B/ Fan 2A/B. Fläkt/ Fan. Utan filter/ Without filter

Vanliga frågor om Duocom (för installatör eller reparatör) GB Frequently asked questions about Duocom (for installer or repairman)



säkerhetsutrustning / SAFETY EQUIPMENT

GOLD SD Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1. Fläkt 2/ Fan 2. Med filter/ With filter Filter

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

IRAB Mottagare sida 2-5 Tele Radio AB Mottagare sida 6

Product configurations Produire configuration Produkt konfigurationen Producto configuraciones Produkt konfigurationerna

IM10. Installation Note ENGLISH. Before you start the installation, make sure that the following material is available:

Assembly instruction Kit 200

Windlass Control Panel v1.0.1

MAC Ope ra tor Terminal

Digital Personvåg MANUAL H

PRESS FÄLLKONSTRUKTION FOLDING INSTRUCTIONS

FORTA M315. Installation. 218 mm.

MK-2000 Serien. Magnetkontakter

Kortläsare PT Kompakt beröringsfri kortläsare (MIFARE ) Diskret design Ingjuten elektronik

PRESS FÄLLKONSTRUKTION FOLDING INSTRUCTIONS

Företagsnamn: Grundfos Skapad av: Magnus Johansson Tel: +46(0) Datum:

GOLD SD eff.var./cap.var.120-1

Installationsguide. EG200 Multi WAN Residential Gateway. v

Anvisning för Guide for

Installationsguide. DG200 Multi WAN Residential Gateway V

Fig. 2: Inkoppling av lindningarna / Winding wiring diagram

E terminals, Installation E terminals, Manual. Manual IFC 128E. Beijer Electronics AB 2000

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter

INDUKTIV SLINGDETEKTOR INDUCTIVE LOOP DETECTOR

Slangupprullare Hose reels

Montageanvisning Airway system 1000/1500 Assembly instruction Airway system 1000/1500

Monteringsanvisning Nödutrymningsbeslag ASSA 179E

Users manual Bruksanvisning Gebrauchanweisung Guide d instructions

INSTALLATION INSTRUCTIONS

GOLD SD 100, eff.var./cap.var. 1

GOLD SD 100, eff.var./cap.var. 2

Alias 1.0 Rollbaserad inloggning

InstalationGuide. English. MODEL:150NHighGain/30NMiniUSBAdapter

Installation Instructions

Monteringsanvisning Podie T 4100 K

GOLD SD/CX 120, eff.var./cap.var. 2

Quick Start Guide Snabbguide

1. Unpack content of zip-file to temporary folder and double click Setup

BBT057/ BBC057 BBCD057/ BBT057-NL HOLDEN COLORADO 9/2016+ HOLDEN TRAILBLAZER WD & 4WD Models

M850-LTHN. Installationsmanual och användarhandbok

MAC Ope ra tor Terminal

GOLD PX 04/05, 07, 08 eff.var./cap.var. 1, 11 eff.var./cap.var. 1

GOLD SD 60. Med styrenhet/with control unit. Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1.

Panel Source (Hona) (LSP***PS**), Panel Drain (Hane) (LSP***PD**), Line Source (Hona) (LSP***LS**), Line Drain (Hane) (LSP***LD**),

Med styrenhet (i undre plan)/with control unit (in lower level) Säkerhetsbrytare/ huvudströmbrytare/ Safety switch/ main switch

GOLD SD/CX 120, eff.var./cap.var. 1

Montageanvisning Airway system 1000/1500 Assembly instruction Airway system 1000/1500

CanCom Bluetooth BLUETOOTH V5.6. Specifikation Specification LED. transceiver

ARC 32. Tvättställsblandare/Basin Mixer. inr.se

GOLD SD 40/50, eff.var./cap.var. 2

manual Facial spa Art nr: Rubicson

Boiler with heatpump / Värmepumpsberedare

Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

SE/GB.ELSD5060E

GOLD SD 04/05, 07/08, 11 eff.var./cap.var. 1

Discovery FSQ, IAA Utgåva/Edition 11. SE Habo. Klass 2 IAA FSQ-I 26W. 4 mm c c mm N L

EN SV SK6. Security Unit. Installation manual. Siemens AB. Security Products

DAMPER EQAZ-12, EQAZ-13, STAZ-30, STBZ-30

SVENSK STANDARD SS-EN ISO 19108:2005/AC:2015

Digital Personvåg MANUAL H

Magnetkontakt. MK-4000 Serien

English Svenska. Installation. Guide. XG6846 Broadband Switch

, fukt- och temperaturdetektor Modbus RTU, trafikljus

SOLAR LIGHT SOLUTION. Giving you the advantages of sunshine. Ningbo Green Light Energy Technology Co., Ltd.

INSTALLATIONSANVISNING INSTALLATION MANUAL MM-61 ST

Monteringsanvisning Installation instructions

GOLD SD 100, eff.var./cap.var. 2

Styrteknik 7.5 hp distans: E-1000 och E-Designer

Styrteknik: Binära tal, talsystem och koder D3:1

BBT042/ BBC042/ BBCD042 NISSAN NAVARA D40 V STX & PATHFINDER R WD & 4WD Models

TYLÖ SAUNA HARMONY PRO

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

AXCALL. ADI-611/616/608 Ver 1.7

Utfärdad av Compiled by Tjst Dept. Telefon Telephone Datum Date Utg nr Edition No. Dokumentnummer Document No.

SE/GB.ELSD5060E

Reservdelskatalog Parts Catalogue COMBI 40 AE /S15 - Season 2017

IFC MC. Manual. English, Svenska MA00281C

2.45GHz CF Card Reader User Manual. Version /09/15

Programmera Avant 5 med PC mjukvara

This manual should be saved! EcoFlush Manual. Wostman 2018:2

Manual för termometer med 2 växlande kontakter - svenska, sida 2-3. Manual for thermometer with 2 change over contacts - English, page 4-5

FIX LED-LYSRÖRSARMATUR MED AKRYLKÅPA IP44

3 Kontaktdon. Contact Fittings. Kontaktdon för Cu-rör Contact Fitting for Cu-pipe

Kamrör / Ribbed pipe radiator

IR3000, IR4500, IR6000

Transkript:

EN SV Mifare Reader MF1040 & MF1050 HW version 1.6 or later Installation Note MF1040 MF1050 Siemens AG

ENGLISH MF1040 & MF1050 Installation Description MF1040 and MF1050 is a compact Smartcard reader using Mifare reading technology. By using Mifare high security can be achieved by means of password-protected cards. The card can also be used in several applications aside form security. With a PIN-code (MF1050) the level of security is extended even further. The unit can be mounted in a standard flush fitting back box or flush-mounted (frame supplied). Details of ordering Type MF1040 MF1050 Item Number GBI: SE2:21-551 Siemens: S54201-Z56-A1 GBI: SE2:21-552 Siemens: S54201-Z55-A1 Wiring to Omnis 2010 E2V Technical data Operating voltage: 8-24 V DC Current consumption: 70 ma 12 VDC (max 140 ma) Indicators: 4 x LED, blue, red, yellow, green 1 x Buzzer Keypad: 12, 0-9, A and B Connections: 8 pole, fixed terminal block Tamper switch: No 2010: loop can be connected via FBK Dimensions (W x H x D): 110 x 100 x 35 mm (including frame) Weight: 0.2 kg Operating -20 to +50 C temperature: IP rating: IP67 Cabling: EKKX / ELLXEB 4x2x0,5 Max cable length: 25 m Interface: Clock & Data. Note! Connect between 0V and Sense. Communication: Clock&Data for Omnis 2010 Wiegand for Entro & SiPass integrated. MK2 Swipe reader for Granta. Reading technology: 13.56 MHz Mifare Classic ISO14443A Reading: Selectable between Serial or Sector (Programming via programming card) Mounting 1. When needed use the supplied spacers behind the mounting frame. 2. Connect the cable and mount the reader to the mounting frame by pressing it downwards so the lower edge hooks into the frame. 3. Secure the reader with the supplied screw (tools supplied) and mount the cover with a heavy pressure. Surface mounted Flush mounted 1. Sector reading 2. Serial reading 3. No jumper = Serial number reading for Omnis 2010 2

ENGLISH - MF1040 & MF1050 Installation Wiring to Entro DC12/DC22 1. Sector reading 2. Serial reading 3. No jumper = Serial number reading for Entro. 4. Reader connections for communication and power supply. Note that the link J4 must be placed on Vin. This wiring ensures that the voltage to the reader is rectified. 5. Note! Connection between 0V and Sense applies. Programming Entro MF1040/1050 with firmware version 1.6 or later is delivered with a factory setting for 32 bit Wiegand. This means that the following settings must be entered in the Installer program. Card reader settings - Custom parameters - Start position 1 - Number of digits 10 - # # # # # # # # # # 3

ENGLISH MF1040 & MF1050 Installation Wiring to SiPass integrated If SiPass integrated ADD5100 (DRI), ADS5200 (SRI) or ADE5300 (ERI) is used as door controllers for the MF1040/MF1050 the following wiring should be used. MF1040/MF1040 DRI / SRI / ERI +V 12V Data D0 Clock D1 Sense Shortcut to 0V Buzz 0V 0V Red RED Grn GRN A B Migrating from Entro to SiPass integrated There is a possibility to migrate an Entro installation into a SiPass integrated system. Normally this migration means that the reader installation is already done and kept as is. Rather it is the system architecture that is changed. So the MF1040/MF1050 readers can be kept but there are two ways how the controllers are installed. DC12/DC22 directly wired to AC5100 (ACC) Any SR34i is re-programmed to an ACC-X. AC5100 (ACC) and DC12/DC22 The migration is initially carried out according to the Entro Integration manual supplied with the SiPass integrated system. ACC-X and DC12/DC22 Keep Entro equipment but order new ACC-X firmware (for 4, 8, 16 or 32 doors) and substitute the firmware in the Entro Segment controller to become an ACC-X. The MF1040/MF1050 is wired as previous Entro page. Indicators Standby mode: Blue LED. Void card: Red LED for three sec. & short sound. Access granted: Red LED for three sec. & short sound followed by green LED. Any key press: Short sound. Waiting for PIN: Amber/red blinking / amber/blue blinking& short sound Wiegand configuration 32 bit card data No parity or start/stop bits. All bits into the card number Below is the software settings in SiPass integrated: AC5100 FLN + FLN - DC12/DC22 3 - COM A 4 - COM B +12-24V and 0V from power supply. Resistors on last DC in chain. 4

ENGLISH - MF1040 & MF1050 Installation Wiring to Granta Controller 4422 If the reader is used in the Granta system the following wiring applies: MF1040/MF1050 Granta 4422 12V +V Data D0 Clock D1 Sense Shortcut to 0V Buzz 0V 0V Red R GN G A B Configuration Type: MK2 Swipe Reader Interface number: 309 Below are the Granta software settings: Indicators Standard state: Access granted: Red LED. Green LED. 5

SVENSKA - MF1040 & MF1050 Installation Beskrivning MF1040 och MF1050 är en kompakt beröringsfri Smartcardläsare som nyttjar Mifare lästeknologi. Med Mifare uppnås hög säkerhet genom att korten är lösenordskyddade. Kortet kan dessutom användas i fler applikationer än för säkerhet. Med PIN-kod (MF1050) förstärks säkerheten ytterligare. Enheten monteras infällt i standard väggdosa eller utanpåliggande (ram medföljer). Orderdetaljer Typ MF1040 MF1050 Art nr GBI: SE2:21-551 Siemens: S54201-Z56-A1 GBI: SE2:21-552 Siemens: S54201-Z55-A1 Tekniska data Strömförsörjning: 8-24 V DC Strömförbrukning: 70 ma 12 VDC (max 140 ma) Indikeringar: 4 x lysdioder (blå, röd, gul, grön) 1 x Summer Knappar: 12 st, 0-9, A och B Anslutningar: 8 pol, fast plint Sabotagekontakt: Nej 2010: Slinga kan anslutas via FBK Mått (B x H x D): 110 x 100 x 35 mm (inkl ram) Vikt: 0,2 kg Temp.område: -20 till +50 C Kapslingsklass: IP67 Anslutningskabel: EKKX / ELLXEB 4x2x0,5 Max kabellängd: 25 m Gränssnitt: Clock & Data OBS! Anslut mellan 0V och Sense. Kommunikation: Clock&Data för Omnis 2010 Wiegand för Entro & SiPass integrated. MK2 Magnetkortläsare för Granta. Läsarteknologi: 13.56 MHz Mifare Classic ISO14443A Kortläsning: Valbart mellan Serial eller Sector (Programmering via programmeringskort) Montage 1. Använd vid behov de medföljande distansbrickorna bakom monteringsramen. 2. Anslut kabeln och montera kortläsaren på monteringsramen genom att trycka den nedåt så att nederkantens hakar får grepp i ramen. 3. Skruva fast kortläsaren med den medföljande oförväxlingsbara skruven (verktyg medföljer) och montera täckbrickan med ett kraftigt tryck. Utanpåliggande Infällt montage Inkoppling till Omnis 2010 E2V 1. Sektorläsning 2. Serienummerläsning 3. Ingen bygel = Serienummerläsning för Omnis 2010 6

SVENSKA - MF1040 & MF1050 Installation Inkoppling till Entro DC12/DC22 1. Sektorläsning 2. Serienummerläsning 3. Ingen bygel = Serinummerläsning för Entro 4. Anslutning till läsare för kommunikation och spänning. Observera att bygel J4 måste sättas på Vin. Denna inkoppling säkerställer att spänningen till läsaren är likriktad. 5. OBS! Anslutning mellan 0V och Sense. Programmering Entro MF1040/1050 med programversion 1.6 eller senare levereras med en fabriksinställning på 32 bit Wiegand. Det innebär att man ska ange följande inställningar i Installatörsprogrammet. Kortläsarinställningar - Egen inställning - Start position 1 - Antal siffror 10 - # # # # # # # # # # 7

8

Issued by Siemens AG Siemensallee 84 D-76187 Karlsruhe www.buildingtechnologies.siemens.com Document no. 82348-2 Edition 09.12.2010 2010 Copyright by Siemens AG Data and design subject to change without notice. Supply subject to availability.