Installation Instructions

Relevanta dokument
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

BBT057/ BBC057 BBCD057/ BBT057-NL HOLDEN COLORADO 9/2016+ HOLDEN TRAILBLAZER WD & 4WD Models

Instruction Manual. Svenska, English. Power Bank. Model: PRBN

SkillGuide. Bruksanvisning. Svenska

SAFETY PRECAUTIONS SPECIFICATIONS

RADIATION TEST REPORT. GAMMA: 30.45k, 59.05k, 118.8k/TM1019 Condition D

Installation Instructions

SVENSK STANDARD SS-ISO :2010/Amd 1:2010

Remote control Fjärrströmbrytare / Fjernstrømbryter

Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

Får endast utföras av behörig personal. May only be carried out by authorized electrician

Installation Instructions

Dokumentnamn Order and safety regulations for Hässleholms Kretsloppscenter. Godkänd/ansvarig Gunilla Holmberg. Kretsloppscenter

Discovery FSQ, IAA Utgåva/Edition 11. SE Habo. Klass 2 IAA FSQ-I 26W. 4 mm c c mm N L

Installation Instructions

Installation Instructions

Accepterad monteringsanvisning 2016:1. Metris (RSK: ) Metris S (RSK: ) Metris (RSK: )

SAFETY PRECAUTIONS SPECIFICATIONS

INDUKTIV SLINGDETEKTOR INDUCTIVE LOOP DETECTOR

BBT042/ BBC042/ BBCD042 NISSAN NAVARA D40 V STX & PATHFINDER R WD & 4WD Models

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) 1 (12)

Bathtub Filler CN EN. TBP02201 Type / TBP02202 Type. Installation Manual. Continued on the back cover

SVENSK STANDARD SS-ISO 8734

PFC and EMI filtering

ARC 32. Tvättställsblandare/Basin Mixer. inr.se

Design Service Goal. Hantering av demonterbara delar som ingår i Fatigue Critical Baseline Structure List. Presentatör

Teknisk support finns tillgänglig Måndag-Fredag 08:00-16:30. Övrig dokumentation finns tillgänglig på Teletecs hemsida -

SVENSK STANDARD SS-EN ISO :2009/AC:2010

Användarhandbok. USB Charging Dock DK52

CanCom Bluetooth BLUETOOTH V5.6. Specifikation Specification LED. transceiver

Windlass Control Panel v1.0.1

Beijer Electronics AB 2000, MA00336A,

Produktens väg från idé till grav

FORTA M315. Installation. 218 mm.

Accepterad monteringsanvisning 2016:1

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S (RSK: ) 1 (12)

* _0817* Drivsystemsteknik \ Drivsystemsautomation \ Systemintegration \ Service. Ändringar. MOVIMOT MM..D med växelströmsmotor DT/DV

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S 100 CoolStart (RSK: )

Användarhandbok. MHL to HDMI Adapter IM750

DAMPER EQAZ-12, EQAZ-13, STAZ-30, STBZ-30

Trefasmätningar. Ellära 2 Laboration 4. Laboration Elkraft UMEÅ UNIVERSITET Tillämpad fysik och elektronik Dan Weinehall.

Företagsnamn: Grundfos Skapad av: Magnus Johansson Tel: +46(0) Datum:

District Application for Partnership

säkerhetsutrustning / SAFETY EQUIPMENT

Isolda Purchase - EDI

Schenker Privpak AB Telefon VAT Nr. SE Schenker ABs ansvarsbestämmelser, identiska med Box 905 Faxnr Säte: Borås

Accepterad monteringsanvisning 2016:1. Ecos M CoolStart (RSK: ) Ecos L CoolStart (RSK: ) 1 (12)

Ackrediteringens omfattning

PRESS FÄLLKONSTRUKTION FOLDING INSTRUCTIONS

Användarhandbok. USB Charger UCH20

Alias 1.0 Rollbaserad inloggning

81152 TRANSFER CASE SHIFT HANDLE


Fiat » Fiat Panda / 4x4 2003» Fiat Panda 4x4 Climbing / 4x4 Cross 20033»

Support Manual HoistLocatel Electronic Locks

nwind and nwind-race transducer Twin Fin Installation Manual English Installationsmanual Svensk

Det här med levels.?

F-ARI. Nya självtestande jordfelsbrytare med automatiska testfunktioner

Your No. 1 Workout. MANUAL pro

PRESS FÄLLKONSTRUKTION FOLDING INSTRUCTIONS

SVENSK STANDARD SS-ISO 2338

Presenter SNP6000. Register your product and get support at SV Användarhandbok

DSAB Spettrobot Modell SPRAYROD

STARTRELÄ PRODUKTINFORMATION

BBT014/ BBC014/ BBCD014 PJ & PK FORD RANGER WD & 4WD Models

Spotlight Set Spotlightset / Spotlightsett

2.45GHz CF Card Reader User Manual. Version /09/15

Swedish framework for qualification

Quick Start. English Svenska PRIMACY. Printing settings and winsign

Webbregistrering pa kurs och termin

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) Focus 100 CoolStart (RSK: ) (RSK: )

Monteringsanvisning Nödutrymningsbeslag ASSA 179E

SVENSK STANDARD SS-EN ISO 19108:2005/AC:2015

Installation Instructions

Materialplanering och styrning på grundnivå. 7,5 högskolepoäng

Quick Start. English Svenska. Moca

Surfaces for sports areas Determination of vertical deformation. Golvmaterial Sportbeläggningar Bestämning av vertikal deformation

SUZUKI GRAND VITARA 3P CITY 2011»

Ersättning styrkort GOLD, stl 1-3, Version 1-3/ Replacement control circuit board GOLD, sizes 1-3, Version 1-3

Manhour analys EASA STI #17214

SVENSK STANDARD SS-ISO 8779:2010/Amd 1:2014

INVERTER MULTIPROCESS MIG/MAG-TIG-MMA

FÖRBERED UNDERLAG FÖR BEDÖMNING SÅ HÄR

BRUKSANVISNING. Oscilla 910

Tentamen i Inbyggda System ( Embedded System )

SVENSK STANDARD SS

Schenker Privpak AB Telefon VAT Nr. SE Schenker ABs ansvarsbestämmelser, identiska med Box 905 Faxnr Säte: Borås

Transkript:

Installation Instructions (Cat. No. 1794-OW8) 3 7 1 English 2 6 4 5 Module Installation This module mounts on a 1794 terminal base unit. 1. Rotate keyswitch (1) on terminal base unit (2) clockwise to position 9 as required for this type of module. 2. Make certain the flexbus connector (3) is pushed all the way to the left to connect with the neighboring terminal base/adapter. You cannot install the module unless the connector is fully extended. 3. Make sure that the pins on the bottom of the module are straight so they will align properly with the connector in the terminal base unit. 4. Position the module (4) with its alignment bar (5) aligned with the groove (6) on the terminal base. 5. Press firmly and evenly to seat the module in the terminal base unit. The module is seated when the latching mechanism (7) is locked into the module. FLEX I/O is a trademark of Rockwell Automation

2 FLEX I/O 8 Output Relay Module! ATTENTION: Remove field-side power before removing or inserting this module. This module is designed so you can remove and insert it under backplane power. When you remove or insert a module with field-side power applied, an electrical arc may occur. An electrical arc can cause personal injury or property damage by: sending an erroneous signal to your system s field devices causing unintended machine motion causing an explosion in a hazardous environment Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance. European Union Directive Compliance If this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EMC Directive This product is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) and the following standards, in whole or in part, documented in a technical construction file: EN 50081-2 EMC Generic Emission Standard, Part 2 Industrial Environment EN 50082-2 EMC Generic Immunity Standard, Part 2 Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131 2 Programmable Controllers, Part 2 Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the following Allen-Bradley publications: Industrial Automation Wiring and Grounding Guidelines For Noise Immunity, publication 1770-4.1 Automation Systems Catalog, publication B111 This equipment is classified as open equipment and must be mounted in an enclosure during operation to provide safety protection.

FLEX I/O 8 Output Relay Module 3 ATTENTION: Do not attempt to increase load current or wattage capability beyond the maximum rating by connecting 2 or more outputs in parallel. The slightest variation in relay switching time may cause one relay to momentarily switch the total load current. Simplified Schematic of Relay Module +24V dc 120V ac 24V dc 48V dc 240V ac 24V dc 120V ac 240V ac Representative Examples of Various Relay Loads Relay Load Contact Wiring 125V dc dc Return Load power can be obtained from a variety of sources, and can range from +5V dc to 240V ac. Make certain that only 24V dc is applied to the module power terminals on the module terminal base ATTENTION: Apply only +24V dc power to the power terminals on the terminal base unit. Make certain that all relay wiring is properly connected before applying any power to the module. ATTENTION: Total current draw through the terminal base unit is limited to 10A. Separate power connections to the terminal base unit may be necessary.

4 FLEX I/O 8 Output Relay Module Wiring to a 1794-TB2 or -TB3 Terminal Base Unit 1. Connect individual output relay contact (customer load) wiring to numbered terminals on the 0 15 row (A) as indicated in the table below. The even numbered terminals are one pole of the relay contacts; the odd numbered terminals are the other pole of the relay contacts. ATTENTION: When using 240V power to a relay, you must connect a snubber across the load. Failure to connect a snubber across the load can result in generation of electromagnetic noise which could disrupt nearby electrical equipment, including your 1794 Flex I/O chassis. Use Allen-Bradley part number 599-KA04 or 1401-NX1. 2. Connect 24V dc return to terminal 16 on the 16-33 row (B). (Terminals 16 thru 33 are internally connected together.) 3. Connect +24V dc power to terminal 34 on the 34 51 row (C). (Terminals 34 thru 51 are internally connected together.) ATTENTION: Apply only +24V dc power to the power terminals on the terminal base unit. Make certain that all relay wiring is properly connected before applying any power to the module. 4. If continuing power to the next terminal base unit, connect a jumper from terminal 51 (+24V dc) on this base unit to terminal 34 on the next base unit. 5. If continuing the dc return to the next terminal base unit, connect a jumper from terminal 33 (24V dc return) on this base unit to terminal 16 on the next base unit.

FLEX I/O 8 Output Relay Module 5 16 16 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 34 Output Relay Contacts (customer loads) 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 1794-TB2 Output Relay Contacts (customer loads) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 34 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 1794-TB3 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 Label placed at top of wiring area. 51 Row A Row B Row C 0 15 16 33 34 51 A B C 0 15 A 16 33 B 34 51 C Row A Row B Row C 1794-TB3S

6 FLEX I/O 8 Output Relay Module Wiring to a 1794-TBN or -TBNF Terminal Base Unit 1. Connect individual relay wiring (customer loads) to even numbered terminals (0 thru 14) on row (B) and odd numbered terminals (1 thru 15) on row (C) as indicated in the table below. (Even numbered terminals are 1 pole of the relay contacts; odd numbered terminals are the other pole of the relay contacts.) ATTENTION: When using 240V power to a relay, you must connect a snubber across the load. Failure to connect a snubber across the load (relay contacts) can result in generation of electromagnetic noise which could disrupt nearby electrical equipment, including your 1794 Flex I/O chassis. Use Allen-Bradley part number 599-KA04 or 1401-NX1. 2. Connect 24V dc return to terminal 16 on row (B). ATTENTION: Apply only +24V dc power to the power terminals on the terminal base unit. Make certain that all relay wiring is properly connected before applying any power to the module. 3. If continuing the dc return bus to the next terminal base unit, connect a jumper from terminal 33 on this base unit to terminal 16 on the next base unit. 4. Connect +24V dc power to terminal 34 on row (C). 5. If continuing dc power to the next terminal base unit, connect a jumper from terminal 51 (+24V dc) to terminal 34 on the next base unit. 16 Even Numbered Terminals 0 thru 14 33 0 2 4 6 8 10 12 14 33 16, 0, 2, 4, 6, 8, 10, 12, 14, 33 B 34 1 3 5 7 9 11 13 15 51 34, 1, 3, 5, 7, 9, 11, 13, 15, 51 C 34 Odd Numbered Terminals 1 thru 15 51 1794-TBN, -TBNF 16

FLEX I/O 8 Output Relay Module 7 Output 1794-TB2, -TB3, -TB3S 1794-TBN, -TBNF Channel Output Terminal Output Terminal 0 1 2 3 4 5 6 7 A = output terminals B = dc return terminals C = power terminals (C 34 and 51 for 1794-TB2; C-34 thru 51 for 1794-TB3, -TB3S) A 0 B 0 A 1 C 1 A 2 B 2 A 3 C 3 A 4 B 4 A 5 C 5 A 6 B 6 A 7 C 7 A 8 B 8 A 9 C 9 A 10 B 10 A 11 C 11 A 12 B 12 A 13 C 13 A 14 B 14 A 15 C 15 B = even numbered output terminals 0 14,; dc return terminals B 16 and B 33 C = odd numbered output terminals 1 15; power terminals C 34 and C 51 Indicators Allen-Bradley RELAY OUTPUT 1794 OW8 9 0 1 2 3 4 5 6 7 A B A = Status Indicators yellow show status of individual outputs. If relay output bit is on, the corresponding output indicator is on. B = Insertable label for writing individual output designations.

8 FLEX I/O 8 Output Relay Module Image Table Memory Map Word Memory Map Dec. Bits (Octal Bits) Description Format Read Input 00 15 (00 17) Not used reserved Write Output 00 07 Relay Output data 00 corresponds to output 0, 01 corresponds to output 1, etc. 0 = Output off 1 = Output on 08 15 (10 17) Not used Dec. 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 (Octal) 17 16 15 14 13 12 11 10 07 06 05 04 03 02 01 00 Write Not used set to 0 O7 O6 O5 O4 O3 O2 O1 O0 Where O = Output number When bit = 0, output is off; when bit =1, output is on

FLEX I/O 8 Output Relay Module 9 1794-OW8 Output Specifications Outputs per Module Module Location Output Voltage Range (load dependent) Output Current Rating (at rated power) Power Rating (steady state) Output Signal Delay Off to On On to Off Specifications continued on next page 1 group of 8 Form A (normally open) electromechanical relays Mounts on 1794-TB2, -TB3, -TB3S, -TBN, and -TBNF Terminal Base Units. When using 1794-TBNF terminal base unit, use 3.0A, 250V ac slow-blow fuses 5 30V dc @ 2.0A resistive 48V dc @ 0.5A resistive 125V dc @ 0.25A resistive 125V ac @ 2.0A resistive 240V ac @ 2.0A resistive Resistive 2A @ 5 30V dc 0.5A @ 48V dc 0.25A @ 125V dc 2A @ 125V ac 2A @ 240V ac Inductive 2.0A steady state @ 5 30V dc, L/R = 7ms 0.5A steady state @ 48V dc, L/R = 7ms 0.25A steady state @ 125V dc, L/R = 7ms 2.0A steady state, 15A make @ 125V ac, PF = cos = 0.4 2.0A steady state, 15A make @ 240V ac, PF = cos = 0.4 250W maximum for 125V ac resistive output 480W maximum for 240V ac resistive output 60W maximum for 30V dc resistive output 24W maximum for 48V dc resistive output 31W maximum for 125V dc resistive output 250VA maximum for 125V ac inductive output 480VA maximum for 240V ac inductive output 60VA maximum for 30V dc inductive output 24VA maximum for 48V dc inductive output 31VA maximum for 125V dc inductive output 8ms maximum (time from a valid output on signal to relay energization by the module) 26ms maximum (time from a valid output off signal to relay deenergization by the module)

10 FLEX I/O 8 Output Relay Module 1794-OW8 Output Specifications Initial Contact Resistance Switching Frequency Operate/Release Time Bounce Time Minimum Contact Load Off State Leakage Current (maximum at 240V ac) Expected Life of Electrical Contacts Flexbus Current Power Dissipation Thermal Dissipation Keyswitch Position 9 Isolation Voltage Between any 2 sets of contacts Customer load to logic Customer load to 24V dc supply Customer 24V dc supply to logic Fuse recommendations Specifications continued on next page 30mΩ 1 operation/3s (0.3Hz at rated load) maximum 10ms maximum 1.2ms (mean) 100µA at 100mV dc 1mA thru snubber circuit 100,000 operations minimum @ rated loads 69mA maximum 5.5W maximum 18.8 BTU/hr maximum 2550V dc for 1 second 2550V dc for 1 second 2550V dc for 1 second 850V dc for 1 second Fusing of outputs is recommended. Use 3.0A, 250V ac slow-blow fuses. Littelfuse pt. no. 239003

FLEX I/O 8 Output Relay Module 11 1794-OW8 Output Specifications General Specifications External dc Power Supply Voltage Voltage Range Supply Current Dimensions Inches (Millimeters) Environmental Conditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Non-operating Vibration Conductors Wire Size Category Agency Certification (when product or packaging is marked) 24V dc nominal 19.2 to 31.2V dc (includes 5% ac ripple) 125mA maximum 1.8H x 3.7W x 2.1D (45.7 x 94.0 x 53.3) 0 to 55 o C (32 to 131 o F) 40 to 85 o C ( 40 to 185 o F) 5 to 95% noncondensing 12 g peak acceleration, 11(+1)ms pulse width 50 g peak acceleration, 11(+1)ms pulse width Tested 2 g @ 10 500Hz per IEC 68-2-6 12 gauge (4mm 2 ) stranded maximum 3/64 inch (1.2mm) insulation maximum 1 1 CSA certified CSA Class I, Division 2 Groups A, B, C, D certified UL listed CE marked for all applicable directives 1 You use this conductor category information for planning conductor routing as described in publication 1770-4.1, Industrial Automation Wiring and Grounding Guidelines.

12 FLEX I/O 8 Output Relay Module With major offices worldwide. World Headquarters, Allen-Bradley, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 Supersedes publication 1794-5.19 December 1995 Publication August 1998 PN955132 29 Copyright 1998 Allen-Bradley Company, Inc. Printed in USA