EN SV SK6. Security Unit. Installation manual. Siemens AB. Security Products



Relevanta dokument
Installation Instructions

Beijer Electronics AB 2000, MA00336A,

Monteringsanvisning Nödutrymningsbeslag ASSA 179E

Windlass Control Panel v1.0.1

INSTALLATION INSTRUCTIONS

Vanliga frågor om Duocom (för installatör eller reparatör) GB Frequently asked questions about Duocom (for installer or repairman)

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

IRAB Mottagare sida 2-5 Tele Radio AB Mottagare sida 6

2.1 Installation of driver using Internet Installation of driver from disk... 3

SkillGuide. Bruksanvisning. Svenska

Får endast utföras av behörig personal. May only be carried out by authorized electrician

Instruction Manual. Svenska, English. Power Bank. Model: PRBN

FORTA M315. Installation. 218 mm.

Support Manual HoistLocatel Electronic Locks

Boiler with heatpump / Värmepumpsberedare

CanCom Bluetooth BLUETOOTH V5.6. Specifikation Specification LED. transceiver

SVENSK STANDARD SS-ISO :2010/Amd 1:2010

Användarhandbok. MHL to HDMI Adapter IM750

Ersättning styrkort GOLD, stl 1-3, Version 1-3/ Replacement control circuit board GOLD, sizes 1-3, Version 1-3

Lösenordsportalen Hosted by UNIT4 For instructions in English, see further down in this document

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

InstalationGuide. English. MODEL:150NHighGain/30NMiniUSBAdapter

Remote control Fjärrströmbrytare / Fjernstrømbryter

Product configurations Produire configuration Produkt konfigurationen Producto configuraciones Produkt konfigurationerna

PORTSECURITY IN SÖLVESBORG

Discovery FSQ, IAA Utgåva/Edition 11. SE Habo. Klass 2 IAA FSQ-I 26W. 4 mm c c mm N L

Isolda Purchase - EDI

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) 1 (12)

81152 TRANSFER CASE SHIFT HANDLE

säkerhetsutrustning / SAFETY EQUIPMENT

Fig. 2: Inkoppling av lindningarna / Winding wiring diagram

1. Unpack content of zip-file to temporary folder and double click Setup

GOLD SD Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1. Fläkt 2/ Fan 2. Med filter/ With filter Filter

Codelock K44 Duo. Installation & User Manual. Siemens AB

Accepterad monteringsanvisning 2016:1. Metris (RSK: ) Metris S (RSK: ) Metris (RSK: )

Monteringsanvisning Nödutrymningsbeslag ASSA 179E-2

Alias 1.0 Rollbaserad inloggning

Installation Instructions

GSH- / GSLS- (CO2) GB Instructions. SE Instruktioner. IS GSH_GSLS CO (Sve Eng).doc 1

Quick Start Guide Snabbguide

Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

Installation Instructions

Beröringsfri EM-läsare VDS

RADIATION TEST REPORT. GAMMA: 30.45k, 59.05k, 118.8k/TM1019 Condition D

Schenker Privpak AB Telefon VAT Nr. SE Schenker ABs ansvarsbestämmelser, identiska med Box 905 Faxnr Säte: Borås

INDUKTIV SLINGDETEKTOR INDUCTIVE LOOP DETECTOR


ARC 32. Tvättställsblandare/Basin Mixer. inr.se

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK

Materialplanering och styrning på grundnivå. 7,5 högskolepoäng

STANDARD. UTM Ingegerd Annergren UTMS Lina Orbéus. UTMD Anders Johansson UTMS Jan Sandberg

Styrteknik: Binära tal, talsystem och koder D3:1

Quick Start. English Svenska. Moca

EN SV. Mifare Reader MF1040 & MF1050. HW version 1.6 or later. Installation Note. Siemens AG


Viktig information för transmittrar med option /A1 Gold-Plated Diaphragm

Installationsguide och beskrivning av Gewa Amplifier. Installation guide and description of Gewa Amplifier

Anvisning för Guide for

Accepterad monteringsanvisning 2016:1

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S 100 CoolStart (RSK: )

SVENSK STANDARD SS-EN ISO :2009/AC:2010

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S (RSK: ) 1 (12)

AXCALL. ADI-611/616/608 Ver 1.7

SPCE120 Indikeringsenhet Användarguide

This manual should be saved! EcoFlush Manual

NX WSI-box. Installation och användarmanual Svenska

Produktens väg från idé till grav

RB500 EM. Card reader RB500 Installation Guide. Siemens AG

CanCom 8 DIGITAL I/O DIGITAL V3.70. Specifikation Specification. Utgångar Output EMC EMC 2004/108/EC

Användarhandbok. USB Charging Dock DK52

Accepterad monteringsanvisning 2016:1. Ecos M CoolStart (RSK: ) Ecos L CoolStart (RSK: ) 1 (12)

ROGER GPS Case 2 repeaters and 1 antenna GPSR-BP, -1 and -S

Z-LYFTEN PRODUKTION AB MONTERINGSANVISNING INSTALLATION INSTRUCTIONS

Manual Uppdaterad UDR-plus. Axema Access Control AB Box Stockholm, Sweden

Quick Start. English Svenska PRIMACY. Printing settings and winsign

BRUKSANVISNING. Oscilla 910

Dokumentnamn Order and safety regulations for Hässleholms Kretsloppscenter. Godkänd/ansvarig Gunilla Holmberg. Kretsloppscenter

SVENSK STANDARD SS-EN 13612/AC:2016

BBT057/ BBC057 BBCD057/ BBT057-NL HOLDEN COLORADO 9/2016+ HOLDEN TRAILBLAZER WD & 4WD Models

ANVÄNDAR. RPSbox1 Manual SE rev2. YTTRE FASÖVERVAKNINGSENHET RPS-BOX 1 FÖR PL5000 och DL8000 DIGITAL

P650 - Takscreen. Installationsguide EN

CCTV eller dispens? Vad göra åt kravet på övervakning av området utanför cockpit från båda pilotstolarna?

Utfärdad av Compiled by Tjst Dept. Telefon Telephone Datum Date Utg nr Edition No. Dokumentnummer Document No.

VASSVIK FIXED STAND SE / ENG

Användarhandbok. Xperia P TV Dock DK21

Elektra C GB NO

Blandningstunna. Bruksanvisning - maskin, LVD och EMC-direktiven s. 1 av / 190 L BRUKSANVISNING. Säkerhet Montering Underhåll och felsökning

Öppnaknapp Scoria Touch

SoundPod. Bärbar Bluetooth ljudförstärkare för små enheter

Kamrör / Ribbed pipe radiator

Styrteknik : Programmering med IEC Styrteknik

To Contact Us. c Copyright , NITGEN Co., Ltd. All rights reserved

Företagsnamn: Grundfos Skapad av: Magnus Johansson Tel: +46(0) Datum:

Bruksanvisning för IR-mottagare GL-4M WM Instructions for Use: IR Receiver GL-4M WM

GOLD SD Med styrenhet/with control unit. Fläkt 1A/B/ Fan 1A/B. Fläkt 2A/B/ Fan 2A/B. Fläkt/ Fan. Utan filter/ Without filter

Metodprov för kontroll av svetsmutterförband Kontrollbestämmelse Method test for inspection of joints of weld nut Inspection specification

SMS-larm L Ver Gjutarevägen Stenkullen

Users manual Bruksanvisning Gebrauchanweisung Guide d instructions

Nathi Skötbord Changing unit Table à langer murale Wickeltisch Verschoontafel Puslebord Cambiador de pared Přebalovací pult Fasciatoio

Quick Start Guide. To switch the TV on. cable to connect the two units together. To select the TV broadcasts. To HDMI connection on.

Transkript:

EN SV SK6 Security Unit Installation manual Security Products

ENGLISH SK6 Installation manual Description The security unit SK6 is used in high security areas. It prevents unauthorised persons from opening the door by short-circuit the conductors to the electric release. It also protects for any manipulating the relay. The SK6 is tested against tamper attempt and relay manipulation for K44Duo, BM3/BM31, TP5/M65 and BC615 which are equipped with a tamper switch for external connection. Optionally it is possible to extend the relay manipulation protection by installing a reed-switch*). Note that the K42 does not need a reed-switch as the protection is built-in to the unit. It is recommended to wait at least 15 seconds after all wiring and power up before testing the units. *) See items 11 and 16 in illustration. Tamper control The security unit SK6 includes a relay that breaks the connection between the lock relay and the electric release when the protected unit s housing is opened. This forms a split-mount solution. Note! This applies only for products with a tamper switch. Alarm output. If the cover of the protected unit is opened, the SK6 can also output a signal to an external alarm control system. The buzzer also starts to sound. Relay manipulation If the door unit does not include the metal parts to protect the lock relay from manipulation, SK6 offers the reed-switch option. K44Duo, BM3/BM31, TP5/M65 and BC615 These units can optionally be installed with a reedswitch to sense any magnetic field manipulation of the lock relay. K42 Via the built-in protection SK6 can determine if the activation of the lock relay is valid or not. Output signal Relay manipulation output. If the lock relay in the protected unit is manipulated (trying to unlock the door) there is a separate output signal. Reset to normal There are two ways to reset the SK6 to normal function: Manual reset. The tamper alarm output is activated until a manual press on the button on the SK6 (see label on unit). The buzzer is also turned off. External signal. A signal from an external system may be connected to perform a reset. Note that if the protected unit is still in the wrong status when the reset occurs, there will be a new alarm generated (and buzzer sounds again). Safety General safety precautions Read the general safety precautions before operating the device. Follow all warnings and instructions marked on the device. Keep this document for reference. Always pass this document on together with the product. The device has been approved for use in the European Union. In countries outside the EU, the local conditions and regulations need to be checked before putting the device into service. Please also take into account any additional country-specific, local safety standards or regulations concerning project planning, operation and disposal of the product. The device should only be mounted indoors. Target group Installer with expert knowledge of building installation technique or electronic installations. Standards and guidelines This product complies with the requirements of the European Directives. The European declaration of conformity is available from:, Security Products Englundavägen 7 SE-171 24 Solna, Sweden European Directive 2004/108/EC on Electromagnetic Compatibility (EMC): Compliance with the European Directive 2004/108//EC has been proven by testing according to the following standards: Technical data Supply voltage (nom.*): Absolute voltage ratings**: Current consumption: Temperature range: Dimensions (H x W x D): 12 24 V AC/DC. 10 35 VDC or 8 24 VAC. Stand by power 12V DC: 20 ma 24V DC: 25 ma Full on 12V DC: 50 ma 24V DC: 85 ma 0 to +50 C 120 x 80 x 40 mm. * Nominal voltage has margins for transformer tolerances, mains supply variations and interruptions. ** Absolute voltage has no margins and should be used for guidance only. Details of ordering Type Item Number Description SK6 S54513-F55-A1 Security Unit Immunity EN61000-6-3 Emission EN 50130-4 2

ENGLISH SK6 Installation manual Installing The SK6 is installed in the door environment and connected as below. 1. The actual product to be protected. Note! For terminal numbers on connection board, see technical information for each product. 2. The power supply is connected to SK6 which feeds the protected unit. It is essential that the power is fed through the SK6 to achieve the protection. Note! Only one protected unit can be connected. If K44Duo controls two doors also two SK6 must be used. The reed-switch (parallel) and the tamper (serial) have to be connected to both SK6. 3. Control signal from door opening relay in protected unit (shown at rest). 4. Tamper switch in protected unit. (Breaks when housing is opened). Jumper J7 in SK6 controls the logic of the signal to SK6. Set to either Normally open or Normally closed function. Default NC. 5. Potential-free lock relay output for connecting to lock. 6. Alarm output. Connects to alarm system or the like. Changes at tamper attempt. 7. Relay manipulation alarm output. Connects to alarm system or the like. Changes at manipulating of the relay in any way. See also item 11. 8. External closing signal input for reset of alarm. 9. SW1 is used for a manual reset of the alarm. See label on the housing. Note that if the protected unit is still in the wrong status a press on this button will reset but a new alarm will occur. 10. Jumper J10. Enable or disable of the internal relay manipulation monitoring. Default Disable. 11. Additional, external closing signal input for monitoring other manipulation of a protected unit. E g via a reed-switch or similar capable of generating a signal. Default Normally open. Jumper J8 in SK6 controls the logic of the input. Set to either Normally open or Normally closed function. Default NO. 12. Red LED when Lock relay active. 13. Red LED when CPU is running. 14. Green LED when Power is on. 15. Buzzer. 16. A reed-switch mounted to sense magnetic fields. See also item 11. Manipulating will close contact. Mounting of reed-switch In case of optionally using the supplied reedswitch kit, please consider how to mount it. The position of the reed-switch is dependant of the products. See the illustrations. In some cases the distance must be used. Note! Do NOT try to press the connector of the reed-switch with a tool. If there also is a magnetic shield protection kit to be used in conjunction with the reed-switch please be cautious how to mount the reedswitch. 3

SVENSKA SK6 Installationshandbok Beskrivning Säkerhetskoppling SK6 används då man har extra höga säkerhetskrav. Den förhindrar för obehöriga att kunna öppna dörren genom att kortsluta ledningarna till ellås. Den skyddar för någon manipulering av reläet. SK6 är testad för sabotageförsök och relämanipulering av K44Duo, BM3/BM31, TP5 /M65 och BC615 som är bestyckade med sabotagekontakt för extern anslutning. Valfritt är det möjligt att utöka skyddet för relämanipulering genom att installera ett reed-relä*). Notera att K42 inte behöver ett reed-relä eftersom skyddet är inbyggt i enheten. Det är rekommenderat att vänta åtminstone 15 sekunder efter anslutning och strömförslag innan enheten testas. *) Se punkt 11 och 16 i illustrationen. Sabotagekontakt Säkerhetsenheten SK6 innehåller ett relä som bryter anslutningen mellan låsreläet och ellåset när den skyddade enhetens kapsling öppnas. Detta skapar ett "delat montage" lösning. Obs! Detta gäller endast produkter med en sabotagekontakt. Larmutgång. Om kapslingen på den skyddade enheten öppnas, kan SK6 också ge en signal till ett externt larmsystem. Summern börjar också ljuda. Relämanipulering Om dörrenheten inte inkluderar några metalldelar för att skydda låsreläet från manipulering, erbjuder SK6 reed-relä optionen. K44Duo, BM3/BM31, TP5/M65 and BC615 Dessa enheter kan valfritt installeras med ett reedrelä för att känna av magnetisk manipulering av låsreläet. K42 Via den inbyggda skyddet kan SK6 avgöra om aktiveringen av låsreläet är giltig eller inte. Utgångssignal Relämanipulering utgång. Om låsreläet i den skyddade enheten manipuleras (försök att låsa upp dörren) ges en separat utsignal. Återställa till normal Det finns två sätt att nollställa SK6 till normal funktion: Manuell återställning. Sabotagelarmutgången är aktiverad tills ett manuellt tryck på knappen på SK6 (se etikett på enheten). Summern stängs också av. Extern signal. En signal från ett extern system kan anslutas för att utföra en nollställning. Notera att om den skyddade enheten fortfarande är i fel status när nollställning sker, så genereras ett nytt larm (och summern ljuder igen). Säkerhet Generella säkerhetsföreskrifter Läs de generella säkerhetsföreskrifterna innan enheten används. Följ alla varningar och instruktioner som är märkta på enheten. Behåll detta dokument som referens. Bifoga alltid detta dokument med produkten. Enheten har godkänts för användning inom EU. I länder utanför EU måste lokala villkor och regler kontrolleras innan enheten tas i bruk. Ta med i beräkningen ytterligare landspecifika, lokala säkerhetsstandarder eller bestämmelser som gäller projektplanering, användning och kassering av produkten. Enheten bör endast monteras inomhus. Målgrupp Installatör med expertkunskap om bygginstallation och elektroniska installationer. Standarder och riktlinjer Produkten uppfyller kraven i EU-direktiven. EUdeklarationen om överensstämmelse kan erhållas från:, Security Products Englundavägen 7 SE-171 24 Solna, Sweden EU-direktiv 2004/108/EC om elektromagnetisk kompatibilitet (EMC): Överensstämmelse med EU-direktiv 2004/108/EC råder genom att standarderna nedan uppfylls: Immunitet EN61000-6-3 Emission EN 50130-4 Tekniska data Matningsspänning (nom. *): Absoluta spänningsgränser **: Strömförbrukning: Temperaturområde: Mått (H x B X D): 12 24 V AC/DC. 10 35 VDC eller 8 24 VAC. Viloström 12V DC: 20 ma 24V DC: 25 ma Full last 12V DC: 50 ma 24V DC: 85 ma 0 till +50 C 120 x 80 x 40 mm. * Nominell spänning har marginaler för transformatortoleranser, nätspänningsvariationer och avbrott. ** Absoluta spänningsgränser har inga marginaler och bör användas endast för vägledning. Orderdetaljer Typ Artikel nr Beskrivning SK6 S54513-F55-A1 Säkerhetskoppling 4

SVENSKA SK6 Installationshandbok Installation SK6 installeras i dörrmiljön och ansluts enligt nedan. 1. Aktuell produkt som skall skyddas. Obs! För plint nummer på anslutningskort, se teknisk information för respektive produkt. 2. Strömkällan ansluts till SK6 som sedan matar den skyddade enheten. Det är nödvändigt att strömmatningen sker "genom" SK6 för att uppnå skyddet. Obs! Endast en skyddad enhet kan anslutas. Om K44Duo styr två dörrar måste två SK6 användas. Reed-reläet (parallellt) och sabotagekontakt (seriellt) måste anslutas till båda SK6. 3. Styrsignal från öppningsrelä i skyddad enhet (ritad i vila). 4. Sabotagekontakt i skyddad enhet. Bruten när kapslingen är öppen Bygel J7 i SK6 styr logiken av signalen till SK6. Sätts till Normalt öppen eller Normalt sluten funktion. Fabriksinställd NC. 5. Potentialfritt låsreläutgång för anslutning till lås. 6. Larmutgång. Kopplas till inbrottslarm e.d. Växlar då sabotagekontakten aktiveras. 7. Larmutgång för relämanipulering Kopplas till inbrottslarm e.d. Ändras vid manipulering av relä på något sätt. Se även punkt 11. 8. Extern slutande signal för nollställning av larm. 9. SW1 används för manuell nollställning av larm. Se etikett på kapslingen. Notera att om den skyddade fortfarande är i felaktigt läge kommer tryck på knappen att återställa - men ett nytt larm sker. 10. Bygel J10. In- och urkoppling av den interna relämanipuleringsövervakningen. Fabriksinställd Disable.. 11. Ytterligare, extern slutande signal för övervakning av annan manipulering av skyddad enhet. T ex via en reed-switch eller liknande som kan generera en signal. Fabriksinställd Normalt sluten. Bygel J8 i SK6 styr logiken för ingången. Sätts till Normalt öppen eller Normalt sluten funktion. Fabriksinställd NO. 12. Röd lysdiod när låsreläet är aktivt. 13. Röd lysdiod när CPU är igång. 14. Grön lysdiod när spänningen är på. 15. Summer. 16. Ett monterat reed-relä för att känna av magnetiska fält. Se även punkt 11. Manipulering aktiverar kontakten. Montering av reed-relä Ifall optionen att änvända meddlevererad reedrelä kit, ta hänsyn till hur det monteras. Positionen av reed-reläet beror på produkterna. See illustrationerna. I några fall måste distansen användas. Obs! Försök INTE att pressa reed-reläets kontakt med ett verktyg. Om det även finns ett magnetfältskydd, som ska användas tillsammans med reed-reläet var varsam med hur reed-reläet monteras. 5

Issued by Security Products International Headquarters Englundavägen 7 SE-171 24 Solna Tel. +46 8 629 0300 www.siemens.com/securityproducts Document no. A6V10333742 Edition 03.2012 2012 Copyright by Data and design subject to change without notice. Supply subject to availability.