ABB Argus Collecting Computer Produktkatalog

Relevanta dokument
CanCom Bluetooth BLUETOOTH V5.6. Specifikation Specification LED. transceiver

Installation Instructions

PFC and EMI filtering

Beacon BluFi Bluzone. Givarna har mycket hög känslighet och kan mäta mycket små förändringar.

FIX LED-LYSRÖRSARMATUR MED AKRYLKÅPA IP44

Ackrediteringens omfattning

AC/DC current clamps (1/2) E N serien. E N series

FIX LED-LYSRÖRSARMATUR MED AKRYLKÅPA IP44

Absolutgivare för marina miljöer

CanCom Multimodul 30

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

ERS (Electrical Road System) Slide-in project within FFI program

Argus mätsystem för felsökning och kontroll

GOLD SD Fläkt 2/ Fan 2. Fläkt 1/ Fan 1. Fläkt/ Fan. Utan filter/ Without filter. Fläkt 1/ Fan 1. Fläkt 2/ Fan 2. Med filter/ With filter Filter

Industrial valves 4 5

Strömtänger för AC. DN serien 5.00 (1/2) DN series

GOLD SD Med styrenhet/with control unit. Fläkt 1A/B/ Fan 1A/B. Fläkt 2A/B/ Fan 2A/B. Fläkt/ Fan. Utan filter/ Without filter

MCP-16RC, Air Purification

802.11b Wireless router w. 4 port switch. StarTech ID: BR411BWDC

Installation Instructions

Beijer Electronics AB 2000, MA00336A,

UTFÖRSÄLJNING KEY DIGITAL 4-1 HDTV Component Video 4-1, RS-232 (KD-CSW4X1)

RUS 08 & 16 INSTRUKTION Tekniska data

Tentamen i Krets- och mätteknik, fk - ETEF15

Examples on Analog Transmission

INSTALLATIONSANVISNING INSTALLATION MANUAL MM-61 ST

Trefasmätningar. Ellära 2 Laboration 4. Laboration Elkraft UMEÅ UNIVERSITET Tillämpad fysik och elektronik Dan Weinehall.

säkerhetsutrustning / SAFETY EQUIPMENT

Product configurations Produire configuration Produkt konfigurationen Producto configuraciones Produkt konfigurationerna

CanCom 8 DIGITAL I/O DIGITAL V3.70. Specifikation Specification. Utgångar Output EMC EMC 2004/108/EC

Modular Cold Rooms Price List

Rev No. Magnetic gripper 3

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MD-62 AC MD-62 DC

Installation Instructions

GOLD SD eff.var./cap.var.120-1

Bruksanvisning. Multimeter KEWTECH KT115

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter

Företagsnamn: Grundfos Skapad av: Magnus Johansson Tel: +46(0) Datum:

Windon LS 1H / LS 1.5H / LS 2H / LS 3H

Våg för flaskpaket - 5

IM10. Installation Note ENGLISH. Before you start the installation, make sure that the following material is available:

General specifications

GOLD SD 100, eff.var./cap.var. 1

GOLD SD 04/05, 07/08, 11 eff.var./cap.var. 1

CanCom Multimodul 30

IRAB Mottagare sida 2-5 Tele Radio AB Mottagare sida 6

Ersättning styrkort GOLD, stl 1-3, Version 1-3/ Replacement control circuit board GOLD, sizes 1-3, Version 1-3

Dokument Rubrik Utgåva Datum. TBE/KBE-DOK TBE/KBE Dokumentförteckning TBE/KBE-REV TBE/KBE Revisionsförteckning 12.

STARTRELÄ PRODUKTINFORMATION

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

PCD1.G5020-A20. E-Line RIO 8DI, 4Rel, 16AI, 4AO. Funktioner. Mått och installation. Allmänna tekniska data

22/02/16. Arduino Introduktion till Arduino. Arduino. Microcontroller - Embedded systems. Historia Organisation - Ekosystem

DSAB Spettrobot Modell SPRAYROD

F-ARI. Nya självtestande jordfelsbrytare med automatiska testfunktioner

nwind and nwind-race transducer Twin Fin Installation Manual English Installationsmanual Svensk

GOLD SD 100, eff.var./cap.var. 2

Viktig information för transmittrar med option /A1 Gold-Plated Diaphragm

Registreringssystem för oljor. Oil Management System

Z-LYFTEN PRODUKTION AB MONTERINGSANVISNING INSTALLATION INSTRUCTIONS

Monitor Audio ASB 2. Soundbar. Monitor Audios Nya soundbar är här! Den ultimata högtalaren för din tv. Monitor Audios soundbar är här!

SOLAR LIGHT SOLUTION. Giving you the advantages of sunshine. Ningbo Green Light Energy Technology Co., Ltd.

Kom igång med DSO-X 2014A

1 st givare med 2 meter kabel, ansluten till signalmottagare som i sin tur är ansluten till en EX-barrier med 5 meter kabel.

CanCom. Multimodul C700 V7. Specifikation. Inputs. Digital/Analog

Elektromagnetiska flödesmätare. Modell AMC2100

BESLUT. Beslut om försäljningsförbud och betalningsskyldighet

Instruktioner för antennförstärkare ELKO Link Home R/TV Modul

Färgbevakningskamera. Innehåll. Svenska. Sida

Datasäkerhet och integritet

MT-30C, MT-29, MT-29C

INVERTER MULTIPROCESS MIG/MAG-TIG-MMA

ZB5AV033S ( ) Lampkalott plast grön för Led räfflad lins

Windlass Control Panel v1.0.1

SE/GB.ELSD5060E

DAMPER EQAZ-12, EQAZ-13, STAZ-30, STBZ-30

Discovery FSQ, IAA Utgåva/Edition 11. SE Habo. Klass 2 IAA FSQ-I 26W. 4 mm c c mm N L

Ringmaster RM3 - RM 5 RM3 RM 4 RM 5

UTFÖRSÄLJNING 2012 PANASONIC DVD-SPELARE SVART (DVD-S511) DEMO EX. PANASONIC DVD/VHS RECORDER (DMR-ES35V) DEMO EX.

INDUKTIV SLINGDETEKTOR INDUCTIVE LOOP DETECTOR

PCD1.G5010-A20. E-Line RIO 12 DI, 4 Relä, 12 AI, 8 AU. Funktioner. Allmänna tekniska data. Mått och installation

För att justera TX finns det ett tool med namnet MMDVMCal. t.ex. /home/pi/applications/mmdvmcal/mmdvmcal /dev/ttyacm0

Elhah-listbelysning. Made in Finland. Vi förbehåller oss rätten till produktändringar.

Isolda Purchase - EDI

Teknisk support finns tillgänglig Måndag-Fredag 08:00-16:30. Övrig dokumentation finns tillgänglig på Teletecs hemsida -

GOLD SD 100, eff.var./cap.var. 2

Cable, highly flexible Metal plug Integrated amplifier Short-circuit protection Starting pulse suppression LED / ring- LED.

TN LR TT mg/l N b) 2,6-Dimethylphenole

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

OMRON. PLC till PLC kommunikation (CP1L-E) Ethernet. 22 april 2014 OMRON Corporation

EU gemensamma regler för drönare. Rémi Vesvre

LED-vägglist. Made in Finland. Vi förbehåller oss rätten till produktändringar.

Digital Personvåg MANUAL H

CanCom 4 A/D, 2+2 PWM

Monteringsanvisning Nödutrymningsbeslag ASSA 179E

SE/GB.ELSD5060E

CanCom. MULTIMODUL A/D V4.0b. Specifikation Specification

CanCom. DJ803 Prod.ver Specifikation Specification

Multipol, AS-Interface, Profi- eller Interbus 4 24 ventil platser, R1/8 och R1/4, Nl/min Tekniska data för serie RE-19

GOLD SD/CX 120, eff.var./cap.var. 2

Transkript:

ABB Argus Collecting Computer Produktkatalog Innehållsförteckning CC/4P-32/64 CC/4C CC/4B Portabel basenhet 32/64AI + DAU kommunikation Stationär basenhet i HF tätt väggskåp Portabel basenhet 16 differentiella AI + DAU kommunikation CC335-B Aktiv pod, 8 differentiella AI ( 5 isolerade, 3 BNC för strömtång ) CC376 CC377 CC378 CC379 CC380 CC381 CC382 CC383 CC384 CC385 Högspänningspod Cat III, 3 kanaler Högspänningspod för fast installation, 1 kanal Mätuttag för fast installation Cat III 1 kv, 1 kanal Mätprobe Cat III, 1 kanal Busslyssnare AF100 Distribuerad ingångsenhet, 8AI Distribuerad ingångsenhet, 4 AI + 1 PG Busslyssnare Profibus Distribuerad ingångsenhet, 4 PG Busslyssnare: ABB DDCS, Drive Bus, Module Bus Prislista

ABB Argus CC/4P Portable unit Analog channels Number of internal channels: Measuring range: Resolution: Sampling speed: Input impedance: Anti-aliasing filter : Measurement memory size: Communication with PC 64 (CC/4P-64) or 32 (CC/4P-32) Determined by external adapters such as CC335B, CC379 ±1V to ±1kV 12 bit 5 µs per channel 1 M 47 pf Automatically set depending on sampling time in HW and SW. Limited only by the PC hard drive. Ex. 240GB stores six channels with 30us sampling time one week. Standard Ethernet 10-100Mbit full duplex Communication with distributed units DAU Speed: 10 Mbit or 2 Mbit. Number of optical links : 2 Maximum length of fiber : Plastic (POF) 20m, glass (HCS) 500m Supply Dimensions Weight 110 240 V AC / 40 W Analog inputs isolated from enclosure and power. Height 260 / Length 340 / Width 120 (mm). 5.5 kg

ABB Argus CC/4C Central unit for permanent installation Capacity Memory size: Limited only by the PC hard drive ex. 300GB Max parallel measurements: Limited only by PC performance ex. 10-40 Parallel hardware for fast measurement. Continuous measuring of up to 100 channels with 500usec sampling time. Channels in distributed units DAU Maximum number in HW : 4096 ( No internal channels in CC/4C ). Maximum number of TCP/IP (VIP) channels limited only by PC performance ex. 10-2000. Anti-aliasing filter : Automatically set depending on sampling time in HW and SW. Communication with PC Standard Ethernet 10-100Mbit full duplex Communication with distributed units DAU Speed: 10 Mbit or 2 Mbit. Number of optical links : 2 Maximum length of fiber : Plastic (POF) 20m, glass (HCS) 500m Power Dimensions (mm) Mounting 110 240 V AC / 15W Height 400 / Width 300 / Depth 130 (mm). Enclosure for wall mounting. Complies with EC directive for CE certificate of conformity

ABB Argus CC/4B Portable unit Analog channels Number of internal channels: 16 Measuring range: ±1V till ±1,5kV DC / 1kV AC CATIII Resolution: 12 bit Sampling speed: 5 µs per channel Input impedance: 1 M 47 pf Anti-aliasing filter : Automatically set depending on sampling time in HW and SW. Measurement memory size: Communication with PC Limited only by the PC hard drive. Ex. 240GB stores six channels with 30us sampling time one week. Standard Ethernet 10-100Mbit full duplex Communication with distributed units DAU Speed: 10 Mbit or 2 Mbit. Number of optical links : 2 Maximum length of fiber : Plastic (POF) 20m, glass (HCS) 500m Supply Dimensions Weight 110 240 V AC / 30 W Analog inputs isolated from enclosure and power. Height 174 / Length 406 / Width 330 (mm). 7 kg

ABB Argus CC335B Differential input adapter Analog channels Number of channels: 8 Anti-aliasing filter: 16 khz All inputs are fully differential and separated from Argus signal ground. Differential inputs for measurement without ground loops Channel: 1-8 Measuring range: ± 1 V to ±30 V CAT II 50V Overall accuracy: ± 1% Common mode range: ±200V Common mode rejection: 60dB Input impedance: 800 k 47 pf Current inputs for process signals 4-20mA Channel: 1-8 Measuring range : ± 25 ma CAT II 50V Common mode range: ±200V Isolated inputs for instrument transformers etc. Channel: 1-5 Measuring range: ± 420 V Reinforced insulation CAT IV 150 V CAT III 300V Overall accuracy: ± 2 % BNC inputs for CC379 or clamp-on ammeter. Channel: 6-8 Measuring range: ± 1 V till ±12 V Supply voltage (output) 10 V (max 30 ma) Dimensions (mm) Width 75 / Length 111 / Depth 190 (mm).

ABB Argus CC376 HSP Adapter for CAT III 1kV Three fully separated channels for flexible measurements. Applications Voltage measurement in measurement category 3 up to 1kV. Examples are bus-bars, incoming voltage, intermediate DC voltage, UPS and motors. Electrical data Measuring range: 1000 V RMS or ±1500 V DC Conversion ratio 1500 V / 10 V Overall accuracy (-40 C.. +85 C) Max 0.6% Offset (-40 C.. +85 C) Max 13mV Response time (1.3kV) 0.4 s Frequency bandwidth (-1dB) 330 V RMS DC..800 khz Complies with SS-EN 61 010-1 for 1000 V Overvoltage Category III, Pollution Degree 2 Dimensions Height 150 / Width 220 / 125 Depth (mm)

ABB Argus CC377 HV Adapter for CAT III 1kV The transducer is intended for measurement in industrial environment Cat III. Voltages up to 1 kv RMS AC or ±1.5kV DC can be measured. The optional current transducer has to be selected, depending on its full scale range. Models with range from 50 A up to 1 ka RMS or DC are availabe. When current is measured the voltage is limited to 500V RMS Cat 3. The unit has galvanic isolation between the primary circuit (high voltage) and the secondary circuit (Argus CC). Each unit is calibrated and has been tested for insulation breakdown (at 5 kv). -Excellent accuracy -Very good linearity -Low thermal drift -High bandwidth -High immunity to external interference Applications -Breakers. -Bus bars. -AC variable speed drives. -Converters for DC motor drives. -Uninterruptible Power Supplies (UPS) Electrical data -Primary nominal RMS voltage 1 000 V 0.. 1 500 V -Measuring range, primary voltage -Secondary analog voltage 10 V -Conversion ratio 1 500 V / 10 V Accuracy Current (Model 200 A) -Accuracy (at 200 A) -25 C..+85 C Max 1% -Linearity -25 C..+85 C Max 0.5% -Offset voltage (at 0 A) -25 C..+85 C Max 10 mv -Response time (at 1.3 kv) < 3 s -Frequency bandwidth (-3dB) DC..50 khz Voltage -Overall accuracy (at 1.5 kv) -40 C..+85 C Max 0.6% -Offset voltage (at 0 V) -40 C..+85 C Max 13 mv -Response time (at 1.3 kv) -Frequency bandwidth (-1dB) at 330 V RMS 0.4 s DC..800 khz Complies with SS-EN 61 010-1 for 1000 V Overvoltage Category III, Pollution Degree 2

ABB Argus CC378 Voltage measurement terminal for CAT III 1kV Enabling secure measurements in Cat 3 environment. Applications Voltage measurement in measurement category 3 up to 1kV. Examples are bus-bars, incoming voltage, intermediate DC voltage, UPS and motors. Electrical data Measuring range 1000V RMS or ±1500V DC Conversion range 1:1 Overall accuracy (-40 C.. +85 C) Max 1% Complies with SS-EN 61 010-1 for 1000 V Overvoltage Category III, Pollution Degree 2 Dimensions Height 170 / Width 130 / Depth 90 (mm).

ABB Argus CC379 High voltage probe CAT III 1kV Enabling secure measurements in Cat 3 environment. Applications Voltage measurement in measurement category 3 up to 1kV. Examples are bus-bars, incoming voltage, intermediate DC voltage, UPS and motors. Electrical data Measuring range 1000 V RMS or ±1500 V DC Conversion range 1500 V / 2 V Input impedance 10 M // 10 pf Accuracy (-40 C.. +85 C) Max 1% Bandwith (-3dB) DC to 16 khz Complies with SS-EN 61 010-1 Cat I - IV 600V RMS Double insulation Cat I - III 1000V RMS Double insulation Connections Primary Secondary Power Dimensions Ø 4 mm safety sockets. BNC. 8-20 V AC / DC 30mA Height 40 / Width 156 / Depth 22 (mm).

ABB Argus CC380 ABB AF100 Interface AF100 interface Connection: Data recording: Capacity: Supply Input range: Load: Argus communication Speed: Dimension Mounting Connected to the modem ABB TC630 or ABB TC514 with optical fiber. The bus is galvanically separated from other electronics and power. The CC380 is a passive listener and can not obstruct traffic. CC385 intercepts the signals going to and from drives. No additional programming is required. 32 transmission elements such as AFTRA with each 8 signals can be intercepted. Most data types are supported such as long, real and boolean. 20 35 V DC. 5 W (200 ma at 24 V DC). Power input isolated from chassis ground and other electronics. 2 Mbit/s. Height 130 / Width 65 / Depth 160 (mm). DIN rail 35 mm.

ABB Argus CC381 8 analog input channels Analog input Number of channels: 8 Measuring range: 12,5 V Resolution: 12 bit (6,1 mv) Input impedance: 1 M 47 pf Anti-aliasing filter: Automatically set according to selected sample time. System performance Supply Input range: Load: Communication: Dimensions Mounting 1 data sample each 3 s when using 10 Mbit communication. 20 35 V DC 3 W (125 ma at 24 V DC) Power input isolated from ground and analog common. 10 Mbit /s or 2 Mbit /s, automatically detected. Height 72 / Width 108 / Depth 115 (mm). DIN rail 35 mm.

ABB Argus CC382 4 analog inputs + 1 encoder channel Incremental encoder input Input A, B: Dual phases, for reversible drives. Input B not required for single direction. The input is isolated from the analog channels and power. Max pulse amplitude: 30 V. Threshold and hysteresis: Software configurable from 20 V to +20 V. Resolution: 16 bits in the selected speed range. Input impedance: 60 k. Conversion time: 0,25 ms. Analog inputs Number of channels: 4 Measuring range: 12,5 V Resolution: 12 bit (6,1 mv) Input impedance: 1 M 47 pf Anti-aliasing filter: Automatically set according to selected sample time. Supply Input range: Load: Communication: Dimensions: Mounting: 20 35 V DC 3 W (125 ma at 24 V DC) Power input isolated from ground and analog common. 10 Mbit /s or 2 Mbit /s, automatically detected. Height 72 / Width 108 / Depth 115 (mm). DIN rail 35 mm.

ABB Argus CC383 ProfiBus Interface Profibus DP Interface Type: Profibus-DP Slave functionality according to IEC 61158. Certification: Interface certified by PNO (Profibus User Organization). Connector: 9-pin DSUB, as standard. Node address: 1 99. Set on switches on CC383 front panel. Profibus 9.6 kbit/s 12 MBit/s. Automatically detected. The bus is galvanically isolated from other electronics. Termination: Termination switch on CC383 front panel. Data recording: The CC383 acts as an ordinary slave unit. The master must be configured to send the specific data to the CC383. Capacity: Up to 244 bytes or 122 16bit integers. Supply Input range: Load: Argus communication Speed: System performance: Dimension Mounting 20 35 V DC 5 W (200 ma at 24 V DC) Power input isolated from ground and Profibus common. 10 Mbit or 2 Mbit, automatically detected. 1 data sample each 3 µs when using 10 Mbit communication. Height 72 / Width 108 / Depth 115 (mm). DIN rail 35 mm.

ABB Argus CC384 4 encoder channels Velocity from incremental encoders Incremental encoder inputs Input A, B: Dual phases, for reversible drives. Input B not required for single direction drives Each channel is isolated. Max pulse ampltude: 30 V. Threshold and hysteresis: Configured in software from 1V to 15 V. Resolution: 16 bit in the selected speed range. Input impedance: 140 k // 47 pf. Minimum conversion time: 0,4 ms. Pulse Encoder Error Detection Duty cycle: Calculated on A pulse on each of the 4 channels. Phase displacement: Calculated between A and B pulse on each of the 4 channels. Missing pulse: A check that an A pulse is always followed by a B pulse. Rise time: The slope of A pulse is measured on all 4 input channels Supply Input range: 20 35 V DC Load: 3 W (125 ma at 24 V DC) Communication Speed 10 Mbit or 2 Mbit. Dimensions Height 72 / Width 108 / Depth 115 (mm). Mounting DIN rail 35 mm.

ABB Argus CC385 ABB DDCS Interface ABB DDCS interface Type: ABB DDCS, ABB DriveBus (DDCS+), ABB ModuleBus. Communication media: Optical fiber. POF Ø1mm eller HCS Ø 200 m. Connection: Ring, star or with fibre splitter CC329. Max cable length: 200 m HCS or 15 m POF with CC329. 5 m in ring configuration. Signal capacity: 80 datasets each with 3 16bit integers or booleans. Signals from master or slave. Max 20 nodes. Data recording: CC385 intercepts the signals going to and from drives. No additional programming is required. Supply Input range: 20 35 V DC Load: 4 W (175 ma at 24 V DC) Argus communication Speed: System performance: Dimension Mounting 10 Mbit or 2 Mbit, automatically detected. 1 data sample each 3 µs when using 10 Mbit communication Height 72 / Width 108 / Depth 115 (mm). DIN rail 35 mm.

ABB Argus Collecting Computer Riktprislista 2010-07-01 Basenhet: Collecting Computer CC/4P-32 Portabel Argus 32 AI + DAU-komm 139 000 CC/4P-64 Portabel Argus 64 AI + DAU-komm 161 000 CC/4C Argus (CPU + 4MB mätminne) i HF-tätt väggskåp 120 000 CC/4B Portabel Argus 16 AI Diff + DAU-komm, inkl mjukvara för parallella mätningar. 99 500 Anslutningsenheter för portabel användning CC333 Passiv pod, 16 analoga kanaler med gemensam nollpunkt 2 500 CC334-D Aktiv pod, 16 analoga kanaler varav 4 isolerade 27 600 CC335-B Aktiv pod, 8 analoga differentiella kanaler ( 5 isolerade, 3 BNC för strömtång ) 24 000 CC376 Högspänningspod Cat III 1kV, 3 kanaler 33 700 CC379 Mätprobe Cat III 1kV, 1 kanal 3 200 Anslutningsenheter för fast installation CC320 Anslutningsenhet för 4 differentiella kanaler 3 100 CC322 Anslutningsenhet för 8 differentiella kanaler 6 000 CC365 Anslutningsenhet för 16 kanaler med gemensam nollpunkt 1 200 CC377 Högspänningspod för fast installation, 1kanal 14 900 CC378 Mätuttag Cat III 1kV, 1 kanal 2 000 CC380A Busslyssnare: AF 100 41 000 CC380B Busslyssnare: AF 100 41 000 CC381 Distribuerad ingångsenhet, 8 analoga kanaler 19 400 CC382 Distribuerad ingångsenhet, 4 analoga kanaler, 1 pulsgivaringång 20 000 CC383 Busslyssnare: ProfiBus 22 400 CC384 Distribuerad ingångsenhet, 4 pulsgivaringångar 24 100 CC385 Busslyssnare: ABB DDCS, Drive Bus, Module Bus 24 600 CC355 Matningsdon 100-240 VAC, 24VDC 600 CC356 Anslutningsenhet 8 kanaler AI ( för anslutning mot dist I/O ) 3 200 CC357 Anslutningsenhet 4 kanaler AI, 1 kanal PG ( för anslutning mot dist I/O ) 3 100

ABB Argus Collecting Computer Riktprislista 2010-07-01 Anslutningskablar CCK20-1 Optokabel ( plast ) kontakterad med V-PIN, 1 meter 610 CCK20-2 Optokabel ( plast ) kontakterad med V-PIN, 2 meter 610 CCK20-5 Optokabel ( plast ) kontakterad med V-PIN, 5 meter 610 CCK20-10 Optokabel ( plast ) kontakterad med V-PIN, 10 meter 1 100 CCK20-25 Optokabel ( plast ) kontakterad med V-PIN, 25 meter 1 400 CCK58-30 Optokabel ( glasfiber ) kontakterad med V-PIN, 30 meter 3 700 CCK45 Bandkabelsats för anslutning av 2 st CC365 380 CCK46 Bandkabelsats för anslutning av 2 st CC322 690 CCK50 Optokabel ( 200u fiber ) med ST/ST-kontakt för AF100 modem, ca 2 m 600 Tillbehör CC366 Väska till CC/4P-32 7 000 CC368 Tillbehörskit till CC366 9 600 Tilläggsprogram PM Parallella mätningar 16 000 FM Prioriterade mätkanaler för snabb mätning ( fastlane ) 14 000 ACM Automatisk tillståndskontroll 34 200 VIP Vip protokoll för TCP / IP 13 000 PQA Nätanalys 14 000 Tjänster Uppgradering CC/3P - - - CC/4P-32 Uppgradering CC/3P - - - CC/4P-64 Uppgradering CC/4P - CC/4B Kalibrering Argus basenhet Kalibrering aktiv pod CC334 Kalibrering differentialpod CC335 Kalibrering högspänningspod CC376 90 000 120 000 75 000 2 000 1 550 1 500 800 Vid beställning eller förfrågningar: Kontakta Stefan Birath 021-343336 stefan.birath@se.abb.com,, Box 202, 812 25 Storvik 5FAA001888