Accepterad monteringsanvisning 2016:1. Raindance Showerpipe (RSK: ) 1 (20)

Relevanta dokument
SV Bruksanvisning / Monteringsanvisning. Croma Showerpipe

Ecostat Comfort (RSK: ) Ecostat Comfort (RSK: ) 1 (16)

Ecostat 1001 CL Ecostat 1001 CL (16)

Raindance Showerpipe (RSK: ) 1 (20)

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) 1 (12)

Accepterad monteringsanvisning 2016:1. Metris (RSK: ) Metris S (RSK: ) Metris (RSK: )

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) Talis S² Variarc (RSK: ) Metris (RSK: )

Accepterad monteringsanvisning 2016:1. Ecos M CoolStart (RSK: ) Ecos L CoolStart (RSK: ) 1 (12)

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S 100 CoolStart (RSK: )

Raindance Showerpipe (20)

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) Focus 100 CoolStart (RSK: ) (RSK: )

Accepterad monteringsanvisning 2016:1

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S (RSK: ) 1 (12)

Ecostat 1001 SL (RSK: ) Ecostat 1001 SL (RSK: ) 1 (16)

Croma Showerpipe (20)

Raindance Showerpipe (20)

Accepterad monteringsanvisning 2016:1. Talis E ( ) ( ) Talis E 110 CoolStart ( )

Marin² Showerpipe (20)

MySelect S 240 Showerpipe (20)

Ecostat 1001 SL (RSK: ) Ecostat 1001 SL (RSK: ) 1 (16)

Original 600 SILICONE. 1 x. 3 x. 3 x

Logis (RSK: ) (RSK: ) (RSK: ) Logis 70 CoolStart (RSK: )

Raindance Select Showerpipe

East 600. x 33. x 33 x 7 x 7. x 6. x

BOW. Art.nr

BRIC MODELL A

BATH MIXER 160 LINC 21. incl. HAND SHOWER. inr.se

Nathi Skötbord Changing unit Table à langer murale Wickeltisch Verschoontafel Puslebord Cambiador de pared Přebalovací pult Fasciatoio

(SV) Installationsmanual för duschkabiner och ångbastukabiner (EN) Installation manual for shower cabins and steam cabins

Shower cabins / Steam cabins

(SV) Installationsmanual för duschkabiner och ångbastukabiner (EN) Installation manual for shower cabins and steam cabins

INSTALLATION INSTRUCTIONS

ARC 32. Tvättställsblandare/Basin Mixer. inr.se

Anvisning för Guide for

STRICT Art.nr ,

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENS LÄS IGENOM INSTRUKTIONSMANUALEN

INSTALLATION. (SE) Duschkabin och ångbastu (UK) Shower cabins and steam cabins. Model

LINC MODELL 13. INR SVERIGE AB Kosterögatan 15 SE Malmö 13 EN 1428:2005+A1:2008

LINC 23. Tvättställsblandare/Basin Mixer. inr.se A

P650 - Takscreen. Installationsguide EN

Installation Wall. Art. #

Bathtub Filler CN EN. TBP02201 Type / TBP02202 Type. Installation Manual. Continued on the back cover

LINC Modell A

POSH. Art.nr

Your No. 1 Workout. MANUAL pro

VASSVIK FIXED STAND SE / ENG

Bruksanvisning Directions for use

CASUAL. Art.nr

Raindance Showerpipe

Installation. Twice Nisch. Twice Corner SVENSKA ENGLISH

MCP-16RC, Air Purification

LINC 22 SHOWER MIXER 150 SHOWER MIXER 160. inr.se

Monteringsanvisning Nödutrymningsbeslag ASSA 179E

LINC 23 TVÄTTSTÄLLSBLANDARE

SAFETY PRECAUTIONS SPECIFICATIONS

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

This manual should be saved! EcoFlush Manual

Storlek/ Size. Modell/ Model. Effekt/ Effect. Vattenmängd/ Water amount T30 63W T30 87W T30 67W T30 76W T30 108W T30 121W

Windlass Control Panel v1.0.1

Boiler with heatpump / Värmepumpsberedare

Spotlight Set Spotlightset / Spotlightsett

Installation Instructions

Floor. Garanti/Warranty. Service, resevdelar/spare-parts Sweden: Tel: +46 (0) Norway: Tel: Finland: Puh:

SUZUKI GRAND VITARA 3P CITY 2011»

EPIC MODELL A. INR guarantees product function if the industry regulations and the installation instruction are followed.

STANDARD. UTM Ingegerd Annergren UTMS Lina Orbéus. UTMD Anders Johansson UTMS Jan Sandberg

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK


Molift Raiser 75135G Etac Box 203, Anderstorp Sweden Tel Fax

ASSEMBLY INSTRUCTIONS SCALE CIRCLE - STANDARD

ELENOR. Svensk generalagent H&G / Gesta Gård Strängnäs SWEDEN Tel

FORTA M315. Installation. 218 mm.

LINC 23. Duschblandare/Shower Mixer. inr.se A

VARIOBARRIER S/M MIMSAFE BY CHOICE

Instruction Manual. Svenska, English. Power Bank. Model: PRBN

SAFETY PRECAUTIONS SPECIFICATIONS


Z-LYFTEN PRODUKTION AB MONTERINGSANVISNING INSTALLATION INSTRUCTIONS

ASSEMBLY INSTRUCTIONS SCALE - SYSTEM

Beijer Electronics AB 2000, MA00336A,

ASSEMBLY INSTRUCTIONS SCALE SQUARE - STANDARD

Kamrör / Ribbed pipe radiator

Technical description with installation and maintenance instructions

Dokumentnamn Order and safety regulations for Hässleholms Kretsloppscenter. Godkänd/ansvarig Gunilla Holmberg. Kretsloppscenter

BBT057/ BBC057 BBCD057/ BBT057-NL HOLDEN COLORADO 9/2016+ HOLDEN TRAILBLAZER WD & 4WD Models

BBT042/ BBC042/ BBCD042 NISSAN NAVARA D40 V STX & PATHFINDER R WD & 4WD Models

Metodprov för kontroll av svetsmutterförband Kontrollbestämmelse Method test for inspection of joints of weld nut Inspection specification

Ringmaster RM3 - RM 5 RM3 RM 4 RM 5

This manual should be saved! EcoFlush Manual. Wostman 2018:2

Fiat » Fiat Panda / 4x4 2003» Fiat Panda 4x4 Climbing / 4x4 Cross 20033»

Slangupprullare Hose reels

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENSLÄS IGENOM INSTRUKTIONSMANUALEN NOGGRANT

Joki Joki Air. JCD70-xx JAD90-xx. lasiesta.com. Manual. Betriebsanleitung. Manuel. Manual. Manuale. Gebruiksaanwijzing.

Rev No. Magnetic gripper 3

Svenska()(Bruksanvisning(för(handdukstork()(1400(x(250(mm(

Företagsnamn: Grundfos Skapad av: Magnus Johansson Tel: +46(0) Datum:

CANALKLER 250S. Gänga i tum Thread in inch

DE Gebrauchsanleitung / Montageanleitung 2 SV Bruksanvisning / Monteringsanvisning 4. Ecostat 1001 SL

GOLD SD Med styrenhet/with control unit. Fläkt 1A/B/ Fan 1A/B. Fläkt 2A/B/ Fan 2A/B. Fläkt/ Fan. Utan filter/ Without filter

Digital Personvåg MANUAL H

Transkript:

EN Table of contents 1 Instructions for use / assembly instructions 2 Troubleshooting 3 Assembly 6-10 Adjustment 10 Safety Function 11 Operation 12-13 Test certificate 13 Maintenance 14-15 Cleaning 16-18 Dimensions 19 Flow diagram 19 Spare parts 20 Contact information 20 SV Innehållsförtäckning 1 Bruksanvisning / Monteringsanvisning 4 Felsökning 5 Montering 6-10 Inställning av maxtemperatur 10 Safety Function 11 Hantering 12-13 Testsigill 13 Skötsel 14-15 Rengöring 16-18 Måttskiss 19 Flödesschema 19 Reservdelar 20 Kontaktinformation 20 Accepterad monteringsanvisning 2016:1 Raindance Showerpipe 27233000 (RSK: 8126253) 1 (20)

English Safety Notes Gloves should be worn during installation to prevent crushing and cutting injuries. The arm of the shower head is intended only to hold the shower head. Do not load it down with other objects! Children as well as adults with physical, mental and/ or sensoric impairments must not use this shower system without proper supervision. Persons under the influence of alcohol or drugs are prohibited from using this shower system. Do not allow the streams of the shower touch sensitive body parts (such as your eyes). An adequate distance must be kept between the shower and you. The product may not be used as a holding handle. A separate handle must be installed. The shower system may only be used for bathing, hygienic and body cleaning purposes. The hot and cold supplies must be of equal pressures. Installation Instructions Prior to installation, inspect the product for transport damages. After it has been installed, no transport or surface damage will be honoured. The product is not designed to be used with steam baths! The pipes and the fixture must be installed, flushed and tested as per the applicable standards. The plumbing codes applicable in the respective countries must be oberserved. The installation dimensions stated in these installation instructions are ideal for people of approximately 1800 mm in body height. The dimensions can be altered if required. In this case, pay attention to the fact that a change of installation height will also change the minimum height, and that the altered mounting dimensions must be taken into consideration. Where the contractor mounts the product, he should ensure that the entire area of the wall to which the mounting plate is to be fitted, is flat (no projecting joints or tiles sticking out), that the structure of the wall is suitable for the installation of the product and has no weak points. The filter insert must be use to protect the shower against incoming dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the shower; such caused faults voids all liability and guarantee claims. If required, the bottom part of the pipe between the fixture and the shower head can be shortened with a fine-toothed saw. Assembly (see page 6) Pressure and permeability test The connections of the thermostatic mixer should be tested regular after installation. Technical Data Operating pressure: max. 1 MPa Recommended operating pressure: 0,15-0,5 MPa Test pressure: 1,6 MPa (1 MPa = 10 bar = 147 PSI) Hot water temperature: max. 70 C Recommended hot water temp.: 65 C Centre distance: 160 mm Connections M 26x1,5: cold right - hot left Thermal disinfection: max. 70 C / 4 min Safety against backflow The product is exclusively designed for drinking water! 2 (20)

English Symbol description Do not use silicone containing acetic acid! Operation (see page 12) Cleaning (see page 16) Adjustment (see page 10) After the installation, the output temperature of the fitting must be tested and set to the temperate desired by the customer. Correction is necessary if the temperature measured at the take off point differs from the temperature set on the scale. Safety Function (see page 11) The desired maximum temperature for example max. 42º C can be pre-set thanks to the safety function. Maintenance (see page 14) The check valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year). Dimensions (see page 19) Flow diagram (see page 19) overhead shower Hand shower Spare parts (see page 20) Special accessories (order as an extra) #98681000 tile-matching-disk chrome plated Test certificate (see page 13) To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold. Troubleshooting Fault Cause Remedy Insufficient water - Supply pressure inadequate - Check water pressure (If a pump has been installed check to see if the pump is working). - Filters are dirty (97367000) - Cleaning the filter in the water connection and at the thermostat cartridge (97367000) - Shower filter seal dirty - Clean filter seal between shower and hose Crossflow, hot water being forced - Backflow preventers dirty or leaking - Clean backflow preventers, into cold water pipe, or vice versa, exchange if necessary when mixer is closed Spout temperature does not - Thermostat has not been adjusted - Adjust thermostat correspond with temperature set - Hot water temperature too low - Increase hot water temperature to 42 ºC to 65 ºC Temperature regulation not possible - thermo cartridge calcified - Exchange thermo cartridge Instantaneous heater didn't work with - Filters are dirty - Clean the filter / exchange filter thermostat - check valve hasn't moved back - Exchange check valves Assembly (See Page 6) 3 (20)

Svenska Säkerhetsanvisningar Handskar ska bäras under monteringsarbetet så att man kan undvika kläm- och skärskadorgen werden. Armen som håller huvudduschen är bara konstruerad för detta; den får inte belastas med andra föremål! Barn samt vuxna med fysiska, psykiska eller sensoriska funktionshinder får inte använda duschsystemet ensamma. Personer som är påverkade av alkohol- eller droger får inte använda duschsystemet. Undvik att rikta duschstrålarna mot känsliga kroppsdelar (t. ex. ögonen. Det måste finnas ett tillräckligt stort avstånd mellan duschen och kroppen. Produkten får inte användas som handtag. Ett separat handtag måste monteras. Duschsystemet får bara användas till kroppshygien med bad och dusch. Stora tryckskillnader mellan anslutningarna för varmt och kallt vatten måste utjämnas. Monteringsanvisningar Det måste undersökas om produkten har transportskador innan den monteras. Efter monteringen accepteras inga transport- eller ytskiktskador. Produkten är inte avsedd att användas tillsammans med ett ångbad! Ledningarna och blandaren måste monteras, spolas igenom och kontrolleras enligt de gällande normerna. De installationsriktlinjer som gäller i länderna ska följas. De monteringsmått som anges i monteringsanvisningen passar 1,80 m långa personer och måste eventuellt anpassas. Det är då viktigt att tänka på att den minsta höjden ändras när monteringshöjden blir en annan och att hänsyn måste tas till de ändrade anslutningsmåtten. När kvalificerad fackpersonal monterar produkten är det viktigt att tänka på att monteringsytan är plan i alla delar av arbetsytan (inga fogar som sticker ut eller klinkerförskjutningar), att väggkonstruktionen passar till montering av produkten samt att den inte har svaga punkter. Silpackningen som följer med duschen måste monteras för att undvika att smuts från ledningsnätet tränger in. Smuts som spolas in kan påverka funktionerna och/eller leda till skador på funktionsdelar i duschen. Hansgrohe frånsäger sig allt ansvar för skador som kan härledas till detta. Om det behövs kan röret mellan blandare och huvuddusch kortas i den nedre delen med en fintandad såg. Montering (se sidan 6) Tryck och täthetsprov Termostatblandarens anslutningar skall täthetkontrolleras efter installationen. Tekniska data Driftstryck: max. 1 MPa Rek. driftstryck: 0,15-0,5 MPa Tryck vid provtryckning: 1,6 MPa (1 MPa = 10 bar = 147 PSI) Varmvattentemperatur: max. 70 C Rek. varmvattentemp.: 65 C Anslutningsmått: 160 mm Anslutningar M 26x1,5: kallt höger varmt vänster Termisk desinfektion: max. 70 C / 4 min Självspärr mot återflöde Produkten är enbart avsedd för dricksvatten! 4 (20)

Svenska Symbolförklaring Använd inte silikon som innehåller ättiksyra! Inställning av maxtemperatur (se sidan 10) Efter monteringen måste blandarens uttemperatur kontrolleras och ställas in på den temperatur som kunden vill ha. En korrigering krävs när den uppmätta temperaturen vid tappstället avviker från den temperatur som är inställd på termostaten. Safety Function (se sidan 11) Med hjälp av Safety Function kan du ställa in den önskade maximaltemperaturen till exempelvis 42ºC och så förhindra skållningsrisk för barn. Skötsel (se sidan 14) Backventilers funktion måste kontrolleras regelbundet enligt nationella eller regionala bestämmelser (DIN 1988 en gång per år) i enlighet med DIN EN 1717. För att garantera att termostaten ej kalkar igen, ska den regelbundet, en gång per vecka, konditioneras. Det sker genom att man några gånger snabbt slås om temperaturen från hett till kallt och tillbaka. Hantering (se sidan 12) Rengöring (se sidan 16) Måtten (se sidan 19) Flödesschema (se sidan 19) Huvuddusch Handdusch Reservdelar (se sidan 20) Specialtillbehör (medföljer ej leveransen) #98681000 Kakelutjämningsbricka krom Testsigill (se sidan 13) Felsökning Störning Orsak Åtgärd För lite vatten - Vattentrycket är för lågt - Kontrollera ledningstryck - Smutsfiltren är igensmutsade (97367000) - Rengör smutsfilter i anslutningarna och på styrenheten (97367000) - Silfiltret i duschen smutsigt - Rengör silfiltret mellan slangen och termostaten Korsflöde varmt vatten pressas vid avstängd ermostat in i kallvatten- - Backventil är igensmutsad eller otät - Rengör backventil, byt ut om nödvändigt inloppet, och vice versa Den faktiska vatten- temperaturen - Termostaten ställdes inte in - Justera termostaten stämmer Inte överens med den Inställda - Varmvattentemperaturen är för låg - Höj varmvattentemperaturen til mellan 42ºC och 65ºC Temperaturen kan ej ställas in - Termosensorn är igenkalkad - Byt termosensorn Varmvattenberedare slår ej på vid användning av termostaten - Smutsfiltren är igensmutsade - Rengör / byt smutsfilter - Backventil är defekt - Byt backventil Montering (Se Sidan 6) 5 (20)

Montage 1 2 2,5 mm 3 4 2,5 mm 5 The nuts of the installation plate must be tightened to the manufacturer's instructions. Muttrarna dras åt enligt monteringsanvisningen från leverantören av blandarfäste. 23 mm 6 (20)

6 7 3. 8 9 10 11 7 (20)

12 Tätskikt Kakellim Kakel Betong Ø 6 mm Ø 6 mm Silicone 50 mm 3. Silicone 4. Trä Tätskikt Kakellim Kakel Ø 6 mm When installing on a stud wall, the wall must always be strengthened. All screws must be fixed to solid structures, such as concrete, studs or special structural components. Screws must not be fixed to flooring or wall sheets alone. Requirements for sealing apply in wet zones 1 and Sealing materials must be fixed to the underlying layer and must be waterproof, mould-resistant and age-resistant. Silicone Vid montering på regelvägg måste väggen alltid förstärkas. Alla skruvinfästningar skall ske i massiv konstruktion, t.ex betong, i reglar eller särskild konstruktionsdetalj. Skruvinfästning får inte göras enbart i golv-, eller väggskiva. Krav på tätning gäller både i våtzon 1 och Material för tätning ska fästa mot underlaget och vara vattenbeständigt, mögelresistent och åldersbeständigt. 13a 13b 98681000 8 mm 8 mm 8 (20)

14 15 16 3 mm 17 18 8 mm 9 (20)

19 20 1 2 3 4 10 (20)

Safety Function 1 2 3. 3mm 3 4 for example 42 C till exempel 42 C! 5 6 3mm 2 Nm 3. 11 (20)

Bedienung open / öppna open / öppna close / stänga cold / kallt 12 (20) hot / varmt

Raindance Select S 120 3jet 26530000 RainAir Rain WhirlAir harder / tyngre easier / lättare 27233000 1377 13 (20)

Wartung 1 3. 2 3 mm 4. 23 mm 3 5. 4 5 6 mm 14 (20)

6 6 mm 7 8 9 3 mm 3. 23 mm 4. 5. 15 (20)

Reinigung EN Cleaning recommendation / Warranty / Contact SV Rengöringsrekommendationer / Garanti / Contacto www.hansgrohe.com/ cleaning-recommendation www.hansgrohe.com/ cleaning-recommendation www.hansgrohe.com/ cleaning-recommendation www.hansgrohe.com/ cleaning-recommendation 16 (20)

1 2 3 4 > 1 min 5 6 5 mm 17 (20)

7 8 5 mm 2 Nm 1 2 3 4 > 1 min 18 (20)

Raindance Showerpipe 27233000 65 585 Ø 80 7 7 Ø 240 40 465 Ø 22 105 1230 1230 307 2420 2620 2520 2270 2470 2370 Ø 38 G 1/2 1000 1200 1100 305 160 20 M 26x1,5 41 23 17 57 1 2 19 (20)

Serviceteile 95687000 98395000 (72x2) 98716000 98389000 (25x2) 98672000 98444000 (M6x8) SW 3 mm 98675000 98131000 (15x2,5) 98123000 (10x1,5) 98131000 (15x2,5) 98131000 (15x2,5) 98681000 98681000 98395000 (72x2) 95665000 98123000 (10x1,5) 98716000 98419000 (7x2) 98855000 98714000 95794000 SW 5 mm 26530000 20 (20) 98131000 (15x2,5) 98213000 (9x1) 97367000 98137000 (17x1,5) 95835000 96737000 98390000 (26x1,5) 98283000 95836000 98913000 95927000 (M34x1,5) 95843000 SW 27 mm 98382000 (12x2,25) 97708000 98282000 98129000 (14x2) 98058000 95836000 28276000 Hansgrohe AB Svangatn 2B 416 68 Göteborg Tele: +46(0)31-216600 Fax: +46(0)31-190103 E-post: info@hansgrohe.se Internet: www.hansgrohe.se 95843000 SW 3 mm 95839000 98390000 (26x1,5) 98913000 (M34x1,5) SW 27 mm 2019-02-27 9.02423.04