11600C l/h / l/s l/h / l/s. 30 kpa / 0.30 bar. 35 kpa / 0.35 bar kpa / 25 bar kpa / 25 bar. Rp 3/4 F EN

Relevanta dokument
11601D NOV 15. PCMTV32- F l/h / l/s ±5 % ±5 % ±5 % ±5 % ±5 % ±5 % PCMTV25- PCMTV32- F l/h / l/s

11723A JAN l/h / 5.0 l/s. 35 kpa / 0.35 bar kpa / 16 bar. Arrow on valve body

NOV B l/h / 5.0 l/s. 35 kpa / 0.35 bar kpa / 16 bar. Arrow on valve body

ARC 32. Tvättställsblandare/Basin Mixer. inr.se

LINC 23. Tvättställsblandare/Basin Mixer. inr.se A

Manual. SE Control Omni Dockningsstation GB Control Omni Docking station DE Control Omni Dockstation

Installatörshandbok Överskåp. Installer manual Top cabinet. Installateurhandbuch Oberschrank. Asentajan kasikirja Yläkaappi IHB SE LEK

HANDPUMP H-11 DIRECTIONS FOR USE BRUKSANVISNING GEBRAUCHANWEISUNG

Your No. 1 Workout. MANUAL pro

PPV-Serie. DIN Axialkolben Verstellpumpe für LKW Nebenabtrieb mit Load Sensing-Regler. Erstinbetriebnahme: Saugstutzen muß separat bestellt werden

4.2 Konstantes Fördervolumen Doppelpume

WALLMEK i Kungälv AB Special tools for auto repairs

CTC Rumsdisplay CTC Roomdisplay Installations- och skötselanvisning. Installation and maintenance instructions

90º. Mounting of actuator with an adapter

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENS LÄS IGENOM INSTRUKTIONSMANUALEN

Power consumption. Control signal. time, actuator. or On/off (3-wire) V DC or 0. (3-wire) (3-wire) (3-wire)

Veranda. DE Installationshandbuch V17/16

Metallmaßstäbe RL. Inhaltsverzeichnis

F1220, F1230, F1120, F1130

Logik für Informatiker

VASSVIK FIXED STAND SE / ENG

SVENSKA. Bottensugkontakt Art.nr 12673

Windlass Control Panel v1.0.1

Får endast utföras av behörig personal. May only be carried out by authorized electrician

Parasol base stand granite Parasollfot granit / Parasollfot granitt / Sonnenschirmfuß Granit / Aurinkovarjon jalka, graniittia

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

WALLMEK i Kungälv AB Special tools for auto repairs

Rajd Instruction. Svenska Deutsch English

Molift Raiser 75135G Etac Box 203, Anderstorp Sweden Tel Fax

BOW. Art.nr

The thermostatic head must be mounted in a horizontal position.

BATH MIXER 160 LINC 21. incl. HAND SHOWER. inr.se

THERMOMATIC 125 User and installation instructions

WALLMEK i Kungälv AB Special tools for auto repairs

Tariff Kit. Installatörshandbok Tariff Kit för NIBE F1330 LEK. Installer manual Tariff Kit for NIBE F1330

Nathi Skötbord Changing unit Table à langer murale Wickeltisch Verschoontafel Puslebord Cambiador de pared Přebalovací pult Fasciatoio

DAMPER EQAZ-12, EQAZ-13, STAZ-30, STBZ-30

Bruksanvisning Direction of use Gebrauchsanleitung

Anvisning för Guide for

POSH. Art.nr

SCdefault. 9-5 Monteringsanvisning

FORTA M315. Installation. 218 mm.

STRICT Art.nr ,

Accepterad monteringsanvisning 2016:1. Metris (RSK: ) Metris S (RSK: ) Metris (RSK: )

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK

Bruksanvisning Directions for use

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) 1 (12)

Spotlight Set Spotlightset / Spotlightsett

manual Facial spa Art nr: Rubicson

Original instructions VOT TRVS SD

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENSLÄS IGENOM INSTRUKTIONSMANUALEN NOGGRANT

Instruction Manual. Svenska, English. Power Bank. Model: PRBN

F1220, F1230, F1120, F1130

Users manual Bruksanvisning Gebrauchanweisung Guide d instructions

Komponenter Removed Serviceable

PCMTV Tryckoberoende reglerventiler, DN32- DN50 med integrerad flödesbegränsare och differenstrycksregulator för värmekällor

Viktig information för transmittrar med option /A1 Gold-Plated Diaphragm

Gebrauchsanweisung. Bure. Gehwagen. Bure XL

Product configurations Produire configuration Produkt konfigurationen Producto configuraciones Produkt konfigurationerna

CASUAL. Art.nr

BEAM. Product Manual Produktmanual

Technical description with installation and maintenance instructions

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S 100 CoolStart (RSK: )

Storlek/ Size. Modell/ Model. Effekt/ Effect. Vattenmängd/ Water amount T30 63W T30 87W T30 67W T30 76W T30 108W T30 121W

Contents / Innehållsförteckning

Installationsanvisning

SAFETY PRECAUTIONS SPECIFICATIONS

Montageanvisning Airway system 1000/1500 Assembly instruction Airway system 1000/1500

CANALKLER 250S. Gänga i tum Thread in inch

MCP-16RC, Air Purification

Användarhandbok. MHL to HDMI Adapter IM750

Original instructions VMT TRVS SDM24 ST

Christmas tree lighting Julgransbelysning / Juletrebelysning

TAXUD/801/2004 DE Nachtrag Nr.: 2 Datum: Das Handbuch Versandverfahren wird wie folgt geändert:

PCMTV25 / PCMTV32. Tryckoberoende reglerventiler, DN25- DN32 med integrerad flödesbegränsare för värmekällor och differenstryckregulator

81152 TRANSFER CASE SHIFT HANDLE

PCMTV Tryckoberoende reglerventiler, DN20- DN32 med integrerad flödesbegränsare för värmekällor och differenstryckregulator

Joki Joki Air. JCD70-xx JAD90-xx. lasiesta.com. Manual. Betriebsanleitung. Manuel. Manual. Manuale. Gebruiksaanwijzing.

BPS BPS 8920_21_22 DN Lönsam flödesteknik Rewarding Flow Technology Vorteilhafte Regel- und Absperrtechnik

Shower cabins / Steam cabins

Accepterad monteringsanvisning 2016:1. Ecos M CoolStart (RSK: ) Ecos L CoolStart (RSK: ) 1 (12)

Montageanvisning Airway system 1000/1500 Assembly instruction Airway system 1000/1500

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S (RSK: ) 1 (12)

Accepterad monteringsanvisning 2016:1

SERVICEINSTRUKTION Värmeproduktion. SERVICE INSTRUCTION Heat production. Wärmeerzeugung SIT SE/GB/DE M10383 FIGHTER 1320

Assembly instruction Kit 200

MANUAL PURMO MINIMIX SHUNT

#1230 RÖKLÅDA SMOKING OVEN RÄUCHEROFEN.

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

Boiler with heatpump / Värmepumpsberedare

AirCare - Bakteriekontroll i offentliga utrymmen

Support Manual HoistLocatel Electronic Locks

LINC 23 TVÄTTSTÄLLSBLANDARE

Monterings- och bruksanvisning EB 8091 SV. Pneumatisk mikroventil Typ och typ Typ med120 cm 2 ställdon

R min. 5 max

ASSEMBLY INSTRUCTIONS SCALE - SYSTEM

SERVICEINSTRUKTION Tider. SERVICE INSTRUCTION Times. Zeiten SIT SE/GB/DE M10401 FIGHTER 2005/2010

Installation Instructions

Aspekte zur Character Semantik

Nordic. info@monoflex.se Phone (SE) : 0046 (0) Fax (SE) : 0046 (0)

Transkript:

PCMTV15 / PCMTV25 i Read this instruction before installation of the product. Subject to change without notice. Consult documentation in all cases where this symbol is used, in order to fi nd out the nature of the potentional hazards and any actions to be taken. Installation and maintenance of this unit should only be carried out by skilled workers. The manufacturer is not responsible for any damages caused by inadequate skills during installation and/or by any safety devices having been removed or tampered with. Always protect the pressure regulator by using strainers upstream of the valve. Make sure that the water quality complies with UNI 8065 standards (Fe < 0.5 mg/kg and Cu < 0.1 mg/kg). Furthermore, the maximum iron oxide in the water passing through the control valve (PICV) should not exceed 25 mg/kg (25 ppm). To ensure the main pipework is cleaned appropriately, fl ushing by-passes should be used without fl ushing through the pressure regulator of the PICV thereby preventing debris that might clog the valve. During cleaning operation of the valve use a damp cloth, do not use any detergent or chemical solvent that could seriously damage the parts. Box 116, SE-428 22 Kållered, Sweden Tel: +46 31 720 02 00, Fax: +46 31 720 02 50 www.regincontrols.com, info@regin.se 11600C NOV 15 For some valve models, depending on the max. set fl ow rate, noise above 50 db may be generated at high differential pressure values. Technical data PCMTV15-F150 PCMTV15-F600 PCMTV15-F780 PCMTV20-F1000 PCMTV20-F1500 PCMTV25-F1500 Max. fl ow rate 150 l/h / 0.042 l/s 600 l/h / 0.167 l/s 780 l/h / 0.217 l/s 1000 l/h / 0.278 l/s 0.417 l/s 0.417 l/s Max. fl ow accuracy ±5 % ±5 % ±5 % ±5 % ±5 % ±5 % [ p 0.3 1 bar] Start-up p Q=const. 20 kpa / 0.20 bar 25 kpa / 0. 0.35 bar 30 kpa / 0.30 bar 0.35 bar 0.35 bar Max. p 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar Temperature -10...+120 C -10...+120 C -10...+120 C -10...+120 C -10...+120 C -10...+120 C Max. working pressure Connections Rp 1 F Flow Manual flow pre-setting device Lift up locking device. Select fl ow rate by rotating the pre-setting ring. Push down locking device. PCMTV15-F150 PCMTV15-F600 PCMTV15-F780 PCMTV20-F1000 PCMTV20-F1500 PCMTV25-F1500 Pre-setting % Flow l/h Flow l/s Flow l/h Flow l/s Flow l/h Flow l/s Flow l/h Flow l/s Flow l/h Flow l/s Flow l/h Flow l/s 100 150 0.042 600 0.167 780 0.217 1000 0.278 1500 0.417 1500 0.417 90 135 0.038 540 0.150 702 0.195 900 0.250 1350 0.375 1350 0.375 80 120 0.033 480 0.133 624 0.173 800 0.222 1200 0.333 1200 0.333 70 105 0.029 420 0.117 546 0.152 700 0.194 1050 0.292 1050 0.292 60 90 0.025 360 0.100 468 0.130 600 0.167 900 0.250 900 0.250 50 75 0.021 300 0.083 390 0.108 500 0.139 750 0.208 750 0.208 40 60 0.017 240 0.067 312 0.087 400 0.111 600 0.167 600 0.167 30 45 0.013 180 0.050 234 0.065 300 0.083 450 0.125 450 0.125 20 - - 120 0.033 156 0.043 200 0.056 - - - - 10 - - 60 0.017 78 0.022 100 0.028 - - - - 1

Pressure reading for verifications If P1-P2 > start-up pressure, then the valve is within the working range (see technical data). Q Q CONST Q=CONST P2 = L pressure port START-UP PRESSURE P1 = H pressure port 25 kpa Control valve actators Thermal-electric actuator Remove the handwheel. Screw on the ring adaptor. Push down the actuator. Electro-mechanical actuator Remove the handwheel. Screw on the ring adaptor. Screw the nut actuator into place. Mounting position: Any position between vertical and horizontal. Avoid upside down mounting! 2

PCMTV15 / PCMTV25 i Läs denna instruktion innan produkten monteras och ansluts. Kan ändras utan föregående notis. Följ alltid de anvisade säkerhetsföreskrifterna i dokumentationen för att förebygga risken för brand, elstöt och personskador. Installation eller underhåll av denna enhet ska endast utföras av kvalifi cerad personal. Tillverkaren är inte på något sätt ansvarig för eventuella skador som kan uppkomma p.g.a. bristande kompetens eller färdighet under installationen, eller på grund av att installatören tagit bort eller gjort ändringar i enhetens inbyggda säkerhetsmekanismer. Se till att alltid skydda tryckregulatorn genom att installera smutsfi lter uppströms innan ventilen. Se även till att vattenkvaliteten alltid överensstämmer med standarderna för UNI 8065 (Fe < 0,5 mg/kg och Cu < 0,1 mg/kg). Dessutom bör järnoxidsnivån i den vattenström som passerar genom reglerventilen ej överskrida 25 mg/kg (25 ppm). För att säkerställa att huvudledningen rensas ur ordentligt bör bypassventiler användas vid urspolningen. Detta förhindrar att reglerventilen täpps igen av avlagringar. En fuktig trasa ska användas för ventilrengöringen. Använd ej något rengöringsmedel eller lösningsmedel då detta kan orsaka allvarliga skador på känsliga delar. Box 116, SE-428 22 Kållered Tel: +46 31 720 02 00, Fax: +46 31 720 02 50 www.regin.se, info@regin.se 11600C NOV 15 För vissa ventilmodeller kan missljud komma att uppstå beroende på maximalt inställd fl ödeshastighet. Vid höga differenstrycksvärden kan oljud som överskrider 50 db genereras. Tekniska data PCMTV15-F150 PCMTV15-F600 PCMTV15-F780 PCMTV20-F1000 PCMTV20-F1500 PCMTV25-F1500 Max. fl ödeshastighet 150 l/h / 600 l/h / 780 l/h / 1000 l/h / 0,042 l/s 0,167 l/s 0,217 l/s 0,278 l/s Flödesnoggrannhet [ p 0,2...1 bar] ±5 % ±5 % ±5 % ±5 % ±5 % ±5 % Uppstart p Q=konst. 20 kpa / 0,20 bar 25 kpa / 0, 30 kpa / 0,30 bar Max. p 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar Temperatur -10...+120 C -10...+120 C -10...+120 C -10...+120 C -10...+120 C -10...+120 C Flöde Max. arbetstryck Anslutningar Rp 1 F Manuell förinställning av flöde Lyft låsanordningen. Välj fl ödeshastighet genom att vrida på ringen för förinställning. Tryck ned låsanordningen. PCMTV15-F150 PCMTV15-F600 PCMTV15-F780 PCMTV20-F1000 PCMTV20-F1500 PCMTV25-F1500 Förinställning % Flöde l/h Flöde l/s Flöde l/h Flöde l/s Flöde l/h Flöde l/s Flöde l/h Flöde l/s Flöde l/h Flöde l/s Flöde l/h Flöde l/s 100 150 0,042 600 0,167 780 0,217 1000 0,278 1500 0,417 1500 0,417 90 135 0,038 540 0,150 702 0,195 900 0,250 1350 0,375 1350 0,375 80 120 0,033 480 0,133 624 0,173 800 0,222 1200 0,333 1200 0,333 70 105 0,029 420 0,117 546 0,152 700 0,194 1050 0,292 1050 0,292 60 90 0,025 360 0,100 468 0,130 600 0,167 900 0,250 900 0,250 50 75 0,021 300 0,083 390 0,108 500 0,139 750 0,208 750 0,208 40 60 0,017 240 0,067 312 0,087 400 0,111 600 0,167 600 0,167 30 45 0,013 180 0,050 234 0,065 300 0,083 450 0,125 450 0,125 20 - - 120 0,033 156 0,043 200 0,056 - - - - 10 - - 60 0,017 78 0,022 100 0,028 - - - -

Tryckavläsning i verifikationssyfte Om P1-P2 > uppstartstryck så befi nner sig ventilen inom mätområdet (se tekniska data). Q Q KONST Q=KONST P2 = L tryckport UPPSTARTSTRYCK P1 = H tryckport 25 kpa Ställdon för reglerventiler Termoelektriska ställdon Ta bort ratten. Skruva fast ringadaptern. Tryck ned ställdonet. Elektromekaniska ställdon Ta bort ratten. Skruva fast ringadaptern. Skruva fast ställdonsmuttern. Monteringsläge: Alla lägen mellan vertikalt och horisontellt. Undvik montage upp och ned! 2

PCMTV15 / PCMTV25 i Lesen Sie diese Montageanleitung vor der Montage des Produktes durch. Änderungen der Informationen in diesem Dokument sind vorbehalten. Dieses Symbol macht auf eventuelle Gefahren bei der Handhabung des Produktes sowie auf in der Dokumentation nachzulesende Maßnahmen aufmerksam. Montage und Wartung dieses Geräts dürfen nur von Fachkräften durchgeführt werden. Der Hersteller haftet nicht für Schäden, die durch mangelnde Fachkenntnisse bei der Installation und/oder Sicherheitsvorkehrungen, die entfernt oder manipuliert wurden, verursacht werden. Schützen Sie den Differenzdruckregler immer durch ein Sieb, das vor dem Ventil eingesetzt wird. Stellen Sie sicher, dass die Wasserqualität mit den Normen UNI 8065 (Fe < 0,5 mg/kg und Cu < 0,1 mg/kg) übereinstimmt. Darüber hinaus darf der max. Eisenoxidgehalt im Wasser, das durch das Regelventil (PICV) fl ießt, den Wert von 25 mg/kg (25 ppm) nicht übersteigen. Um sicherzustellen, dass das Hauptrohrsystem ausreichend gereinigt wird, sollten Spül-Bypässe eingesetzt werden, um nicht den PICV-Differenzdruckregler zu spülen, und um so zu verhindern, dass das Ventil durch Schmutz verstopft wird. Regin Controls Deutschland GmbH Tel: +49 30 77 99 40, Fax: +49 30 77 99 479 www.regincontrols.de, info@regincontrols.de 11600C NOV 15 Benutzen Sie für die Reinigung des Ventils ein feuchtes Tuch. Benutzen Sie keine Reinigungs mittel oder Chemikalien, die die Einzelteile stark beschädigen könnten. Bei einigen Ventilmodellen kann es, je nach eingestelltem Maximalwert für den uss, bei hohen Differenzdruckwerten zu einer Geräuschbildung von über 50 db kommen. Technische Daten PCMTV15-F150 PCMTV15-F600 PCMTV15-F780 PCMTV20-F1000 PCMTV20-F1500 PCMTV25-F1500 Manuelle uss-voreinstellung Heben Sie die Verriegelungsvorrichtung an. Wählen Sie durch Drehen des Voreinstellungsrings den gewünschten usswert aus. Drücken Sie die Verriegelungsvorrichtung wieder herunter. PCMTV15-F150 PCMTV15-F600 PCMTV15-F780 PCMTV20-F1000 PCMTV20-F1500 PCMTV25-F1500 Voreinstellung % Max. uss 150 l/h / 0,042 l/s 600 l/h / 0,167 l/s 780 l/h / 0,217 l/s 1000 l/h / 0,278 l/s Max. ussgenauigkeit ±5 % ±5 % ±5 % ±5 % ±5 % ±5 % [ p 0,3 1 bar] Inbetriebnahme p Q = Konst. 20 kpa / 0,20 bar 25 kpa / 0, 30 kpa / 0,30 bar Max. p 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar 600 kpa / 6 bar Temperatur -10...+120 C -10...+120 C -10...+120 C -10...+120 C -10...+120 C -10...+120 C Max. Arbeitsdruck Anschlüsse Rp 1/2" F Rp 1/2" F Rp 1/2" F Rp 3/4" F Rp 3/4" F Rp 1" F uss 100 150 0,042 600 0,167 780 0,217 1000 0,278 1500 0,417 1500 0,417 90 135 0,038 540 0,150 702 0,195 900 0,250 1350 0,375 1350 0,375 80 120 0,033 480 0,133 624 0,173 800 0,222 1200 0,333 1200 0,333 70 105 0,029 420 0,117 546 0,152 700 0,194 1050 0,292 1050 0,292 60 90 0,025 360 0,100 468 0,130 600 0,167 900 0,250 900 0,250 50 75 0,021 300 0,083 390 0,108 500 0,139 750 0,208 750 0,208 40 60 0,017 240 0,067 312 0,087 400 0,111 600 0,167 600 0,167 30 45 0,013 180 0,050 234 0,065 300 0,083 450 0,125 450 0,125 20 - - 120 0,033 156 0,043 200 0,056 - - - - 10 - - 60 0,017 78 0,022 100 0,028 - - - - 1

Druckmesswert für Prüfungszwecke Wenn P1-P2 > Einschaltdruck ist das Ventil innerhalb des Arbeitsbereichs (siehe technische Daten). Q Q KONST Q=KONST P2 = Druckanschluss L EINSCHALT- DRUCK P1 = Druckanschluss H 25 kpa Regelventil-Stellantriebe Thermoelektrischer Stellantrieb Entfernen Sie das Handrad. Schrauben Sie den Ringadapter auf. Drücken Sie den Stellantrieb herunter. Elektromechanischer Stellantrieb Entfernen Sie das Handrad. Schrauben Sie den Ringadapter auf. Schrauben Sie die Mutter des Stellantriebs in Position fest. Montageposition: Jede Position zwischen senkrecht und waagerecht möglich. Vermeiden Sie die Montage mit der Spitze nach unten! 2