BBT057/ BBC057 BBCD057/ BBT057-NL HOLDEN COLORADO 9/2016+ HOLDEN TRAILBLAZER WD & 4WD Models

Support Manual HoistLocatel Electronic Locks

RADIATION TEST REPORT. GAMMA: 30.45k, 59.05k, 118.8k/TM1019 Condition D

Installation Instructions

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

Installation Instructions

Remote control Fjärrströmbrytare / Fjernstrømbryter

Bathtub Filler CN EN. TBP02201 Type / TBP02202 Type. Installation Manual. Continued on the back cover

Styrteknik: Binära tal, talsystem och koder D3:1

Windlass Control Panel v1.0.1

SVENSK STANDARD SS-ISO :2010/Amd 1:2010

SkillGuide. Bruksanvisning. Svenska

2.45GHz CF Card Reader User Manual. Version /09/15

BBT042/ BBC042/ BBCD042 NISSAN NAVARA D40 V STX & PATHFINDER R WD & 4WD Models

CanCom Bluetooth BLUETOOTH V5.6. Specifikation Specification LED. transceiver

Beijer Electronics AB 2000, MA00336A,

SAFETY PRECAUTIONS SPECIFICATIONS

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK

Ersättning styrkort GOLD, stl 1-3, Version 1-3/ Replacement control circuit board GOLD, sizes 1-3, Version 1-3

säkerhetsutrustning / SAFETY EQUIPMENT

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) 1 (12)


Accepterad monteringsanvisning 2016:1. Metris (RSK: ) Metris S (RSK: ) Metris (RSK: )

Användarhandbok. MHL to HDMI Adapter IM750

Fig. 2: Inkoppling av lindningarna / Winding wiring diagram

Isolda Purchase - EDI

Laboration i digitalteknik Datablad

81152 TRANSFER CASE SHIFT HANDLE

nwind and nwind-race transducer Twin Fin Installation Manual English Installationsmanual Svensk

Rev No. Magnetic gripper 3

Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

Product configurations Produire configuration Produkt konfigurationen Producto configuraciones Produkt konfigurationerna

Quick Start. English Svenska PRIMACY. Printing settings and winsign


SAFETY PRECAUTIONS SPECIFICATIONS

INDUKTIV SLINGDETEKTOR INDUCTIVE LOOP DETECTOR

Montageanvisning Airway system 1000/1500 Assembly instruction Airway system 1000/1500

Dokumentnamn Order and safety regulations for Hässleholms Kretsloppscenter. Godkänd/ansvarig Gunilla Holmberg. Kretsloppscenter

Quick Start Guide Snabbguide

Företagsnamn: Grundfos Skapad av: Magnus Johansson Tel: +46(0) Datum:


Installation Instructions

Montageanvisning Airway system 1000/1500 Assembly instruction Airway system 1000/1500


SVENSK STANDARD SS-ISO 8734

InstalationGuide. English. MODEL:150NHighGain/30NMiniUSBAdapter

RSMFM-2R MULTIFUNCTIONAL

SVENSK STANDARD SS-EN ISO :2009/AC:2010

District Application for Partnership

Laboration i digitalteknik Datablad

Schenker Privpak AB Telefon VAT Nr. SE Schenker ABs ansvarsbestämmelser, identiska med Box 905 Faxnr Säte: Borås

CanCom Multimodul 30

Spotlight Set Spotlightset / Spotlightsett

Får endast utföras av behörig personal. May only be carried out by authorized electrician

Teknisk support finns tillgänglig Måndag-Fredag 08:00-16:30. Övrig dokumentation finns tillgänglig på Teletecs hemsida -

Verktyg som behövs. LX HD Sit-Stand Desk Mount LCD Arm SVENSKA. 20" (508 mm) lbs ( kg)

Användarhandbok. USB Charging Dock DK52

Diskant Yta eller Vikelfäste montering Mount

Installation Instructions

PFC and EMI filtering

Grafisk teknik IMCDP IMCDP IMCDP. IMCDP(filter) Sasan Gooran (HT 2006) Assumptions:

2.1 Installation of driver using Internet Installation of driver from disk... 3

LX Desk Mount LCD Arm

BBT014/ BBC014/ BBCD014 PJ & PK FORD RANGER WD & 4WD Models

BEAM. Product Manual Produktmanual

SVENSK STANDARD SS-EN ISO 19108:2005/AC:2015

Industrial valves 4 5

Eurokod 3: Dimensionering av stålkonstruktioner Del 4-3: Rörledningar. Eurocode 3 Design of steel structures Part 4-3: Pipelines

Grafisk teknik IMCDP. Sasan Gooran (HT 2006) Assumptions:

BRUKSANVISNING. Oscilla 910

Accepterad monteringsanvisning 2016:1

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S (RSK: ) 1 (12)

Application Note SW

SVENSK STANDARD SS-ISO 8779:2010/Amd 1:2014

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S 100 CoolStart (RSK: )

FÖRBERED UNDERLAG FÖR BEDÖMNING SÅ HÄR

Design Service Goal. Hantering av demonterbara delar som ingår i Fatigue Critical Baseline Structure List. Presentatör

Grafisk teknik. Sasan Gooran (HT 2006)

CANALKLER 250S. Gänga i tum Thread in inch

Ringmaster RM3 - RM 5 RM3 RM 4 RM 5

Produktens väg från idé till grav

DC-DC CONVERTER IP67

Lösenordsportalen Hosted by UNIT4 For instructions in English, see further down in this document

Alias 1.0 Rollbaserad inloggning

DSAB Spettrobot Modell SPRAYROD

* _0817* Drivsystemsteknik \ Drivsystemsautomation \ Systemintegration \ Service. Ändringar. MOVIMOT MM..D med växelströmsmotor DT/DV

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENS LÄS IGENOM INSTRUKTIONSMANUALEN

VASSVIK FIXED STAND SE / ENG

Transkript:

Installation Instructions at. No. 794-VHS 3 7 2 English 6 4 5 Note: This module must be used with 794-AN5 or 794-ANR5 series B or later ontrolnet adapters in ontrolnet systems. Module Installation This module mounts on a 794 terminal base unit.. Rotate keyswitch () on terminal base unit (2) clockwise to position as required for this type of module. 2. Make certain the flexbus connector (3) is pushed all the way to the left to connect with the neighboring terminal base/adapter. You cannot install the module unless the connector is fully extended. 3. Make sure that the pins on the bottom of the module are straight so they will align properly with the connector in the terminal base unit. 4. Position the module (4) with its alignment bar (5) aligned with the groove (6) on the terminal base. 5. Press firmly and evenly to seat the module in the terminal base unit. The module is seated when the latching mechanism (7) is locked into the module. FLEX I/O is a trademark of Rockwell Automation Publication 794-5.67 December 998

2 24V dc FLEX I/O 2 hannel Very High Speed ounter Module! ATTENTION: Remove field-side power before removing or inserting this module. This module is designed so you can remove and insert it under backplane power. When you remove or insert a module with field-side power applied, an electrical arc may occur. An electrical arc can cause personal injury or property damage by: sending an erroneous signal to your system s field devices causing unintended machine motion causing an explosion in a hazardous environment Repeated electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance. European Union Directive ompliance If this product has the E mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives. EM Directive This product is tested to meet ouncil Directive 89/336/EE Electromagnetic ompatibility (EM) and the following standards, in whole or in part, documented in a technical construction file: EN 58-2 EM Generic Emission Standard, Part 2 Industrial Environment EN 582-2 EM Generic Immunity Standard, Part 2 Industrial Environment This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet ouncil Directive 73/23/EE Low Voltage, by applying the safety requirements of EN 63 2 Programmable ontrollers, Part 2 Equipment Requirements and Tests. For specific information required by EN 63-2, see the appropriate sections in this publication, as well as the following Allen-Bradley publications: Industrial Automation Wiring and Grounding Guidelines For Noise Immunity, publication 77-4. Automation Systems atalog, publication B This equipment is classified as open equipment and must be mounted in an enclosure during operation to provide safety protection. Publication 794-5.67 December 998

24V dc FLEX I/O 2 hannel Very High Speed ounter Module 3 onnecting Wiring to a 794-TB3G or 794-TB3GS Terminal Base onnect wiring to the terminal base as shown below. onnections for Terminal Base 794-TB3G shown 2 3 4 5 6 7 8 9 2 3 4 5 A A B B Z Z O O A A B B Z Z O2 O3 24V Inputs 24V Inputs 6 7 8 9 2 2 22 23 24 25 26 27 28 29 3 3 32 33 A A B B Z Z R R A A B B Z Z R2 R3 hassis Gnd 5V Inputs 5V Inputs hassis Gnd 34 35 36 37 38 39 4 4 42 43 44 45 46 47 48 49 5 5 +24V OM +V V 6 hassis Ground +V V +24V OM for Shields Where: A, A incremental encoder input A (+5 or +24V dc) B B incremental encoder input B (+5 or +24V dc) Z, Z incremental encoder input Z (+5 or +24V dc) O = sourcing outputs R = returns for sourcing outputs +V = +5 or +24V dc isolated power externally supplied for outputs (A max.) V = negative isolated power connection (A max.) +24V dc = 24V dc terminal base power for module OM = return for +24V dc terminal base power for module hassis Gnd = chassis ground for input or output cable shields ATTENTION: To reduce susceptibility to noise, power the high speed counter module and digital modules from separate power supplies. Do not exceed a length of 33 ft (m) for dc power cabling. ATTENTION: Do not daisy chain power or ground from this terminal base unit to any ac or dc digital module terminal base units. ATTENTION: Total current draw through the terminal base unit is limited to A. Separate power connections to the terminal base unit may be necessary. Publication 794-5.67 December 998

4 24V dc FLEX I/O 2 hannel Very High Speed ounter Module Indicators Allen-Bradley VERY HIGH SPEED OUNTER MODULE 794 VHS OUT OUT A B Z A B Z 2 3 B A A = Power/status indicator indicates power applied to module and status of module. B = Insertable label for writing individual I/O assignments. = Status Indicators A = Status of input A B = Status of input B Z = Status of gate input Z OUT = Status of individual output Publication 794-5.67 December 998

24V dc FLEX I/O 2 hannel Very High Speed ounter Module 5 Input Image Bit 5 4 3 2 9 8 7 6 5 4 3 2 Word Read hannel urrent ount (least significant word) hannel urrent ount (most significant word) 2 hannel urrent ount (least significant word) 3 hannel urrent ount (most significant word) 4 hannel Stored/Accumulated ount (least significant word) 5 hannel Stored/Accumulated ount (most significant word) 6 hannel Stored/Accumulated ount (least significant word) 7 hannel Stored/Accumulated ount (most significant word) 8 PE FP NR TF OS 3 OS 2 OS OS ZF ZS ZF ZS Where: PE = Programming error (error code in bits :) FP = Field power (24V dc power lost) NR = Not ready (configuring field programmable gate array FPGA) TF = Test fail flag = (indicating failure during powerup) red indicator on. ode in bits 2: indicate fail code ( = RAM; 2 = ROM; 3 = EEPROM; 4 = FPGA) Test flag = with red indicator blinking, upper byte of counter control word is non zero in production test mode. OS = Output status (current state of output), = Stored data count ZF = Zero frequency detected ZS = Z input status Publication 794-5.67 December 998

6 24V dc FLEX I/O 2 hannel Very High Speed ounter Module Output Image Bit 5 4 3 2 9 8 7 6 5 4 3 2 Word Write Reserved for Test L 3 O E 3 F O 3 L 2 2 hannel PWM Output Value ( 95.%) 3 hannel PWM Output Value ( 95.%) O E 2 Where: VR = Value reset of stored/accumulated count (channel) P = ounter preset (channel) R = ounter reset (channel) L = Local control (channel) outputs remain under control when flexbus is unpowered = enabled. OE = Output enable (channel) permitting output to be turned on from FO, compare match or PWM = enabled FO = Force output (channel) = on PWM = Pulse width modulation ( 95 decimal) F O 2 V R L P O E R F O V R L P O E R F O onfiguration Image Bit 5 4 3 2 9 8 7 6 5 4 3 2 Word Write ounter onfiguration Filter Selection 2 Time Base Value/PWM Period 3 hannel Gate Interval 4 hannel Gate Interval 5 Reserved 6 hannel Rollover Value (least significant word) 7 hannel Rollover Value (most significant word) 8 hannel Rollover Value (least significant word) 9 hannel Rollover Value (most significant word) hannel Preset Value (least significant word) hannel Preset Value (most significant word) 2 hannel Preset Value (least significant word) 3 hannel Preset Value (most significant word) Publication 794-5.67 December 998

24V dc FLEX I/O 2 hannel Very High Speed ounter Module 7 Bit 5 4 3 2 9 8 7 6 5 4 3 2 Word Write 4 hannel Scaler 5 hannel Scaler 6 S4 S3 S2 S F4 F3 F2 F 7 S4 S3 S2 S F4 F3 F2 F 8 S4 S3 S2 S F4 F3 F2 F 9 S4 S3 S2 S F4 F3 F2 F 2 First ounter st ON Value (least significant word) 2 First ounter st ON Value (most significant word) 22 First ounter st OFF Value (least significant word) 23 First ounter st OFF Value (most significant word) 24 First ounter 2nd ON Value (least significant word) 25 First ounter 2nd ON Value (most significant word) 26 First ounter 2nd OFF Value (least significant word) 27 First ounter 2nd OFF Value (most significant word) 28 First ounter 3rd ON Value (least significant word) 29 First ounter 3rd ON Value (most significant word) 3 First ounter 3rd OFF Value (least significant word) 3 First ounter 3rd OFF Value (most significant word) 32 First ounter 4th ON Value (least significant word) 33 First ounter 4th ON Value (most significant word) 34 First ounter 4th OFF Value (least significant word) 35 First ounter 4th OFF Value (most significant word) 36 Second ounter st ON Value (least significant word) 37 Second ounter st ON Value (most significant word) 38 Second ounter st OFF Value (least significant word) 39 Second ounter st OFF Value (most significant word) 4 Second ounter 2nd ON Value (least significant word) 4 Second ounter 2nd ON Value (most significant word) 4 Second ounter 2nd OFF Value (least significant word) 43 Second ounter 2nd OFF Value (most significant word) 44 Second ounter 3rd ON Value (least significant word) Publication 794-5.67 December 998

8 24V dc FLEX I/O 2 hannel Very High Speed ounter Module Bit 5 4 3 2 9 8 7 6 5 4 3 2 Word Write 45 Second ounter 3rd ON Value (most significant word) 46 Second ounter 3rd OFF Value (least significant word) 47 Second ounter 3rd OFF Value (most significant word) 48 Second ounter 4th ON Value (least significant word) 49 Second ounter 4th ON Value (most significant word) 5 Second ounter 4th OFF Value (least significant word) 5 Second ounter 4th OFF Value (most significant word) 52 ounter ontrol Safe State 53 Output ontrol Safe State 54 hannel PWM Safe State 55 hannel PWM Safe State Publication 794-5.67 December 998

24V dc FLEX I/O 2 hannel Very High Speed ounter Module 9 ounter onfiguration/mode (onfiguration Word ) Bit 7 6 5 4 3 2 ounter Bit 5 4 3 2 9 8 ounter Mode onfiguration Description ounter Encoder X Encoder X2 PWM Encoder X4 Period/Rate ontinuous/rate Rate Measurement Store count disabled Mode Store/ontinue Mode 2 Store;Wait/Resume Mode 3 Store;Reset/Wait/Start Mode 4 Store;Reset/Start and Reserved Z input NOT inverted Z input inverted Publication 794-5.67 December 998

24V dc FLEX I/O 2 hannel Very High Speed ounter Module Filter Selection (onfiguration Word ) Bit 7 6 5 4 3 2 ounter Bit 5 4 3 2 9 8 ounter ZF BF AF Filter Description No Filter 5kHz (µs + µs/.6µs) 5kHz (µs + µs/ 3.2µs) 5Hz (.ms + ms/ 25µs) 5Hz (.ms + ms/.25ms) A input not filtered A input filtered B input not filtered B input filtered Z input not filtered Z input filtered Publication 794-5.67 December 998

24V dc FLEX I/O 2 hannel Very High Speed ounter Module Specifications 794-VHS Very High Speed ounter Module Input Specifications Number of ounters 2 Number of Inputs per ounter Input Voltage Input urrent (typical) Input Off-State Voltage Input Off-State urrent Input On-State Voltage Input On-State urrent 2 groups of A/A, B/B, and Z/Z pairs with 5V dc or 5-24V dc terminations 5V dc or 5-24V dc (determined on terminal base terminations) 5V dc terminations: 9.mA @ 5V dc 25.7mA @ 6V dc 5-24V dc terminations: 6.mA @ 5V dc.2ma @ 24V dc 5V dc terminations: <.25V dc 5-24V dc terminations: <.8V dc <.25mA 5V dc terminations: >2.6V dc 5-24V dc terminations: >2.5V dc >5mA On-State Voltage Maximum 5V dc terminations: +6V 5-24V dc terminations: Refer to derating curve below. Input Frequency Maximum.MHz counter and encoder X (no filters) 5kHz encoder X2 (no filters) 25kHz encoder X4 (no filters) Input Filter Selections 5: Off, µs, µs,.ms,.ms per A/B/Z group Specifications continued on the next page. Publication 794-5.67 December 998

2 24V dc FLEX I/O 2 hannel Very High Speed ounter Module Specifications 794-VHS Very High Speed ounter Module Output Specifications Number of Outputs Output ontrol Output Supply Voltage Range Off-State Leakage urrent 2 isolated groups of 2 (.5A max. @ 5V dc;.a max. @ 2 24V dc) Outputs can be tied to 8 compare windows 5-7V dc; -3V dc <.3mA On-State Voltage Drop 5V dc terminations:.9v dc @.5A 2-24V dc terminations:.9v dc @.A On-State urrent Maximum 5V dc terminations:.5a 2-24V dc terminations:.a Maximum urrent per Output pair 5V dc terminations:.5a 2-24V dc terminations:.a Short ircuit urrent 5V dc terminations:.9a 2-24V dc terminations: 4.A Outputs are short circuit protected and turn off until power is cycled. Delay Time Isolation Voltage Flexbus urrent Power Dissipation Thermal Dissipation Indicators Off to On On to Off Keyswitch Position 25µs (load dependent) 5µs (load dependent) % tested @ 85V dc for s between six isolated areas, including; flexbus module 24V dc power A/B/Z inputs A/B/Z inputs O/O and output power supply O2/O3 and output power supply 2 75mA @ 5V dc (with terminal base power off) 5W maximum @ 3.2V dc Specifications continued on the next page. Maximum 7. BTU/hr @ 3.2V dc green/red power/status indicator 6 yellow input status indicators logic side 4 yellow output status logic side Publication 794-5.67 December 998

24V dc FLEX I/O 2 hannel Very High Speed ounter Module 3 Specifications 794-VHS Very High Speed ounter Module General Specifications Module Location Dimensions Inches (Millimeters) External dc Power Supply Voltage Voltage Range Supply urrent Environmental onditions Operational Temperature Storage Temperature Relative Humidity Shock Operating Nonoperating Vibration onductors Wire Size ategory Agency ertification (when product is marked) at. No. 794-TB3G or -TB3GS Terminal Base.8H x 3.7W x 2.D (45.7 x 94. x 53.3) 24V dc nominal 9.2 to 3.2V dc (includes 5% ac ripple) ma @ 24V dc to 55 o (32 to 3 o F) 4 to 85 o ( 4 to 85 o F) 5 to 95% noncondensing (operating) 5 to 8% noncondensing (nonoperating) 3g peak acceleration, (+)ms pulse width 5g peak acceleration, (+)ms pulse width Tested 5g @ 5Hz per IE 68-2-6 2 gauge (4mm 2 ) stranded maximum 3/64 inch (.2mm) insulation maximum 2 SA certified SA lass I, Division 2 Groups A, B,, D certified UL listed E marked for all applicable directives User Manual Publication 794-6.5. Use this conductor category information for planning conductor routing. Refer to publication 77-4., Industrial Automation Wiring and Grounding Guidelines for Noise Immunity. Publication 794-5.67 December 998

4 24V dc FLEX I/O 2 hannel Very High Speed ounter Module 24V Input Derating urve 3 29 Input Voltage Input Voltage (V) 24 2 2 25 3 4 5 55 6 Ambient Temperature o The area within the curve represents the safe operating range for the module under various conditions of user supplied 24V dc supply voltages and ambient temperatures. This includes all possible mounting positions, including inverted horizontal. Publication 794-5.67 December 998

24V dc FLEX I/O 2 hannel Very High Speed ounter Module 5 User Manuals Thank you for purchasing this product. This product has a user manual associated with it. If you would like a manual, you can: download a free electronic version from the internet:: www.ab.com/manuals or www.theautomationbookstore.com purchase a printed manual by: contacting your local distributor or Rockwell Automation representative, visiting www.theautomationbookstore.com and placing your order calling.8.963.9548 (USA/anada) or.33.725.574 (Outside USA/anada) The publication number of the user manual for your product is listed under Specifications in this installation instruction. Publication 794-5.67 December 998

6 24V dc FLEX I/O 2 hannel Very High Speed ounter Module With major offices worldwide. World Headquarters, Allen-Bradley, 2 South Second Street, Milwaukee, WI 5324 USA, Tel: () 44 382-2 Fax: () 44 382-4444 Publication 794-5.67 December 998 Publication 794-5.67 December 998 PN95532 23 opyright 998 Allen-Bradley ompany, Inc. Printed in USA