MySelect S 240 Showerpipe (20)

Relevanta dokument
SV Bruksanvisning / Monteringsanvisning. Croma Showerpipe

Ecostat 1001 CL Ecostat 1001 CL (16)

Ecostat Comfort (RSK: ) Ecostat Comfort (RSK: ) 1 (16)

Marin² Showerpipe (20)

Croma Showerpipe (20)

Raindance Showerpipe (20)

Raindance Showerpipe (20)

Raindance Showerpipe (RSK: ) 1 (20)

Accepterad monteringsanvisning 2016:1. Raindance Showerpipe (RSK: ) 1 (20)

Ecostat 1001 SL (RSK: ) Ecostat 1001 SL (RSK: ) 1 (16)

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) 1 (12)

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S 100 CoolStart (RSK: )

Accepterad monteringsanvisning 2016:1. Metris (RSK: ) Metris S (RSK: ) Metris (RSK: )

Accepterad monteringsanvisning 2016:1. Ecos M CoolStart (RSK: ) Ecos L CoolStart (RSK: ) 1 (12)

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) Talis S² Variarc (RSK: ) Metris (RSK: )

Accepterad monteringsanvisning 2016:1. Focus (RSK: ) Focus 100 CoolStart (RSK: ) (RSK: )

Accepterad monteringsanvisning 2016:1. Talis S (RSK: ) Talis S (RSK: ) 1 (12)

Accepterad monteringsanvisning 2016:1

Accepterad monteringsanvisning 2016:1. Talis E ( ) ( ) Talis E 110 CoolStart ( )

Ecostat 1001 SL (RSK: ) Ecostat 1001 SL (RSK: ) 1 (16)

Original 600 SILICONE. 1 x. 3 x. 3 x

Logis (RSK: ) (RSK: ) (RSK: ) Logis 70 CoolStart (RSK: )

Raindance Select Showerpipe

East 600. x 33. x 33 x 7 x 7. x 6. x

BOW. Art.nr

BRIC MODELL A

Nathi Skötbord Changing unit Table à langer murale Wickeltisch Verschoontafel Puslebord Cambiador de pared Přebalovací pult Fasciatoio

BATH MIXER 160 LINC 21. incl. HAND SHOWER. inr.se

ARC 32. Tvättställsblandare/Basin Mixer. inr.se

(SV) Installationsmanual för duschkabiner och ångbastukabiner (EN) Installation manual for shower cabins and steam cabins

Shower cabins / Steam cabins

INSTALLATION INSTRUCTIONS

(SV) Installationsmanual för duschkabiner och ångbastukabiner (EN) Installation manual for shower cabins and steam cabins

Installation. Twice Nisch. Twice Corner SVENSKA ENGLISH

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENS LÄS IGENOM INSTRUKTIONSMANUALEN

VASSVIK FIXED STAND SE / ENG

LINC 23. Tvättställsblandare/Basin Mixer. inr.se A

Anvisning för Guide for

Installation Wall. Art. #

STRICT Art.nr ,

LINC Modell A

POSH. Art.nr

P650 - Takscreen. Installationsguide EN

Bathtub Filler CN EN. TBP02201 Type / TBP02202 Type. Installation Manual. Continued on the back cover

INSTALLATION. (SE) Duschkabin och ångbastu (UK) Shower cabins and steam cabins. Model

LINC MODELL 13. INR SVERIGE AB Kosterögatan 15 SE Malmö 13 EN 1428:2005+A1:2008

CASUAL. Art.nr

Bruksanvisning Directions for use

Windlass Control Panel v1.0.1

Raindance Showerpipe

Your No. 1 Workout. MANUAL pro

Monteringsanvisning Nödutrymningsbeslag ASSA 179E

LINC 22 SHOWER MIXER 150 SHOWER MIXER 160. inr.se

SAFETY PRECAUTIONS SPECIFICATIONS

VARIOBARRIER S/M MIMSAFE BY CHOICE

Plain A262. För T16 (T5) lysrör. Innehåll. Monteringsanvisning. A. Instruktion för rampmontering

LINC 23 TVÄTTSTÄLLSBLANDARE


Molift Raiser 75135G Etac Box 203, Anderstorp Sweden Tel Fax

Spotlight Set Spotlightset / Spotlightsett


MCP-16RC, Air Purification

Storlek/ Size. Modell/ Model. Effekt/ Effect. Vattenmängd/ Water amount T30 63W T30 87W T30 67W T30 76W T30 108W T30 121W

STANDARD. UTM Ingegerd Annergren UTMS Lina Orbéus. UTMD Anders Johansson UTMS Jan Sandberg

ASSEMBLY INSTRUCTIONS SCALE CIRCLE - STANDARD

INKOPPLINGSANVISNING ELTRYCKSLÅS WIRING DIAGRAM SOLENOID LOCK

Technical description with installation and maintenance instructions

ELENOR. Svensk generalagent H&G / Gesta Gård Strängnäs SWEDEN Tel

Boiler with heatpump / Värmepumpsberedare

ASSEMBLY INSTRUCTIONS SCALE - SYSTEM

ASSEMBLY INSTRUCTIONS SCALE SQUARE - STANDARD

Installation Instructions

DE Gebrauchsanleitung / Montageanleitung 2 SV Bruksanvisning / Monteringsanvisning 4. Ecostat 1001 SL

Företagsnamn: Grundfos Skapad av: Magnus Johansson Tel: +46(0) Datum:

EPIC MODELL A. INR guarantees product function if the industry regulations and the installation instruction are followed.

This manual should be saved! EcoFlush Manual

Joki Joki Air. JCD70-xx JAD90-xx. lasiesta.com. Manual. Betriebsanleitung. Manuel. Manual. Manuale. Gebruiksaanwijzing.

Montageanvisning Airway system 1000/1500 Assembly instruction Airway system 1000/1500

SAFETY PRECAUTIONS SPECIFICATIONS

LINC 23. Duschblandare/Shower Mixer. inr.se A

SUZUKI GRAND VITARA 3P CITY 2011»

IMPORTANT! RETAIN FOR FUTURE REFERENCE PLEASE READ CAREFULLY VIKTIGT! BEHÅLL FÖR FRAMTIDA REFERENSLÄS IGENOM INSTRUKTIONSMANUALEN NOGGRANT

Köksblandare 9000E II Pip, spärrbar i 4 lägen Med diskmaskinsavstängning

Floor. Garanti/Warranty. Service, resevdelar/spare-parts Sweden: Tel: +46 (0) Norway: Tel: Finland: Puh:

Instruction Manual. Svenska, English. Power Bank. Model: PRBN

BBT057/ BBC057 BBCD057/ BBT057-NL HOLDEN COLORADO 9/2016+ HOLDEN TRAILBLAZER WD & 4WD Models

Users manual Bruksanvisning Gebrauchanweisung Guide d instructions

Metodprov för kontroll av svetsmutterförband Kontrollbestämmelse Method test for inspection of joints of weld nut Inspection specification

Rev No. Magnetic gripper 3

CANALKLER 250S. Gänga i tum Thread in inch

Kamrör / Ribbed pipe radiator

GOLD SD Med styrenhet/with control unit. Fläkt/ Fan. Utan filter/ Without filter. Fläkt/Fan. Fläkt/ Fan. Med filter/ With filter.

Spjäll m.m. Louvre slats etc. Byggnadssystem i aluminium Building Systems in Aluminium

Z-LYFTEN PRODUKTION AB MONTERINGSANVISNING INSTALLATION INSTRUCTIONS

Z-LYFTEN PRODUKTION AB MONTERINGSANVISNING INSTALLATION INSTRUCTIONS

A TASTE OF THE FUTURE

Slangupprullare Hose reels

BBT042/ BBC042/ BBCD042 NISSAN NAVARA D40 V STX & PATHFINDER R WD & 4WD Models

Dokumentnamn Order and safety regulations for Hässleholms Kretsloppscenter. Godkänd/ansvarig Gunilla Holmberg. Kretsloppscenter

FORTA M315. Installation. 218 mm.

Transkript:

EN Table of contents 1 Instructions for use / assembly instructions 2 Troubleshooting 3 Assembly 6-9 Adjustment 10 Safety Function 11 Operation 12-13 Maintenance 14-15 Cleaning 16-18 Dimensions 19 Flow diagram 19 Spare parts 20 Contact information 20 SV Innehållsförtäckning 1 Bruksanvisning / Monteringsanvisning 4 Felsökning 5 Montering 6-9 Inställning av maxtemperatur 10 Safety Function 11 Hantering 12-13 Skötsel 14-15 Rengöring 16-18 Måttskiss 19 Flödesschema 19 Reservdelar 20 Kontaktinformation 20 MySelect S 240 Showerpipe 26765400 1 (20)

English Safety Notes Gloves should be worn during installation to prevent crushing and cutting injuries. The arm of the shower head is intended only to hold the shower head. Do not load it down with other objects! Children as well as adults with physical, mental and/ or sensoric impairments must not use this shower system without proper supervision. Persons under the influence of alcohol or drugs are prohibited from using this shower system. Do not allow the streams of the shower touch sensitive body parts (such as your eyes). An adequate distance must be kept between the shower and you. The product may not be used as a holding handle. A separate handle must be installed. The shower system may only be used for bathing, hygienic and body cleaning purposes. The hot and cold supplies must be of equal pressures. Installation Instructions Prior to installation, inspect the product for transport damages. After it has been installed, no transport or surface damage will be honoured. The product is not designed to be used with steam baths! The pipes and the fixture must be installed, flushed and tested as per the applicable standards. The plumbing codes applicable in the respective countries must be oberserved. The installation dimensions stated in these installation instructions are ideal for people of approximately 1800 mm in body height. The dimensions can be altered if required. In this case, pay attention to the fact that a change of installation height will also change the minimum height, and that the altered mounting dimensions must be taken into consideration. Where the contractor mounts the product, he should ensure that the entire area of the wall to which the mounting plate is to be fitted, is flat (no projecting joints or tiles sticking out), that the structure of the wall is suitable for the installation of the product and has no weak points. The enclosed screws and dowels are only suitable for concrete. For another wall constructions the manufacturer's indications of the dowel manufacturer have to be taken into account. The filter insert must be use to protect the shower against incoming dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the shower; such caused faults voids all liability and guarantee claims. If required, the bottom part of the pipe between the fixture and the shower head can be shortened with a fine-toothed saw. The shower arm of the head shower can only be adjusted to the desired angle once during installation. Subsequent adjustment during showering is not possible. Assembly (see page 6) Pressure and permeability test The connections of the thermostatic mixer should be tested regular after installation. Technical Data Operating pressure: max. 1 MPa Recommended operating pressure: 0,15-0,5 MPa Test pressure: 1,6 MPa (1 MPa = 10 bar = 147 PSI) Hot water temperature: max. 80 C Recommended hot water temp.: 65 C Centre distance: 160 mm Connections M 26x1,5: cold right - hot left Thermal disinfection: max. 70 C / 4 min Safety against backflow The product is exclusively designed for drinking water! 2 (20)

English Symbol description Do not use silicone containing acetic acid! Adjustment (see page 10) After the installation, the output temperature of the fitting must be tested and set to the temperate desired by the customer. Correction is necessary if the temperature measured at the take off point differs from the temperature set on the scale. Safety Function (see page 11) The desired maximum temperature for example max. 42º C can be pre-set thanks to the safety function. Operation (see page 12) To empty the overhead shower after use, hold it in a slightly inclined position. Cleaning (see page 16 and enclosed brochure) Maintenance (see page 14) The check valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year). To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold. Dimensions (see page 19) Flow diagram (see page 19) overhead shower Hand shower Spare parts (see page 20) Special accessories (order as an extra) #95163000 tile-matching-disk chrome plated Troubleshooting Fault Cause Remedy Insufficient water --Supply pressure inadequate --Check water pressure (If a pump has been installed check to see if the pump is working). --Filters are dirty (97367000) --Cleaning the filter in the water connection and at the thermostat cartridge (97367000) --Shower filter seal dirty --Clean filter seal between shower and hose Crossflow, hot water being forced into cold water pipe, or vice versa, --Backflow preventers dirty or leaking --Clean backflow preventers, exchange if necessary when mixer is closed Spout temperature does not correspond --Thermostat has not been adjusted --Adjust thermostat with temperature set --Hot water temperature too low --Increase hot water temperature to 42 ºC to 65 ºC Temperature regulation not possible --thermo cartridge calcified --Exchange thermo cartridge Instantaneous heater didn't work with --Filters are dirty --Clean the filter / exchange filter thermostat --check valve hasn't moved back --Exchange check valves Assembly see page 6 3 (20)

Svenska Säkerhetsanvisningar Handskar ska bäras under monteringsarbetet så att man kan undvika kläm- och skärskadorgen werden. Armen som håller huvudduschen är bara konstruerad för detta; den får inte belastas med andra föremål! Barn samt vuxna med fysiska, psykiska eller sensoriska funktionshinder får inte använda duschsystemet ensamma. Personer som är påverkade av alkohol- eller droger får inte använda duschsystemet. Undvik att rikta duschstrålarna mot känsliga kroppsdelar (t. ex. ögonen. Det måste finnas ett tillräckligt stort avstånd mellan duschen och kroppen. Produkten får inte användas som handtag. Ett separat handtag måste monteras. Duschsystemet får bara användas till kroppshygien med bad och dusch. Stora tryckskillnader mellan anslutningarna för varmt och kallt vatten måste utjämnas. Monteringsanvisningar Det måste undersökas om produkten har transportskador innan den monteras. Efter monteringen accepteras inga transport- eller ytskiktskador. Produkten är inte avsedd att användas tillsammans med ett ångbad! Ledningarna och blandaren måste monteras, spolas igenom och kontrolleras enligt de gällande normerna. De installationsriktlinjer som gäller i länderna ska följas. De monteringsmått som anges i monteringsanvisningen passar 1,80 m långa personer och måste eventuellt anpassas. Det är då viktigt att tänka på att den minsta höjden ändras när monteringshöjden blir en annan och att hänsyn måste tas till de ändrade anslutningsmåtten. När kvalificerad fackpersonal monterar produkten är det viktigt att tänka på att monteringsytan är plan i alla delar av arbetsytan (inga fogar som sticker ut eller klinkerförskjutningar), att väggkonstruktionen passar till montering av produkten samt att den inte har svaga punkter. Medföljande skruvar och plugg är endast avsedda för betong. Vid andra väggkonstruktioner skall anvisningarna från pluggtillverkaren beaktas. Silpackningen som följer med duschen måste monteras för att undvika att smuts från ledningsnätet tränger in. Smuts som spolas in kan påverka funktionerna och/eller leda till skador på funktionsdelar i duschen. Hansgrohe frånsäger sig allt ansvar för skador som kan härledas till detta. Om det behövs kan röret mellan blandare och huvuddusch kortas i den nedre delen med en fintandad såg. Huvudduschens duschrör kan bara ställas in i den önskade vinkeln en gång under installationen. En senare justering medan duschen används är inte möjlig. Montering (se sidan 6) Tryck och täthetsprov Termostatblandarens anslutningar skall täthetskontrolerasefter installationen. Tekniska data Driftstryck: max. 1 MPa Rek. driftstryck: 0,15-0,5 MPa Tryck vid provtryckning: 1,6 MPa (1 MPa = 10 bar = 147 PSI) Varmvattentemperatur: max. 80 C Rek. varmvattentemp.: 65 C Anslutningsmått: 160 mm Anslutningar M 26x1,5: kallt höger varmt vänster Termisk desinfektion: max. 70 C / 4 min Självspärr mot återflöde Produkten är enbart avsedd för dricksvatten! 4 (20)

Svenska Symbolförklaring Använd inte silikon som innehåller ättiksyra! Inställning av maxtemperatur (se sidan 10) Efter monteringen måste blandarens uttemperatur kontrolleras och ställas in på den temperatur som kunden vill ha. En korrigering krävs när den uppmätta temperaturen vid tappstället avviker från den temperatur som är inställd på termostaten. Safety Function (se sidan 11) Med hjälp av Safety Function kan du ställa in den önskade maximaltemperaturen till exempelvis 42ºC och så förhindra skållningsrisk för barn. Hantering (se sidan 12) Ställ huvudduschen lätt lutande efter användningen för att tömma den. Rengöring (se sidan 16 och medföljande broschyr) Skötsel (se sidan 14) Backventilers funktion måste kontrolleras regelbundet enligt nationella eller regionala bestämmelser (DIN 1988 en gång per år) i enlighet med DIN EN 1717. För att garantera att termostaten ej kalkar igen, ska den regelbundet, en gång per vecka, konditioneras. Det sker genom att man några gånger snabbt slås om temperaturen från hett till kallt och tillbaka. Måtten (se sidan 19) Flödesschema (se sidan 19) Huvuddusch Handdusch Reservdelar (se sidan 20) Specialtillbehör (medföljer ej leveransen) #95163000 Kakelutjämningsbricka krom Felsökning Störning Orsak Åtgärd För lite vatten --Vattentrycket är för lågt --Kontrollera ledningstryck --Smutsfiltren är igensmutsade (97367000) --Rengör smutsfilter i anslutningarna och på styrenheten (97367000) --Silfiltret i duschen smutsigt --Rengör silfiltret mellan slangen och termostaten Korsflöde varmt vatten pressas vid avstängd ermostat in i kallvatten- --Backventil är igensmutsad eller otät --Rengör backventil, byt ut om nödvändigt inloppet, och vice versa Den faktiska vatten- temperaturen --Termostaten ställdes inte in --Justera termostaten stämmer Inte överens med den Inställda --Varmvattentemperaturen är för låg --Höj varmvattentemperaturen til mellan 42ºC och 65ºC Temperaturen kan ej ställas in --Termosensorn är igenkalkad --Byt termosensorn Varmvattenberedare slår ej på vid --Smutsfiltren är igensmutsade --Rengör / byt smutsfilter användning av termostaten --Backventil är defekt --Byt backventil Montering se sidan 6 5 (20)

Montage 1 2 2,5 mm 3 4 2,5 mm 5 The nuts of the installation plate must be tightened to the manufacturer's instructions. Muttrarna dras åt enligt monteringsanvisningen från leverantören av blandarfäste. 23 mm 6 (20)

Montage 6 675-875 mm 7 (20)

Montage 7 50 mm Tätskikt Kakellim Kakel Ø 6 mm Betong Silicone Ø 6 mm 3. Silicone 4. Trä Tätskikt Kakellim Kakel Ø 6 mm When installing on a stud wall, the wall must always be strengthened. All screws must be fixed to solid structures, such as concrete, studs or special structural components. Screws must not be fixed to flooring or wall sheets alone. Requirements for sealing apply in wet zones 1 and Sealing materials must be fixed to the underlying layer and must be waterproof, mould-resistant and age-resistant. Silicone Vid montering på regelvägg måste väggen alltid förstärkas. Alla skruvinfästningar skall ske i massiv konstruktion, t.ex betong, i reglar eller särskild konstruktionsdetalj. Skruvinfästning får inte göras enbart i golv-, eller väggskiva. Krav på tätning gäller både i våtzon 1 och Material för tätning ska fästa mot underlaget och vara vattenbeständigt, mögelresistent och åldersbeständigt. 8a 8b 95163000 8 (20)

Montage 9 10 10 47 62 20 Nr. Ar ma Gr turen ea fe se tt 11 12 SW 17 mm SW 6 mm SW 2 mm 13 97708000 9 (20)

Justierung 1 2 3 4 10 (20)

Safety Function 1 2 3. 3mm 3 4 for example 42 C till exempel 42 C! 5 6 3mm 2 Nm 3. 11 (20)

Bedienung öffnen / öppna öffnen / öppna schließen / stänga kalt / kallt warm / varmt 12 (20)

Bedienung MySelect S Multi 26636400 IntenseRain Massage SoftRain 1 2a 2b 13 (20)

Wartung 1 2 3. SW 6 mm 3 4. 4 5 SW 6 mm 3. SW 2,5 mm 14 (20)

6 7 6 mm 3. 2,5 mm 8 9 5. 4. 23 mm 3. SW 6 mm 15 (20)

1 2 SW 17 mm SW 2 mm 3 4 5 6 SW 17 mm SW 2 mm > 1 min 16 (20)

1 2 SW 5 mm 3 4 SW 5 mm 17 (20)

1 2 > 1 min 3 1 2 18 (20)

Maße Maße MySelect S 240 Showerpipe 26765400 min.40 468 357 Ø41 7 Ø 24 0 2230 2330 2130 2291 2191 160 305 Ø 38 1100 2091 1091 750-850 M 26x1,5 Ø22 41 57 84 1200 1003 2103 2203 2003 8 0 8 0 1000 Durchflussdiagramm MySelect S 240 Showerpipe 26765400 MPa 0,50 0,45 0,40 0,35 0,30 0,25 0,20 0,15 0,10 0,05 0,00 5,0 4,5 4,0 3,5 3,0 2,5 2,0 1,5 1,0 0,5 0,0 Q = l/min 0 3 6 9 12 15 18 21 24 27 30 Q = l/sec 0 0,1 0,2 0,3 0,4 0,5 bar 1 2 19 (20)

Serviceteile MySelect S 240 Showerpipe 26765400 98942000 95163000 95365000 97767000 97958000 97331000 94246000 97536000 97552000 97606000 92366000 96179000 98855000 98419000 (7x2) 95794000 SW 5 mm 92520000 92444000 26636400 95835000 98213000 (9x1) 97367000 95843000 96737000 98913000 98131000 (15x2,5) 98137000 (17x1,5) 98283000 98390000 (26x1,5) 95927000 95836000 98382000 (12x2,25) 97708000 95843000 98913000 95836000 98129000 (14x2) 98058000 98282000 28276000 95839000 98390000 (26x1,5) 20 (20) Hansgrohe AB Svangatn 2B 416 68 Göteborg Tele: +46(0)31-216600 Fax: +46(0)31-190103 E-post: info@hansgrohe.se Internet: www.hansgrohe.se 11/2015 9.01228.01