T/BAS-SDX L T/BAS LKA L

Relevanta dokument
T/BAS-SDX L T/BAS LKA L

T-DC/DC12V1A L T-DC/DC12V1A L

10UT. 19R Fusepanel XM XL XXL 19 SVENSKA POWER SUPPLIES - MADE IN SWEDEN

BS-Large 24 V. Rackmonterad batterihylla med automatsäkring för batterier 2 x 75 Ah till 2 x 150 Ah. Tillbehör till:

BS-Medium 24V. Rackmonterad batterihylla med automatsäkring för batterier 2 x 45 Ah. Tillbehör till: POWER SUPPLIES - MADE IN SWEDEN

RACK EN54-COVER. Obligatoriskt tillval för installation av RACK i anläggningar som är EN 54-4 eller SBF 110:8 godkända.

Sling X POWER SUPPLIES - MADE IN SWEDEN SVENSKA

Sling X-B3 POWER SUPPLIES - MADE IN SWEDEN SVENSKA

10UT. 19R Fusepanel XM XL XXL 19 POWER SUPPLIES - MADE IN SWEDEN SVENSKA. 10UT A5_V1.indd :54:59

NEO XL NEO XL NEO XL SVENSKA POWER SUPPLIES - MADE IN SWEDEN

T/BAS-JFI POWER SUPPLIES - MADE IN SWEDEN SVENSKA

BAS XM BAS XM BAS XM BAS XM BAS XM SVENSKA. BAS XM v1.indd :31:29 POWER SUPPLIES - MADE IN SWEDEN

T-4UT D-SUB / T-4UT T-4UT D-SUB / T-4UT

ECO XS ECO XS ECO XS ECO XS SVENSKA. ECO XS v01.indd :16:35 POWER SUPPLIES - MADE IN SWEDEN

BAS XM BAS XM BAS XM BAS XM SVENSKA. BAS XM v1.indd :36:12 POWER SUPPLIES - MADE IN SWEDEN

ECO XXS2 ECO XXS2 ECO XXS2. ECO XXS2 / 3,2 Ah ECO XXS2 / 7,2 Ah ECO XXS2 / 7,2 Ah POWER SUPPLIES - MADE IN SWEDEN

ECO MINI ECO MINI ECO MINI SVENSKA POWER SUPPLIES - MADE IN SWEDEN

T-DC/JFI 2,5A D-Sub L

BAS XL BAS XL BAS XL-HS SVENSKA POWER SUPPLIES - MADE IN SWEDEN

ECO XS ECO XS ECO XS ECO XS SVENSKA POWER SUPPLIES - MADE IN SWEDEN

BAS 19 BAS BAS HS SVENSKA. BAS19 v1.indd :11:31 POWER SUPPLIES - MADE IN SWEDEN

ECO C3. ECO C3/7Ah ECO C3/2,3Ah ECO C3/2,3Ah. Bruksanvisning i original V 0.1

ECO C4 ECO C4 ECO C4 ECO C4 ECO C4 ECO C4. Bruksanvisning i original V 0.1

NEO XM NEO XM NEO XM NEO XM SVENSKA. NEO XM v01.indd :38:28 POWER SUPPLIES - MADE IN SWEDEN

ECO C3. ECO C3/7Ah ECO C3/2,3Ah ECO C3/2,3Ah. V Bruksanvisning i original. POWER SUPPLIES - MADE IN SWEDEN

PoE. PoE XS2 /4p PoE XS2 /4p PoE XS2 /4p SVENSKA. PoE XS2_4p.indd :22:28

ECO mini ECO MINI ECO MINI POWER SUPPLIES - MADE IN SWEDEN SVENSKA

NEO 2 NEO FLX NEO FLX NEO FLX NEO² FLX NEO² FLX POWER SUPPLIES - MADE IN SWEDEN

NEO 2 NEO XS2 NEO XS2 NEO XS2 NEO XS2 NEO XS2 POWER SUPPLIES - MADE IN SWEDEN

T/BAS Sling X Larmdonsövervakningsmodul

BAS 10A-serien BAS XM BAS XL BAS 19

Läs detta före användning

NEO 2 - PoE. PoE FLX/16p POWER SUPPLIES - MADE IN SWEDEN. SVENSKA Version 1.0.0

BAS Serien. Produktkatalog. Batteribackuper

SSF-TEQ-XM /S3 SSF-BB-XM /S3

Manual / Handhavande BT 40-serien BT40 BT40L BT40BL. SSF typ A - grade 3 - miljöklass 1 SSF type A - grade 3 - environmental class 1

SSF-TEQ-XM SSF-BB-XM

SSF-TEQ-XL /S3 SSF-TEQ-XXL /S3

Läs detta före användning

SSF-TEQ-XL SSF-TEQ-XXL

EN54-BB-XM SSF-BB-XM BB-24V-XM

ECO XS-serien ECO XXS-serien

NEO 2 NEO XL NEO XL NEO XXL NEO XXL NEO XXL NEO XL NEO XL

SSF-TEQ SSF-TEQ-XL /S3 SSF-TEQ-XLL /S3 POWER SUPPLIES - MADE IN SWEDEN. SVENSKA Utgåva

SSF-TEQ SSF-TEQ-XM /S3 SSF-BB-XM /S3 POWER SUPPLIES - MADE IN SWEDEN. SVENSKA Utgåva SSF-TEQ-XM.indb :52:15

BATTERIBOX 24V-XS2 POWER SUPPLIES - MADE IN SWEDEN SVENSKA

SSF-TEQ-XL /S3 SSF-TEQ-XXL /S3

RACK RACK HE RACK HE RACK HE RACK HE. SVENSKA - Version POWER SUPPLIES - MADE IN SWEDEN

Läs detta före användning

RACK RACK HE RACK HE RACK HE RACK HE. SVENSKA - Version RACK_1HE_2HE_publicerad.indd :26:33

EN54 EN XM EN XM SVENSKA. EN54 XM v01.indd :51:59 POWER SUPPLIES - MADE IN SWEDEN

EN54 EN XM EN XM SVENSKA POWER SUPPLIES - MADE IN SWEDEN

RLS500/600 RÖKLUCKESTYRNING

BATTERIBOX 24V-XM. Tillbehör till EN XM EN XM SSF-TEQ-XM BAS XM BAS XM BAS XM POWER SUPPLIES - MADE IN SWEDEN

TEQ FLX. TEQ FLX/Sentrion TEQ FLX/ Sentrion TEQ FLX/ Sentrion TEQ FLX/ Sentrion POWER SUPPLIES - MADE IN SWEDEN

RLS RÖKLUCKESTYRNING

RLS RÖKLUCKESTYRNING

SSF typ A - grade 3 - miljöklass 1 SSF type A - grade 3 - environmental class 1

BAS STRÖMFÖRSÖRJNING Slingövervakningsmodul-EXT/Kretskort

Manual / Handhavande BT8A-COM BT16-COM BT32-COM. Norsk utgave:

SIN XM SIN 600W-XM SIN 1100W-XM SIN 1500W-XM POWER SUPPLIES - MADE IN SWEDEN SVENSKA

NEO NEO XL NEO XL NEO XXL NEO XXL NEO XXL NEO XL POWER SUPPLIES - MADE IN SWEDEN V. 1.

EN54-19S EN S EN S EN S SVENSKA POWER SUPPLIES - MADE IN SWEDEN

NEO NEO FLX NEO FLX NEO FLX NEO FLX NEO FLX POWER SUPPLIES - MADE IN SWEDEN. SVENSKA - Version 1.1.

Produktdokumentation UPS

NEO NEO XS NEO XS NEO XS NEO XS NEO XS NEO XM NEO XM NEO XM POWER SUPPLIES - MADE IN SWEDEN

ELDACO AB. Manual. Strömförsörjningsaggregat PP 12/8 och PP 24/6. Presentation 2 Inkoppling 3 Larmer 4 Tekniska data 5-6

Manual Nödljusaggregat MAPOWER

Manual Likriktare SM3000

Manual Likriktare SM3000

Produktdokumentation UPS

UDR-Plus Dörrlarm. axema Sida 1. Art. nr / E UDR Plus är ett kompakt dörrlarm, för att övervaka alla typer av dörrar

Manual / Handhavande EN S EN S EN S

Manual Likriktare SM2000

Manuell bryter åpen / Open switch / Schalter auf. Manuell bryter stengt / Closed switch / Schalter zu. Summa alarm / Summation Alarm / Summe Alarm

Bat teribackuper UP S

UDR-Plus Dörrlarm. axema Sida 1. Art. nr / E UDR Plus är ett kompakt dörrlarm, för att övervaka alla typer av dörrar

Manual Nödljusaggregat MAPOWER

LAN 53-2 och LAN 54-2 manual

UDR Bakdörrslarm. Ljud och Blixtljus ((utgått)

Certified Series. SSF typ A - grade 3 - miljöklass 1 SSF type A - grade 3 - environmental class 1

UDR-plus Universellt dörrlarm

Accenta nödljuscentraler med sinusspänning ut.

Konstantspänningslikriktare.

Rekonditionering. EPIsafe och EPIsafe 2. Art.nr och Programversion x.x.x eller senare. Rev PB SE

Övervakningssystem EKO-KE1

Swing-Gate. ECO B/S Installation av Swing Gate

Manual Likriktare SM2100

Produktfolder. - Säker energi med innovativ reservkraft. Vi förbehåller oss rätten till eventuella ändringar.

Manual Uppdaterad UDR-plus. Axema Access Control AB Box Stockholm, Sweden

Installationsmanual Multiläsare 2000 användare 12V DC Revidering 1.00

Rekonditionering. EPIsafe 2 GSM. Art.nr Programversion x.x.x eller senare. Rev PA1 SE

UDR-plus Universellt dörrlarm

Manual / Handhavande Certifierade serien BT80L++ SSF typ A - grade 4 - miljöklass 1 SSF type A - grade 4 - environmental class 1

Solcellsregulator. Användarmanual. 1. Egenskaper:

Konstantspänningslikriktare med inbyggda batterier.

Ontech Relay 9010 Bruksanvisning a

Elrond Komponent AB Sida 2(8) NPW

Övervakning M-serien

BRUKSANVISNING DAAB UTGÅNGSKORT DB410

Transkript:

T/BAS-SDX L T/BAS LKA L POWER SUPPLIES - MADE IN SWEDEN SVENSKA

Milleteknik Milleteknik har sedan 1993 levererat säker energi med innovativ reservkraft. Vi är en svensk utvecklare och tillverkare av batteribackuper för skydds & säkerhetsbranschen, industrin och andra aktörer som kräver högsta energitillgänglighet i sina säkerhetssystem. Vi garanterar reservkraften i viktiga samhällsfunktioner såsom brandlarm, passersystem och utrymningslarm. SÄKERHET - LÄS DETTA FÖRST! Enheten skall monteras av behörig person. Batteribackupenheten kan vara spänningssatt under installation montering av utbyggnadskort dock bör försiktighet beaktas. Det är installatörens ansvar att systemet är lämpad för tänkt bruk. Dokument som medföljer systemet skall förvaras i det eller i dess omedelbara närhet. Alla uppgifter med reservation för ändringar. 2

T/BAS-SDX L är ett utbyggnadskort för BAS-serien. Kortet ger fler övervakningslarm. T/BAS- LKA L saknar, (via potentialfri reläväxling), larm för åldrat batteri. Ubyggnadskort kan monteras i alla system i BAS serien. Produktbeskrivning För ökad läsbarhet benämns: T/BAS-SDX L och T/BAS LKA som SDX. Benämning SDX i kombination med andra tillvalskort 10UT DCDC 1A DCDC 5A SPD Sling X JFI BAS XM Ja Ja Ja Ja Ja Ja BAS 19 Ja Ja Ja Ja Ja Ja BAS XL Ja Ja Ja Ja Ja Ja 3

Settings Test load J7 SW6 D1 LED-indication LED-Status indication terminal J2 J4 J3 J8 NO CO NC NO CO NC NO CO NC NO CO NC Mains Failure Low battery SDSS Low output voltage Alarm Alarm Alarm Alarm J7 Testlast, inkoppling effektmotstånd. SW6 Dip-switch 1-8 D1 Indikeringsdiod. EXT LED Anslutning till extern indikeringsdiod. 4 J2 J4 J3 J8 Larm: Tidsinställbart Nätavbrottslarm (inklusive utlöst fassäkring), NO/CO/NC. Larm: Låg batterispänning vid viss inställd nivå i batteridrift / Utlöst lastsäkring / Batterifel, NO/CO/NC. Summalarm, över-/underhållspänning, åldrat/frånkopplat batteri, NO/CO/NC. Larm: Låg utspänning (larm ges när spänningen sjunker under 24V), NO/CO/NC.

Larminställningar görs enklast innan kortet monteras. Utförs ändringar i larminställningar Dip-Switch kan ställas i ON- eller OFF-läge. Larminställingar Dip-switch efter det att kortet är monterat och driftsatt skall Dip-switch 8 slås på och av för att initiera de nya larminställningarna, se sida 14. OFF ON Larminställning av kvarvarande batterikapacitet Larm vid 75% kapacitet kvar, (fabriksinställning). Dip 1 Dip 2 Dip 3 DIP-switch SW3 ON OFF OFF Larm vid 50% kapacitet kvar OFF ON OFF Larm vid 25% kapacitet kvar OFF OFF ON Larminställning av fördröjt nätbortfallslarm Larm direkt vid nätbortfall, (fabriksinställning). OFF OFF Dip 4 Dip 5 DIP-switch SW3 Larm fördröjt 3 min. ON OFF Larm fördröjt 15 min. OFF ON Larm fördröjt 1 tim. ON ON 5

Montering SDX på BAS kortet Innan montering: Kontrollera att spänningen (12 V eller 24 V) på SDX är samma som för BAS-enheten. Vilken spänning har SDX-kortet? 12 V eller 24 V. På kartongen finns en CE-etikett. Volttalet som står på CE-Etiektten skall vara samma som BAS-enhetens (CE-etikett). Spännningen står även på reläerna, se bild till höger. SDX kan bara sitta på ett sätt på BAS-kortet. Tryck ner SDX kortet så att det sitter fast ordentligt. Båda kontakterna skall tryckas på plats. Skall fler kort monteras på BASkortet? Montera då SDX sist. 6

T/BAS-SDX L & T/BAS LKA L Inkoppling Effektmotstånd Effektmotstånd kopplas in på J7. Test load S J7 D Flytta kabel för indikeringsdiod Flytta kabel som är ansluten på J25 på det nedre BAS-kort till EXT LED på SDX. Efter flytt av kabel visar panel på skåpdörr nu de utökade larmen, se sida 8. J2 J4 NO CO NC NO CO NC Mains Failure Low battery Alarm Alarm 7

Panelbeskrivning Vid larm blinkar indikeringsdioden rött. Antalet blink visar vilket larm det gäller. 1 Blink: Nätbortfall / Mains Failure 2 Blink: Fördröjd nätavbrottslarm Delayed Mains failure alarm 3 Blink: Underspänning / Under voltage P OWER SUPPLY AC/DC B ATTERY BACKUP 4 Blink: Överspänning / Overvoltage 5 Blink: Åldrat batteri / Aged batteries (Ej T/BAS LKA L) 6 Blink: Låg batterispänning eller Batterifel, bortkopplade batterier / Low battery voltage-disconnected batteries Designed & Produced by BAS SERIES O p t i o n a l M o n i t o r i n g S TANDARD ALARMS NORMAL OPERATION DELAYED MAINS FAILURE ALARM LOW BATTERY ALARM CHARGER FAULT-UNDER VOLTAGE DEEP DISCHARGE PROTECTION T/BAS XST NORMAL OPERATION OVER VOLTAGE LEAKAGE TO PE LOW BATTERY ALARM BLOWN FUSE DISCONNECTED BATTERIES CHARGER FAULT-UNDER VOLTAGE DEEP DISCHARGE PROTECTION DELAYED MAINS FAILURE ALARM- ONLY TERMINAL BLOCK T/BAS LKA/ SDX NORMAL OPERATION MAINS FAILURE DELAYED MAINS FAILURE ALARM UNDER VOLTAGE OVER VOLTAGE AGED BATTERIES (ONLY T/BAS SDX) LOW BATTERY VOLTAGE/DISCONNECTED BATTERIES DEEP DISCHARGE PROTECTION/BLOWN FUSE LOW SYSTEM VOLTAGE- ONLY TERMINAL BLOCK E NERGY EFFICIENT POWER SUPPLY >80% EFFICIENCY WWW. MILLETEKNIK. SE Standardlarm (utan monterat tillvalskort). Larm med tillvalskort: T/BAS XST Larm med tillvalskort: T/BAS LKS/SDX SDX i BAS XM 8

SDX i BAS 19 SDX i BAS XL 9

Driftsättning Se manual för BAS för driftsättning utan tillvalskort. Ställ larmnivå innan driftsättning, se sida 5. Kontrollera att Dip-switch 8 är ställd till OFF (Larmövervakning aktiverad). Driftsättning med inkopplad nätspänning. 1. Montera SDX-kortet, se sida 6. 2. Anslut nätspänning. 3. Systemet gör systemtest, se sida 11, när den är klar lyser indikeringsdiod, D1, med ett fast grönt sken. Systemet är i normaldrift. 4. Koppla från nätspänning för att kontrollera att systemet fungerar normalt i batteridrift. 5. Anslut nätspänningen för att återgå till normaldrift. Systemet är nu driftsatt. Driftsättning utan inkopplad nätspänning. Saknas nätspänning kan systemet testas i batteridrift. 1. Montera SDX-kortet, se sida 6. 2. Anslut batterier, se BAS-manulen. 3. Tryck ned tryckknapp, SW2 på BAS-kortet och håll intryckt tills indikeringsdioden på BAS-kortet lyser rött. 4. Systemet genomför ett systemtest, se sida 11. Larm för nätavbrott ges. 5. Systemet är nu driftsatt utan nätspänning. TIPS! Om nätspänning saknas efter test av driftsättning: BAS XM: Ta bort batterisäkring för att stänga av systemet. BAS 19 och BAS XL : Slå från automatsäkringen till batterier för att stänga av systemet. 10

Systemtest Varje gång systemet startas körs en systemtest. Systemtestet är automatiskt och kontrollerar förutom larm även batterier. Detta händer vid systemtest: Indikeringsdioden (D1) blinkar samtidigt som larm ges på alla utgångar. Larmrelä testas och klickljud hörs, Efter test ställer sig varje relä i normalläge (CO/NC, slutning). När testet är klart lyser indikeringsdioden (D1) med ett fast grönt sken. Om fel upptäcks kommer larm att ges när test är avslutat. Automatisk batteritest Var sjunde dag gör systemet ett automatiskt batteritest. (Vid nätavbrott startar sjudagars cykeln om och automatiskt batteritest görs alltså vid sju dagars obruten nätspänning). En systemtest påverkar inte systemets normaldrift. Nätaggregatet ger konstant spänning till last under hela systemtestet. Manuellt systemtest Det går att göra ett manuellt systemtest utan att starta om systemet. Systemtesten påverkar inte systemets normaldrift. Nätaggregatet ger konstant spänning till last utan hela systemtestet. Observera att systemtestet kan ge larm om batterierna inte är fullt laddade. Gör såhär: Steg Dip-Switch Sekvens 1 Notera position på Dip-switch 1, 2 och 3. 2 Dip-switch 1: OFF 3 Dip-switch 2: OFF 4 Dip-switch 3: OFF 5 Dip-switch 8: OFF-ON-OFF 6 Vänta ca 30 sekunder test är klart när indikeringsdioden lyser med ett fast grönt sken. 7 Återställ position på Dip-switch 1, 2 och 3 8 Initiera larminställningar med Dip-switch 8: OFF-ON-OFF 11

Manuellt systemtest fortsättning Systemtestet består av: Larm- och batteritest under ca 15 sekunder. Under test blinkar indikeringsdioden i olika sekvenser. Efter avslutat systemtest återställ Dip-switchar till ursprunglig läge. Initiera åter larminställningar för kvarvarande batterikapacietet (se sida 5) genom att Dip-switch 8 skall ställas från OFF till ON och tillbaka till OFF. Systemtesten är nu avslutad. Indikeringsdioden skall lysa med ett fast grönt sken. Batteribyte Se även manual för BAS vid batteribyte. Batteribyte påverkar inte spänning ut till last. Bryt dock om det är möjligt nätspänningen, för din egen säkerhet. Gör så här: Sätt Dip-switch 8 till ON. Byt batterier, se manual för BAS. Koppla till nätspänning (om den varit frånkopplad). Sätt DIP-switch 8 OFF Systemet startar upp med systemtest, se ovan. (Återställ vid behov larm, se sida 15. ) Indikeringsdioden skall nu lysa med ett fast grönt sken. Normaldrift. NOT: Om man inte återställer larm med Dip-switch 8 kvarstår larm. 12

Test av batterikapacitet med multimeter Samtidigt som systemtest pågår kan man mäta med multimeter: 1. Nätspänning - Multimeter AC över nätaggregatets fas, F, och noll, N, IN (230Vac). 2. Lastsäkringar - Multimeter DC över lastutgång +/- UT (27,3 vid nom. 24V) 3. Laddare (laddspänning) - Multimeter DC över batteripoler +/- (26,7-27,3Vdc per batteripar vid nom. 24V). 4. Batteripolaritet och polspänning - Multimeter DC över batteripoler +/- med nät/laddning frånkopplad (röd kabel till + och svart till -13,65Vdc per batteri vid fullt uppladdade batterier, 10-14V för funktionalitet). 5. Batterikapacitetstest (batteriåldring) i funktion - Multimeter DC över batteripoler +/- (snabbt fallande spänning under ca 5 sek. test). 13

SDX har fyra larmutgångar som larmar tillsammans med indikeringdioder (förutom larm via J8). Larm sker på växlande potentialfri reläkontakt. Slutning in normalläge: CO/NC. Slutning i larmläge: NO/CO. T/BAS LKA/ SDX NORMAL OPERATION MAINS FAILURE DELAYED MAINS FAILURE ALARM UNDER VOLTAGE OVER VOLTAGE AGED BATTERIES (ONLY T/BAS SDX) LOW BATTERY VOLTAGE/DISCONNECTED BATTERIES DEEP DISCHARGE PROTECTION/BLOWN FUSE LOW SYSTEM VOLTAGE- ONLY TERMINAL BLOCK & Nätavbrottslarm - J2 Nätavbrottslarm ges på kretskortsplint J2. Om nätspänningen uteblir under längre tid ges larm. Tid för när larm ges ställs in via DIP-switch 4 och 5 (se sida 5). Larmet är ett äkta nätlarm på primärspänningssidan, som känner av nätavbrott eller utlöst fassäkring. Standardinställning för nätavbrottsslarmet från fabrik är att larm ges direkt vid nätavbrott. Larmet återställs automatiskt när nätspänningen återkommer. Larmbeskrivning J2 J4 J3 J8 NO CO NC NO CO NC NO CO NC NO CO NC Summalarm - J3 Underspänning Överspänning Åldrat batteri Larm för underspänning/ laddarfel, överspänning och åldrat batteri ges kretskortsplint på J3. Underspänningslarm ges när ges när systemspänningen sjunker under 25,5V (och batterier är inkopplade). Larmet återställs automatiskt när systemspänningen når 26,4V. Överspänningslarm ges när systemspänningen överstiger 27,9V och återställs automatiskt när systemspänningen sjunker till 27,7V. Överspänningslarm kopplar bort batterierna. Detta för att skydda dem. Underspänning påverkar batteriernas livslängd och bör åtgärdas så fort som möjligt. Larm för åldrat batteri ges när batteritestet, som genomförs i gång var sjunde dag i nätdrift, understiger 23,5V. Vid larm för åldrat batteri bör batterierna bytas ut. 14

Larmbeskrivning fortsättning Lågt batterispänning / batterifel - J4 Gäller ej T/BAS LKA L. Larm för låg batterispänning/batterikapacitet/batterifel ges på J4. Larm för låg batterispänning/low battery voltage ges när batterispänningen sjunker under angiven gräns se sida, 5. Larm för batterifel/disconnected batteries ges när batterierna kopplas ifrån eller när batterisäkringen på kortet / mellan batterierna är trasig. Låg utspänning - J8 Larm för låg utspänning ges på J8. Larmet ges när spänningen ut sjunker under 24V och återställs automatiskt när spänningen överstiger 24,4V. Detta larm ges ej på indikeringsdiod. Lastsäkringsfel - J1, J2 & J4 Larm för lastsäkringsfel (+) ges genom larm på J2, J3 och J4. Indikeringsdioden släcks då helt. Larmet återställs automatiskt när säkring är bytt. Larmåterställning Ställ DIP-switch 8 på kretskortet till läge ON. Ställ tillbaka DIP-switch 8 till läge OFF. Sekvens Dip-switch 8: OFF-ON-OFF Systemet är nu rensat från larm och en systemtest kör, (se sida 11). Efter systemtest går systemet i normaldrift. 15

Milleteknik har sedan 1993 levererat säker energi med innovativ reservkraft. Vi är en svensk utvecklare och tillverkare av batteribackuper för skydds & säkerhetsbranschen, industrin och andra aktörer som kräver högsta energitillgänglighet i sina säkerhetssystem. Vi garanterar reservkraften i viktiga samhällsfunktioner såsom brandlarm, passersystem och utrymningslarm. Forskning, utveckling och produktion sker i Partille, strax utanför Göteborg. Mer information om oss hittar du på www.milleteknik.se AC Kretskort DC Transistor F N Extra EMC Filter SKYDD Övervakning Last 1 etc. Djupurladdningsskydd Last 2 Transistor Last 3 Effektmotstånd ECO NEO BAS NOVA RACK (1HE/2HE) POE COM ECO serien präglas av enkelhet, hög kvalité till rätt pris, driftsäkerhet och miljövänlighet. Milletekniks batteribackuper är samtliga primärswitchade med mycket hög verkningsgrad; >80%. NEO serien är certifierad enligt elsäkerhetsgodkännande EN 60950-1. Serien erbjuder hög driftsäkerhet, enkelhet och hög verkningsgrad i kombination med flertalet larmfunktioner som standard. BAS Serien erbjuder flexibilitet, hög tillförlitlighet och avancerad teknik till ett rimligt pris. BAS Serien används främst till anläggningar där kraven är högre och där belastningarna kräver större nätaggregat och längre reservdrifttider. Ny certifierad serie. Lanseras 2017. Certifikat: SSF (EN50131-6/SSF1014) / Brand (EN 54-4/SBF 110:7), elsäkerhet (EN 60950-1) och passerkontroll, 60839-11-1. Ny certifierad serie. Lanseras 2017. Certifikat: Brand (EN54-4 / SBF 110:7), elsäkerhet (EN 60950-1). och passerkontroll, 60839-11-1. PoE serien är en serie smarta batteribackuper / likriktare avsedda för system som kräver Power over Ethernet strömförsörjning. Switchen stöder IEEE 802.3af och IEEE 802.3af Power over Ethernetstandard. Enheter anpassade för systemintegratörer. Certifikat: SSF (EN50131-6/SSF1014), elsäkerhet (EN 60950-1) och passerkontroll, 60839-11-1. Milleteknik AB Ögärdesvägen 8 B 433 30 Partille 031-340 02 30 info@milleteknik.se www.milleteknik.se V 1.0-170410