Teknisk rapport SIS-CEN/TR 15641:2007 Publicerad/Published: Utgåva/Edition: 1 Språk/Language: engelska/english ICS: 67.

Relevanta dokument
Information technology Open Document Format for Office Applications (OpenDocument) v1.0 (ISO/IEC 26300:2006, IDT) SWEDISH STANDARDS INSTITUTE

Surfaces for sports areas Determination of vertical deformation. Golvmaterial Sportbeläggningar Bestämning av vertikal deformation

SVENSK STANDARD SS :2010

Byggdokument Angivning av status. Construction documents Indication of status SWEDISH STANDARDS INSTITUTE

Eurokod 3 : Dimensionering av stålkonstruktioner Del 4-1: Silor. Eurocode 3: Design of steel structures Part 4-1: Silos SWEDISH STANDARDS INSTITUTE

Sanitetsarmatur Sanitetsarmatur med elektronisk öppningsoch avstängningsfunktion. Sanitary tapware Electronic opening and closing sanitary tapware

Byggritningar Ritsätt Fästelement. Construction drawings Representation of fasteners SWEDISH STANDARDS INSTITUTE

Eurokod 9 : Dimensionering av aluminiumkonstruktioner Del 1-1: Allmänna regler

Eurokod 7: Dimensionering av geokonstruktioner Del 2: Marktekniska undersökningar

Teknisk rapport SIS-TR 18:2007 Publicerad/Published: Utgåva/Edition: 1 Språk/Language: svenska/swedish ICS: ;

Eurokod 3: Dimensionering av stålkonstruktioner Del 5: Pålar och spont. Eurocode 3: Design of steel structures Part 5: Piling

Eurokod 2: Dimensionering av betongkonstruktioner Del 3: Behållare och avskiljande konstruktioner för vätskor och granulära material

Byggakustik Mätning av rumakustiska parametrar Del 2: Efterklangstid i vanliga rum (ISO :2008/Cor 1:2009)

Bevakningstjänster Terminologi. Security service providers Terminology SWEDISH STANDARDS INSTITUTE

SWEDISH STANDARDS INSTITUTE

Byggdokument Ändringar. Construction documents Revisions SWEDISH STANDARDS INSTITUTE

Maskinsäkerhet Styrsystem Säkerhetsrelaterade delar i styrsystem Del 1: Allmänna konstruktionsprinciper (ISO :2006/Cor 1:2009)

Brottsförebyggande genom stadsplanering och byggnadsutformning Del 1: Terminologi

SVENSK STANDARD SS-EN ISO 9001:2008/AC:2009

SVENSK STANDARD SS-EN ISO /A1:2016

System för fjärrkommunikation med debiteringsmätare Del 6: Local bus. Communication systems for meters and remote reading of meters Part 6: Local bus

Akustik Buller från maskiner och utrustning Regler för utformning av produktspecifika mätstandarder (ISO 12001:1996)

SVENSK STANDARD SS EN 15802:2009

Eurokod 3: Dimensionering av stålkonstruktioner Del 1-3: Kallformade profiler och profilerad plåt

SWEDISH STANDARDS INSTITUTE

Teknisk specifikation SIS-TS 31:2009 Publicerad/Published: Utgåva/Edition: 1 Språk/Language: svenska/swedish ICS: ;

Surface active agents Sulfated ethoxylated alcohols and alkylphenols Determination of content of unsulfated matter (ISO 8799:2009)

Artificial climbing structures Part 3: Safety requirements and test methods for climbing holds SWEDISH STANDARDS INSTITUTE

SVENSK STANDARD SS-EN ISO

Petroleum, petrochemical and natural gas industries Venting of atmospheric and low-pressure storage tanks (ISO 28300:2008/Cor 1:2009)

SVENSK STANDARD SS-EN ISO 19108:2005/AC:2015

Luftkonditioneringsaggregat, vätskekylare och värmepumpar, med elmotordrivna kompressorer, för rumsuppvärmning och -kylning Del 3: Testmetoder

SVENSK STANDARD SS-EN ISO

Akustik Deklaration av verifiering av bulleremissionsvärden från maskiner och utrustning (ISO 4871:1996)

Brottsförebyggande genom stadsplanering och byggnadsutformning Del 1: Terminologi

SVENSK STANDARD SS-EN ISO 7291:2010/A1:2015

Naturgas Bestämning av svavelföreningar Del 1: Allmän introduktion (ISO :2007)

SVENSK STANDARD SS- EN ISO :2015/A1:2017

Tillägg 1 (ISO :1997/Amd 1:2009)

SVENSK STANDARD SS-EN ISO 9876

Aerospace series Lamps, incandescent Part 007: Lamp, code 74 Product standard SWEDISH STANDARDS INSTITUTE

SVENSK STANDARD SS-EN ISO

SVENSK STANDARD SS-EN ISO

SVENSK STANDARD SS-EN 299

Fertilizers Determination of the water-soluble potassium content SWEDISH STANDARDS INSTITUTE

SVENSK STANDARD SS-EN ISO :2011/AC:2013

SVENSK STANDARD SS-EN 1728:2012/AC:2013

SVENSK STANDARD SS-EN ISO

SVENSK STANDARD SS-EN ISO 5555/A1:2014

Geometriska produktspecifikationer (GPS) Längdindikatorer Mätklockor, konstruktion och metrologiska egenskaper (ISO 463:2006/Cor 1:2007/Cor 2:2009)

Eurokod 9: Dimensionering av aluminiumkonstruktioner Del 1-2: Brandteknisk dimensionering

SVENSK STANDARD SS-EN ISO

SVENSK STANDARD SS-EN ISO

Ritregler Kanter med odefinierad form Terminologi och ritningsangivning. Technical drawings Edges of undefined shape Vocabulary and indications

SVENSK STANDARD SS-EN ISO 9706

SVENSK STANDARD SS-EN ISO 11409

Nödduschar och anordningar för ögonspolning Del 3: Nödduschar ej fast anslutna till vattenledning

SVENSK STANDARD SS-EN ISO 11987

Oförstörande provning av svetsar Magnetpulverprovning (ISO 17638:2003) Non-destructive testing of welds Magnetic particle testing (ISO 17638:2003)

SVENSK STANDARD SS-EN ISO :2009/AC:2010


Tillsyn vid svetsning Uppgifter och ansvar (ISO 14731:2006) Welding coordination Tasks and responsibilities (ISO 14731:2006)

SVENSK STANDARD SS-EN ISO

Eurokod 3: Dimensionering av stålkonstruktioner Del 4-3: Rörledningar. Eurocode 3 Design of steel structures Part 4-3: Pipelines

SVENSK STANDARD SS-EN ISO 14534

Eurokod 8: Dimensionering av bärverk med avseende på jordbävning Del 2: Broar

SVENSK STANDARD SS-EN ISO

SVENSK STANDARD SS-EN ISO

SVENSK STANDARD SS-EN :2007+A2:2012/AC:2013

SVENSK STANDARD SS-EN

Produkter för behandling av vatten för simbassänger Aktivt kol. Products used for treatment of swimming pool water Powdered activated carbon

SVENSK STANDARD SS-EN 13612/AC:2016

SWEDISH STANDARDS INSTITUTE

Brand och räddning Brandslangar Sugslangar för brandbekämpning (ISO 14557:2002/Amd 1:2007)

SVENSK STANDARD SS-EN 12945:2008

SVENSK STANDARD SS-EN ISO 140-7

SVENSK STANDARD SS-EN ISO

SVENSK STANDARD SS-EN ISO 2578

SWEDISH STANDARDS INSTITUTE

SVENSK STANDARD SS-EN ISO 308

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN

Oförstörande provning av svetsar Magnetpulverprovning av svetsar Acceptansnivåer (ISO 23278:2006)

SVENSK STANDARD SS-EN ISO

Tandvård Medicintekniska produkter för tandvård Dentala implantat. Dentistry Medical devices for dentistry Dental implants SWEDISH STANDARDS INSTITUTE

Transkript:

Teknisk rapport SIS-CEN/TR 15641:2007 Publicerad/Published: 2007-12-03 Utgåva/Edition: 1 Språk/Language: engelska/english ICS: 67.050 Food analysis Determination of pesticide residues by LC-MS/MS Tandem mass spectrometric parameters SWEDISH STANDARDS INSTITUTE

Hitta rätt produkt och ett leveranssätt som passar dig Standarder Genom att följa gällande standard både effektiviserar och säkrar du ditt arbete. Många standarder ingår dessutom ofta i paket. Tjänster Abonnemang är tjänsten där vi uppdaterar dig med aktuella standarder när förändringar sker på dem du valt att abonnera på. På så sätt är du säker på att du alltid arbetar efter rätt utgåva. e-nav är vår online-tjänst som ger dig och dina kollegor tillgång till standarder ni valt att abonnera på dygnet runt. Med e-nav kan samma standard användas av flera personer samtidigt. Leveranssätt Du väljer hur du vill ha dina standarder levererade. Vi kan erbjuda dig dem på papper och som pdf. Andra produkter Vi har böcker som underlättar arbetet att följa en standard. Med våra böcker får du ökad förståelse för hur standarder ska följas och vilka fördelar den ger dig i ditt arbete. Vi tar fram många egna publikationer och fungerar även som återförsäljare. Det gör att du hos oss kan hitta över 500 unika titlar. Vi har även tekniska rapporter, specifikationer och workshop agreement. Matriser är en översikt på standarder och handböcker som bör läsas tillsammans. De finns på sis.se och ger dig en bra bild över hur olika produkter hör ihop. Standardiseringsprojekt Du kan påverka innehållet i framtida standarder genom att delta i någon av SIS ca 400 Tekniska Kommittéer. Find the right product and the type of delivery that suits you Standards By complying with current standards, you can make your work more efficient and ensure reliability. Also, several of the standards are often supplied in packages. Services Subscription is the service that keeps you up to date with current standards when changes occur in the ones you have chosen to subscribe to. This ensures that you are always working with the right edition. e-nav is our online service that gives you and your colleagues access to the standards you subscribe to 24 hours a day. With e-nav, the same standards can be used by several people at once. Type of delivery You choose how you want your standards delivered. We can supply them both on paper and as PDF files. Other products We have books that facilitate standards compliance. They make it easier to understand how compliance works and how this benefits you in your operation. We produce many publications of our own, and also act as retailers. This means that we have more than 500 unique titles for you to choose from. We also have technical reports, specifications and workshop agreements. Matrices, listed at sis.se, provide an overview of which publications belong together. Standardisation project You can influence the content of future standards by taking part in one or other of SIS s 400 or so Technical Committees.

Denna tekniska rapport är inte en svensk standard. Detta dokument innehåller den engelska språkversionen av CEN/TR 15641:2007. This Technical Report is not a Swedish Standard. This document contains the English version of CEN/TR 15641:2007. Copyright/Upphovsrätten till denna produkt tillhör SIS, Swedish Standards Institute, Stockholm, Sverige. Användningen av denna produkt regleras av slutanvändarlicensen som återfinns i denna produkt, se standardens sista sidor. Copyright SIS, Swedish Standards Institute, Stockholm, Sweden. All rights reserved. The use of this product is governed by!the end-user licence for this product. You will find the licence in the end of this document. Upplysningar om sakinnehållet i standarden lämnas av SIS, Swedish Standards Institute, telefon 08-555 520 00. Standarder kan beställas hos SIS Förlag AB som även lämnar allmänna upplysningar om svensk och utländsk standard. Information about the content of the standard is available from the Swedish Standards Institute (SIS), tel +46 8 555 520 00. Standards may be ordered from SIS Förlag AB, who can also provide general information about Swedish and foreign standards. SIS Förlag AB, SE 118 80 Stockholm, Sweden. Tel: +46 8 555 523 10. Fax: +46 8 555 523 11. E-mail: sis.sales@sis.se Internet: www.sis.se

TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 15641 August 2007 ICS 67.050 English Version Food analysis - Determination of pesticide residues by LC- MS/MS - Tandem mass spectrometric parameters Analyse des produits alimentaires - Détermination des résidus de pesticides par CL-SM/SM - Paramètres de spectrométrie de masse en tandem Lebensmitteluntersuchung - Bestimmung von Pestizidrückständen mit LC-MS/MS - Parameter für die Tandem-Massenspektrometrie This Technical Report was approved by CEN on 25 July 2007. It has been drawn up by the Technical Committee CEN/TC 275. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. CEN/TR 15641:2007: E

Contents Page Foreword...3 Introduction...4 1 Scope...5 2 Analyte specific parameters for selective reaction monitoring of pesticides...5 2.1 General...5 2.2 LC Parameters...6 2.3 General MS/MS parameters...6 2.4 Analyte specific MS/MS Parameters...7 Bibliography...23 2

Foreword This document (CEN/TR 15641:2007) has been prepared by Technical Committee CEN/TC 275 Food analysis - Horizontal methods, the secretariat of which is held by DIN. 3

Introduction Pesticide residue analysis employs multi methods involving extraction of residues from foods and clean up of the extract to obtain as many pesticide residues as possible in the purified extracts. Afterwards the extracts can be analysed by different kinds of instruments. The hyphenation of liquid chromatography (LC) and tandem mass spectrometry (MS/MS) has become one of the most universal, but selective and sensitive analysis techniques for identification and quantification of pesticide residues in extracts of foods. For the ionization of the analytes (M) in LC-MS/MS, electro spray ionization (ESI) or atmospheric pressure chemical ionization (APCI) interfaces are most commonly used. Depending on the selected polarity of the ionization, protonated or deprotonated molecular ions like [M+H] + or [M-H] - are generated. Using ESI, relatively stable adducts (clusters) of the analytes (M) and components of the mobile phase like ions (e.g. ammonium, sodium or potassium ions) or solvent molecules (e.g. methanol) can be additionally formed. To obtain a high yield of quasi molecular ions and therefore to increase the sensitivity of the measurement these clusters have to be broken. When using ESI the formed adducts are accelerated by a potential (e.g. declustering potential or cone voltage) in the ion source at atmospheric pressure. Due to collision with neutral gas molecules the clusters (adducts) are broken in the ion source. Under certain conditions some adduct-ions formed are stable (e.g. with ammonium cation [M+NH 4 ] + ). It should be mentioned, however, that ammonium adducts are usually not generated in the APCI-mode and that their formation when using ESI strongly depends on the concentration of ammonium ions in the LC mobile phase. Adduct ions like [M+NH 4 ] + can also be used alternatively for quantification if they were shown to provide reproducible signals. Sodium adducts are usually not suitable for quantitative analysis as their formation and decomposition tends to be highly irreproducible. The selective determination of each target compound is performed by acquisition of characteristic product ions of the precursor ion (quasi molecular ion or adduct) in the selected reaction monitoring (SRM). Decomposition of the precursor ions in the collision cell is induced by collision with molecules of the collision gas (nitrogen or argon). The collision energy (CE) necessary for fragmentation is a very substantial parameter of the MS/MS optimization for maximum sensitivity. If LC-MS/MS measurement should be used not only for quantification but also for confirmation of positive findings, at least two SRM transitions have to be recorded. 4

1 Scope This Technical Report lists mass spectrometric parameters which are useful for the application of European Standards for the determination of pesticide residues in foods of plant origin that use LC-MS/MS, such as the standards in preparation: pren 15637 "Foods of plant origin Determination of pesticide residues using LC-MS/MS following methanol extraction and clean up using diatomaceous earth" pren 15662 "Foods of plant origin Determination of pesticide residues using GC-MS and/or LC-MS/MS following acetonitrile extraction/partitioning by dispersive SPE QuEChERS-method To facilitate the determination of active substances and/or metabolites using LC-MS/MS, Table 1 specifies the precursor ions and product ions suitable for quantification, which can be used independently of the type of triple quadrupole mass spectrometer. However, using an ion trap mass spectrometer other product ions can be generated or at least the relative intensities of the ions are different to triple quadrupole instruments. Furthermore, the additional parameters declustering potential (DP), collision energy (CE), relative retention times and an approximate classification of detection sensitivity are presented in Table 1. These were derived using the API 2000 1 ) and should be applicable at least for other instruments of the API type (Applied Biosystems). 2 Analyte specific parameters for selective reaction monitoring of pesticides 2.1 General All values indicated in Table 2 were acquired using the above mentioned LC-MS/MS system under the experimental conditions as outlined in 2.2. Comparative investigations showed that these parameters can be transferred simply on instruments of other types of the same manufacturer or after adjustment also on devices of other manufacturers (see in 2.3) 1 ) Instruments of the API type are products supplied by Applied Biosystems (Foster City, CA, USA). This information is given for the convenience of users of this Technical Report and does not constitute an endorsement by CEN of the product named. Equivalent products may be used if they can be shown to lead to the same results. 5

2.2 LC Parameters The following LC operating conditions have been proven to be satisfactory. This is an example for appropriate experimental conditions. Equivalent conditions may be used if they can be shown to lead to the same results. HPLC pump Autosampler Injection volume Column Mobile phase A Mobile phase B Flow rate HP1100 2 ) Binary Pump (G1312A) HP1100 (G1313A) 20 μl Phenomenex 3 ) Aqua 5 μ C18 125 Å, 50 mm 2 mm Methanol/water 2+8 (V/V) with 5 mmol/l ammonium formate Methanol/water 9+1 (V/V) with 5 mmol/l ammonium formate 0,2 ml/min Column temperature 20 C Gradient Linear: 0 min 0 % B 11 min 100 % B 23 min 100 % B 25 min 0 % B 36 min 0 % B (equilibration time) As slight fluctuations in the measurement conditions influence the retention time, usually relative retention times (RRT), related to a standard substance, are compared. The standard substance for the calculation of the RRT values in Table 1 was Imazalil (RRT = 1,000). It could be shown that the use of other mobile phase systems does not shift the order of elution substantially, except for those compounds which are sensitive to the ph of eluent. Often retention data can be transferred to HPLC columns of other manufacturers, if a typical reversed phase is used. 2.3 General MS/MS parameters The following general MS/MS operating conditions have been proven to be satisfactory. This is an example for appropriate experimental conditions. Equivalent conditions may be used if they can be shown to lead to the same results MS/MS instrument Applied Biosystems API 2000 Ion source Turbo Ion Spray (ESI) 2 ) Instruments of the HP type are products supplied by Agilent Technologies Inc. (Palo Alto, CA, USA). This information is given for the convenience of users of this Technical Report and does not constitute an endorsement by CEN of the product named. Equivalent products may be used if they can be shown to lead to the same results. 3 ) HPLC columns of the Aqua type are products supplied by Phenomenex (Torrance, CA, USA). This information is given for the convenience of users of this Technical Report and does not constitute an endorsement by CEN of the product named. Equivalent products may be used if they can be shown to lead to the same results. 6

Table 1 Ion source and general parameters Ion polarity positive Gas 2 temperature 400 C Curtain gas nitrogen, 35 psi (241 kpa) Resolution MS 1 unit Collision gas nitrogen, 2 arbitrary units Resolution MS 2 unit Ion spray voltage 5500 V Dwell time 25 ms Gas 1 nitrogen, 60 psi (414 kpa) Focusing potential 360 V Gas 2 nitrogen, 60 psi (414 kpa) 2.4 Analyte specific MS/MS Parameters The analyte specific parameters for selective reaction monitoring of pesticides are listed in Table 1 [1]. The names of the individual analytes are supplemented by the CAS number (Chemical Abstracts Service), which is useful for the search in databases. It is usually taken from [2], but there can be several numbers in individual cases, e.g. for isomers and racemates. The values for the declustering potential (DP), indicated in Table 1 for the API 2000, have to be increased by 20 V for tandem mass spectrometers of the type API 3000 or API 4000. It is to be considered that DP breaks not only the clusters but can already induce fragmentation of the precursor ions (at too high values) in the ESI source before entering into the first MS. NOTE It is not necessary to change the collision energy for API 3000 or API 4000 instruments as the differences for the CE are less than 5 V. When using tandem mass spectrometers of other manufacturers the correct value for the collision energy should be determined in tuning experiments for analytes with particularly low and high collision energy since it has relevant influence on the intensity of the SRM transition. Based on these data, in a first approximation the values for the collision energy of further pesticides can be derived proportionally from the data in the table and the observed difference (difference of CE at instrument X to the API 2000 ). The values of the declustering potential (other name cone voltage ) for other instruments have to be determined individually. On the intensity of the SRM transitions this parameter has a smaller influence than the collision energy. Table 2 MS/MS Parameters of 497 analytes Pesticide (Metabolite) 1 st SRM 2 nd SRM CAS No. Ionization Quasi molecular ion Q1 Mass (amu) Declustering potential (V) Q3 Mass (amu) Collision energy (V) Q3 Mass (amu) Collision energy (V) Relative retention on endcapped RP phase a Sensitivity of detection b 2,4-D 94-75-7 ESI - [M-H]- 219,0-21 160,9-14 124,9-34 0,69 *** 2,4-DB 94-82-6 ESI - [M-H]- 247,0-66 160,8-12 124,9-34 0,86 *** 2-Naphthyloxyacetic acid 120-23-0 ESI + [M+NH4]+ 220,1 36 157,1 19 127,1 43 0,66 n.a. 2-Naphthyloxyacetic acid 120-23-0 ESI - [M-H]- 201,1-71 143,0-18 114,9-50 0,66 *** 3,4,5-Trimethacarb 2686-99-9 ESI + [M+H]+ 194,1 61 137,1 15 122,0 35 0,86 **** 4-CPA 122-88-3 ESI - [M-H]- 185,0-71 126,8-18 140,7-12 0,47 ** Acephate 30560-19-1 ESI + [M+H]+ 184,1 6 124,9 25 142,9 13 0,11 **** Acetamiprid 135410-20-7 ESI + [M+H]+ 223,0 36 126,0 27 90,1 45 0,58 **** 7