RC /23 Prox Ver. 3.4

Storlek: px
Starta visningen från sidan:

Download "RC /23 Prox Ver. 3.4"

Transkript

1 Installatörs-- handbok AXCARD RC /23 Prox Ver. 3.4

2 Ver 3.4 AXPROX INNEHÅLLSFÖRTECKNING RC426-22/23 Prox INTRODUKTION... 3 INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING... 3 INITIERING OCH NOLLSTÄLLNING AV MINNET... 3 INITIERING OCH NOLLSTÄLLNING AV MINNET... 3 ALT. 1 INLÄGGNING AV PROGRAMMERINGSKOD ALT. 2 INLÄGGNING AV PROGRAMMERINGSKOD OCH KORT ANSLUTNINGSKORT RC MONTERING ANVISNING FÖR KABELINTAG... 7 ANSLUTNING AV TERMINALER... 7 INKOPPLING AV PRINTER... 8 INKOPPLING AV LD-3K PROGRAMMERING AV SPECIALPARAMETRAR # 32 INLÄGGNING AV ANTAL I KORTRÄKNARE...10 # 33 LARMPUNKT I KORTRÄKNARE...10 # KORTPARAMETRAR # BESÖKSKORTSPARAMETRAR # PARAMETRAR FÖR ANTI-PASSBACK (APB) (TYP -23) # UTGÅNG 9 (TYP -22/23) # EXTERN LARMINKOPPLINGSBLOCKERING (TYP -22) # PARAMETER FÖR LARMSTYRNING (TYP -22)...14 # PARAMETER FÖR LARMSTYRNING MED TIDZON (TYP -22).14 # PARAMETER FÖR MODEMSTYRNING RC-426-xx:...15 # 64 PARAMETRAR FÖR UT-LÄSARE (PL6)...15 # 66 ÖVERFÖRINGSHASTIGHET TILL SKRIVARE / PC # TIDZON FÖR FJÄRRÖPPNING ANSLUTNING AV LARM (RC ) FUNKTIONSBESKRIVNING Bistabil funktion Monostabil funktion Pulsfunktion...17 FJÄRRÖPPNINGSKNAPPENS FUNKTION

3 AXPROX Ver 3.4 LARMINDIKERINGSUTGÅNGENS FUNKTION...18 LARMDIODENS FUNKTION...18 KOPPLINGSEXEMPEL MED LARM...19 LARMFÖRBIKOPPLING MONOSTABIL FUNK STYRNING AV LARM BISTABIL FUNK STYRNING AV LARM PULS FUNK FLERA LÄSARE PROGRAMMERING AV LARMFUNKTION (RC )...21 # 53 BESTÄM LARM MANÖVRERINGSFUNKTION...21 # 54 TID FÖR VARNINGSSUMMER # 69 PARAMETRAR FÖR KVITTENS OCH LARM DIOD...22 # TIDZON FÖR LARMTILLSLAG...23 BYTE AV EPROM PERSONLIG KOD (PIN) TILL/FRÅNKOPPLING AV LARM...23 INKOPPLING AV LÄSARTERMINAL PR MONTERING AV PROX-LÄSARE PR-543G PÅ GLASPARTI INKOPPLING AV LÄSARTERMINAL PR-543G...26 INKOPPLING AV LÄSARTERMINAL PR INKOPPLING AV LÄSARTERMINAL PR INKOPPLING AV LÄSARTERMINAL PR VIKTIG INFORMATION OM PROXLÄSARE PR INKOPPING AV PROXTERMINAL PR KOPPLINGSEXEMPEL FÖR PROXLÄSARE PR

4 Ver 3.4 AXPROX AXCARD RC /23 Prox INTRODUKTION. Till kontrollenheten kan samtliga AXEMAS proxterminaler anslutas, enheten har två reläer som vardera har en fri växelkontakt,. På de jackbara plintarna finns ingångar för 2 terminaler, printer/pc, AXNET, öppningsknapp, dörrkontakt extern larminkoppling, återkoppling från larmcentral, sabotage switch, mm. RC hanterar passerkort, larmkort, besökskort. Den har årskalender med automatisk vinter/sommartid, 8 behörighetsgrupper, 63 tidzoner och 7 säkerhetsnivåer. Den kan dessutom hantera inbrottslarm, överfallslarm, och har dörrövervakning. Den kan kopplas samman i system med eller utan AXBASE. Enheten är försedd med knappsats samt tre lysdioder och summer för indikering under programmering. Matningsspänningen kan vara 12-30VDC filtrerad eller 12-18VAC strömförbrukningen är max. 250mA. En 12VDC utgång finns för drivning av externa enheter t.ex. proxläsare eller extra relä. Använd AXEMAS transformator för att undvika problem. INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING Innan programmering påbörjas skall kortläsaren initieras med en speciell kod, (se nedan.) Denna kod tömmer minnet sätter upp tidszoner och div. parametrar, den anger också språk för printerutskrifter. Initieringskoden är för Sverige. Om AXBASE 3K användes skall en speciell nollställning göras se nedan. INITIERING OCH NOLLSTÄLLNING AV MINNET. (Gäller AXBASE 16/32 eller stand alone montage.) - Öppna kontrollenheten. - Tryck på RST-knappen (1 pip hörs), släpp den (2 pip hörs). - Slå (2 pip hörs).tryck # (6 pip hörs). OBS! Minnet töms! INITIERING OCH NOLLSTÄLLNING AV MINNET. (Gäller AXBASE 3K.) - Öppna kontrollenheten. - Håll inne RST-knappen. - Ett antal pip hörs under 5 sek, sedan kommer 6 st snabba pip. - Släpp RST knappen nollställningen är klar. OBS! Minnet töms! 3

5 AXPROX Ver 3.4 ALT. 1 INLÄGGNING AV PROGRAMMERINGSKOD. - Tryck på RST-knappen. - Knappa in en 6-siffrig kod på knappsatsen. - Tryck #. Programmeringskoden är nu inlagd. - Stäng enheten. Följande Programmeringskoder kan ej användas: , ALT. 2 INLÄGGNING AV PROGRAMMERINGSKOD OCH KORT. OBS! Gäller endast vid manuell programmering EJ AXBASE. - Tryck på RST-knappen. - Knappa in en 6-siffrig kod på knappsatsen. - Håll det för programmering avsedda kortet/brickan framför läsaren. OBS! Läsaren måste vara ansluten till PL7. - Tryck #. Programmeringskortet med tillhörande programmeringskod är nu inlagt. - Stäng kortläsaren. Programmeringskortet kan även användas som passerkort Lägg in ett kort/bricka på följande vis för att prova läsaren: - Ställ läsaren i programmeringsläge med Din programmeringskod/kort. - Tryck # 01 håll kortet/brickan framför läsaren tryck # * - Håll kortet/brickan framför läsaren och dörren ska öppna. Skall läsaren ingå i ett nätverk gå vidare till AXNET manualen. ANSLUTNINGSKORT RC Plint PL1 - För anslutning av MATNINGSSPÄNNING och ELLÅS. Plint PL2 - För anslutning av FJÄRRÖPPNING. Plint PL3 - För anslutning av SABOTAGESWITCH. Plint PL4 - För anslutning av PRINTER eller PC. Plint PL5 - För anslutning av TVÅTRÅDSKOMMUNIKATION. Plint PL6 och PL7 - För anslutning av LÄSARTERMINALER. RST används för att "INITIERING" ( uppstartning ) och "INLÄGGNING AV PROGRAMMERINGSKOD". NODE används för att bestämma "ADRESS" när flera läsare är sammankopplade via tvåtrådskommunikation. Byglarna TERM är för terminering av första och sista läsaren i ett nätverk. För terminering flytta byglarna till den vänstra positionen. Lysdiod LD4 indikerar kommunikation. 4

6 Ver 3.4 AXPROX MONTERING. Kontrollenheten skall placeras inomhus på sk. larmat område och så nära dörren som möjligt. Avståndet till läsarterminalerna får ej vara mer än 25 m och så kort som möjligt. I kabeln till terminaler får ej andra signaler än terminalens egna förekomma. Installera kontrollenheten på följande vis: - Öppna kontrollenheten med den medföljande nyckeln. - Skruva fast lådan på väggen - Anslut kablarna i enlighet med inkopplingstabellen. - Stäng kontrollenheten och lås lådan. - Förvara nyckeln det på säker plats. LED PL FREE TAMPER LED SWITCH PL ,24V AC/DC DOOR RELAY ALARM BYPASS RELAY ALARM LED +12 V NODE RST ON OFF V SW7 ON LED OFF KEY SW8 RED LED PULS LARM BIST YEL. LED GRN. LED BUZZER CLS RCP RDP PL6 PL V KEY RED LED YEL. LED GRN. LED BUZZER CLS RCP RDP PL RxD TxD LED PL5 TERM # RS485 5

7 AXPROX Ver 3.4 Matningsspänningen skall anslutas till PL1:1 och PL1:2. Om spänning skall läggas ut till ellåset, skall en bygel läggas mellan PL1:2 och PL1:3. Låset ansluts mellan PL1:1 och PL1:4. Lås med omvänd funktion ansluts mellan PL1:1 och PL1:5. Fjärröppningsknappen ansluts mellan PL2:25 och PL2:26. Sabotageswitchen ansluts mellan PL3:13 och PL3:14. Den anslutna larmslingan får vara max. 30VDC - 100mA. 6

8 Ver 3.4 AXPROX ANVISNING FÖR KABELINTAG. Kabelintag. Sedd bakifrån ANSLUTNING AV TERMINALER. KABELINTAG I TERMINALLÅDA Plint PL6 och PL7 på RC-426-serien är till för anslutning av läsarterminaler. Största tillåtna avstånd mellan kontrollenheten och en terminal är 25m och kabeln skall vara skärmad och skärmen ansluten i båda kåporna. Hur terminalerna skall anslutas visas i slutet av denna manual. Notera: Om man skall ansluta en terminal för inpassering till en kontrollenhet måste den vara ansluten till PL7 7

9 AXPROX Ver 3.4 INKOPPLING AV PRINTER. Printer ansluts på plint PL4. Om Du har ett AXNET nätverk kopplar Du printern till mastern via isolatorn. = signaljord ( 0 V ) TxD = Data ut ( från kortläsare ) utgång 8

10 Ver 3.4 AXPROX INKOPPLING AV LD-3K ,24V TxD RxD RxD TxD LD1 LD2 LD3 9

11 AXPROX Ver 3.4 PROGRAMMERING AV SPECIALPARAMETRAR. De två följande kommandona används endast i läsare av typ -23. Denna läsare har en räknare som håller reda på hur många kort som är inne. Det första kommandot används för att programmera denna räknare till ett valt värde, (ange hur många bilar som finns i garaget när läsaren körs igång. Du måste även programmera # ) # 32 INLÄGGNING AV ANTAL I KORTRÄKNARE. - Tryck # 32 - Slå antal innekort ( xx siffror) - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ett larm kan erhållas när ett visst antal kort är inne (garaget är fullt). Se även # # 33 LARMPUNKT I KORTRÄKNARE. - Tryck # 33 - Slå antal innekort ( xx siffror) för larm. - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Följande kommandon används endast för att ändra läsarens funktion och behöver normalt inte användas. Det har också ett subkommando 01 till 99. Initieringskoden påverkar inte dessa inställningar. # KORTPARAMETRAR. Med detta kommando kan man ändra från vilken position på kortet man vill börja läsa och hur många tecken. - Tryck # Slå positionen ( två siffror ) - Slå antal tecken ( två siffror max 08 ) - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex:. # # läs sex siffror fr. o m pos. 5. Axcards standardinställning är # Denna inställning innebär följande: Om Du har 16 siffror eller mer, läser den pos. 9 till 16. Har Du 8 till 15 siffror läser den de 8 sista siffrorna. Har Du mindre än 8 siffror läser den de siffror som finns och lägger till inledande nollor så att det blir 8 siffror. OBS! Om Du ändrar från standardinställningen innebär det att Du inte kan använda kort av olika typ. 10

12 Ver 3.4 AXPROX Med kommandot kan man ändra så att kortläsaren läser de siffror som slås på knappsatsen som ett kortnummer. I detta läge fungerar endast knappsatsen och inte kortläsaren. Kommandot följs av två siffror som anger antalet siffror i koden. Tillåtna värden är: 02, 04, 06 och 08. Koderna programmeras med kommandot #01 och måste innehålla 8 siffror. Koden 1234 måste programmeras Ex: # Programmerat värde kontrolleras genom utskrift # # BESÖKSKORTSPARAMETRAR. läs en fyrsiffrig kod från knappsatsen. Med detta kommando kan man välja om besökstiden skall räknas i timmar, dagar, månader eller gånger. Om man valt dagar sker framräkning klockan Har man valt månad sker framräkningen den första i månaden vid samma klockslag. Har Du flera läsare sammankopplade i ett system, sker räkningen för systemet och inte för varje läsare. Du får heller inte ha olika parametrar på läsarna i ett system. Parametern gäller också för samtliga besökskort. - Tryck # Slå 0 = minuter, 1 = timmar, 2 = dagar, 3 = månader eller 4 = gånger. Axcards standardinställning är # Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex. # # besökstiden räknas i dagar Programmerat värde kontrolleras genom utskrift # # PARAMETRAR FÖR ANTI-PASSBACK (APB) (TYP -23). Om flera läsare mod. -23 är sammankopplade i system kan APB fungera på två sätt: 1. - System APB vilket innebär att när ett kort läses i en IN-läsare skickas ett meddelande till de andra läsarna att nu är kortet INNE 2. - Lokal APB innebär att INNE/UTE -status lagras lokalt i respektive läsare. - Tryck # Slå 1 för system APB eller 2 för lokal APB. Axcards standardinställning är # vilket betyder system APB. - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex: # # lokal APB Programmerat värde kontrolleras genom utskrift #

13 AXPROX Ver 3.4 # PRINTERHASTIGHET. Med detta kommando kan man ändra på antalet tecken/sek som skickas ut från läsaren. Detta gör det möjligt att anpassa olika printrar utan att använda en DTR-signal. Möjliga värden är 10 till 240 tecken/sek. Max teckenhastighet för respektive baudhastighet är: 300 baud 30 t/s 600 baud 60 t/s 1200 baud 120 t/s 2400 baud 240 t/s - Tryck # Slå tecken/sek ( 3 siffror ) - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex: # # Programmerat värde kontrolleras genom utskrift # Axcards standardinställning är 1200 baud med 120 t/s 30 tecken per sekund 12

14 Ver 3.4 AXPROX # UTGÅNG 9 (TYP -22/23). Med detta kommando kan man lägga utgång 9 låg när "dörr öppen larm" eller "överfallslarm" är aktiv. På detta sätt kan ett externt relä anslutas för att driva en extern summer. Utgången har ingen skyddsdiod så en sådan måste läggas över reläspolen. - Tryck # Slå 2 för "dörr öppen larm", 3 för "överfallslarm eller 4 för larmpunkt. Axcards standardinställning är # vilket innebär larmdiodutgång. - Tryck #. Läsaren återgår till programmeringsläge. Ex. # # Har man en läsare typ -23 kan man genom att välja parametern 4 kan man få utgången att larma för ett visst antal INNE-kort. Programmeringen måste kompletteras med programmering av # 32 och # 33. Ex. # # Programmerat värde kontrolleras genom utskrift # larma när x antal kort är inne. (garaget är fullt) # EXTERN LARMINKOPPLINGSBLOCKERING (TYP -22). Med detta kommando kan man ändra funktionen på ingång 27. Om 1 är programmerad är ingången den normala larmingången. Om 2 är programmerad fungerar ingång 27 på följande sätt: Hög nivå (öppen kontakt) larmet kan inte slås till. Låg nivå (sluten kontakt) larmet kan slås till. Om 3 är programmerat registreras ingång 27 som en händelse på följande sätt: Hög nivå (kontakten öppnas) = ingång 27 OFF. Låg nivå (kontakten sluts) = ingång 27 ON. - Tryck # Slå 1 för normal funk. 2 för blockering eller 3 för händelseregistrering. Axcards standardinställning är # Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex. # # Programmerat värde kontrolleras genom utskrift #

15 AXPROX Ver 3.4 # PARAMETER FÖR LARMSTYRNING (TYP -22). Med detta kommando kan man ändra så att larmkort kan användas utan PIN-kod. - Tryck # Slå 1 för normal funk. 2 för styra larm med kort och *. Axcards standardinställning är # Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex: # Programmerat värde kontrolleras genom utskrift # # PARAMETER FÖR LARMSTYRNING MED TIDZON (TYP -22). Med detta kommando kan man ändra så att larmet slås från när tidzonen upphör. Ex: # # - Tryck # Slå 1 för normal funk. 2 för larmfrånslag med tidzon Axcards standardinställning är # Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. larmfrånslag med tidzon Programmerat värde kontrolleras genom utskrift # # PARAMETER FÖR MODEMSTYRNING. Med detta kommando kan man bestämma antalet ringsignaler före svar vid modemuppringning. (används endast tillsammans med AXBASE-programmet) - Tryck # Slå 0 för normal funk. - Slå 1-9 för 1 till 9 signaler före svar. Axcards standardinställning är # Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex: # # modemet svarar efter tre signaler Programmerat värde kontrolleras genom utskrift #

16 Ver 3.4 AXPROX RC-426-xx: Man kan ansluta upp till två läsarterminaler till RC-426-modellerna. Om man ansluter två läsare placeras dessa på var sin sida av dörren och man kan på så sätt styra såväl insom utpassering. I detta fall får man registrering och utskrift på såväl in- som utpasseringar. För att bestämma vad som är in och ut måste vi programmera en parameter. # 64 PARAMETRAR FÖR UT-LÄSARE (PL6). Standarinställning från AXEMA = (1). - Tryck # 64 - Slå < 1 > för terminal utan knappar till PL6 på insida av dörr. - Slå < 3 > för terminal med knappar till PL6 på insida av dörr. - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Programmerat värde kan kontrolleras genom utskrift # 89. Säkerhetsnivån för läsarterminalerna är normalt densamma, men om man har anslutit en terminal utan knappar dvs. ALT. 1 och valt "KORT + PIN" kommer UT-läsaren öppna på endast "KORT". 15

17 AXPROX Ver 3.4 # 66 ÖVERFÖRINGSHASTIGHET TILL SKRIVARE / PC. - Tryck # 66 - Slå < 1200 > = 1200 baud < 2400 > = 2400 baud < 4800 > = 4800 baud - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Programmerat värde kan kontrolleras genom utskrift # 89. Efter initiering är 1200 baud inställt. # TIDZON FÖR FJÄRRÖPPNING. - Tryck # Slå < starttid > < stopptid > < dagtyper > - Tryck #. Tidzonsfunktionen lagras i minnet och läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex: # # fjärröppnings knappen fungerar mellan och måndagar t.o.m. fredagar. Denna tidzon är till vid leverans av läsaren uppsatt så att fjärröppningen alltid fungerar. 16

18 Ver 3.4 AXPROX ANSLUTNING AV LARM (RC ). FUNKTIONSBESKRIVNING. RC har möjligheten att kontrollera ett larm på flera olika sätt. Relä 2 är elektriskt sett ett bistabilt relä som genom programmet kan ges en bistabil, monostabil eller sk. Pulsfunktion (se sid. 21). 1. Bistabil funktion. I bistabilt läge kan läsaren styra en larmcentral dvs. manövrera en larmsektion eller hela centralen. Larmet tillkopplas efter en programmerbar förvarningstid (1-99 sek). Under denna tid ljuder en varningssummer. Larmet kan tillkopplas med en extern larminkopplingsknapp (PL2:27, PL2:28). Denna ingång känner endast en slutning. När larmet är tillkopplat är reläts slutning mellan PL1:6 och PL1:8. När larmet är frånkopplat är slutningen mellan PL1:6 och PL1:7. Bistabil funktion måste kombineras med intern kvittens, d.v.s. ingen återkoppling från larmcentralen. Den interna kvittensen måste programmeras (se sid. 22). 2. Monostabil funktion. I monostabilt läge kan kortläsaren användas som "larmförbikopplare" dvs. förbikoppla en larmsensor. Detta görs monostabilt dvs. relät faller tillbaka efter en tid som kan programmeras till mellan 10 sek och 970 sek i steg om 10 sek. För att få en förvarning innan larmet förbikopplingen upphör använder vi dörr öppen -larmet. Genom att sätta larmförbikopplingstiden till 60 sek och dörrlarmet till 40 sek, får vi en förvarning = 20 sek innan larmet återinkopplas. Detta förutsätter att en dörrkontakt är inkopplad mellan PL2:29 och PL2:30. I monostabilt läge kan förbikoppling även göras med fjärröppningsknappen (PL2:25 PL2:26). När larmet inte är förbikopplat är reläts slutning mellan PL1:6 och PL1:8. När larmet är förbikopplat är slutningen mellan PL1:6 och PL1:7. Monostabil funktion måste också kombineras med intern kvittens, d.v.s. ingen återkoppling från larmcentralen. Den interna kvittensen måste programmeras (se sid. 22). 3. Pulsfunktion. Detta läge används oftast i fallet att flera läsare styr samma larmcentral. I detta fall levererar läsaren en kort puls för till eller från. Larmet inkopplas efter en programmerbar förvarningstid (1-99 sek).under denna tid ljuder en varnings summer. Larmet kan aktiveras med en extern larminkopplingsknapp (PL2:27 PL2:28). Denna ingång känner endast en slutning. När läsaren är i normalläge är reläts slutning mellan PL1:6 och PL1:8. När pulsen kommer är slutningen mellan PL1:6 och PL1:7. Kvittens från larmcentral måste kopplas in mellan PL2:31 och PL2:32. Den måste ha en konstant nivå och vara kopplad med rätt polaritet så att lysdioden i optokopplaren lyser 17

19 AXPROX Ver 3.4 när larmet är tillkopplat. Läsaren måste vara programmerad för extern kvittens. (se sid. 22) FJÄRRÖPPNINGSKNAPPENS FUNKTION. Fjärröppningsknappen fungerar alltid oberoende av om larmet är till- eller frånslaget. Om man har valt monostabil funktion, fungerar fjärröppningsknappen även som frånslag, d.v.s. förbikoppling av larm. LARMINDIKERINGSUTGÅNGENS FUNKTION. Under förutsättning att läsarparametern # inte är ändrad visar utgång 9,10 PL1 larmstatus. Utgången fungerar olika beroende på hur läsaren programmerats. Om man programmerat ALT. 1 eller 2 i # 69 (se sid. 29), visas insignalen på PL2:31 PL2:32 transparent, i fallet 2 dock endast i 10 sek. Har man programmerat alt. 3 eller 4 visas läsarens eget interna larmstatus, i fallet 4 endast i 10 sek. PL ,24V AC/DC DÖRR RELÄ RC LARM- FÖRBIKOPPL. RELÄ LARMDIOD +12V PL EXTRA LED 560 ohm ARK-531 SABOTAGE SWITCH LARMDIODENS FUNKTION. Kortläsarterminalen har även en fri lysdiod som kan indikera larmstatus. Lysdioden kan kopplas så att den styrs direkt från larmcentralen eller kopplas till kontrollenhetens larmindikeringsutgång. Om larmdioden skall styras av kontrollenheten kopplar Du ihop PL1:9 i kontrollenheten med PL3:12 i terminalen och PL1:10 i kontrollenheten med PL3:11 i terminalen. I annat fall ansluts den potentialfria lysdioden med positiv spänning till PL3:11 och negativ till PL3:12. Spänningen skall vara 12V DC. Ett 560 ohms motstånd är anslutet i serie med lysdioden. 18

20 Ver 3.4 AXPROX KOPPLINGSEXEMPEL MED LARM. Vi skall här ge några typiska exempel på inkoppling och programmering av larm. LARMFÖRBIKOPPLING MONOSTABIL FUNK. DÖRRKONTAKT LARMKONTAKT LARMSLINGA PL EXTRA LED PL ,24VDC 12,18VAC LARMDIOD +12V ARK-531 PL2 DÖRR LARM RELÄ RELÄ + FJÄRRÖPPNING EXT. MAN. LARMRELÄ DÖRRÖVERVAKNING 560 ohm RC V 24 V Om Du inte har Axbase, programmerar Du följande: # sek förbikoppling. #69 3 intern kvittens, intern fast visning av larm till. #54 00 förvarningssummer används ej. #52 04 larm öppen dörr efter 40 sek. STYRNING AV LARM BISTABIL FUNK. Extern visning av larmstatus ARK PL FJÄRRÖPPNING + EXTRA LED EXT. MAN. LARMRELÄ DÖRRÖVERVAKNING 560 ohm PL2 PL ,24VDC 12,18VAC DÖRR RELÄ RC LARM RELÄ LARMDIOD +12V 12 V 24 V K1 Om Du inte har Axbase, programmerar Du följande: #53 99 bistabil funktion. #54 30 summer varnar 30 sek. innan larmtillslag. #69 3 intern kvittens, extern visning av larmstatus. 19

21 AXPROX Ver 3.4 STYRNING AV LARM PULS FUNK FLERA LÄSARE. Denna koppling används när flera kortläsare eller något annat manöverdon styr samma larmsektion. Intern visning av larmstatus Extern kvittens av "larm till" PL EXTRA LED PL ,24VDC 12,18VAC LARMDIOD +12V ARK-531 PL2 DÖRR LARM RELÄ RELÄ + FJÄRRÖPPNING EXT. MAN. LARMRELÄ DÖRRÖVERVAKNING 560 ohm RC V 24 V Intern visning av larmstatus PL3 PL EXTRA LED ,24VDC 12,18VAC LARMDIOD +12V ARK-531 PL2 DÖRR LARM RELÄ RELÄ + FJÄRRÖPPNING EXT. MAN. LARMRELÄ DÖRRÖVERVAKNING 560 ohm RC V 24 V Om Du inte har Axbase, programmerar Du följande: #53 98 pulsfunktion. #69 1 extern kvittens av larm till, fast visning av larmstatus på utgång 9. Observera! Larmdiodutgången på larmcentralen måste visa fast sken. Larmcentralen måste aktiveras och skicka kvittens när larmtillkopplingsslingan bryts och inte när den åter sluts (kan vara problem med vissa centraler). Intern visning av larmstatus rekommenderas om LED-utgången på larmcentralen inte orkar driva flera lysdioder. Kontrollera att spänningen på larmcentralens LED-utgång är minst 4 V när larmet är till. Om Du valt att slå till larmet med en tidzon skall denna programmeras på endast en läsare 20

22 Ver 3.4 AXPROX PROGRAMMERING AV LARMFUNKTION (RC ). Som framgår på sid. 24 kan läsaren användas till att styra en larmcentral alternativt förbikoppla en larmsensor. Larmrelät kan därför programmeras till att fungera på tre olika sätt: bistabilt, monostabilt där relät faller tillbaka efter en programmerbar tid och puls, då relät drar endast kort stund. I läget puls väntar läsaren på kvittens från larmcentralen att status är ändrat varefter relät släpper. Om ingen kvittens kommit inom 5 sek. släpper relät ändå. Läget puls måste användas då flera läsare är kopplade till samma larmcentral och läsarna kopplas då normalt i serie. Funktionen väljs genom att programmera # 53. # 53 BESTÄM LARM MANÖVRERINGSFUNKTION. - Tryck # 53 ALT. 1 - MONONOSTABIL FUNKTION - Slå < > Läsaren är inställd för monostabil larmförbikoppling med tiden 10 till 970 sekunder. ( ex: < 03 > = 30 sek. ) ( kräver att man programmerar ALT. 3 eller ALT. 4 i # 69) ALT. 2 - PULS FUNKTION - Slå < 98 > Läsaren är inställd för puls. ( kräver att man programmerar ALT. 1 eller ALT. 2 i # 69 och att man ansluter kvittens från larmcentral. Se sid. 24 " Anslutning av larm " ) ALT. 3 - BISTABIL FUNKTION - Slå < 99 > Läsaren är inställd för bistabil funktion. ( kräver att man programmerar ALT. 3 eller ALT. 4 i # 69) ALT. 4 - INGEN LARM FUNKTION - Slå < 00 > Larmfunktionen är bortkopplad. - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Programmerat värde kan kontrolleras genom utskrift # 83. # 54 TID FÖR VARNINGSSUMMER. - Tryck # 54 - Slå < > - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex: # # Summern kommer att varna i 10 sek. innan larmet kopplas in. Programmerat värde kan kontrolleras genom utskrift # 83. Notera: Summern varnar endast före larminkoppling när Du använder funktionerna bistabil och puls. I läge monostabil varnar dörrövervakningen. 21

23 AXPROX Ver 3.4 # 69 PARAMETRAR FÖR KVITTENS OCH LARM DIOD. - Tryck # 69 ALT. 1 - Slå < 1 > = extern kvittens inkopplad på PL2:31,32. Larmstatus visas kontinuerligt på PL1:9,10. ALT. 2 - Slå < 2 > = extern kvittens inkopplad på PL2:31,32. Larmstatus visas i 10 sek på PL1:9,10. ALT. 3 - Slå < 3 > = intern kvittens. Larmstatus visas kontinuerligt på PL1:9,10. ALT. 4 - Slå < 4 > = intern kvittens. Larmstatus visas i 10 sek på PL1:9,10. - Tryck #. Läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Programmerat värde kan kontrolleras genom utskrift # 83. Notera: Alternativen 1 och 2 används endast vid pulsstyrning. I dessa lägen fungerar larmdioden helt transparent dvs. även en blinkande signal från centralen blir en blinkande diod. ( se sid. 24 "Anslutning av larm." ) Alternativen 3 och 4 innebär att läsaren själv håller reda på larmstatus och måste användas vid monostabil och bistabil funktion. OBS! Har man valt bistabil eller pulsfunktion (se sid. 24) och larmet är aktiverat höjs säkerhetsnivån automatiskt till KORT + PIN och endast "LARMKORT" är giltiga. Har man valt monostabil funktion fungerar "LARMKORT" utan PIN om Du programmerat säkerhetsnivån KORT. Med monostabil funktion kan Du också välja nivån ÖPPNINGSKOD eller ÖPPEN DÖRR. 22

24 Ver 3.4 AXPROX # TIDZON FÖR LARMTILLSLAG. - Tryck # Slå < starttid > < stopptid > < dagtyper > - Tryck #. Tidzonsfunktionen lagras i minnet och läsaren återgår till programmeringsläge. - Tryck *. Läsaren återgår till normalläge. Ex: # # Ex: # # larmet är till mellan och samt mellan och måndag t.o.m. fredag. Tidzonen kompletteras normalt med ytterligare en för lördag och söndag. För programmering av ytterligare larmtidzoner, se användarhandboken kap. fria tidzoner. Observera: Om larmet kopplats från under den tid tidzonen gäller, sker automatisk återinkoppling av larmet efter en timme. BYTE AV EPROM. Lås upp enheten dra loss plintarna. Lossa sen anslutningskortets fästskruv och lyft ur kortet. Ta bort det gamla EPROMet genom att sätta in en liten skruvmejsel mellan EPROMet och IC-hållaren som sitter i kretskortet. OBS!! Notera hur den lilla halvmånen på ena kortsidan sitter. Vrid mejseln så att EPROMet kommer upp. Se till att mejseln inte går ned i kretskortet under EPROMet. Sätt det nya EPROMet i hållaren med markeringen halvmånen som den satt innan. Se till att alla ben går ned i hållaren och inte böjs när EPROMet trycks ned. PERSONLIG KOD (PIN). I förekommande fall se användarhandbok AXCARD. TILL/FRÅNKOPPLING AV LARM. I förekommande fall se användarhandbok AXCARD. 23

25 AXPROX Ver 3.4 INKOPPLING AV LÄSARTERMINAL PR-543. PL1 RC-426 Röd LED (PL6) PL Grön Grön LED Summer Gul Grå Brun CLS RCP RDP Rosa Blå Röd Vit +12V PR-543 Max 25 meter mellan RC-426 och PR-543. Skärmen ansluts till lådans chassi. Prova systemet innan PR-543 ev. muras in. Limma dit overlayen efter monteringen av läsaren. 24

26 Ver 3.4 AXPROX MONTERING AV PROX-LÄSARE PR-543G PÅ GLASPARTI. - Läsaren är avsedd att monteras på insidan av ett glasparti. - Se till att läsaren monteras minst 1 cm från överkanten av glaspartiet så det blir möjligt att se den lysdiod som finns i överkant av läsaren. - Fukta rikligt den del av glaset där läsaren skall monteras med vatten blandat med lite diskmedel. - Avlägsna den transparenta blanka skyddsfolien på framsidan av etiketten. - Tryck fast etiketten mot glaset, och pressa bort vattnet under etiketten genom att dra med en plastspackel från mitten ut mot kanterna. - När etiketten sitter fast ordentligt utan att några luftbubblor finns kvar, tar Du bort det bruna skyddspappret. Tryck sedan fast läsaren mot baksidan av etiketten. - Fäst den fyrpoliga kabeln på lämpligt sätt och koppla den till elektronikboxen. 25

27 AXPROX Ver 3.4 INKOPPLING AV LÄSARTERMINAL PR-543G. MAX. 3 M Vit RC-426 Vit Grön Gul Brun + PR-543-G Röd LED Grön LED Summer CLS RCP RDP (PL6) PL Grå Brun Skär Gul Grön Vit Max 25 meter mellan RC-426 och PR-543-G. 26

28 Ver 3.4 AXPROX INKOPPLING AV LÄSARTERMINAL PR-551. PL V + 5V Tangent Röd LED Gul LED Grön LED Summer CLS RCP RDP PL2 COM RC V COM (PL6) PL PR-551 Extra LED 560 ohm Sabotage switch Från larmcentral för att visa larmstatus Till ex. larmslinga Max 25 meter mellan Central och Terminal 27

29 AXPROX Ver 3.4 INKOPPLING AV LÄSARTERMINAL PR-553. Bistabil/Monostabil förbikoppling med intern visning av larmstatus. PL RC V PL2 (PL6) PL Blå/Röd Grå/Rosa Grön Violett Gul Grå Brun Skär Blå Röd Svart Vit + 5V Grön LED Summer CLS RCP RDP Tangent Röd LED PR Gul LED Max 25 meter mellan Central och Terminal När PR-553 används kan den röda dioden även användas för larmindikering. Röda dioden lyser svagt vid pålarmat och starkare vid nekad passage. Sätt byglarna SW 7 och SW 8 enl. nedan. Vid lev. SW 7 = OFF, SW 8 = PULS. Bist./Monostabilt SW 7 ON SW 8 BIST För terminaler med separat LED för larmindikering sätt byglarna som vid lev. 28

30 Ver 3.4 AXPROX INKOPPLING AV LÄSARTERMINAL PR-553. Bistabil/Puls-förbikoppling med extern visning av larmstatus. PL RC V Kvittens från larmcentral. PR-553 PL2 + (PL6) PL Blå/Röd Grå/Rosa Grön Violett Gul Grå Brun Skär Blå Röd Svart Vit Grön LED Summer CLS RCP RDP V Tangent Röd LED Gul LED Max 25 meter mellan Central och Terminal När PR-553 används kan den röda dioden även användas för larmindikering. Röda dioden lyser svagt vid pålarmat och starkare vid nekad passage. Sätt byglarna SW 7 och SW 8 enl. nedan. Vid lev. SW 7 = OFF, SW 8 = PULS. Bist./Monostabilt Puls SW 7 ON ON SW 8 BIST PULS För terminaler med separat LED för larmindikering sätt byglarna som vid lev. 29

31 AXPROX Ver 3.4 VIKTIG INFORMATION OM PROXLÄSARE PR-623. Med kombinationen DI-623L/PR samt någon av våra centraler erhålles en snygg och smidig kombination av porttelefon med inbyggd proxläsare i en och samma enhet. Det är emellertid en del saker att ta fasta på. - Porttelefonen skall anslutas enligt den medlevererade anvisningen. - Porttelefonen skall även anslutas till centralenheten med medlevererad kabel. Centralenheten skall anslutas enligt den medlevererade anvisningen. - Övriga anslutningar såsom fjärröppning kommunikation etc. måste göras enligt anvisningar för resp. enhet. - Knappsatsen på porttelefon har ingen anslutning till centralenheten detta innebär att PIN-kod för brickorna/korten ej kan användas, samt att programmering av porttelefon görs på porttelefonens knappsats och programmering av centralenheten görs på centralenhetens knappsats. AXBASE 3000 kan även användas för programmering av båda enheterna. - Både porttelefonen och centralenheten måste spänningsmatas. - Ellåset kopplas till centralenheten som då bestämmer öppningstiden, porttelefonens öppningstid ställs ned till 1 sek. och den skall då kopplas till fjärröppningen på centralenheten. Principskiss Trafo AXNET/RS485 Telelinje Ev. tidur Medföljande kabel Fjärröppning RS 232 Ellås - Tänk på att säkerhetskoppling ev. kan behövas. 30

32 Ver 3.4 AXPROX INKOPPING AV PROXTERMINAL PR-623. (PL6) PL7 PL RC-426 Röd LED Grön LED Summer CLS RCP RDP Grön Gul Brun Rosa Blå Röd Vit +12V DI-623L/PR Max 25 meter mellan Central och Terminal Ovanstående anslutning gäller endast proxdelen i porttelefonen övriga anslutningar för respektive apparat måste göras enligt apparaternas manualer. 31

33 AXPROX Ver 3.4 KOPPLINGSEXEMPEL FÖR PROXLÄSARE PR-623. ADI623L-21/99 RC436/426-xx V Komunikation Telelinje K4 7 8 Vit Grön Gul Brun Rosa Blå Röd +12V Röd LED Grön LED CLS RCP RDP Ellås Alternativt TxD 23 RxD RxD TxD AXBASE 3000 Vid programmering av telefonnummer via AXBASE ska i porttelefonen kopplas ihop med i kontrollenheten. grön gul svart TxD RxD KB-1 TxD RxD 23 UNIBASE Vid programmering av telefonnummer via UNIBASE ska KB-1 anslutas. 3 4 Utan Säkerhetsrelä Fjärröppn Alternativt Med Säkerhetsrelä AR Sabotageswitch V Fjärröppn

34 Passagekontroll AB Box STOCKHOLM Installerad av: Tel: Fax: Telefon:

RC /23 Card Ver. 3.3

RC /23 Card Ver. 3.3 Installatörs-- handbok RC-426-22/23 Card Ver. 3.3 Ver 3.3 INNEHÅLLSFÖRTECKNING RC426-22/23 Card INTRODUKTION...3 INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING...3 INITIERING OCH NOLLSTÄLLNING AV MINNET....3

Läs mer

Installatörs- handbok PR-356 Ver. 3.2

Installatörs- handbok PR-356 Ver. 3.2 Installatörshandbok AXCARD PR-356 Ver. 3. Ver. 3. AXCARD INNEHÅLLSFÖRTECKNING PR-356 INTRODUKTION.... INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING.. INITIERING OCH NOLLSTÄLLNING AV MINNET... INITIERING

Läs mer

Installatörs- handbok RC-436 Tele Ver. 3.2

Installatörs- handbok RC-436 Tele Ver. 3.2 Installatörshandbok AXCARD RC-6 Tele Ver.. Ver.. AXCARD INNEHÅLLSFÖRTECKNING RC-6 Tele INTRODUKTION.... INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING.. INITIERING OCH NOLLSTÄLLNING AV MINNET... INITIERING

Läs mer

Installatörs handbok ACR-226 Ver. 3.0

Installatörs handbok ACR-226 Ver. 3.0 Installatörshandbok AXCARD ACR-226 Ver. 3.0 Ver. 3.0 AXCARD INNEHÅLLSFÖRTECKNING ACR-226 INTRODUKTION...2 INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING...2 ALT. 1 INLÄGGNING AV PROGRAMMERINGSKOD....2

Läs mer

Installatörs- handbok RC-436 Code Ver. 3.2

Installatörs- handbok RC-436 Code Ver. 3.2 Installatörshandbok AXCARD RC-436 Code Ver. 3. Ver. 3. AXCODE INNEHÅLLSFÖRTECKNING RC-436 Code INTRODUKTION.... INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING.. INITIERING OCH NOLLSTÄLLNING AV MINNET...

Läs mer

RC-426-22/23 Ver. 3.3

RC-426-22/23 Ver. 3.3 Installatörs-- handbok AXCARD RC-426-22/23 Ver. 3.3 Ver 3.3 AXCARD INNEHÅLLSFÖRTECKNING RC426-22/23 INTRODUKTION...3 INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING...3 INITIERING OCH NOLLSTÄLLNING AV MINNET...3

Läs mer

RC-436 Radio Ver. 3.2

RC-436 Radio Ver. 3.2 Installatörshandbok AXCARD RC-436 Radio Ver. 3. Ver. 3. AXCARD INNEHÅLLSFÖRTECKNING RC-436 Radio INTRODUKTION.... INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING.. INITIERING OCH NOLLSTÄLLNING AV MINNET...

Läs mer

Installatörs- handbok PR-326 Ver. 3.0

Installatörs- handbok PR-326 Ver. 3.0 Installatörshandbok AXCARD PR- Ver..0 Ver..0 AXCARD INNEHÅLLSFÖRTECKNING PR- INTRODUKTION... INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING... INITIERING OCH NOLLSTÄLLNING AV MINNET... ALT. INLÄGGNING

Läs mer

Installatörs- handbok PR-336G Ver. 3.2

Installatörs- handbok PR-336G Ver. 3.2 Installatörshandbok AXCARD PR-336G Ver. 3. Ver. 3. AXCARD INNEHÅLLSFÖRTECKNING PR-336G INTRODUKTION.... INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING.. INITIERING OCH NOLLSTÄLLNING AV MINNET... INITIERING

Läs mer

UNICODE UNICODE CC-434. Ver INTRODUKTION

UNICODE UNICODE CC-434. Ver INTRODUKTION Installatörs- och användarhandbok UNICODE CC-434 V1.2 Ver. 1.2 UNICODE 1. INTRODUKTION UNICODE CC-434 CC-434 är en kontrollenheten för kodlås, den har två reläer som vardera har en fri växelkontakt. Den

Läs mer

Installatörs- och användarhandbok CL-164 V1.2

Installatörs- och användarhandbok CL-164 V1.2 Installatörs- och användarhandbok UNICODE CL-164 V1.2 . Ver. 1.2 UNICODE 1. INTRODUKTION UNICODE CL-164 CL-164 består av knappsats KP-513 samt kontrollenheten CC-434. Kontrollenheten har två reläer som

Läs mer

UNICARD UNICARD RC-434. Ver. 1.2 1. INTRODUKTION

UNICARD UNICARD RC-434. Ver. 1.2 1. INTRODUKTION Installatörs- och användarhandbok UNICARD RC-434 Card V1.2 Ver. 1.2 UNICARD 1. INTRODUKTION UNICARD RC-434 RC-434 är en kontrollenheten för kortavläsning, den har två reläer som vardera har en fri växelkontakt.

Läs mer

Installatörs- och användarhandbok CC-432

Installatörs- och användarhandbok CC-432 Installatörs- och användarhandbok UNICODE CC-432 1. INTRODUKTION UNICODE CC-432 UNICODE Kodlåscentralen är bestyckad med två reläer som vardera har en fri växelkontakt. På de jackbara plintarna finns ingångar

Läs mer

UNIPROX PR INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING

UNIPROX PR INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING Installatörs- och användarhandbok UNIPROX PR-301 Ver. 1.0 UNIPROX 1. INTRODUKTION UNIPROX PR-301 PR-301 består av beröringsfri terminal PR-543 samt kontrollenheten RC-434. Kontrollenheten har två reläer

Läs mer

UNIPROX UNIPROX PR-311. Ver INTRODUKTION

UNIPROX UNIPROX PR-311. Ver INTRODUKTION Installatörs- och användarhandbok UNIPROX PR-311 V1.2 Ver. 1.2 UNIPROX 1. INTRODUKTION UNIPROX PR-311 PR-311 består av beröringsfri terminal PR-553 samt kontrollenheten RC-434. Kontrollenheten har två

Läs mer

Installatörs användarhandbok ACR - 211

Installatörs användarhandbok ACR - 211 Installatörs- och användarhandbok UNICARD ACR-211 1. INTRODUKTION UNICARD ACR-211 UNICARD Kortläsaren har två reläer som vardera har en fri växelkontakt. På de jackbara plintarna finns ingångar för 2 öppningsknappar,

Läs mer

Installatörs användarhandbok ACR-201

Installatörs användarhandbok ACR-201 Installatörs- och användarhandbok UNICARD ACR-201 1. INTRODUKTION UNICARD ACR-201 UNICARD Kortläsaren har två reläer som vardera har en fri växelkontakt. På de jackbara plintarna finns ingångar för 2 öppningsknappar,

Läs mer

DM-420 + AXNET Ver. 1.3

DM-420 + AXNET Ver. 1.3 Installatörshandbok AXCARD DM- + AXNET Ver.. Ver.. DM- INNEHÅLLSFÖRTECKNING DM- INTRODUKTION.... INITIERING OCH NOLLSTÄLLNING AV MINNET... ANSLUTNING AV MASTER DM-... ANSLUTNINGAR I MASTERN... KABLAGE...

Läs mer

UNICODE ACL-121/ INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING

UNICODE ACL-121/ INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING Installatörs- och användarhandbok UNICODE ACL-121/122/123/124 1. INTRODUKTION UNICODE ACL-121/124 Kodlåset är bestyckat med två reläer som vardera har en fri växelkontakt. På den jackbara plinten finns

Läs mer

UNICODE UNICODE ACL-141/ INTRODUKTION

UNICODE UNICODE ACL-141/ INTRODUKTION Installatörs- och användarhandbok UNICODE ACL-141/143 1. INTRODUKTION UNICODE ACL-141/144 Kodlåset är bestyckat med två reläer som vardera har en fri växelkontakt. På de jackbara plintarna finns ingångar

Läs mer

Installatörs- och användarhandbok CL-153AI

Installatörs- och användarhandbok CL-153AI Installatörs- och användarhandbok MINICODE CL-153AI MINICODE CL-153AI 1. INTRODUKTION CL-153AI är bestyckat med ett relä som har en fri växelkontakt. På den jackbara plinten finns ingång för öppningsknapp,

Läs mer

Installatörs- handbok AXNET Ver. 3.0

Installatörs- handbok AXNET Ver. 3.0 Installatörshandbok AXCARD AXNET Ver..0 Ver..0 AXNET INNEHÅLLSFÖRTECKNING AXNET VIKTIGT vid utbyggnad av system... KABLAGE... ANSLUTNING AV TERMINALER.... ÖVRIGA ANSLUTNINGAR.... AXNET NÄTVERK.... INLEDNING...

Läs mer

INNEHÅLLSFÖRTECKNING

INNEHÅLLSFÖRTECKNING Användarhandbok AXCARD CR-236 RC-426-22 Ver. 0.96 PR-326 RC-436 . INNEHÅLLSFÖRTECKNING VER. 0.96 1 INTRODUKTION...1 1.1 HUR ETT AXCARDSYSTEM ÄR UPPBYGGT...1 1.2 HUR ETT PASSAGESYSTEM FUNGERAR...2 2 PROGRAMMERING...5

Läs mer

UDR-Plus Dörrlarm. axema Sida 1. Art. nr / E UDR Plus är ett kompakt dörrlarm, för att övervaka alla typer av dörrar

UDR-Plus Dörrlarm. axema Sida 1. Art. nr / E UDR Plus är ett kompakt dörrlarm, för att övervaka alla typer av dörrar UDR-Plus Dörrlarm Art. nr. 1-9033-3 / E 5870725 UDR Plus är ett kompakt dörrlarm, för att övervaka alla typer av dörrar Se www.axema.se för senaste manualerna. UDR+ Ver. 3.3 axema Sida 1 Beskrivning av

Läs mer

Installatörs- och användarhandbok DI-623-21L

Installatörs- och användarhandbok DI-623-21L Installatörs- och användarhandbok UNITEL DI-623-21L Så fungerar porttelefonen. När det kommer en besökare trycker han # och Ditt anropsnummer (eller direktknappen med ditt namn på). Därefter ringer Din

Läs mer

UDR-Plus Dörrlarm. axema Sida 1. Art. nr / E UDR Plus är ett kompakt dörrlarm, för att övervaka alla typer av dörrar

UDR-Plus Dörrlarm. axema Sida 1. Art. nr / E UDR Plus är ett kompakt dörrlarm, för att övervaka alla typer av dörrar UDR-Plus Dörrlarm Art. nr. 1-9033-3 / E 5870725 UDR Plus är ett kompakt dörrlarm, för att övervaka alla typer av dörrar Se www.axema.se för senaste manualerna. UDR+ Ver. 3.8 axema Sida 1 Beskrivning av

Läs mer

K44 Duo. Installation & User Manual EN SV DE FR DA FI NO

K44 Duo. Installation & User Manual EN SV DE FR DA FI NO K44 Duo Installation & User Manual EN SV DE FR DA FI NO 1 2 3 8 1 6 3 2 5 4 7 A 5 8 0 6 9 B K44 Duo Installation & User Manual EN SV DE FR DA FI NO 1 2 3 8 1 6 3 2 5 4 7 A 5 8 0 6 9 B K44 Duo Installations-

Läs mer

UDR Bakdörrslarm. Ljud och Blixtljus ((utgått)

UDR Bakdörrslarm. Ljud och Blixtljus ((utgått) UDR Bakdörrslarm Ljud Ljud och Blixtljus 1-9033-1 ((utgått) 1-9033-2 UDR är ett bakdörrslarm med eller utan blixtljus, som kan användas till en utrymningsdörr eller för övervakning av en dörr som man vill

Läs mer

Installatörs- och användarhandbok DI-623-99L

Installatörs- och användarhandbok DI-623-99L Installatörs- och användarhandbok UNITEL DI-623-99L Så fungerar porttelefonen. När det kommer en besökare trycker han # och Ditt 2-siffriga anropsnummer alt. endast ditt telefonnummer (eller direktknappen

Läs mer

Codelock K44 Duo. Installation & User Manual. Siemens AB

Codelock K44 Duo. Installation & User Manual. Siemens AB 1 2 3 8 1 6 3 2 5 4 7 A 5 8 0 6 9 B Codelock K44 Duo Installation & User Manual Siemens AB K44 Duo Installations- & Användarhandbok 27 Svenska Tekniska specifikationer och tillgänglighet är föremål för

Läs mer

INNEHÅLLSFÖRTECKNING

INNEHÅLLSFÖRTECKNING Användarhandbok AXCARD ACR-226 RC-426-22 Ver. 0.95 PR-326 PR-436 INNEHÅLLSFÖRTECKNING VER. 0.95 1 INTRODUKTION...1 1.1 HUR ETT AXCARDSYSTEM ÄR UPPBYGGT...1 1.2 HUR ETT PASSAGESYSTEM FUNGERAR...2 2 PROGRAMMERING...5

Läs mer

AXCALL. ADI-611/616/608 Ver 1.7

AXCALL. ADI-611/616/608 Ver 1.7 Projekterings- och installationshandbok AXCALL ADI-611/616/608 Ver 1.7 INNEHÅLLSFÖRTECKNING 1. INTRODUKTION...2 2. BLOCKSCHEMOR...3 Standardinkoppling ADI-611 och ADI-616... 3 Säkerhetskopplad ADI-611

Läs mer

DM-420 IP+ AXNET Ver. 1.3

DM-420 IP+ AXNET Ver. 1.3 Installatörshandbok AXCARD DM-0 IP+ AXNET Ver. 1. Ver. 1. DM-0 IP INNEHÅLLSFÖRTECKNING DM-0 IP INTRODUKTION.... INITIERING OCH NOLLSTÄLLNING AV MINNET... ANSLUTNING AV MASTER DM-0 IP... ANSLUTNINGAR PÅ

Läs mer

Manual Uppdaterad UDR-plus. Axema Access Control AB Box Stockholm, Sweden

Manual Uppdaterad UDR-plus. Axema Access Control AB Box Stockholm, Sweden Manual Uppdaterad 2018-07-31 UDR-plus Axema Access Control AB Box 90215 120 23 Stockholm, Sweden 08-722 34 40 info@axema.se www.axema.se UDR-plus Beskrivning 3 Inkoppling och konfiguration 3 In-/utgångar

Läs mer

Installationsmanual Multiläsare 2000 användare 12V DC Revidering 1.00

Installationsmanual Multiläsare 2000 användare 12V DC Revidering 1.00 ML 1540 Installationsmanual Multiläsare 2000 användare 12V DC Revidering 00 Innehåll Översikt... 3 Produktbeskrivning... 3 Utmärkande egenskaper... 3 Användning... 3 Larmfunktion... 4 Återställning larm...

Läs mer

Skyline Duox Audio. Installations och användarmanual. Ref Se hemsida / support för senaste manualerna.

Skyline Duox Audio. Installations och användarmanual. Ref Se hemsida / support för senaste manualerna. Skyline Duox Audio Ref. 7390 Installations och användarmanual Se hemsida / support för senaste manualerna. http://www.axema.se/ Ver. 1.0 Skyline Duox Audio axema Sida 1 Innehåll Montering av moduler 2

Läs mer

UDR-plus Universellt dörrlarm

UDR-plus Universellt dörrlarm Manual Uppdaterad 2019-02-04 UDR-plus Universellt dörrlarm Axema Access Control AB Box 90215 120 23 Stockholm, Sweden 08-722 34 40 info@axema.se www.axema.se UDR-plus Beskrivning 3 Inkoppling och konfiguration

Läs mer

UDR-plus Universellt dörrlarm

UDR-plus Universellt dörrlarm Manual Uppdaterad 2018-10-25 UDR-plus Universellt dörrlarm Axema Access Control AB Box 90215 120 23 Stockholm, Sweden 08-722 34 40 info@axema.se www.axema.se UDR-plus Beskrivning 3 Inkoppling och konfiguration

Läs mer

ALLMÄNT 2. Introduktion 2. Åtgärder vid driftsättning 2. Förklaring av termer och begrepp 3. Kommandosyntax 3 HANDHAVANDE 4. Kommandon 4.

ALLMÄNT 2. Introduktion 2. Åtgärder vid driftsättning 2. Förklaring av termer och begrepp 3. Kommandosyntax 3 HANDHAVANDE 4. Kommandon 4. INNEHÅLL ALLMÄNT 2 Introduktion 2 Åtgärder vid driftsättning 2 Förklaring av termer och begrepp 3 Kommandosyntax 3 HANDHAVANDE 4 Kommandon 4 System 5 Aktiviteter 8 Kommandolista 9 TEKNISKA SPECIFIKATIONER

Läs mer

HCS-DEC/1, 2, 4/F manual

HCS-DEC/1, 2, 4/F manual HCS-DEC/1, 2, 4/F manual Vers. 1.1 120320 Innehållsförteckning Anslutningar och mått 3 Funktion 4 Inkoppling 4 Programmering 5-6 Egna anteckningar 7 Teknisk information, beställningsinformation och tillbehör

Läs mer

Installatörs- och användarhandbok DI-623-11/16

Installatörs- och användarhandbok DI-623-11/16 Installatörs- och användarhandbok UNITEL DI-623-11/16 . Så fungerar porttelefonen. När det kommer en besökare trycker han på direktknappen med ditt namn på. Därefter ringer Din telefon. Under samtalet

Läs mer

DAC500 Door Access Control unit

DAC500 Door Access Control unit DAC500 Door Access Control unit Inledning och adressering av Hi-O 3 Adressering av Hi-O enheter 3 Installation 4 Master reset/initiering 5 Initieringsmatris DAC500 6 Bygelfält 7 Streckscheman 8 Anslutning

Läs mer

LAN 53-2 och LAN 54-2 manual

LAN 53-2 och LAN 54-2 manual LN - och LN - manual LRMPNEL LN s s s NO / NC / NC+ / NC- s SUMMLRM (,,C,Driftindikering) C 0s 0s INSTÄLLNING V LRMPNELEN TEST 0s 0s. Tryck på PROGRMMER. Välj ingång med KVITT. 0s 0s. Välj ingångskaraktär

Läs mer

PROMI500 I N S T A L L A T I O N S A N V I S N I N G KODLÅS I KOMPAKT UTFÖRANDE MED INBYGGD BERÖRINGSFRI LÄSARE. PROMI500 Installationsmanual

PROMI500 I N S T A L L A T I O N S A N V I S N I N G KODLÅS I KOMPAKT UTFÖRANDE MED INBYGGD BERÖRINGSFRI LÄSARE. PROMI500 Installationsmanual I N S T A L L A T I O N S A N V I S N I N G Version 1.b PROMI500 Box 9001 400 91 Göteborg, Sweden Tel: +46 31 760 19 30 Fax: +46 31 748 09 30 Email: info@cdvi.se Web: www.cdvi.se KODLÅS I KOMPAKT UTFÖRANDE

Läs mer

Dieselvakt DVGSM/DVSIR/DVMOT

Dieselvakt DVGSM/DVSIR/DVMOT Dieselvakt Maxade funktioner i minimalt format! DVGSM/DVSIR/DVMOT Installations och användarmanual V3.2 Larmtillverkning sedan 1976 www.hellmertz.se Innehållförteckning: Innehållförteckning:... 2 Introduktion

Läs mer

Skyline VDS Porttelefon VDS huvudmodul eller

Skyline VDS Porttelefon VDS huvudmodul eller Manual Uppdaterad 2019-01-25 Skyline VDS Porttelefon VDS huvudmodul 3-7415 eller 3-7421 Axema Access Control AB Box 90215 120 23 Stockholm, Sweden 08-722 34 40 info@axema.se www.axema.se Skyline VDS Porttelefon

Läs mer

INSTALLATION. OPHERA SVARSAPPARAT MED FÄRGMONITOR (Lämna denna manual vid svarsapparaten)

INSTALLATION. OPHERA SVARSAPPARAT MED FÄRGMONITOR (Lämna denna manual vid svarsapparaten) S INSTALLATION OPHERA SVARSAPPARAT MED FÄRGMONITOR (Lämna denna manual vid svarsapparaten) Varning! Rengör svarsapparaten endast med en torr trasa. Ophera en högtalande svarsapparat med färgskärm En svarsapparat

Läs mer

Safeline 1000-Porttelefon Montering och Programmerings manual Augusti 2002

Safeline 1000-Porttelefon Montering och Programmerings manual Augusti 2002 Safeline 1000-Porttelefon Montering och Programmerings manual Augusti 2002 Safeline 1000-P 1 Hela telefonen monteras i hisskorgen Endast ett hål 70X130mm behöver tas upp. Safeline 1000 Montering: Safeline

Läs mer

LAN 63 Masterpanel. RUTAB Lerbacksgatan 2 571 38 Nässjö Tel: 0380-55 50 50 Fax: 0380-123 03 info@rutab.se www.rutab.se. LAN 63 Larmpanel Master

LAN 63 Masterpanel. RUTAB Lerbacksgatan 2 571 38 Nässjö Tel: 0380-55 50 50 Fax: 0380-123 03 info@rutab.se www.rutab.se. LAN 63 Larmpanel Master LAN 63 Masterpanel LAN 63 Larmpanel Master LAN 63 innehåller som standard möjligheten att programmeras för drift eller larm. Litet format; endast 129 x 70 x 27 mm (inbyggnadsdjup 20 mm). 12 larmingångar.

Läs mer

Beröringsfri EM-läsare VDS

Beröringsfri EM-läsare VDS Beröringsfri EM-läsare 3-7440 VDS Beröringsfri EM-läsare 3-7440 Installations och användarmanual Se hemsida / support för senaste manualerna. http://www.axema.se/ Ver. 1.7 axema Sida 1 Innehåll Introduktion:...

Läs mer

BRUKSANVISNING DAAB RADIO DB403 OCH DBR1-M4. Utgåva 1

BRUKSANVISNING DAAB RADIO DB403 OCH DBR1-M4. Utgåva 1 BRUKSANVISNING DAAB RADIO DB403 OCH DBR1-M4 Re vis ion :3 Utgåva 1 FAAC Nordic AB BOX 125, SE-284 22 PERSTORP SWEDEN TEL. +46 435 77 95 00 FAX +46 435 77 95 29 www.faac.se Beskrivning av mottagarna DB403

Läs mer

Larmförbikopplare LFK-500. Installation Programmering Handhavande

Larmförbikopplare LFK-500. Installation Programmering Handhavande Larmförbikopplare LFK-500 Installation Programmering Handhavande INNEHÅLLSFÖRTECKNING BESKRIVNING LFK-500...3 Indikeringar... 3 Tangentbord... 3 PASSAGEKODER, FUNKTIONSKODER...3 HANDHAVANDE...4 Driftlägen...

Läs mer

Kallelse- och signalsystem

Kallelse- och signalsystem P P P P med signalknapp med dragkontakt Sladdtryckknapp med telepropp E 0 0 E 0 E 0 E 0 0 Anropsapparater: Spänningsmatas från ens systemspänningsutgång. Matningsspänning: Max DC. V AC/DC Optiskindikering:

Läs mer

OBSERVERA ATT BYGLARNA MÅSTE HA SAMMA LÄGE!

OBSERVERA ATT BYGLARNA MÅSTE HA SAMMA LÄGE! REV axema akdörrslarm UDR/UDR Teknisk Information UDR är ett bakdörrslarm med eller utan blixtljus, som kan användas till en utrymningsdörr eller för övervakning av en dörr som man vill ha stängd. Som

Läs mer

CAASE ROBUST KODLÅS FÖR ALLA DÖRRMILJÖER. 4 DIAX screw M5x16. 1 M5 DIAX skiftnyckel. 1 Varistor. Bakstycke: 105x80x45mm. Antal Beskrivning Bild

CAASE ROBUST KODLÅS FÖR ALLA DÖRRMILJÖER. 4 DIAX screw M5x16. 1 M5 DIAX skiftnyckel. 1 Varistor. Bakstycke: 105x80x45mm. Antal Beskrivning Bild I I N N S S T T A A L L L A A T T I O I O N N I S N A S N T V R I U S C N T I N O G N S CAASE Box 9001 400 91 Göteborg, Sweden Tel: +46 31 760 19 30 Fax: +46 31 748 09 30 Email: info@cdvi.se Web: www.cdvi.se

Läs mer

Beröringsfri EM-läsare 3-7440 VDS

Beröringsfri EM-läsare 3-7440 VDS Beröringsfri EM-läsare 3-7440 Installations och användarmanual Se hemsida / support för senaste manualerna. http://www.axema.se/ Ver. 1.5 axema Sida 1 Innehåll - Introduktion 2-3 - Kopplingsscheman 4 -

Läs mer

DAC-430/420 Door Access Control unit

DAC-430/420 Door Access Control unit DAC-430/420 Door Access Control unit Inledning 3 Artikelbenämningar 3 Installation med CE 4 Masterreset 5 Tillägg av inre läsare 5 Bygelfält 6 Streckscheman 7 Kopplingsplintar 11 Kopplingsplint KP1 11

Läs mer

Övervakningssystem EKO-KE2

Övervakningssystem EKO-KE2 Övervakningssystem Beskrivning Styr- och övervakningssystem är avsett att användas för automatisk övervakning och funktionskontroll av upp till två brand-/brandgasspjäll, brandgasspjäll eller tryckavlastningsspjäll

Läs mer

Installationsanvisning av Kodlåsmodul 1105/3

Installationsanvisning av Kodlåsmodul 1105/3 Installationsanvisning av Kodlåsmodul 1105/3 Allmänt Kodlåset är i utförande Sinthesi och upptar en modulplats. Enheten kan kombineras med porttelefon och TV-porttelefonanläggningar. Kodlåset behöver en

Läs mer

INSTRUKTION GSM-ENHET GOLDen EAR 1 och 2, TBLZ-1-41-X

INSTRUKTION GSM-ENHET GOLDen EAR 1 och 2, TBLZ-1-41-X INSTRUKTION GSM-ENHET GOLDen EAR 1 och 2, TBLZ-1-41-X Innehållsförteckning Avsnitt Sid 1. Allmänt 2 2. Säkerhetsinstruktioner 2 3. Installation 3 4. Felsökning 5 5. Tekniska data 5 Reservation för ändringar.

Läs mer

DC800. Installations- & Användarhandbok

DC800. Installations- & Användarhandbok DC800 Installations- & Användarhandbok SV Copyright 2006 Bewator AB, Solna. Kopiering ur denna handbok får ske endast efter skriftlig överenskommelse med Bewator. Bewator förbehåller sig rätten att ändra

Läs mer

Om du gör ett misstag när du trycker in din användarkod - tryck helt enkelt in den rätta koden.

Om du gör ett misstag när du trycker in din användarkod - tryck helt enkelt in den rätta koden. ANVÄNDARMANUAL Sida Premier 4/86 Användarmanual. Larmsystemets handhavande Introduktion Innan du försöker att hantera larmsystemet skall du försäkra dig om att du kan koppla till och från systemet på alla

Läs mer

DCU605. Tekniska Data. Datablad SDA00178SE Version 1.1 2015/02/18 Passersystem. Dörrcentral med direkt IP-anslutning till ESMIKKO-server

DCU605. Tekniska Data. Datablad SDA00178SE Version 1.1 2015/02/18 Passersystem. Dörrcentral med direkt IP-anslutning till ESMIKKO-server DCU605 Dörrcentral med direkt IP-anslutning till ESMIKKO-server DCU605 är en dörrcentral med en inbyggd IP-modul som kan anslutas direkt till en ESMIKKO-server via företags-lan. Det finns två produktmodeller.

Läs mer

LAN 63 Masterpanel. LAN 63 Larmpanel Master. Tekniska data Insignal

LAN 63 Masterpanel. LAN 63 Larmpanel Master. Tekniska data Insignal LAN 63 Masterpanel LAN 63 Larmpanel Master LAN 63 innehåller som standard möjligheten att programmeras för drift eller larm. Litet format; endast 129 x 70 x 27 mm (inbyggnadsdjup 20 mm). 12 larmingångar.

Läs mer

Net2 Plus Dörrcentral

Net2 Plus Dörrcentral INS-30172 Dörrcentral Svenska Rev. 2012.01 SE Inledning Dörrcentralen kan anslutas till dator via TCP/IP eller RS485. (Direktanslutning av RS485 till PC endast med tillbehöret Net2USB/RS485 Interface).

Läs mer

MINICODE CL-153 2. INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING

MINICODE CL-153 2. INLÄGGNING AV PROGRAMMERINGSKOD OCH INITIERING Installatörs- och användarhandbok MINICODE CL-153 1. INTRODUKTION MINICODE CL-153 CL-153 CL-153 är bestyckat med ett relä som har en fri växelkontakt. På den jackbara plinten finns ingång för öppningsknapp,

Läs mer

ESIM364. Inkopplingsanvisning

ESIM364. Inkopplingsanvisning Uppstart Innan du spänningsätter enheten måste du montera in ett, se också till att PIN-koden är avstängd. ESIM364 kommunicerar via och behöver därför placeras där du har bästa möjliga -täckning. Enheten

Läs mer

CENTRALAPPARAT MAX-5 INSTALLATIONSANVISNING Best.nr: 12255.

CENTRALAPPARAT MAX-5 INSTALLATIONSANVISNING Best.nr: 12255. CENTRALAPPARAT MAX-5 INSTALLATIONSANVISNING Best.nr: 12255. BESKRIVNING. MAX-5 är en mångkunnig och prisvärd central som med hjälp av en DIP-omkopplare enkelt programeras för olika funktioner. MAX-5 har

Läs mer

Operatörsmanual JPC Kombipanel

Operatörsmanual JPC Kombipanel Operatörsmanual JPC Kombipanel 2008 JEFF Electronics AB Sida 1(13) Innehåll Produktserie Kombi- och Driftspanel... 3 Datainsamling-/Displayenhet... 3 JPC Kombipanel... 4 JPDM Datainsamlingsenhet, master...

Läs mer

MONTERINGSANVISNING & BRUKSANVISNING för CARGARD Portstyrning RDC 30 / RDC 120

MONTERINGSANVISNING & BRUKSANVISNING för CARGARD Portstyrning RDC 30 / RDC 120 MONTERINGSANVISNING & BRUKSANVISNING för CARGARD Portstyrning RDC 30 / RDC 120 CSD AB 2000-05-02 FUNKTIONSBESKRIVNING: GarGard's Portstyrning är avsedd för öppning och stängning av elektriska garageportar,

Läs mer

Handhavarinstruktion. För larmanläggning levererad från Star Alarm AB

Handhavarinstruktion. För larmanläggning levererad från Star Alarm AB Handhavarinstruktion För larmanläggning levererad från Star Alarm AB Viktigt! Tänk på att systemet är programmerat med en såkallad skärmsläckare som med automatik släcker ned displayen efter ca 20 sek.

Läs mer

BAS STRÖMFÖRSÖRJNING Slingövervakningsmodul-EXT/Kretskort

BAS STRÖMFÖRSÖRJNING Slingövervakningsmodul-EXT/Kretskort BAS STRÖMFÖRSÖRJNING Slingövervakningsmodul-EXT/Kretskort FUNKTION / PRESTANDA Monteringsalternativ: Slingövervakningsmodulen kan anslutas till alla 24Vdc strömförsörjningsenheter. I vissa modeller av

Läs mer

PK-01. Kodlås med inbyggd beröringsfri läsare för en dörr. manual och handhavandebeskrivning

PK-01. Kodlås med inbyggd beröringsfri läsare för en dörr. manual och handhavandebeskrivning PK-01 Kodlås med inbyggd beröringsfri läsare för en dörr manual och handhavandebeskrivning 1 PK-01 SATEL OBS! Läs den här manualen noga innan du installerar produkten. Ändringar, modifieringar och reparationer

Läs mer

Handhavarmanual, anläggningsbeskrivning och skötselanvisningar. CAP 400/600

Handhavarmanual, anläggningsbeskrivning och skötselanvisningar. CAP 400/600 Manual LH Electronic Alarm AB Handhavarmanual, anläggningsbeskrivning och skötselanvisningar. CAP 400/600 version II för larmanläggning (Förvaras vid centralapparat/manöverpanel) Innehållsförteckning Områdesbeskrivning

Läs mer

LAN BES 1A/K-R LARMSÄNDARE BES-1A/KR. Beskrivning Vers. 1.1

LAN BES 1A/K-R LARMSÄNDARE BES-1A/KR. Beskrivning Vers. 1.1 LAN BES 1A/K-R LARMSÄNDARE BES-1A/KR 1 2 DRIFT LARM 3 4 5 6 7 8 Beskrivning Vers. 1.1 991030 Box 8727, 402 75 Göteborg * Tel. 031-724 24 24 * Fax 031-724 24 31 E-mail: info@bonab.se * WWW: http://www.bonab.se

Läs mer

BRUKSANVISNING R-COD 200

BRUKSANVISNING R-COD 200 BRUKSANVISNING R-COD 200 ... SID ALLMÄNT OM R-COD 200... 2,3 INNEHÅLL SYSTEMDATA SYSTEMKOD... 4 LJUDINDIKERING... 4 INSLAGSBEGRÄNSNING... 4 TOTAL RADERING... 5 Kod för att kunna programmera. Av/på ljudindikering

Läs mer

R-COD 500 & 500 IR Installera, Driftsätta, Använda

R-COD 500 & 500 IR Installera, Driftsätta, Använda R-COD R-COD 500 & 500 IR Installera, Driftsätta, Använda Montering Inkoppling Programmering Dagligt handhavande Også tilgjengelig på norsk (endast R-COD 500) Også tilgængelig på dansk ( ) Also available

Läs mer

BRUKSANVISNING MONTERINGSANVISNING

BRUKSANVISNING MONTERINGSANVISNING BRUKSANVISNING MONTERINGSANVISNING INNEHÅLLSFÖRTECKNING Sida: 1. BESKRIVNING AV CarGard... 1 2. ANVÄNDNING AV CarGard... 2 Aktivering av larmet...2 Avstängning av larmet...2 Vid larm....2 Vid service av

Läs mer

Installationsguide ME 3

Installationsguide ME 3 (5) Installationsguide ME 3 Ansvarig Författare Godkänd Distribution Nicklas Andersson Nicklas Andersson 999-0-2 / NA Inledning Detta dokument beskriver hur man installerar LuLIS mottagarenhet ME 3. ME

Läs mer

HANDBOK FÖR ENDÖRRSYSTEM

HANDBOK FÖR ENDÖRRSYSTEM HANDBOK FÖR ENDÖRRSYSTEM Dokumentinformation Copyright 204 (c) Tidomat AB. Med ensamrätt. Ingen del av detta dokument får återges, lagras i dokumentsökningssystem eller vidaresändas i någon form utan ett

Läs mer

Manual, GSM-relä rev

Manual, GSM-relä rev www.emco.nu Manual, GSM-relä rev 1.0 2017-11-03 Funktioner i korthet 4 optoisolerade larmingångar 3-15V med individuellt programmerbara SMS-texter Programmerbar tidsfördröjning 0-60s på samtliga ingångar

Läs mer

Handbok FJÄRRSTYRT RELÄ Typ: RR120X/240X

Handbok FJÄRRSTYRT RELÄ Typ: RR120X/240X Handbok FJÄRRSTYRT RELÄ Typ: RR120X/240X CSD AB 97-03-01 RR120X/240X är ett fjärrstyrt dubbelrelä för 12- resp. 24 Volt likström elsystem. Reläet styrs av en mikroprocessor vilken kan ställas in att utföra

Läs mer

Övervakningssystem EKO-KE16

Övervakningssystem EKO-KE16 ssystem Beskrivning Styr- och övervakningssystem är avsett att användas för automatisk övervakning och funktionskontroll av upp till 16 (två spjäll/grupp) brand-/ brandgasspjäll, brandgasspjäll eller tryckavlastningsspjäll

Läs mer

BRUKSANVISNING DAAB UTGÅNGSKORT DB410

BRUKSANVISNING DAAB UTGÅNGSKORT DB410 BRUKSANVISNING DAAB UTGÅNGSKORT DB410 För Styrautomatik DAAB EP104 med programversion 4.07 Revision: 8 FAAC Nordic AB BOX 125, SE-284 22 PERSTORP SWEDEN, +46 435 77 95 00, support@faac.se www.faac.se Teknisk

Läs mer

BRUKSANVISNING R-COD132

BRUKSANVISNING R-COD132 BRUKSANVISNING INNEHÅLLSFÖRTECKNING INNEHÅLLSFÖRTECKNING SPECIFIKATION... 3 Central... 3 Kodlås... 3 HANDHAVANDE... 3 Kod på kodlås... 3 PROGRAMMERING... 4 Koder... 5 Tidszoner... 6 Behörighetszoner...

Läs mer

C17 Relämodul. Manual. Kräver VAKA version 2 eller senare Se för de senaste manualerna.

C17 Relämodul. Manual. Kräver VAKA version 2 eller senare Se   för de senaste manualerna. C17 Relämodul Manual Kräver VAKA version 2 eller senare 20010-07 Se www.axema.se för de senaste manualerna. Innehåll C17 Relämodul... 3 Montage av C17... 4 Installation av modul... 5 Konfigurera C17...

Läs mer

Övervakningssystem EKO-KE16

Övervakningssystem EKO-KE16 Övervakningssystem Beskrivning Styr- och övervakningssystem är avsett att användas för automatisk övervakning och funktionskontroll av upp till 16 (två spjäll/grupp) brand-/ brandgasspjäll, brandgasspjäll

Läs mer

DAC-500 Door Access Control unit

DAC-500 Door Access Control unit DAC-500 Door Access Control unit Inledning 2 Adressering av Hi-O enheter 3 Artikelbenämningar 3 Installation 4 Master reset/initiering 5 Bygelfält 6 Streckscheman 7 Kopplingsplintar 11 Kopplingsplint KP1

Läs mer

INSTALATION GSM-A4. A4 Ins 3 jan -01

INSTALATION GSM-A4. A4 Ins 3 jan -01 GSM-A4 1 2 3 4 U1 U2 E + - INSTALATION Hellmertz Elektronik AB Sjötorpsvägen 8 Box 5 S-230 42 Tygelsjö E-Post Info@Hellmertz.se Tel: 040-466355 Fax: 040-466353 Preliminär! Version: 3.00 Datum: 4 okt 2000

Läs mer

DC800. Konfigureringshandbok

DC800. Konfigureringshandbok DC800 Konfigureringshandbok Data och konstruktion kan komma att ändras utan föregående meddelande. / Leverans i mån av tillgång. Data and design subject to change without notice. / Supply subject to availability.

Läs mer

ED 100 ED 250. Kopplingsexempel

ED 100 ED 250. Kopplingsexempel ED 100 ED 250 Kopplingsexempel Extern Programväljare DORMA sammankopplad med DORMA extern programväljare. Programväljaren är inkopplad på ingången för extern programväljare. Här monterar man en extern

Läs mer

Installationanvisning, apparatlåda för rökfunktion med spjällmotionering TBLZ-2-48-2 GOLD/COMPACT

Installationanvisning, apparatlåda för rökfunktion med spjällmotionering TBLZ-2-48-2 GOLD/COMPACT Installationanvisning, apparatlåda för rökfunktion med spjällmotionering TBLZ-2-48-2 GOLD/COMPACT 1. Allmänt Apparatlådan för rökfunktion med spjällmotionering består av en kontrollenhet för rök,en logikenhet

Läs mer

ESIM264. Inkopplingsanvisning

ESIM264. Inkopplingsanvisning Uppstart Innan du spänningsätter enheten måste du montera in ett SIM-kort, se också till att PIN-koden är avstängd. ESIM264 kommunicerar via GSM och behöver därför placeras där du har bästa möjliga GSM-täckning.

Läs mer

2009-11-19. Gäller från tillverkningsvecka 2005.48

2009-11-19. Gäller från tillverkningsvecka 2005.48 ABC-KSUB/KSUB-LIGHT STYR OCH ÖVERVAKNINGSENHET. Gäller från tillverkningsvecka 2005.48 beskrivning: KSUB är en styr och övervakningsenhet avsedd för att styra olika typer av brand/ brandgasspjäll och fläktar

Läs mer

Teknisk manual Clipper Depth/Ekolod

Teknisk manual Clipper Depth/Ekolod 1 1 Teknisk manual Clipper Depth/Ekolod 2 2 Innehållsförteckning Sammanfattning... 3 Teknisk data... 3 Installation... 4 Display-enhet... 4 Givare... 5 Normalt handhavande... 6 Spänningspåslag... 6 Ändra

Läs mer

DIGITALT VECKOKOPPLINGSUR + PROGRAMMERINGSKNAPP

DIGITALT VECKOKOPPLINGSUR + PROGRAMMERINGSKNAPP DIGITALT VECKOKOPPLINGSUR + PROGRAMMERINGSKNAPP Tekniska data Produkten levereras med aktuellt datum och klockslag inställt. Automatisk växling vinter-/sommartid. Programmeringsknapp - för förbikoppling

Läs mer

Beskrivning - Installation

Beskrivning - Installation Singelgatan 2 212 28 Malmö tel 040-922050 fax 040-193358 Beskrivning - Installation Olje- bensin- fettvarnare Typ ema signal OSA Nivåövervakare OSA Kapacitiv givare ES4 Termistorgivare R6 Läs anvisningen

Läs mer

Bruksanvisning NX-148 Rev.6.0 NX-148. Bruksanvisning Daglig användare. Utgåva ver.6.00 2004-03-01. Microsec AB förbehåller sig rätten till ändringar

Bruksanvisning NX-148 Rev.6.0 NX-148. Bruksanvisning Daglig användare. Utgåva ver.6.00 2004-03-01. Microsec AB förbehåller sig rätten till ändringar Bruksanvisning NX-148 Rev.6.0 NX-148 Bruksanvisning Daglig användare Utgåva ver.6.00 2004-03-01 Microsec AB förbehåller sig rätten till ändringar 1 2 Bruksanvisning för NX-148 Rev.6.0 Bruksanvisning NX-148

Läs mer

Ver 2.2. ELDES ESIM364 Kom igång

Ver 2.2. ELDES ESIM364 Kom igång Ver 2.2 ELDES ESIM364 Uppstart Innan du spänningsätter enheten måste du montera in ett, se också till att PIN-koden är avstängd. ESIM364 kommunicerar via och behöver därför placeras där du har bästa möjliga

Läs mer

SM40. Strömförsörjning med plats för batteri

SM40. Strömförsörjning med plats för batteri LARMDONSSTYRNING BESKRIVNING donskort för montage i 19 kassett (SM911), i våra likriktare eller i kapsling för väggmontage. 19 kassetten SM911 kan förses med 4st kort. Det ger upp till 20 utgångar i en

Läs mer